首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 593 毫秒
1.
Aerosol physical and chemical properties were measured in a forest site in central Amazonia (Cuieiras reservation, 2.61S; 60.21W) during the dry season of 2004 (Aug–Oct). Aerosol light scattering and absorption, mass concentration, elemental composition and size distributions were measured at three tower levels (Ground: 2 m; Canopy: 28 m, and Top: 40 m). For the first time, simultaneous eddy covariance fluxes of fine mode particles and volatile organic compounds (VOC) were measured above the Amazonian forest canopy. Aerosol fluxes were measured by eddy covariance using a Condensation Particle Counter (CPC) and a sonic anemometer. VOC fluxes were measured by disjunct eddy covariance using a Proton Transfer Reaction Mass Spectrometer (PTR-MS). At nighttime, a strong vertical gradient of phosphorus and potassium in the aerosol coarse mode was observed, with higher concentrations at Ground level. This suggests a source of primary biogenic particles below the canopy. Equivalent black carbon measurements indicate the presence of light-absorbing aerosols from biogenic origin. Aerosol number size distributions typically consisted of superimposed Aitken (76 nm) and accumulation modes (144 nm), without clear events of new particle formation. Isoprene and monoterpene fluxes reached respectively 7.4 and 0.82 mg m?2 s?1 around noon. An average fine particle flux of 0.05 ± 0.10 106 m?2 s?1 was calculated, denoting an equilibrium between emission and deposition fluxes of fine mode particles at daytime. No significant correlations were found between VOC and fine mode aerosol concentrations or fluxes.  相似文献   

2.
We describe an experimental system and techniques for sampling and analyzing biogenic emissions of volatile organic compounds (VOC). The system uses a Teflon chamber to enclose a single branch of a tree. Temperature, photosynthetic active radiation (PAR), relative humidity and carbon dioxide concentration are continuously monitored with a time resolution of five minutes. VOCs are sampled on tubes containing solid adsorbents (Tenax TA and Carbotrap) with a time resolution of 1 h. Composition and concentration of VOC emissions are measured with a gas chromatographic system equipped with a flame ionization detector (FID) for quantitative and a mass spectrometer (MS) for qualitative analysis. To calibrate the system, a diffusion source was built to produce standard mixtures of up to 36 different compounds with mixing ratios at low concentrations and high accuracy. The diffusion rates were monitored over 17 months and showed variations between 0.2 and 7.6% for monoterpenes (expect for α-phellandrene, α-terpinene and γ-terpinene) and between 10.6 and 22.6% for sesquiterpenes. FID response factors calculated from calibration measurements were corrected using correction factors based on the effective carbon number concept. The individual response factors of 23 compounds were combined to a mean response factor (RFm) with a value of 23,100 μV s ng−1 and a standard deviation of 9%. The system described here was used to measure VOC emission rates of Scots pine (Pinus sylvestris) in 1998 and 1999.  相似文献   

3.
Available information on soil volatile organic compound (VOC) exchange, emissions and uptake, is very scarce. We here describe the amounts and seasonality of soil VOC exchange during a year in a natural Mediterranean holm oak forest growing in Southern Catalonia. We investigated changes in soil VOC dynamics in drought conditions by decreasing the soil moisture to 30% of ambient conditions by artificially excluding rainfall and water runoff, and predicted the response of VOC exchange to the drought forecasted in the Mediterranean region for the next decades by GCM and ecophysiological models.The annual average of the total (detected) soil VOC and total monoterpene exchange rates were 3.2±3.2 and −0.4±0.3 μg m−2 h−1, respectively, in control plots. These values represent 0.003% of the total C emitted by soil at the study site as CO2 whereas the annual mean of soil monoterpene exchange represents 0.0004% of total C. Total soil VOC exchange rates in control plots showed seasonal variations following changes in soil moisture and phenology. Maximum values were found in spring (17±8 μg m−2 h−1). Although there was no significant global effect of drought treatment on the total soil VOC exchange rates, annual average of total VOC exchange rates in drought plots resulted in an uptake rate (−0.5±1.8 μg m−2 h−1) instead of positive net emission rates. Larger soil VOC and monoterpene exchanges were measured in drought plots than in control plots in summer, which might be mostly attributable to autotrophic (roots) metabolism.The results show that the diversity and magnitude of monoterpene and VOC soil emissions are low compared with plant emissions, that they are driven by soil moisture, that they represent a very small part of the soil-released carbon and that they may be strongly reduced or even reversed into net uptakes by the predicted decreases of soil water availability in the next decades. In all cases, it seems that VOC fluxes in soil might have greater impact on soil ecology than on atmospheric chemistry.  相似文献   

4.
Silage on dairy farms has been identified as a major source of volatile organic compound (VOC) emissions. However, rates of VOC emission from silage are not accurately known. In this work, we measured ethanol (a dominant silage VOC) emission from loose corn silage and exposed corn silage particles using wind tunnel systems. Flux of ethanol was highest immediately after exposing loose silage samples to moving air (as high as 220 g m?2 h?1) and declined by as much as 76-fold over 12 h as ethanol was depleted from samples. Emission rate and cumulative 12 h emission increased with temperature, silage permeability, exposed surface area, and air velocity over silage samples. These responses suggest that VOC emission from silage on farms is sensitive to climate and management practices. Ethanol emission rates from loose silage were generally higher than previous estimates of total VOC emission rates from silage and mixed feed. For 15 cm deep loose samples, mean cumulative emission was as high as 170 g m?2 (80% of initial ethanol mass) after 12 h of exposure to an air velocity of 5 m s?1. Emission rates measured with an emission isolation flux chamber were lower than rates measured in a wind tunnel and in an open setting. Results show that the US EPA emission isolation flux chamber method is not appropriate for estimating VOC emission rates from silage in the field.  相似文献   

5.
Ozone (O3) fluxes above a temperate mountain grassland were measured by means of the eddy covariance (EC) method using a slow-response O3 analyser. The resultant flux loss was corrected for by a series of transfer functions which model the various sources of high- and, in particular, low-pass filtering. The resulting correction factors varied on average between 1.7 and 3.5 during night and daytime, respectively. A cospectral analysis confirmed the accuracy of this approach. O3 fluxes were characterised by a comparatively large random uncertainty, which during daytime typically amounted to 60%. EC O3 fluxes were compared against O3 flux measurements made concurrently with the flux-gradient (FG) method. The two methods generally agreed well, except for a period between sunrise and early afternoon, when the FG method was suspected of being affected by the presence of photochemical sources/sinks. O3 flux magnitudes and deposition velocities determined with the EC method compared nicely with the available literature from grassland studies. We conclude that our understanding of the causes and consequences of various sources of flux loss (associated with any EC system) has sufficiently matured so that also less-than-ideal instrumentation may be used in EC flux applications, albeit at the cost of relatively large empirical corrections.  相似文献   

6.
Micrometeorological flux-gradient and nocturnal boundary layer methods were combined with Fourier transform infrared (FTIR) spectroscopy for high-precision trace gas analysis to measure fluxes of the trace gases CO2, CH4 and N2O between agricultural fields and the atmosphere. The FTIR measurements were fully automated and routinely obtained a precision of 0.1–0.2% for several weeks during a measurement campaign in October 1995. In flux-gradient measurements, vertical profiles of the trace gases were measured every 30 min from the ground to 22 m. When combined with independent micrometeorological measurements of water vapour fluxes, trace gas fluxes from the underlying surface could be determined. In the nocturnal boundary layer method the rate of change in mass storage in the 0–22 m layer was combined with fluxes measured at 22 m to estimate surface fluxes. Daytime fluxes for CO2 were −0.78±0.40 (1σ) mg CO2 m−2 s−1. Daytime fluxes of N2O and CH4 were very small and difficult to measure reliably using the flux-gradient technique, despite the high precision of the concentration measurements. Mean daytime flux for N2O was 17±48 ng N m−2 s−1, while the corresponding flux for CH4 was 47±410 ng CH4 m−2 s−1. The mean nighttime flux of CO2 estimated using the nocturnal boundary layer method was +0.15±0.05 mg CO2 m−2 s−1, in good agreement with chamber measurements of respiration rates. Nighttime fluxes of CH4 and N2O from the nocturnal boundary layer method were 109±69 ng CH4 m−2 s−1 and 2±3.2 ng N m−2 s−1, respectively, in good agreement with chamber measurements and inventory estimates based on the sheep and cattle stocking rates in the region. The suitability of FTIR-based methods for long term monitoring of spatially and temporally averaged flux measurements is discussed.  相似文献   

7.
To determine if an aquifer contaminated with volatile organic compounds (VOCs) has potential for natural remediation, all natural processes affecting the fate and transport of VOCs in the subsurface must be identified and quantified. This research addresses the quantification of air-phase volatile organic compounds (VOCs) leaving the unsaturated zone soil gas and entering the atmosphere-including the additional flux provided by advective soil-gas movement induced by barometric pumping. A simple and easy-to-use device for measuring VOC flux under natural conditions is presented. The vertical flux chamber (VFC) was designed using numerical simulations and evaluated in the laboratory. Mass-balance numerical simulations based on continuously stirred tank reactor equations (CSTR) provided information on flux measurement performance of several sampling configurations with the final chamber configuration measuring greater than 96% of model-simulated fluxes. A laboratory device was constructed to evaluate the flux chamber under both diffusion-only and advection-plus-diffusion transport conditions. The flux chamber measured an average of 82% of 15 diffusion-only fluxes and an average of 95% of 15 additional advection-plus-diffusion flux experiments. The vertical flux chamber has the capability of providing reliable measurement of VOC flux from the unsaturated zone under both diffusion and advection transport conditions.  相似文献   

8.
ABSTRACT

The overall objective of this research was to develop and test a method of determining emission rates of volatile organic compounds (VOCs) and other gases from soil surfaces. Soil vapor clusters (SVCs) were designed as a low dead volume, robust sampling system to obtain vertically resolved profiles of soil gas contaminant concentrations in the near surface zone. The concentration profiles, when combined with a mathematical model of porous media mass transport, were used to calculate the contaminant flux from the soil surface. Initial experiments were conducted using a mesoscale soil remediation system under a range of experimental conditions. Helium was used as a tracer and trichloroethene was used as a model VOC. Flux estimations using the SVCs were within 25% of independent surface flux estimates and were comparable to measurements made using a surface isolation flux chamber (SIFC). In addition, method detection limits for the SVC were an order of magnitude lower than detection limits with the SIFC. Field trials, conducted with the SVCs at a bioventing site, indicated that the SVC method could be easily used in the field to estimate fugitive VOC emission rates. Major advantages of the SVC method were its low detection limits, lack of required auxiliary equipment, and ability to obtain realtime estimates of fugitive VOC emission rates.  相似文献   

9.
A two-resistance exchange interface model (TREIM) was developed to simulate gaseous mercury (Hg) emissions from soils measured by dynamic flux chamber (DFC) operations. The model is based on mass balance principles and a Hg air/soil exchange theory that considers the influence of flushing flow rate on Hg air/soil exchange. We used this model to examine the effect of the flushing flow rate and understand the optimum conditions for DFC measurements of Hg emission fluxes over soils. Our model simulations indicate that the flushing flow rate is a most critical operation condition. We recommend adoption of high flushing flow rates (e.g., ∼15–40 l min−1 for DFCs of common design) based on our simulation findings that underestimation of actual emission fluxes can occur at low flushing flow rates. The biased low fluxes are caused by suppression of emission potential resulting from internal accumulation of emitted Hg and by higher exchange resistance both at low flushing flow rates. This model provides a useful means for estimating maximum steady-state fluxes and soil air Hg concentrations and for adjustment of the fluxes measured under different operating conditions. The model also finds its value in understanding mechanical processes of Hg emissions from soils.  相似文献   

10.
Wuchuan Hg mine, located in the Circum-Pacific Global Mercuriferous Belt, is one of the important Hg production centers in Guizhou province, China. Soil Hg concentrations in this area are elevated by 2–4 orders of magnitude compared to the national background value in soil which is 0.038 μg g−1. In situ air Hg concentrations and air/soil Hg fluxes were measured at five sampling sites in Wuchuan Hg mining area (WMMA) from 19 to 26 December 2003 and from 18 to 25 December 2004. The results showed that air Hg concentrations were 2–4 orders of magnitude higher than those observed in background areas in Europe and North America due to a large amount of Hg emission from artisanal Hg smelting activities. The average in situ Hg fluxes at site Laohugou, Jiaoyan, Luoxi, Sankeng and Huanglong were −5493, 124, −924, −13 and 140 ng m−2 h−1, respectively. Diurnal pattern of Hg flux was not found and a number of negative Hg fluxes were observed in our sampling campaigns. The correlations between Hg fluxes and meteorological parameters such as solar irradiation, air temperature, soil temperature and relative humidity and air Hg concentrations were investigated. The commonly observed significant correlations between Hg fluxes and meteorological parameters observed in many previous studies were not obtained in WMMA. However, significantly negative correlations between Hg flux and air Hg concentration were observed at all sites. Our study demonstrated that highly elevated air Hg concentrations could suppress Hg emission processes even from Hg-enriched soil. At specific conditions in WMMA, air Hg concentrations play a dominant role in controlling Hg emission from soil.  相似文献   

11.
Frequent smog episodes occur during spring, summer, and autumn in Insubria, Northern Italy. On a test site in this area the atmospheric concentration of the photo-oxidants ozone and peroxyacetyl nitrate has been monitored over a year (2000) together with ozone precursors listed in the European Union Air Quality Directive 2002/3/EC, such as nitrous oxides (NOX) and volatile organic compounds (VOC) including hydrocarbons and carbonyls. The results of this study revealed a strong impact of biogenic isoprene on the air quality.In winter isoprene was detected at the ppt level and correlated with anthropogenic VOC. However, during the growing season isoprene exhibited a distinct diurnal variation with maximum concentrations late in the afternoon reaching up 70 ppbC attributed to strong emissions from the abundant vegetation of broad-leaf deciduous trees in this area. A new HPLC-MS method was developed for the determination of isoprene's primary atmospheric oxidation products methacrolein as its 2,4-dinitrophenylhydrazone and methyl vinyl ketone as an unusual double derivative with 2,4-dinitrophenylhydrazine. Methacrolein and methyl vinyl ketone followed the same diurnal and annual trends as isoprene. The average monthly concentration of isoprene and these products ranged from around 10 ppbC in June, July and September to 20 ppbC in August, which constitutes 15–30% of C3–C9 VOCs. The contribution from isoprene photo-oxidation to the ambient air formaldehyde concentrations was also found to be high during this period ranging from 30% to 60% in May, June, July and August.From the atmospheric VOC and NOX concentrations the local photochemical ozone formation was estimated by the incremental reactivity approach. The calculations showed that in summer isoprene's contribution to the local ozone formation was as high as 50–75%.  相似文献   

12.
This study reports on the occurrence and behaviour of six pesticides and one metabolite in a small stream draining a vineyard catchment. Base flow and flood events were monitored in order to assess the variability of pesticide concentrations according to the season and to evaluate the role of sampling frequency on the evaluation of fluxes estimates. Results showed that dissolved pesticide concentrations displayed a strong temporal and spatial variability. A large mobilisation of pesticides was observed during floods, with total dissolved pesticide fluxes per event ranging from 5.7 × 10−3 g/Ha to 0.34 g/Ha. These results highlight the major role of floods in the transport of pesticides in this small stream which contributed to more than 89% of the total load of diuron during August 2007. The evaluation of pesticide loads using different sampling strategies and method calculation, showed that grab sampling largely underestimated pesticide concentrations and fluxes transiting through the stream.  相似文献   

13.
Current regulatory environmental exposure assessments for decamethylcyclopentasiloxane (D5), used in a range of personal care products, are based on a number of erroneous assumptions. Using an estimated D5 flux to waste water of 11.6 mg cap−1 d−1, a 95.2% removal rate in Sewage Treatment Plants (STP) and a dilution factor of 10 results in modelled surface water concentrations that are up to an order of magnitude higher than concentrations observed downstream of STPs in two UK rivers. A GIS-based water quality model (LF2000-WQX) was used to predict concentrations of D5 in two UK rivers. Assuming the STP removal rate is reasonable, a waste water flux of 2.4 mg cap−1 d−1 is needed in order to obtain a reasonable match between predicted and observed in-river concentrations. This flux is consistent with measured effluent concentrations. The results highlight major uncertainties in estimating chemical emission rates for volatile chemicals used in personal care products and suggest that measured concentrations in waste water are needed to refine exposure assessments.  相似文献   

14.
Gaseous methane (CH4) emissions from a swine waste holding lagoon were determined periodically during the year. Micrometeorological techniques were used in order that emission rates from the lagoon were measured under ambient conditions with little disturbance to the natural environment. During the cold winter measurement period, CH4 fluxes were linearly related to lagoon water temperature below 22°C (r=0.87). During warmer measurement periods, both water and air temperatures and windspeed affected emissions rates. In general, flux rates followed a diurnal pattern with greater fluxes during the day when both temperature and windspeed were greatest. Mathematical models using air and water temperature and windspeed factors could explain 47 to 75% of the variation in fluxes. Daily emission rates ranged from 1 to 500 kg CH4 ha−1 d−1. The average flux for the year was 52.3 kg CH4 ha−1 d−1 which corresponded to about 5.6 kg CH4 animal−1 yr−1 from the primary lagoon.  相似文献   

15.
An improved chemical oxidation pretreatment method has been developed for the determination of elemental carbon (EC) [also known as black carbon (BC) or soot] in lake sediments, using a thermal–optical transmittance (TOT) carbon analyzer. The method employs six steps: (1) removal of carbonates by treatment with HCl; (2) removal of silicates by treatment with HF + HCl; (3) removal of any remaining carbonates by treatment with HCl; (4) removal of humic acids by treatment with NaOH; and (5) oxidation of kerogens by K2Cr2O7 + H2SO4. A critical step of zinc chloride treatment was added; this apparently changes EC's morphology and enhances retention on quartz fiber filter, resulting in several-fold increased chemical yield. EC was determined using the TOT method with modified combustion timings. Carbon black (acetylene) and four NIST standard reference materials (SRMs) were used for quality control, and to assess the precision of the analysis. The EC recoveries from 18 carbon black samples varied from 90 to 111%, with a mean value of 99 ± 6%. The high EC recoveries confirmed the validity of the method. Char reference materials (i.e. chestnut wood and grass char) were used to determine potential contribution to EC in our measurements. The char references containing about 700 mg total organic carbon (OC) contributed ~1.5% EC. The measured EC values from four NIST standards were 17.0 ± 0.6, 24.2 ± 3.2, 5.6, and 1.9 ± 0.1 mg gdw?1 for SRM-1648, SRM-1649a, SRM-1941b and SRM-8704, respectively. These values in SRMs were in agreement (<±4%) with the previously reported values. The method was applied to determine the EC in sediment cores from an urban lake and a remote mountain lake in the Northeastern United States. The EC concentrations in two lakes mimic the model EC emissions from the industrial revolution in United States.  相似文献   

16.
Five weeks of gaseous elemental mercury (GEM), reactive gaseous mercury (RGM) and particle bound mercury (Hgp) concentrations as well as fluxes of GEM were measured at Maryhill, Ontario, Canada above a biosolids amended field. The study occurred during the autumn of 2004 (October–November) to capture the effects of cool weather conditions on the behaviour of mercury in the atmosphere. The initial concentration of total mercury (Hg) in the amended soil was relatively low (0.4 μg g−1±10%).A micrometeorological approach was used to infer the flux of GEM using a continuous two-level sampling system with inlets at 0.40 and 1.25 m above the soil surface to measure the GEM concentration gradient. The required turbulent transfer coefficients were derived from meteorological parameters measured on site. The average GEM flux over the study was 0.1±0.2 ng m−2 h−1(±one standard deviation). The highest averaged hourly GEM fluxes occurred when the averaged net radiation was highest, although the slight diurnal patterns observed were not statistically significant for the complete flux data series. GEM emission fluxes responded to various local events including the passage of a cold front when the flux increased to 2 ng m−2 h−1 and during a biosolids application event at an adjacent field when depositional fluxes peaked at −3 ng m−2 h−1. Three substantial rain events during the study kept the surface soil moisture near field capacity and only slightly increased the GEM flux. Average concentrations of RGM (2.3±3.0 pg m−3), Hgp (3.0±6.2 pg m−3) and GEM (1.8±0.2 ng m−3) remained relatively constant throughout the study except when specific local events resulted in elevated concentrations. The application of biosolids to an adjacent field produced large increases in Hgp (25.8 pg m−3) and RGM (21.7 pg m−3) concentrations only when the wind aligned to impact the experimental equipment. Harvest events (corn) in adjacent fields also corresponded to higher concentrations of GEM and Hgp but with no elevated peaks in RGM concentrations. Diurnal patterns were not statistically significant for RGM and Hgp at Maryhill.  相似文献   

17.
Four seasonal sampling campaigns were carried out in the Florida Everglades to measure elemental Hg vapor (Hg°) fluxes over emergent macrophytes using a modified Bowen ratio gradient approach. The predominant flux of Hg° over both invasive cattail and native sawgrass stands was emission; mean day time fluxes over cattail ranged from ∼20 (winter) to ∼40 (summer) ng m−2 h−1. Sawgrass fluxes were about half those over cattail during comparable periods. Emission from vegetation significantly exceeded evasion of Hg° from the underlying water surface (∼1–2 ng m−2 h−1) measured simultaneously using floating chambers. Among several environmental factors (e.g. CO2 flux, water vapor flux, wind speed, water, air and leaf temperature, and solar radiation), water vapor exhibited the strongest correlation with Hg° flux, and transpiration is suggested as an appropriate term to describe this phenomenon. The lack of significant Hg° emissions from a live, but uprooted (floating) cattail stand suggests that a likely source of the transpired Hg° is the underlying sediments. The pattern of Hg° fluxes typically measured indicated a diel cycle with two peaks, possibly related to different gas exchange dynamics: one in early morning related to lacunal gas release, and a second at midday related to transpiration; nighttime fluxes approached zero.  相似文献   

18.
A tall tower flux measurement setup was established in metropolitan Houston, Texas, to measure trace gas fluxes from emission sources in the urban surface layer. We describe a new relaxed eddy accumulation (REA) system combined with a dual-channel GC-FID used for VOC flux measurements, focusing on benzene, toluene, ethylbenzene and xylenes (BTEX) results. Ambient air sampled from 60 m above the ground next to a sonic anemometer was subsampled by a membrane pump and pushed into an REA valve system with two Teflon bag reservoirs, then transferred to two preconcentration units for thermal desorption. We discuss the performance of our system and the selected BTEX measurement results using approximately 8 weeks of data (May 22–July 22, 2008), presenting diurnal variations of concentrations and fluxes of these traffic tracers. The measured values exhibited diurnal cycles with dominant morning and midday peaks during weekdays related to rush hour traffic and additional weekday daytime toluene and xylenes emissions. Local evaporative emissions, likely from solvent usage, significantly contributed to the measured fluxes. We upscaled measured emissions to the county level using a high resolution land cover data set and compared the results with EPA’s National Emission Inventory (NEI).  相似文献   

19.
A study of the relationship between outside air ventilation rate and concentrations of volatile organic compounds (VOCs) generated indoors was conducted in a call center office building. The building, with two floors and a total floor area of 4600 m2, is located in the San Francisco Bay Area, CA. Ventilation rates were manipulated with the building's four air handling units (AHUs). VOC and CO2 concentrations in the AHU returns were measured on 7 days during a 13-week period. VOC emission factors were determined for individual zones on days when they were operating at near steady-state conditions. The emission factor data were subjected to principal component (PC) analysis to identify groups of co-varying compounds. Potential sources of the PC vectors were ascribed based on information from the literature. The per occupant CO2 generation rates were 0.0068–0.0092 l s−1. The per occupant isoprene generation rates of 0.2–0.3 mg h−1 were consistent with the value predicted by mass balance from breath concentration and exhalation rate. The relationships between indoor minus outdoor VOC concentrations and ventilation rate were qualitatively examined for eight VOCs. Of these, acetaldehyde and hexanal, which likely were associated with material sources, and decamethylcyclopentasiloxane, associated with personal care products, exhibited general trends of higher concentrations at lower ventilation rates. For other compounds, a clear inverse relationship between VOC concentrations and ventilation was not observed. The net concentration of 2,2,4-trimethyl-1,3-pentanediol monoisobutyrate isomers, examples of low-volatility compounds, changed very little with ventilation likely due to sorption and re-emission effects. These results illustrate that the efficacy of ventilation for controlling VOC concentrations can vary considerably depending upon the operation of the building, the pollutant sources and the physical and chemical processes affecting the pollutants. Thus, source control measures, in addition to adequate ventilation, are required to limit concentrations of VOCs in office buildings.  相似文献   

20.
Surface–atmosphere mercury fluxes are difficult to measure accurately. Current techniques include dynamic flux chambers and micrometeorological gradient and aerodynamic approaches, all of which have a number of intrinsic problems associated with them. We have adapted conditional sampling (relaxed eddy accumulation), a micrometeorological technique commonly used to measure other trace gas fluxes, to measure surface–air mercury fluxes. Our initial flux measurement campaign over an agricultural soil consisted of two 1-week measurement periods, and was longer in duration than previously reported mercury flux measurement periods. Fluxes during both measurement periods ranged between 190.5 (evolution) and –91.7 ng m−2 h−1 (deposition) with an average evolution of 9.67 ng m−2 h−1. The data showed significant diurnal trends, weakly correlated with shallow soil temperatures and solar radiation. This initial trial run indicates that conditional sampling has much promise for the accurate quantification of both short and long-term mercury fluxes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号