首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 173 毫秒
1.
试验采用摇动床缺氧-好氧工艺处理渔业加工废水,研究结果表明,摇动床缺氧-好氧工艺对污染物去除效果良好,在BOD5容积负荷为1.5 kg/(m3·d),HRT=5.9~4.7 h,硝化液回流比为1.0的条件下,系统进水中COD、TN和NH+4-N的平均值分别为543.1、72.1和63.6 mg/L时,去除率分别达到93.6%、72.7%和98.9%,出水平均浓度值分别为34.1、19.5和0.7 mg/L,达到《城镇污水处理厂污染物排放标准》(GB 18918-2002) 一级标准。试验期间MLSS最高可达到17 425 mg/L,同时保持SVI在50~70 mL/g的低范围内,污泥沉降性能良好。通过显微镜观察,反应器中生物种类多样,从而保证了摇动床系统极低的污泥产率(MLSS/CODremoval为0.1891),实现了污泥减量。  相似文献   

2.
在SBR中试系统中,采用较高声能密度较短时间的超声波处理剩余污泥后回流至系统连续运行20 d的方式进行污泥减量,通过分析测定系统MLSS、累计排泥量以及系统出水水质指标,考察了系统污泥减量效果及污泥回流对系统污水处理效果的影响。结果表明,对SBR系统2/3的剩余污泥用声能密度为1 W/mL的超声波预处理6 min后回流至SBR系统。SBR系统最终需处置的污泥量减少了45.64%,获得了理想的污泥减量效果。污泥回流后SBR系统对SS、COD、TN以及NH4+-N的去除效果均无明显变化,仅出水TP含量略高于对照的SBR,出水水质仍能达到《城镇污水处理厂污染物排放标准》(GB18918-2002)一级B标准。  相似文献   

3.
焦化废水中COD、挥发酚和硫氰化物同步高效去除   总被引:1,自引:0,他引:1  
采用两级膨胀颗粒污泥床(EGSB)反应器在微氧条件下处理焦化废水,考察了该工艺对焦化废水中挥发酚、硫氰化物、氰化物和COD的去除效果。研究结果表明,在进水流量为1 L/h,总水力停留时间(HRT)为24 h的条件下,两级EGSB反应器对COD的去除效果较好。稳定运行时,在进水挥发酚为56.8~185.1 mg/L、硫氰化物为287.1~539.9 mg/L、氰化物为0.17~0.72 mg/L的条件下,系统对其平均去除率分别为99.9%、96.8%和82.6%,出水挥发酚和氰化物均能达到《污水综合排放标准(GB8978-1996)》的一级标准。进水COD浓度在1 084~1 880 mg/L之间,平均去除率为76.9%,出水平均浓度为325 mg/L。  相似文献   

4.
在SBR中利用光合细菌球形红细菌污泥颗粒进行模拟氯苯废水处理的初步研究,结果表明,采用球形红细菌污泥颗粒处理模拟氯苯废水的SBR系统是可行的,其降解氯苯过程符合Monod一级反应动力学方程。当进水氯苯浓度在125~187.5 mg/L变化时,处理效率都能稳定在90.5%~95.6%之间;其最佳工艺条件为反应时间6 h、DO 4.75~5.0 mg/L、沉淀时间1.5 h、污泥颗粒浓度4 000~6 000 mg/L。在污泥颗粒浓度4 000 mg/L、DO 5.0 mg/L、反应时间6 h的最佳条件下,当进水COD为748.1 mg/L、氯苯浓度100 mg/L时,COD的去除率达90.9%,处理后出水COD满足国家一级排放标准要求。  相似文献   

5.
在SBR中利用光合细菌球形红细菌污泥颗粒进行模拟氯苯废水处理的初步研究,结果表明,采用球形红细菌污泥颗粒处理模拟氯苯废水的SBR系统是可行的,其降解氯苯过程符合Monod一级反应动力学方程。当进水氯苯浓度在125~187.5 mg/L变化时,处理效率都能稳定在90.5%~95.6%之间;其最佳工艺条件为反应时间6 h、DO 4.75~5.0 mg/L、沉淀时间1.5 h、污泥颗粒浓度4 000~6 000 mg/L。在污泥颗粒浓度4 000 mg/L、DO 5.0 mg/L、反应时间6 h的最佳条件下,当进水COD为748.1 mg/L、氯苯浓度100 mg/L时,COD的去除率达90.9%,处理后出水COD满足国家一级排放标准要求。  相似文献   

6.
研究了剩余污泥热水解后的回流对缺氧/好氧膜生物反应器(AOMBR)同步处理污水及污泥减量的影响。试验通过与常规AOMBR工艺对比,考察了污泥热水解回流量对系统污泥浓度、污泥产率、出水水质的影响。试验结果表明,当热水解污泥回流量分别为剩余污泥量的100%、75%、50%时,热水解会一定程度提高系统的污泥浓度,但污泥总量却分别削减了20.2%、21.2%和13.1%,系统污泥产率分别下降了46%、54%和33%,剩余污泥排放量分别削减了100%、75%、50%。两套工艺的平均出水COD、NH+4-N、TN分别在40、3、5mg/L以下,均能达到《城镇污水处理厂污染物排放标准》(GB 18918—2002)的一级A排放标准。因此,热水解污泥的回流并不会对系统的出水水质产生明显影响,同时能够显著削减污泥总量。  相似文献   

7.
朱毅  李晓霞  王俊  李春 《环境工程学报》2012,6(9):2995-3000
针对大豆深加工高浓度有机废水厌氧出水的特点,采用移动床生物膜反应器-沉淀池-厌氧池(MBBR-SA)工艺进行处理,重点考察了其COD去除、脱氮以及污泥减量化的性能。处理前厌氧出水水质参数为COD 1 350~1 851 mg/L、TN 45~73 mg/L和TP 35~55 mg/L。结果表明,经过70 d的运行,在最佳水力停留时间(HRT)1.68 d与最佳回流比0.75条件下,出水平均COD、TN和NH4+-N浓度分别为91.5、12.4和11.4 mg/L,分别达到了《城镇污水处理厂污染物排放标准》二级标准、二级标准和一级B标准,其平均去除率分别为96.0%、87.4%和88.3%;该工艺未排放剩余污泥,其表观污泥产率为0.13,比MBBR降低了43.5%,具有明显的污泥减量化特性。  相似文献   

8.
倒置AAO工艺处理啤酒废水脱氮除磷的研究   总被引:1,自引:0,他引:1  
以某啤酒厂的生产废水为处理对象,对厌氧反应器的出水经倒置AAO工艺进行高效脱碳、深度脱氮除磷。倒置AAO工艺针对射流曝气池进行改造,在不改变原水力停留时间的情况下,采用缺氧区前置的方式,在厌氧区、缺氧区和好氧区设置悬挂式填料,构建生物膜与悬浮污泥的双泥处理系统。结果表明:在20℃条件下,AAO进水COD为180.1 mg/L~575.8 mg/L,NH 4+-N为20 mg/L~35 mg/L,TN为30 mg/L~45 mg/L,TP为5 mg/L~10 mg/L,其平均去除率分别达到了89.5%、97.4%、72.7%和62.5%。最后通过对啤酒废水深度处理工程的改造,废水排放达到一级A排放标准。  相似文献   

9.
采用A/O-CSTR工艺处理高氨氮污泥脱水液。进水氨氮浓度浓度约为375 mg/L,C/N比小于1.0,反硝化碳源明显不足。A/O反应器完成短程硝化反应,CSTR定期投加初沉污泥作为碳源进行反硝化。两者联合达到总氮去除的目的。实验研究短程硝化反应的启动过程,以及CSTR出水回流对短程硝化和系统脱氮效果的影响。实验结果表明系统具有良好的硝化反硝化效果。A/O反应器亚硝酸盐积累率迅速提高并稳定在90%以上。CSTR有效利用初沉污泥实现了稳定的反硝化。出水回流有利于提高总氮去除率,在回流比为200%时,系统平均总氮去除率达到85%以上。  相似文献   

10.
基于多段进水工艺原理,结合污泥自回流好氧生物脱氮反应器结构特征开发的新型分段进水脱氮反应器无需硝化液和污泥回流系统,大大简化了系统配置和操作难度。通过调整进水C/N和进水投配比初步研究了该反应器的去污性能。结果表明,新型分段进水脱氮反应器启动完成(21d)后,在进水COD质量浓度为155~455mg/L的条件下,平均出水COD为(39.6±7.3)mg/L,低于《城镇污水处理厂污染物排放标准》(GB 18918—2002)的一级A标准,且出水COD的变异系数为0.18,出水水质较为稳定;TN的去除主要受进水C/N的影响,NH+4-N的去除主要与最后一级的进水投配比有关。本实验的5种运行工况是以出水NH+4-N达标的前提下尽量去除TN为原则进行进水投配比设计的,在5种运行工况下,TN和NH+4-N去除性能良好,最高分别可达76%和89%。采用新型分段进水脱氮反应器处理浙江省实际生活污水(碱度与总凯氏氮平均比值为7.70)时基本无需调节碱度。  相似文献   

11.
针对小城镇污泥的处理问题,提出了蚯蚓生物滤池解决方案,为此在实验中设置了无蚯蚓对照组,并对污泥的稳定性、污泥性状、蚯蚓与微生物的协同作用以及污泥含有的各种元素存在状态进行了研究,通过蚯蚓生物滤池处理后污泥有机质含量平均相对减少量为11.1%,溶解性化学需氧量(SCOD)增加,滤液中氨氮(NH3-N)含量由20.6~23.9 mg/L降至1.9~4.6 mg/L、滤液中硝态氮(NO3--N)含量由0.2~9.5 mg/L升高到42.0~50.8 mg/L,因此,实验结果表明,蚯蚓生物滤池能显著提高污泥的稳定性,改善污泥脱水性能,有利于污泥后续处理。  相似文献   

12.
Simultaneous sludge reduction and malodor abatement in humus soil cooperated an anaerobic/anoxic/oxic (A2O) wastewater treatment were investigated in this study. The HSR-A2O was composed of a humus soil reactor (HSR) and a conventional A2O (designated as C-A2O).The results showed that adding HSR did not deteriorate the chemical oxygen demand (COD) removal, while total phosphorus (TP) removal efficiency in HSR-A2O was improved by 18 % in comparison with that in the C-A2O. Both processes had good performance on total nitrogen (TN) removal, and there was no significant difference between them (76.8 and 77.1 %, respectively). However, NH4 +–N and NO3 ?–N were reduced to 0.3 and 6.7 mg/L in HSR-A2O compared to 1.5 and 4.5 mg/L. Moreover, adding HSR induced the sludge reduction, and the sludge production rate was lower than that in the C-A2O. The observed sludge yield was estimated to be 0.32 kg MLSS/day in HSR-A2O, which represent a 33.5 % reduction compared to a C-A2O process. Activated sludge underwent humification and produced more humic acid in HSR-A2O, which is beneficial to sludge reduction. Odor abatement was achieved in HSR-A2O, ammonium (NH3), and sulfuretted hydrogen (H2S) emission decreased from 1.34 and 1.33 to 0.06 mg/m3, 0.025 mg/m3 in anaerobic area, with the corresponding reduction efficiency of 95.5 and 98.1 %. Microbial community analysis revealed that the relevant microorganism enrichment explained the reduction effect of humus soil on NH3 and H2S emission. The whole study demonstrated that humus soil enhanced odor abatement and sludge reduction in situ.  相似文献   

13.
采用嗜酸性硫杆菌生物淋滤联合Fenton氧化法对印染污泥脱水性能进行了研究。结果表明,生物淋滤过程中pH下降速率随着硫粉添加量增加而变快,经生物淋滤处理后污泥的脱水性能在一定程度上得到了改善。对生物淋滤后的污泥进行了Fenton氧化处理,获得的最佳反应条件为反应时间2 h,H2O2和Fe2+添加量分别为6 g/L和0.5 g/L。在该条件下,污泥上清液中总有机碳(TOC)由20.8 mg/L增加到356.6 mg/L;污泥比阻(SRF)和滤饼含水率分别由5.98×1011s2/g和88.75%减少至1.26×1011s2/g和82.85%。生物淋滤-Fenton氧化法在污泥破解程度和脱水性能改善方面均优于单独Fenton氧化法。  相似文献   

14.
邹高龙 《环境工程学报》2014,8(6):2467-2472
针对城市生活污水,研究了两点进水倒置A2/O-MBR(平板膜)系统(以下简称系统)对COD、NH+4-N、TN、TP、出水SS影响。结果表明,该系统对COD、NH+4-N具有较高的去除率,出水符合GB18918-2002中一级A标准;当混合液回流比为200%时,系统出水TN浓度小于15 mg/L;正常排泥后,系统对TP的去除率达83%左右;平板膜破损会导致出水SS、COD会受到影响。膜对COD、TP、SS有直接截留作用,由于系统出水几乎没有固体损失,可以精确控制污泥龄,有利于世代周期较长的硝化菌和反硝化菌生长;系统中的污泥浓度可以提高至15 000 mg/L,此时,即使进水量提高0.5倍,出水水质仍保持良好。  相似文献   

15.
This study examines the effects of erythromycin on activated sludge from two French urban wastewater treatment plants (WWTPs). Wastewater spiked with 10 mg/L erythromycin inhibited the specific evolution rate of chemical oxygen demand (COD) by 79% (standard deviation 34%) and the specific N-NH4+ evolution rate by 41% (standard deviation 25%). A temporary increase in COD and tryptophan-like fluorescence, as well as a decrease in suspended solids, were observed in reactors with wastewater containing erythromycin. The destruction of activated sludge flocs was monitored by automated image analysis. The effect of erythromycin on nitrification was variable depending on the sludge origin. Erythromycin inhibited the specific nitrification rate in sludge from one WWTP, but increased the nitrification rate at the other facility.  相似文献   

16.
利用富集培养的硝化污泥研究了苯酚及其衍生物2,4-二氯苯酚、对氨基酚、邻甲基酚和对硝基酚对氨氮生物硝化过程的抑制特性。结果表明,上述5种酚类化合物对硝化细菌的抑制类型均为非竞争性抑制,抑制常数KI和EC50值相等,分别为2.61、1.92、8.50、1.18和6.65 mg/L。上述5种酚类化合物对硝化细菌的抑制程度由大到小的顺序为:邻甲基酚>2,4-二氯苯酚>苯酚>对硝基酚>对氨基酚。酚类化合物对硝化细菌的抑制是可逆的,通过简单的抑制剂稀释或洗涤可以使硝化细菌恢复活性。在保证出水水质的前提下,抑制剂存在时硝化工艺的泥龄被迫延长,且抑制程度越大,泥龄延长的程度越大。当系统受到有毒物质冲击时,和调控泥龄相比,调节工艺的进水流量或改变容积负荷是缓冲冲击的更简捷、快速和有效的途径。  相似文献   

17.
正交实验优化超声波预处理污泥的工况研究   总被引:3,自引:1,他引:2  
在污泥浓度为9 915 mg/L时,选取超声频率、超声声强和超声时间3个因素设计正交实验,以污泥破解度(DDSCOD)、污泥好氧率(SOUR)和脱氢酶(DHA)活性作为指标,对超声波预处理的工况进行了优化。研究结果表明,最佳的超声预处理参数组合为:超声频率28 kHz,声能密度0.15 W/mL,超声时间10 min。此外,研究还发现不同浓度的污泥,对应的最佳超声组合参数也不同。  相似文献   

18.
庄雯  罗建中 《环境工程学报》2013,7(5):1797-1802
为减轻和消除含高浓度KMnO4的牛仔服加工废水对生物处理系统的毒害作用,采用模拟序批式活性污泥法,研究KMnO4对活性污泥微生物生长的影响及COD和NH4+-N的降解规律。结果表明,当处理进水COD浓度500 mg/L,NH4+-N浓度23.5 mg/L,污泥浓度为2 000 mg/L时,曝气时间为4 h,KMnO4质量浓度增加对COD和NH4+-N的降解影响很大;同样条件下曝气时间改为8 h,对NH4+-N的降解影响显著减小,但对COD的降解影响减少不多;并且,高浓度KMnO4对NH4+-N去除效果的抑制作用比对COD的大。因此,处理含高浓度KMnO4的废水需要延长一倍曝气时间,可以获得良好的COD和NH4+-N的降解效果。同时,KMnO4对活性污泥的抑制影响较好地吻合非竞争性抑制机理修正莫若特方程的规律。  相似文献   

19.
通过间歇曝气形成微氧环境让SRB和CSB实现共生,使含硫酸盐有机废水中硫酸根最终转化成单质硫达到脱硫目的.研究考察了曝气量对SRB还原和CSB氧化的影响,确定了合适的曝气强度和水力停留时间,使得单质硫占系统内总硫比值最大.实验结果显示,在进水COD/SO42-=2000/1500 mg/L、曝气开关时间为2 s/2 min、生化时间为10 h时,单质硫产率最大,为89.53%,SO42-浓度降至最低值72.7 mg/L,还原率达95.1%,此时脱硫效果较好.  相似文献   