首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
PCDD and PCDF were measured in air samples collected in Ohio in 1987. No 2,3,7,8-TCDD was detected in any of the samples with a detection limits of less than 240 fg/m3. Using a chemical mass balance model applied to PCDD/PCDF congener group profiles, major potential sources of these compounds to the atmosphere in Ohio were determined to be municipal solid waste combustion, and sewage sludge combustion. Cancer risk calculations for inhalation of PCDD/PCDF in ambient air in Ohio are approximately 10–6. Given the current knowledge of the health effects of exposure to PCDD/PCDF in air, there is no appreciable risk to public health for the levels of these compounds found in ambient air in Ohio.  相似文献   

2.
A flux estimate of PCDDs and PCDFs through a waste water treatment plant has been made on an annual basis. The samples were collected from different steps in the treatment procedure within the plant i.e. inlet and outlet water, different sludge types and air samples. From the surroundings of the plant were collected samples of urban air, storm sewer water (urban runoff), plant discharge water and settling particulates from a sediment trap downstream the plant discharge. Differences in congener profiles were found between the samples taken within the plant compared to those collected outside. The flux of PCDD and PCDF equivalents through the plant was found to be approximately 0.4 – 0.5 g/year and the major part was taken away as digested sludge.  相似文献   

3.
The concentrations, compositional profiles, and possible sources of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/PCDF) in water column and surface sediment samples from the lower reaches of the Yangtze River were investigated, and the potential risks posed by these chemicals were evaluated. Concentrations of the 17 2,3,7,8-substituted PCDD/PCDF in the water and sediment samples ranged from 0.45 to 10.0 pg TEQ/L (mean 2.34 pg TEQ/L) and from 0.31 to 51 pg TEQ/g dw (mean 5.25 pg TEQ/g dw), respectively. Water and sediments from the Nanjing–Nantong sections of the Yangtze River were found to have elevated PCDD/PCDF levels, and the PCDD/PCDF TEQ concentrations in 13 sediment samples exceeded the probable effect levels (PEL), above which adverse biological effects are likely. Multivariate statistical analysis indicated that the principal PCDD/PCDF contamination source for the water and sediment was the production and use of pentachlorophenol (PCP) or sodium pentachlorophenate (PCP-Na). PCDD/PCDF concentrations were stable over time near the Yangtze River Estuary but had increased sharply in recent decades in the Nanjing–Nantong section, which will have been related to the growth in industrial activities and other anthropogenic PCDD/PCDF sources. Total organic carbon (TOC) and PCDD/PCDF concentrations correlated significantly (R?=?0.474, P?<?0.01), suggesting that TOC plays an important role in the transport and re-distribution of PCDD/PCDF in the Yangtze River basin.  相似文献   

4.
Polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were found in annually laminated sediments from Lakes Zurich, Baldegg, and Lugano in Switzerland. Octachlorodibenzo-p-diox in (OCDD) predominated, averaging approximately 1.3 ppb. The congener distribution indicated that combustion was the source of PCDD and PCDF in these sediments. In these dated sediment cores, we found that PCDD and PCDF were absent from the sediments before about 1945, but increased thereafter.  相似文献   

5.
On-line detectable indicator parameters in the flue gas of municipal solid waste incinerators (MSWI) such as chlorinated benzenes (PCBz) are well known surrogate compounds for gas-phase PCDD/PCDF concentration. In the here presented work derivation of indicators is broadened to the detection of fly and boiler ash fractions with increased PCDD/PCDF content. Subsequently these fractions could be subject to further treatment such as recirculation in the combustion chamber to destroy their PCDD/PCDF and other organic pollutants' content. Aim of this work was to detect suitable on-line detectable indicator parameters in the gas phase, which are well correlated to PCDD/PCDF concentration in the solid residues. For this, solid residues and gas-phase samples were taken at three MSWI plants in Bavaria. Analysis of the ash content from different plants yielded a broad variation range of PCDD/PCDF concentrations especially after disturbed combustion conditions. Even during normal operation conditions significantly increased PCDD/PCDF concentrations may occur after unanticipated disturbances. Statistical evaluation of gas phase and ash measurements was carried out by means of principal component analysis, uni- and multivariate correlation analysis. Surprisingly, well known indicators for gas-phase PCDD/PCDF concentration such as polychlorinated benzenes and phenols proved to be insufficiently correlated to PCDD/PCDF content of the solid residues. Moreover, no single parameter alone was found appropriate to describe the PCDD/PCDF content of fly and boiler ashes. On the other hand, multivariate fitting of three or four parameters yielded convenient correlation coefficients of at least r=0.8 for every investigated case. Thereby, comprehension of plant operation parameters such as temperatures and air flow alongside concentrations of inorganic compounds in the gas phase (HCl, CO, SO2, NOx) gave the best results. However, the suitable set of parameters suited best for estimation of PCDD/PCDF concentration in solid residues has to be derived anew for each individual plant and type of ash.  相似文献   

6.
Polychlorinated dibenzo-p-dioxin and dibenzofuran (PCDD/PCDF) were overall measured and compared in ambient air, water, soils, and sediments along the upper reaches of the Haihe River of North China, so as to evaluate their concentrations, profiles, and to understand the processes of gas–particle partitioning and air–water/soil exchange. The following results were obtained: (1) The average concentrations (toxic equivalents, TEQs) of 2,3,7,8-PCDD/PCDF in air, water, sediment, and soil samples were 4,855 fg/m3, 9.5 pg/L, 99.2 pg/g dry weight (dw), and 56.4 pg/g (203 fg TEQ/m3, 0.46 pg TEQ/L, 2.2 pg TEQ/g dw, and 1.3 pg TEQ/g, respectively), respectively. (2) Although OCDF, 1,2,3,4,6,7,8-HpCDF, OCDD, and 1,2,3,4,6,7,8-HpCDD were the dominant congeners among four environmental sinks, obvious discrepancies of these congener and homologue patterns of PCDD/PCDF were observed still. (3) Significant linear correlations for PCDD/PCDF were observed between the gas–particle partition coefficient (K p) and the subcooled liquid vapor pressure (P L 0) and octanol–air partition coefficient (K oa). (4) Fugacity fraction values of air–water exchange indicated that most of PCDD/PCDF homologues were dominated by net volatilization from water into air. The low-chlorinated PCDD/PCDF (tetra- to hexa-) presented a strong net volatilization from the soil into air, while high-chlorinated PCDD/PCDF (hepta- to octa-) were mainly close to equilibrium for air–soil exchange.  相似文献   

7.
Leclerc D  Duo WL  Vessey M 《Chemosphere》2006,63(4):676-689
This paper discusses the effects of combustion conditions on PCDD/PCDF emissions from pulp and paper power boilers burning salt-laden wood waste. We found no correlation between PCDD/PCDF emissions and carbon monoxide emissions. A good correlation was, however, observed between PCDD/PCDF emissions and the concentration of stack polynuclear aromatic hydrocarbons (PAHs) in the absence of TDF addition. Thus, poor combustion conditions responsible for the formation of products of incomplete combustion (PICs), such as PAHs and PCDD/PCDF precursors, increase PCDD/PCDF emissions. PAH concentrations increased with higher boiler load and/or low oxygen concentrations at the boiler exit, probably because of lower available residence times and insufficient excess air. Our findings are consistent with the current understanding that high ash carbon content generally favours heterogeneous reactions leading to either de novo synthesis of PCDD/PCDFs or their direct formation from precursors. We also found that, in grate-fired boilers, a linear increase in the grate/lower furnace temperature produces an exponential decrease in PCDD/PCDF emissions. Although the extent of this effect appears to be mill-specific, particularly at low temperatures, the results indicate that increasing the combustion temperature may decrease PCDD/PCDF emissions. It must be noted, however, that there are other variables, such as elevated ESP and stack temperatures, a high hog salt content, the presence of large amounts of PICs and a high Cl/S ratio, which contribute to higher PCDD/PCDFs emissions. Therefore, higher combustion temperatures, by themselves, will not necessarily result in low PCDD/PCDFs emissions.  相似文献   

8.
PCDD/PCDF,chlorinated pesticides and PAH in Chinese teas   总被引:5,自引:0,他引:5  
Fiedler H  Cheung CK  Wong MH 《Chemosphere》2002,46(9-10):1429-1433
Four samples of Chinese tea (two green teas, and two brick teas) were analyzed for their concentrations of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/PCDF), chlorinated pesticides and PAH. The infusions prepared from these teas were also analyzed for PCDD/PCDF. The levels of DDT and its metabolites in tea leaves were within the safety limit of 0.2 mg/kg. Rather high levels of total PAH were obtained in brick tea (1048–1162 mg/kg), when compared with green tea (497–517 mg/kg). In terms of PCDD/PCDF, the concentrations of green tea and brick tea differed by a factor of 16, while the concentrations of all infusions were within a factor of 2. The dioxin concentrations in green tea leaves can be explained through uptake of atmospheric PCDD/PCDF. The higher concentrations in the brick tea leaves are due the longer exposure time, and to certain extent, the use of old leaves, branches and roots when making the tea, and additional components such as soil particulates through contamination. Certain Chinese populations drinking a large amount of brick tea (>3 l per day) indicated that individuals of these populations consume more tea than Europeans or North Americans result in a comparably higher intake of PCDD/PCDF. Tea consumption can attribute to up to 10% of the TDI recommended by WHO (only PCDD/PCDF considered, no PCB analyzed).  相似文献   

9.
Paddy soils and sediments from the Yoneshirogawa, Omonogawa, and Koyoshigawa River Basins in Akita were analyzed for polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). The levels and compositions in those samples including soils from non-agricultural areas (non-agricultural soils) were investigated using isomer-specific analysis to determine characteristic sources. The PCDD/PCDF compositions in the samples were compared with respect to possible sources. The PCDD/PCDF concentrations in paddy soils were much higher than those in the non-agricultural soils and much higher than those found in other parts of Japan. Although PCDD/PCDFs were ubiquitous in sediments from river sources to mouths of the respective river basins, those concentrations were much lower than those from paddy soils and non-agricultural soils, and from other parts of Japan. Comparison of PCDD/PCDF homologues and isomer compositions for samples indicated that compositions of paddy soils and sediments, except for those from river sources, had similar characteristics to PCDD/PCDFs originating from impurities in herbicides, 2,4,6-trichlorophenyl 4-nitrophenyl ether (CNP) and pentachlorophenol (PCP), and that compositions of river-source sediments and non-agricultural soils resembled those of atmospheric depositions. Results of statistical analyses suggest that PCDD/PCDF contamination of paddy soils and sediments is attributable mainly to three sources: CNP, PCP, and atmospheric deposition. Results of this study also demonstrate that CNP and PCP are not only important contaminants of local areas of Japan, but that they exist throughout Akita, in northern Japan. We therefore conclude that PCDD/PCDF pollution caused by those compounds has a widespread influence on paddy soils and river sediments in Japan.  相似文献   

10.
Polychlorinated dibenzo-p-dioxins (PCDD), dibenzofurans (PCDF) and non-ortho substituted biphenyls (PCB, CB) were determined in 6 polar bear milk samples from Svalbard (Norway). For these compounds, no data for polar bears have been reported before from this region. Most of the PCDD/PCDF congeners were found at detectable levels. Concentrations expressed as 2,3,7,8-TCDD equivalents (Nordic model) were in the order of 1–3 pg/g−1 fat (0.2–1.6 pg ml−1 milk) which is comparable with ringed and harp seal blubber from the same region. On whole milk basis, concentrations were similar to those found in human milk. An estimation of the daily uptake via milk showed that the intake is lower for polar bears compared to humans. As in human milk, relatively high levels of OCDD were found in some polar bear milk samples. The PCDD/PCDF congener pattern in the milk was different to that found in polar bear fat from the Canadian Arctic. Non-ortho substituted PCB levels in polar bear milk were similar to those found in polar bear fat from the Canadian North. However, CB 77 or 169 dominated in the milk while CB 126 was the most abundant congener in fat. PCDD/PCDF levels expressed as 2,3,7,8-TE were highly correlated with the fat content of the milk. No correlation between CB and PCDD/PCDF concentrations was found. Some data indicate that PCDD/PCDF concentrations in polar bear milk decrease with increasing time after delivery.  相似文献   

11.
In 1997, the Polychlorinated dibenzo-para-dioxin (PCDD)/Polychlorinated dibenzofuran (PCDF) concentrations in dairy products in Germany and other European countries increased. The PCDD/PCDF source was contaminated lime used in Brazilian citrus pulp pellets. The contaminated lime was mined from an industrial dump site. However, the detailed origin of the PCDD/PCDFs in the lime was not revealed. This paper investigates the contamination origin and describes the link between lime milk from the dumpsite of a chlorine/organochlorine industry and the contaminated lime. The contaminated lime stem from mining at the corporate landfill of Solvay Indupa in Sao Paulo. The landfill was used for 40 years for deposition of production residues and closed in 1996. The factory operated/operates at least two processes with potentially high PCDD/PCDFs releases namely the oxychlorination process for production of ethylene dichloride (EDC) and the chlor-alkali process. The main landfilled waste was lime milk (1.4 million tons) from the vinyl chloride monomer production (via the acetylene process) along with residues from other processes. The PCDD/PCDF fingerprint revealed that most samples from the chemical landfill showed an EDC PCDD/PCDF pattern with a characteristic octachlorodibenzofuran dominance. The PCDD/PCDF pattern of a Rio Grande sediment samples downstream the facility showed a chlor-alkali pattern with a minor impact of the EDC pattern. The case highlights that PCDD/PCDF- and persistent organic pollutants-contaminated sites need to be identified in a comprehensive manner as required by the Stockholm Convention (article 6) and controlled for their impact on the environment and human health. Landfill mining and reuse of materials from contaminated deposits should be prohibited.  相似文献   

12.
Samples of soil, sediment and pine needles from the Reggio Emilia area were analysed in order to estimate the environmental pollution caused by an MSWI. PCDD/PCDF, PCB, PAH and metals were analysed in the collected samples. The data obtained showed relatively low pollution levels. Indeed, the PCDD/PCDF and PCB data were comparable to the values usually found in the grazing areas of the European Union countries. Metal concentrations in soils and sediments may be related to local geological occurrences and to agricultural activities. PAH values are significantly lower than the limit values set by the Italian law.  相似文献   

13.
This report presents results of emission measurements of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) in the flue gas of seven oil, nine gas, and two wood firing systems under laboratory conditions. The burn rate of the combustion was in the range of the rated useful heat output. Two additional test series varied the amount of combustion air and thus the heat output. The PCDD/PCDF emissions for oil- and gas-fired boilers are in the range of 0.0020-0.0142 ng I-TEQ/m3 (referring to 3% O2 in the dry flue gas). No correlation between the combustion technique and the PCDD/PCDF emissions could be established. In the tests with the wood-fired furnaces PCDD/PCDF concentrations in the flue gas ranging from 0.014 to 0.076 ng I-TEQ/m3 (referring to 13% O2 in the dry flue gas) were found. A significant correlation between the firing rate of the heating insert and the measured PCDD/PCDF concentrations was found. On examination of three typical 2,3,7,8-CDD/CDF congener profiles, a comparable pattern could be observed with natural gas and light fuel oil. The congener distribution for wood combustion is considerably different.  相似文献   

14.
When in the vicinity of a metal reclamation plant in Tyrol, Austria, increased PCDD/PCDF levels were found in soil and spruce needles, the extent of grass contamination as well as the PCDD/PCDF content in milk of cows fed with hay from this area was determined. The milk samples showed a significant increase in PCDD/PCDF levels compared to control samples. In a blood sample of a farmer a significant increase in PCDD/PCDF levels was found. Correlations in PCDD/PCDF levels between soil, spruce needles, grass, cow's milk and human blood will be presented.  相似文献   

15.
Hart JR 《Chemosphere》2008,72(1):75-78
Emissions and inlet concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDF) have been measured from a catalytic oxidizer and a thermal oxidizer. The catalyst inlet temperature was 427 degrees C. The thermal oxidizer operating temperature was 791 degrees C. Data of the toxic dioxin and furan congeners are reported. Important results of this field study are: (1) the catalytic oxidizer in this study produced an increase in PCDD/PCDF congener concentration of almost 10-fold from the inlet to the outlet (stack), thus verifying results of a previous study that evaluated only PCDD/PCDF emissions. All congeners increased from inlet to the stack. (2) The thermal oxidizer had little effect on PCDD/PCDF levels. There was a decrease in four of the congeners and an increase in 13 congeners. (3) Ambient air was the main source of PCDD/PCDFs in the stack emissions of the thermal oxidizer in this study. Laboratory investigations are needed to understand how PCDD/PCDFs are formed (and emitted) under conditions of this study.  相似文献   

16.
The River Po is the main Italian river draining one of the most populated and industrialised regions in Italy. As part of a monitoring project to assess environmental quality in the River Po, we measured the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in bottom sediments collected along the whole course of the river, from the spring to the delta, downstream from the confluence of its main tributaries. The aim was to investigate the level of contamination in the main Italian river and the contribution of contaminant loads from the subbasins. Composite sediment samples were collected in summer and winter surveys in low-flow water conditions and analysed by HRGC-HRMS for PCDD and PCDF homologue groups and for the 2,3,7,8-substituted congeners. The spatial trend observed in the Po River for PCDD and PCDF concentrations varied depending on the load of contaminants received from the tributaries and the processes of sedimentation. The sum of PCDD and PCDF concentrations, and the toxic equivalent content, ranged from 121 to 814 and from 1.3 to 13 ng/kg dry weight sediment, respectively. These levels of contamination seem lower than in the sediments of rivers draining highly industrialised areas. The PCDD and PCDF homologue profiles in all the samples were very similar, suggesting a common source of this contamination in the River Po. Principal component analysis suggested that widespread sources, such as urban runoff and domestic wastewaters, are probably the main cause of these levels of PCDDs and PCDFs.  相似文献   

17.
In laboratory-scale combustion of polyvinylidene chloride (PVDC) with a quartz tubular furnace designed and fabricated to provide the desired combustion temperature and mixing state of combustion gas with air, it was found that at 800 degrees C or higher the level of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans [corrected] (PCDDs/PCDFs) resulting from PVDC combustion was no higher than that from heating air alone, and thus far below the levels which resulted from PVDC combustion at 750 degrees C or lower. The results provide the first laboratory confirmation of the relation between PVDC incineration temperature and PCDD/PCDF formation, and of the primary importance of high temperature, turbulence for mixing between air and combustion gas, and sufficient residence time, as governing factors for the minimization of PCDD/PCDF formation in municipal solid waste incinerators.  相似文献   

18.
Weber R  Sakurai T  Ueno S  Nishino J 《Chemosphere》2002,49(2):127-134
The correlation of PCDD/PCDF levels with the CO emissions in a full-scale municipal waste incinerator was assessed during a four-week measurement effort. PCDD/PCDF concentrations in fly ashes-containing more than 99% of the total PCDD/PCDF burden of the fluidized bed incinerator (FBI)-were measured and compared with the emitted CO concentrations. The CO concentration during the sampling time showed no significant correlation to the PCDD/ PCDF amount in fly ash (R2 = 0.078). However, a comparison of the time integrated CO concentration several hours before sampling lead to a correlation with the PCDD/PCDF burden. Maximum correlation was found for the time integrated CO values of 3 and 4 h before sampling (R2 = 0.467 and R2 = 0.457 respectively). This indicates a memory effect in the high temperature cooling section of several hours. Possible mechanisms leading to the memory effect are discussed. The correlation of PCDD/PCDF with CO concentration demonstrate that the combustion conditions play an important role for PCDD/PCDF formation in FBIs. However the variability in the correlation of CO to PCDD/PCDF levels show that other factors have a significant influence on PCDD/PCDF formation.  相似文献   

19.
At a MSWI (municipal solid waste incinerator) plant PCDD/PCDF samples (gasphase and particulates) were taken simultaneously be a shock-freezing method in the incinerator combustion chamber at approx. 800°C and in four sampling sections in the boiler at about 490°C, 370°C, 330°C and 270°C. In this way PCDD/PCDF-formation in the flow through the boiler was determined. Two data sets were evaluated. A considerable PCDD/PCDF-formation had occurred already at boiler temperatures of about 490°C; the highest concentration, however, was found at the end of the boiler at about 300°C. The accompanying measuring program of plant parameters made the calculation of the PCDD/PCDF mass flows possible, which allowed the inclusion of the PCDD/PCDF-content in the ESP dust in the mass flow calculations.  相似文献   

20.
Dated sediment cores provide an excellent way to investigate the historical input of persistent organic pollutants into the environment and to identify possible sources of pollution. The vertical distribution of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDD/F) and polychlorinated biphenyls (PCB) was investigated in a sediment core from Greifensee to elucidate the historical trends of PCDD/F and PCB inputs between 1848 and 1999. Concentrations of PCB and PCDD/F increased by more than one order of magnitude between 1930 and 1960. PCB and PCDD/F concentrations were 5700 ng/kg dry weight (dw) and 160 ng/kg dw, respectively, in sediments originating from the late 1930s and reached a maximum of 130,000 ng/kg dw and 2400 ng/kg dw, respectively, in the early 1960s. From 1960 on, concentrations decreased to the 1930s level by the mid 1980s. A remarkable shift in the PCDD/F pattern was observed after the early 1940s. Before 1940, the PCDD/F pattern was PCDF dominated (ratio of PCDD to PCDF=0.41+/-0.11), while the PCDD started to be the major species after the early 1940s (ratio of PCDD to PCDF=1.46+/-0.38). The temporal trends of PCB and PCDD/F correlate surprisingly well with each other. This might be due to the coincidence of two factors. The introduction of PCB on the market in the 1930s resulted in emissions due to the widespread use of these industrial chemicals. In the same time period, waste incineration became an increasingly popular way to get rid of garbage, boosting the PCDD/F emissions significantly. The rapid decline of PCDD/F and PCB concentrations in the sediment starting in the early 1960s reflects the result of better emission control techniques in thermal processes and the improvement of waste water treatment in the catchment of Greifensee.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号