首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
Chowdhury N  Nakhla G  Zhu J 《Chemosphere》2008,71(5):807-815
A novel liquid-solid circulating fluidized bed bioreactor (LSCFB) configured with anoxic and aerobic columns and lava rock as the biofilm carrier was used to treat synthetic municipal wastewater. Four different empty bed contact times (EBCTs) of 0.82, 0.65, 0.55, and 0.44 h were examined to optimize nutrient removal capability of the system. The LSCFB demonstrated tertiary effluent quality organic and nitrogen removal efficiencies. Effluent characteristics of the LSCFB were soluble biological oxygen demand (SBOD)10 mg l(-1) and total nitrogen (TN)<10 mg l(-1) at organic loading rate (OLR) of 5.3 kg m(-3)d(-1) and nitrogen loading rate of 0.54 kg Nm(-3)d(-1). Remarkably low yields of 0.14, 0.17, 0.19, and 0.21 g VSS g(-1)COD were observed at OLR of 2.6, 3.2, 4.1 and 5.3 kg COD m(-3)d(-1), where increment of biomass growth and detachment rate were also experienced with increasing OLR. However the system demonstrated only 30% phosphorus removal, and mass balances along the anoxic and aerobic columns showed biological phosphorus removal in the system. Organic mass balance showed that approximately 40% of the influent COD was utilized in the anoxic column and the remaining COD was oxidized in the aerobic column. The system is very efficient in nitrification-denitrification, with more than 90% nitrification of ammonium and overall nitrogen removal in the LSCFB was 70+/-11% even at an EBCT of 0.44 h.  相似文献   

2.
In this study, a cascade of anoxic and oxic fluidized bed biofilm reactors system was carried out to treat synthetic municipal wastewater. The parameters of the influent flow rates and C/N ratios were discussed. System performance was acceptable for chemical oxygen demand (COD), ammonia, and total nitrogen removal. A decrease of ammonia and total nitrogen removal efficiencies, however, was observed when the influent flow rates increased to 5.04 and 6.12 1 h(-1). Total nitrogen removal decreased at the influent C/N ratio of 3:1. The measured ratios of COD reduction in the anoxic column to nitrogen removal through nitrification-denitrification were 3.7, 3.5, 3.3, and 3.1 g COD/g(-1) N on average when the influent C/N ratios changed from 6:1 to 3:1. The observed sludge yield (Yobs) was 0.169 g VSS g COD(-1) because of perfect denitrification in the anoxic column and the relatively long solids retention time.  相似文献   

3.
Anaerobic granular sludge, obtained from an upflow anaerobic sludge bed reactor at a brewery waste treatment station, was cultured for 3 months under aeration conditions until the diameter of sludge was in the range 1.8 to 2.6 mm. The aerobic granular sludge gathered acquired the ability of catalyzing simultaneous nitrification and denitrification (SND) and was applied in the study of the process of nitrogen removal in a bioreactor. The ratio between chemical oxygen demand (COD) and ammonium-nitrogen (NH4(+)-N) concentration in the influent was found to be an important factor influencing the process of SND. The final percentage removal of NH4(+)-N reached 100% under the optimal condition of 500 mg/L COD and 0.39 NH4(+)-N/COD. Intermediate products, such as nitrite-nitrogen and nitrate-nitrogen, were also analyzed to clarify the SND process with the aerobic granular sludge.  相似文献   

4.
采用厌氧 缺氧SBR反应器对以硝酸盐作为电子受体的反硝化除磷过程进行了研究。结果表明 ,反硝化聚磷菌完全可以在厌氧 缺氧交替运行条件下得到富集。稳定运行的厌氧 缺氧SBR反应器的反硝化除磷效率 >90 % ,出水磷浓度 <1mg L。进水COD浓度对反硝化除磷的效率影响很大 ,在COD浓度 <180mg L时 ,进水COD浓度越高 ,除磷效率也就越高。较高浓度的进水COD浓度将导致有剩余的COD进入缺氧段 ,对反硝化吸磷构成不利影响。污泥龄为 16d时 ,厌氧 缺氧SBR反应器取得稳定和理想的反硝化除磷效果。污泥龄减少到 8d ,由于反硝化聚磷菌的流失导致反硝化除磷效率的下降。当污泥龄恢复到 16d时 ,经过一段时间的运行 ,反硝化聚磷菌重新得到富集 ,除磷效率恢复到 90 %以上。  相似文献   

5.
为了研究缺氧(75 min)-好氧(294 min)交替运行的SBR系统中除磷的原因,采用静态实验,对比了不同碳源、水质及运行环境下对磷的去除情况。实验结果表明,该SBR脱氮系统中的好氧段磷的减少是生物去除的结果。当供给碳源为丙酸-乙酸混合物(摩尔比为2∶1)、葡萄糖、淀粉或蛋白胨时,污泥都可将磷去除,去除效率依次降低;COD/NO3--N为8.77∶1(400 mg/L∶45.6 mg/L)时除磷效果明显好于5.41∶1(400 mg/L∶73.9 mg/L)和3.57∶1(400 mg/L∶112 mg/L);进水磷浓度为8 mg/L时,COD由50 mg/L增加到400 mg/L,污泥对磷的去除效果基本一样;完全的缺氧或完全的好氧环境下,污泥对磷的去除能力逐渐丧失。  相似文献   

6.
Microbial kinetic analysis of three different types of EBNR process   总被引:3,自引:0,他引:3  
Pai TY  Tsai YP  Chou YJ  Chang HY  Leu HG  Ouyang CF 《Chemosphere》2004,55(1):109-118
The disadvantages of developed biological nutrient removal (BNR) processes (additional energy for liquid circulation and addition of external carbon substrate for denitrification in anoxic zones) were improved by reconfiguring the process into (1) an anaerobic zone followed by multiple stages of aerobic-anoxic zones (TNCU3 process) or (2) anaerobic, oxic, anoxic, oxic zones in sequence (TNCU2 process). These two pilot plants were operated at a recycling sludge ratio of 0.5 without internal recycle of nitrified supernatant. The sludge retention time was maintained at 10 d. The main objective of this study is to analyze the kinetics of different microorganisms in these two processes and A2O process by using the Activated Sludge Model No. 2d. The effective removal efficiency of carbon, total phosphorus and total nitrogen at 87-98%, 92-100% and 63-80%, respectively, were achieved in the testing runs. According to model simulations, the microbial kinetics in the TNCU3 and TNCU2 processes would be affected by different operations. When the step feeding strategy was adopted, the HRT was longer due to the less influent flowrate in the front stages and the microbes would grow in quantities by about 6% in the aerobic reactors. In the followed anoxic reactors, the microbes would decrease in quantities by about 12% due to the dilution effect. The dilution effects in TNCU3 and TNCU2 processes did not take place in A2O process because the recycling mixed liquid from the aerobic reactor to the anoxic reactor still contained particulate components. The XH, XPAO, and XAUT concentrations in the effluent of the last tank were lower when the step-feeding mode was adopted. The TNCU3 and TNCU2 processes could be operated efficiently without nitrified liquid circulation and addition of external carbon substrate for denitrification.  相似文献   

7.
A pilot submerged membrane bioreactor coupled with biological nutrient removal was used to treat the primary effluent at a municipal wastewater treatment plant. Long-term experiments were conducted by varying hydraulic retention time from 6 to 8 hours and solids retention time from 20 to 50 days, respectively. The performance was assessed by monitoring key wastewater parameters, including chemical oxygen demand (COD), nitrogen, and phosphorus concentration in individual anoxic, anaerobic, aerobic, and membrane separation zones. Results showed that the tested system can consistently achieve COD, nitrogen, and phosphorus removal efficiencies at 80 to 98%, 70 to 93%, and 89 to 98%, respectively. Effluent COD remained low as a result of efficient solid retention, even though there was great variation in influent quality. However, total nitrogen increased proportionally with influent concentration. At a 50-day solids retention time, higher COD and nitrogen oxides specific utilization rates in the anoxic zone resulted in a high production of nitrogen oxides in the subsequent aerobic zone.  相似文献   

8.
COD浓度和进水流量比对一体化工艺脱氮除碳的影响   总被引:1,自引:1,他引:0  
保持进水总流量不变,以一定流量比同时从缺氧区和厌氧区进水,探讨了不同进水流量比(R=Q/Q)和进水COD浓度对中心岛式一体化OCO工艺脱氮除碳的影响。研究结果表明,进水COD浓度和进水流量比Rs对COD的去除效果影响不大,出水COD浓度一直稳定在50 mg/L以下,去除率在92%以上;进水COD浓度和进水流量比Rs共同决定着系统TN的去除效果,进水COD浓度为100 mg/L、200 mg/L时,TN去除率随着进水流量比Rs的减小呈增加的趋势;当进水COD浓度为 300 mg/L时,TN去除率随着进水流量比Rs的减小呈先升高后降低的趋势,在进水流量比Rs为3∶1时TN去除率最高,达到87%。  相似文献   

9.
以人工配水为研究对象,采用厌氧/好氧/缺氧/好氧交替运行的序批式反应器,研究了(AO)2SBR系统同步脱氮除磷的效果,并结合批式实验讨论了同步脱氮除磷的反应机理。研究结果表明,该系统以厌氧1.5 h、好氧1 h、缺氧3h、好氧0.5 h的方式运行,在DO=2.5 mg/L,SRT=15 d的条件下,具有良好的脱氮除磷效果,配水中的总氮、总磷、COD和总有机碳的去除率分别为96.26%、99.87%、90.46%和85.57%。批式实验表明,合成的内碳源越多,氨氮的硝化越充分,反硝化除磷越多。  相似文献   

10.
采用一体化A/O移动床生物膜法工艺,以模拟生活污水研究了该工艺的除碳脱氮效果,并对一体化移动床生物膜反应器的好氧区和缺氧区各纵向断面的COD、DO、NH3-N、TN、NO-3-N和NO-2-N进行了检测,通过对缺氧区各断面的DO和TN浓度分布情况,分析了脱氮的产生过程。试验结果表明: 在水力停留时间HRT=12 h,好氧区DO保持5 mg/L左右,COD进水浓度处于250~400 mg/L时,COD的去除率均在90%以上,且出水COD均在40 mg/L以下;TN进水浓度为20~50 mg/L时,NH3-N去除率高于90%,其出水浓度可达到5 mg/L以下,脱氮效率也较高,TN去除率可达到65%~85%。COD和NH3-N的浓度分布状况表明该一体化A/O移动床生物膜反应器的流态趋于全混式。  相似文献   

11.
在分析传统A2/O工艺缺陷的基础上,提出了一种改进型A2/O工艺。为了防止回流污泥中的硝酸盐进入厌氧区,在传统A2/O工艺的厌氧区后面增加一个体积较小的缺氧选择池,回流污泥进入缺氧选择池,并进行反硝化消耗回流污泥中的硝酸盐;同时,在缺氧区通过反硝化除磷实现"一碳两用"。结果表明,改进型A2/O工艺有较好的脱氮除磷效果,在COD为298mg/L、TN为55mg/L左右、TP为7mg/L左右时,系统对COD、TN、TP的平均去除率分别为88.44%、77%、95%。  相似文献   

12.
颗粒污泥与絮状污泥处理垃圾渗滤液的耐盐性能比较   总被引:1,自引:0,他引:1  
通过批次实验系统研究了好氧颗粒污泥和絮状污泥处理垃圾渗滤液时的耐盐性能。实验结果表明,进水含盐量小于10 000 mg/L时,实验所用好氧颗粒污泥和絮状污泥的有机物去除能力、沉降性能、污泥活性基本上不受进水含盐量变化的影响。当进水含盐量大于10 000 mg/L时,随着进水含盐量的增大,絮状污泥的污泥沉降指数(SVI)快速减小,污泥活性及去除有机物的能力下降;相比而言,好氧颗粒污泥沉降性能更为稳定,SVI基本维持在30 mL/g左右,污泥活性及去除有机物的能力缓慢下降。当进水含盐量重新降低时,好氧颗粒污泥沉降性能变化不大,污泥活性及去除有机物的能力恢复迅速;而絮状污泥沉降性能变差,污泥活性及去除有机物的能力仍受较大抑制。  相似文献   

13.
好氧硝化颗粒污泥膜生物反应器性能和膜污染研究   总被引:4,自引:3,他引:1  
实验研究了好氧硝化颗粒污泥膜生物反应器AGMBR的处理性能,并将其与活性污泥膜生物反应器ASMBR进行对比,考察了颗粒污泥在减缓膜污染中所起的作用.好氧硝化颗粒污泥膜生物反应器AGMBR连续稳定运行102 d,系统具有良好的去除有机物和同时硝化反硝化能力,在进水COD和NH+4-N浓度分别为500和200 mg/L时,COD、NH+4-N和TN的去除率分别稳定在86%、94%和45%以上.颗粒污泥有效减缓了膜污染,延长了膜清洗的周期,AGMBR中的膜污染以膜孔堵塞为主,占总阻力的64.81%;滤饼层的阻力为2.1×1012m-1,远小于ASMBR中的16.07×10"m-1;膜清洗周期是相同条件下ASMBR的2.43倍以上;而且AGMBR内不断有新颗粒生成,维持了AGMBR系统性能和运行的稳定.  相似文献   

14.
The phosphate fertilizer industry produces highly hazardous and acidic wastewaters. This study was undertaken to develop an integrated approach for the treatment of wastewaters from the phosphate industry. Effluent samples were collected from a local phosphate fertilizer producer and were characterized by their high fluoride and phosphate content. First, the samples were pretreated by precipitation of phosphate and fluoride ions using hydrated lime. The resulting low- fluoride and phosphorus effluent was then treated with the enhanced biological phosphorus removal (EBPR) process to monitor the simultaneous removal of carbon, nitrogen, and phosphorus. Phosphorus removal included a two-stage anaerobic/aerobic system operating under continuous flow. Pretreated wastewater was added to the activated sludge and operated for 160 days in the reactor. The operating strategy included increasing the organic loading rate (OLR) from 0.3 to 1.2 g chemical oxygen demand (COD)/L.d. The stable and high removal rates of COD, NH4(+)-N, and PO4(3-)-P were then recorded. The mean concentrations of the influent were approximately 3600 mg COD/L, 60 mg N/L, and 14 mg P/L, which corresponded to removal efficiencies of approximately 98%, 86%, and 92%, respectively.  相似文献   

15.
改进倒置A2/O工艺处理生活污水试验研究   总被引:1,自引:0,他引:1  
王琪  刘年丰  张杰  丁峰 《环境污染与防治》2007,29(5):361-362,381
对倒置A2/O工艺进行了缺氧池生物挂膜实验,结果表明,在化粪池出水COD有一定波动情况下,缺氧池COD去除率不仅较高且较稳定,有利于后续硝化反应的进行,提高系统的脱氮效果.同时研究了C/N在缺氧池中对脱氮效果的影响,C/N(质量比)  相似文献   

16.
A preliminary bench-scale study of parallel University of Cape Town (UCT) biological nutrient removal systems showed improvement in anoxic denitrification rates resulting from prefermentation of a septic (i.e., high volatile fatty acid [VFA] content), phosphorus-limited (i.e., total chemical oxygen demand/total phosphorus [TP] ratio < 40:1) wastewater. Net phosphorus removals due to enhanced biological phosphorus removal (EBPR) were only improved marginally by prefermentation in spite of significant increases in anaerobic phosphorus release, polyhydroxyalkanoate formation, and higher anoxic and aerobic uptakes. This probably was due to the high VFA/TP ratio in the raw influent relative to the VFA requirements for EBPR because enough VFAs were already present for phosphorus removal prior to prefermentation. An additional assessment of prefermentation using parallel UCT systems with step feed of 50% of the influent to the anoxic zone was completed. This second phase quantified the effect of prefermentation in a step-feed scenario, which prioritized prefermentation use to enhance denitrification rather than EBPR. While specific denitrification rates in the anoxic zone were significantly improved by prefermentation, high denitrification in the clarifiers and aerobic zones (simultaneous denitrification) made definitive conclusions concerning the potential improvements in total system nitrogen removal questionable. The prefermented system always showed superior values of the zone settling velocity and sludge volume index and the improvement became increasingly statistically significant when the prefermenter was performing well.  相似文献   

17.
A six-stage membrane bioreactor (MBR) pilot plant was operated to determine and demonstrate the capability of this process to produce a low-nutrient effluent, consistent with the nutrient reduction goals for the Chesapeake Bay. Biological nitrogen removal was accomplished using a multistage configuration with an initial anoxic zone (using the carbon in the influent wastewater), an aerobic zone (where nitrification occurred), a downstream anoxic zone (where methanol was added as a carbon source), and the aerated submerged membrane zone. The capability to reliably reduce effluent total nitrogen to less than 3 mg/L as nitrogen (N) was demonstrated. A combination of biological (using an initial anaerobic zone) and chemical (using alum) phosphorus removal was used to achieve effluent total phosphate concentrations reliably less than 0.1 mg/L as phosphorus (P) and as low as 0.03 mg/L as P. Alum addition also appeared to enhance the filtration characteristics of the MBR sludge and to reduce membrane fouling. Aeration of the submerged membranes results in thickened sludge with a high dissolved oxygen concentration (approaching saturation), which can be recycled to the main aeration zone rather than to an anoxic or anaerobic zone to optimize biological nutrient removal. Biological nutrient removal was characterized using the International Water Association Activated Sludge Model No. 2d. The stoichiometry of chemical phosphorus removal was also consistent with conventional theory and experience. The characteristics of the solids produced in the MBR were compared with those of a parallel full-scale conventional biological nitrogen removal process and were generally found to be similar. These results provide valuable insight to the design and operating characteristics of MBRs intended to produce effluents with very low nutrient concentrations.  相似文献   

18.
炭纤维载体固定床厌氧发酵启动运行效果实验   总被引:5,自引:1,他引:4  
以开发高效率、抗冲击性能强的高浓度有机废水沼气发酵技术为目的,用传统的 UASB反应器作为对照,研究了以炭纤维为生物膜载体的固定床厌氧反应器的启动运行效果。反应器进口废水 COD 为 5 000 mg/L, 水力停留时间 (HRT) 由213 h 逐步缩短为35 h,进水有机容积负荷(OLR)由0.56 kg COD/ (m3·d)提到3.45 kg COD/(m3·d)。结果表明,固定床反应器厌氧发酵的效率比对照高,出水 pH 值也比对照稳定;运行到第 50 d 时,固定床厌氧反应器和对照的 COD去除率分别由第 7 d 的36.56%和33.58%上升到87.9%和62.6%;固定床厌氧反应器的容积比产气率最高为1.16 m3/(m3·d),累计产气量为415.59 L,而对照的容积比产气率最高值仅为0.31 m3 /(m3·d),累计产气量为 71.66 L,前者最高容积比产气率和累计产气量分别是后者的3.74倍和5.78倍。固定床厌氧反应器的启动速度、COD 去除率和产甲烷效率显著地高于对照反应器。  相似文献   

19.
Vaiopoulou E  Aivasidis A 《Chemosphere》2008,72(7):1062-1068
A pilot-scale prototype activated sludge system is presented, which combines both, the idea of University of Cape Town (UCT) concept and the step denitrification cascade for removal of carbon, nitrogen and phosphorus. The experimental set-up consists of an anaerobic selector and stepwise feeding in subsequent three identical pairs of anoxic and oxic tanks. Raw wastewater with influent flow rates ranging between 48 and 168 l d(-1) was fed to the unit at hydraulic residence times (HRTs) of 5-18 h and was distributed at percentages of 60/25/15%, 40/30/30% and 25/40/35% to the anaerobic selector, 2nd and 3rd anoxic tanks, respectively (influent flow distribution before the anaerobic selector). The results for the entire experimental period showed high removal efficiencies of organic matter of 89% as total chemical oxygen demand removal and 95% removal for biochemical oxygen demand, 90% removal of total Kjeldahl nitrogen and total nitrogen removal through denitrification of 73%, mean phosphorus removal of 67%, as well as excellent settleability. The highest removal efficiency and the optimum performance were recorded at an HRT of about 9h and influent flow rate of 96 l d(-1), in which 60% is distributed to the anaerobic selector, 25% to the second anoxic tank and 15% to the last anoxic tank. Consequently, the plant configuration enhanced removal efficiency, optimized performance, saved energy, formed good settling sludge and provided operational assurance.  相似文献   

20.
对螺旋升流式反应器脱氮除磷及去除COD的运行效果进行了研究 ,该系统连续稳定运行 6个月的结果表明 ,能保证出水平均质量浓度TN小于 1 0mg/L ,TP小于 0 5 0mg/L ,COD小于 31mg/L ,对TN、TP和COD的去除率分别达 86 %、96 %和 94 %以上。并且对SUFR系统的污泥性能进行了分析 :(1 )螺旋升流特征使本反应系统中的污泥易于颗粒化 ;(2 )SUFR系统中的微生物种群具有多样性 ;(3)污泥在好氧反应器中表现出了同步硝化反硝化功能 ;(4 )污泥在缺氧反应器表现出了反硝化吸磷现象  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号