首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 593 毫秒
1.
The main objective of this study was to investigate the feasibility of coagulation as a post-treatment method of anaerobically treated primary municipal wastewater. Both mesophilic and ambient (20 degrees C) temperature conditions were investigated in a laboratory-scale upflow anaerobic sludge bed (UASB) reactor. In addition, optimization of the coagulant, both in terms of type and dose, was performed. Finally, phosphorus removal by means of aluminum and iron coagulation and phosphorus and ammonia nitrogen removal by means of struvite precipitation were studied. Anaerobic treatment of primary effluent at low hydraulic retention times (less than 15 hours) resulted in mean chemical oxygen demand (COD) removals ranging from 50 to 70%, while, based on the filtered treated effluent, the mean removals increased to 65 to 80%. Alum coagulation of the UASB effluent gave suspended solids removals ranging from approximately 35 to 65%. Turbidity removal reached up to 80%. Remaining COD values after coagulation and settling were below 100 mg/L, while remaining total organic carbon (TOC) levels were below 50 mg/L. Filterable COD levels were generally below 60 mg/L, while filterable TOC levels were below 40 mg/L. All coagulants tested, including prepolymerized aluminum and iron coagulants, demonstrated similar efficiency compared with alum for the removal of suspended solids, COD, and TOC. Regarding struvite precipitation, optimal conditions for phosphorus and nitrogen removal were pH 10 and molar ratio of magnesium: ammonia-nitrogen: phosphate-phosphorus close to the stoichiometric ratio (1:1:1). During struvite precipitation, removal of suspended solids reached 40%, while turbidity removal reached values up to 80%. The removal of COD was approximately 30 to 35%; yet, when removal of organic matter was based on the treated filterable COD, the removal increased to approximately 65%. In addition, nitrogen was removed by approximately 70%, while phosphorus removal ranged between approximately 30 and 45% on the basis of the initial phosphorus concentration. Finally, size fractionation of the organic matter (COD) showed that the various treatment methods were capable of removing different fractions of the organic matter.  相似文献   

2.
Yan M  Wang D  Shi B  Wang M  Yan Y 《Chemosphere》2007,69(11):1695-1702
Although ozone is widely used as a pre-oxidant before coagulation in water treatment, the effect of pre-ozonation on optimized coagulation for removal of particle and natural organic matter (NOM) is still not fully understood. In this paper, pilot-scale investigation was conducted to examine the impact of pre-ozonation on coagulation for particle and NOM removal. Changes in the particle and NOM distributions were characterized by various methods, including laser light granularity system, particle counter, ultrafiltration, and resin absorbent fractionation. A novel composite flocculant–HPAC was compared with the traditional ferric chloride coagulant in terms of coagulation efficiency under the influence of pre-ozonation. Typical micro-polluted North China surface water was used for pilot coagulation tests. The results show that the effect of pre-ozonation on coagulation is associated with the dosage of ozone, coagulant type, and water contamination characteristics. For FeCl3, pre-ozonation acts as a coagulation aid at low dosage (1.0 mg L−1 O3) for turbidity and UV254 removal; while at higher dosage (2.0 mg L−1 O3), pre-ozonation is detrimental to UV254 removal although it is still beneficial for turbidity removal. In the case of composite flocculant–HPAC, pre-ozonation demonstrates negligible influence on both turbidity and UV254 removal. Ozone can simultaneously aggregate fine particles and break down large ones, making them more mineralized and easier to remove. NOM with intermediate molecular weight and hydrophobic neutral property increases at lower ozone dosage, favoring removal by coagulation. At higher ozone dosages, NOM becomes more hydrophilic and its molecular weight becomes smaller, decreasing NOM removal.  相似文献   

3.
针对北京某水库水在冬季呈现低温低浊特性,以此为原水的某水厂在该期间常会出现出水余铝超标现象的问题,通过烧杯实验研究不同投药量下聚合氯化铝(PAC)以及它与三氯化铁(FeCl3)不同复配比形成混凝剂对冬季北京某水库水的处理效果。结果表明,复配药剂存在最佳的Fe/Al摩尔复配比为1/5,此时余铝、有机物去除效果较其他配比混凝剂高。在此配比下,当PAC投药量为0.03 mmol/L时,水中残余铝量取得最低值0.0063 mg/L。相同投药量复配药剂的浊度去除效果比单独使用PAC的浊度去除效果略弱。当投药量为0.06 mmol/L时,Fe/Al摩尔比为1/5的复配混凝剂,能使浊度降至0.4 NTU左右。此外,复配药剂的投药量小,投药范围更宽,易于实际投药操作;同时复配药剂还适于常温及偏中性水源水的处理。规模为5 m3/h中试实验也证明,采用铁铝复配混凝剂连续运行,可获得良好的浊度、余铝去除效果。  相似文献   

4.
Yan M  Wang D  Yu J  Ni J  Edwards M  Qu J 《Chemosphere》2008,71(9):1665-1673
Enhanced coagulation is considered to be among the best available techniques (BAT) for disinfection by-product (DBP) precursor removal in water treatment. Improving existing understanding requires further consideration of nuances of chemical speciation relative to source water chemistry. In this paper, the effect of alkalinity/pH and speciation on inorganic polymer flocculants, polyaluminum chlorides (PACls) for enhanced particle and natural organic matter (NOM) removal was investigated. Three kinds of well-characterized typical source waters in China with low, moderate, and high alkalinity were selected. Performance of coagulants is controlled not only by preformed species but also by those formed in situ. At neutral and basic pH values, PACls with higher basicity (ratio of OH(-)/Al), which have more stable preformed Alb (the rapid reacted species as in ferron assay), are more efficient for turbidity and NOM removal. At slightly acidic pH, PACls with lower basicity are more efficient since more Alb can be formed in situ. Optimal NOM removal was achieved at pH 5.5-6.5 for all PACls. Basicity, speciation, and dosage of coagulant should be optimized based on raw water alkalinity to enhance the removal efficiency of NOM.  相似文献   

5.
The objectives of this work were the assessment of the effectiveness of coagulation on the reclamation of secondary effluents and the evaluation of the quality of reclaimed waters by the examination of their ecotoxic and mutagenic properties. Aluminum coagulants resulted in higher removal of organic content, than iron coagulant, reaching up to 40%; the removal of heavy metals, such as zinc and copper was enhanced by the addition of a low strength anionic flocculant. The toxicity of pre-concentrated samples to the bacteria Vibrio fischerii was related to the heavy metal content, especially zinc and copper, indicating the significance of the metals bioavailability and their potential interactive effects. The secondary effluents exhibited mutagenic effects on strain TA 98; these effects were increased during coagulation with ferric chloride (both in absence and presence of flocculant). However, the addition of aluminum coagulants resulted in a decrease of mutagenic potential of secondary effluents, due to the extended removal of organic matter.  相似文献   

6.
《Chemosphere》2008,70(11):1695-1702
Although ozone is widely used as a pre-oxidant before coagulation in water treatment, the effect of pre-ozonation on optimized coagulation for removal of particle and natural organic matter (NOM) is still not fully understood. In this paper, pilot-scale investigation was conducted to examine the impact of pre-ozonation on coagulation for particle and NOM removal. Changes in the particle and NOM distributions were characterized by various methods, including laser light granularity system, particle counter, ultrafiltration, and resin absorbent fractionation. A novel composite flocculant–HPAC was compared with the traditional ferric chloride coagulant in terms of coagulation efficiency under the influence of pre-ozonation. Typical micro-polluted North China surface water was used for pilot coagulation tests. The results show that the effect of pre-ozonation on coagulation is associated with the dosage of ozone, coagulant type, and water contamination characteristics. For FeCl3, pre-ozonation acts as a coagulation aid at low dosage (1.0 mg L−1 O3) for turbidity and UV254 removal; while at higher dosage (2.0 mg L−1 O3), pre-ozonation is detrimental to UV254 removal although it is still beneficial for turbidity removal. In the case of composite flocculant–HPAC, pre-ozonation demonstrates negligible influence on both turbidity and UV254 removal. Ozone can simultaneously aggregate fine particles and break down large ones, making them more mineralized and easier to remove. NOM with intermediate molecular weight and hydrophobic neutral property increases at lower ozone dosage, favoring removal by coagulation. At higher ozone dosages, NOM becomes more hydrophilic and its molecular weight becomes smaller, decreasing NOM removal.  相似文献   

7.
A laboratory study demonstrated that ferrate pretreatment significantly enhanced lead and cadmium removal in alum coagulation, under the conditions of natural surface water. The enhancement of lead removal was approximately 21 to 37% by ferrate pretreatment at a dosage of 1 to 5 mg/L. The enhanced removal of cadmium by ferrate pretreatment at a dosage of 1 to 5 mg/L exceeded the removal by alum coagulation alone 2-to 12-fold. Cadmium is much more difficult to remove than lead in alum coagulation. The performance of ferrate in enhancing the removal of lead and cadmium in alum coagulation was better than that of ferric chloride. The removal of lead and cadmium was highly pH-dependent, following the general trend of higher pH being related to higher removal. Satisfactory removal of cadmium could be expected by ferrate pretreatment combined with adjusting the pH of the water.  相似文献   

8.
考察了4种混凝剂,高效聚合氯化铝(HPAC),聚合氯化铝(PACl),硫酸铝(Al2(SO4)3),混合PACl和氯化铁(FeCl3),对低温低浊黄河原水的混凝效果与沉后水残留铝含量的关系。结果表明,当采用Al2(SO4)3或PACl做混凝剂时,在取得较好浊度去除的投药量下,水中余铝浓度会超过国家标准(0.2131g/L)。而采用HPAC或FeCl3和PACl复配药剂,在取得与Al2(SO4)3或PACl类似的浊度去除效果的同时,也能较好地控制水中的余铝含量。当HPAC投加量为21mg/L时,沉后水浊度降至1.3NTU,残留铝含量为0.147mg/L。复配投加PACl 15mg/L和FeCl3 12mg/L后,沉后水浊度为1.18NTU,残留铝含量为0.074mg/L。PACl和氯化铁的复配比例需要精确的调控,否则容易导致出水余铁余铝含量增加。而HPAC投加量小于21mtg/L时出水余铝浓度均低于国家标准。因此,在这4种混凝剂中,就混凝效果及余铝控制而言,HPAC更适合充当低温低浊水源水的混凝处理药剂。  相似文献   

9.
The present work investigates the impacts and mechanisms associated with natural organic matter (NOM) in the Fe0 treatment system of Cu2+ and Zn2+ under roof runoff conditions. The NOM in runoff waters was characterized using XAD-4/8 adsorption resins, copper complexation, acidic capacity and liquid chromatography with online carbon detection. Batch kinetic experiments and flow-through configurations were performed and the results of metal removal were elucidated taking into account the characteristics of NOM. Based on the findings, it is shown that NOM influences the removal of metals through several complex pathways. At an un-favored condition for adsorption of metals, i.e., on iron corrosion products, at pH相似文献   

10.
The goal of this study was to determine the removal efficiencies of chromium, copper, lead, nickel, and zinc from raw wastewater by chemically enhanced primary treatment (CEPT) and to attain a total suspended solids removal goal of 80%. Operating parameters and chemical doses were optimized by bench-scale tests. Locally obtained raw wastewater samples were spiked with heavy metal solutions to obtain representative concentrations of metals in wastewater. Jar tests were conducted to compare the metals removal efficiencies of the chemical treatment options using ferric chloride, alum, and anionic polymer. The results obtained were compared with those from other studies. It was concluded that CEPT using ferric chloride and anionic polymer is more effective than CEPT using alum for metals removal. The CEPT dosing of 40 mg/L ferric chloride and 0.5 mg/L polymer enhanced heavy metals removal efficiencies by over 200% for chromium, copper, zinc, and nickel and 475% for lead, compared with traditional primary treatment. Efficient metals capture during CEPT can result in increased allowable headworks loadings or lower metal levels in the outfall.  相似文献   

11.
In the present study, feasibility of recovering the coagulant from water treatment plant sludge with sulphuric acid and reusing it in post-treatment of upflow anaerobic sludge blanket (UASB) reactor effluent treating municipal wastewater were studied. The optimum conditions for coagulant recovery from water treatment plant sludge were investigated using response surface methodology (RSM). Sludge obtained from plants that use polyaluminium chloride (PACl) and alum coagulant was utilised for the study. Effect of three variables, pH, solid content and mixing time was studied using a Box–Behnken statistical experimental design. RSM model was developed based on the experimental aluminium recovery, and the response plots were developed. Results of the study showed significant effects of all the three variables and their interactions in the recovery process. The optimum aluminium recovery of 73.26 and 62.73 % from PACl sludge and alum sludge, respectively, was obtained at pH of 2.0, solid content of 0.5 % and mixing time of 30 min. The recovered coagulant solution had elevated concentrations of certain metals and chemical oxygen demand (COD) which raised concern about its reuse potential in water treatment. Hence, the coagulant recovered from PACl sludge was reused as coagulant for post-treatment of UASB reactor effluent treating municipal wastewater. The recovered coagulant gave 71 % COD, 80 % turbidity, 89 % phosphate, 77 % suspended solids and 99.5 % total coliform removal at 25 mg Al/L. Fresh PACl also gave similar performance but at higher dose of 40 mg Al/L. The results suggest that coagulant can be recovered from water treatment plant sludge and can be used to treat UASB reactor effluent treating municipal wastewater which can reduce the consumption of fresh coagulant in wastewater treatment.  相似文献   

12.
Kristiana I  Joll C  Heitz A 《Chemosphere》2011,83(5):661-667
The removal of organic precursors of disinfection by-products (DBPs), i.e. natural organic matter (NOM), prior to disinfection and distribution is considered as the most effective approach to minimise the formation of DBPs. This study investigated the impact of the addition of powdered activated carbon (PAC) to an enhanced coagulation treatment process at an existing water treatment plant on the efficiency of NOM removal, the disinfection behaviour of the treated water, and the water quality in the distribution system. This is the first comprehensive assessment of the efficacy of plant-scale application of PAC combined with enhanced coagulation on an Australian source water. As a result of the PAC addition, the removal of NOM improved by 70%, which led to a significant reduction (80-95%) in the formation of DBPs. The water quality in the distribution system also improved, indicated by lower concentrations of DBPs in the distribution system and better maintenance of disinfectant residual at the extremities of the distribution system. The efficacy of the PAC treatment for NOM removal was shown to be a function of the characteristics of the NOM and the quality of the source water, as well as the PAC dose. PAC treatment did not have the capacity to remove bromide ion, resulting in the formation of more brominated DBPs. Since brominated DBPs have been found to be more toxic than their chlorinated analogues, their preferential formation upon PAC addition must be considered, especially in source waters containing high concentrations of bromide.  相似文献   

13.
高锰酸盐复合药剂强化混凝改善再生水景观湖水质研究   总被引:1,自引:0,他引:1  
实验通过投加助凝剂以强化混凝沉淀过程,从而达到去除再生水景观水中的藻类。以PAC为混凝剂,高锰酸盐复合药剂(PPC)为预氧化助凝剂,通过烧杯实验确定PPC、PAC同时投加,最佳投量分别为1 mg/L、60 mg/L。生产性实验中,机械加速澄清池强化混凝对TP、叶绿素、藻密度的去除率分别为54%、32.3%和35.4%,湖水中TP、TN逐渐降低分别由4.9 mg/L、23 mg/L降至0.72 mg/L、10.3 mg/L。PPC提高了混凝沉淀对藻类的去除效果,改善了再生水景观湖水质,降低水中氮磷营养盐的含量。  相似文献   

14.
以向地表水中投加的隐孢子虫微球和贾第鞭毛虫微球为对象,研究通过对给水混凝工艺对其的去除效果进行比较,着重考察了不同混凝剂种类、投加量及水样pH值对去除效果的影响.结果表明,混凝工艺可较为有效地去除地表水中的两虫微球,去除率最高可达4 lg.相比常规的金属盐类混凝剂,高分子的PAC、PAFC混凝剂对两虫微球的混凝去除率更...  相似文献   

15.
本实验以工业化学合成聚合硫酸铁混凝剂和自制生物聚合硫酸铁为例,考察了铁系混凝剂品种对地表水浊度、TOC和UV254的去除效果,混凝剂品种对混凝-超滤联合工艺处理地表水过程中超滤膜污染的影响。混凝实验结果表明,在10 mg/L(以Fe3+计)最佳投加量下,两类混凝剂对浊度、TOC和UV254的去除率基本相同。超滤膜污染实验结果表明,生物聚合铁预处理水样通量衰减速度略大于化学聚合铁预处理水样;膜污染阻力分析结果显示,随着循环次数的增加,工业化学合成聚合铁预处理水样造成的不可逆污染阻力逐渐增加,而生物聚合铁预处理水样造成的不可逆污染阻力却略有下降;膜污染机理分析表明,2组过滤过程的膜污染类型基本相似,由最初的膜孔堵塞过渡到最终的滤饼层污染。SEM分析表明,生物聚合铁预处理水样的膜污染较为严重。  相似文献   

16.
聚合氯化铝铁的形态分布对微污染源水混凝效果的影响   总被引:2,自引:0,他引:2  
针对微污染源水中浊度、叶绿素a等的强化去除问题,研究了碱化度、铝铁比和加碱方式等对聚合氯化铝铁形态分布的影响,并考察了形态分布与混凝除污效率和混凝沉淀出水中残铝浓度的关系.结果表明:在铁摩尔分数一定时,混凝剂中单体、中等聚合物和无定形凝胶含量与碱化度存在线性相关性,并推导出中等聚合物含量的计算公式;在碱化度一定时,混凝剂中单体、中等聚合物和无定形凝胶含量与铁摩尔分数也存在线性相关性;增加碱化度或降低铁摩尔分数,可以增加中等聚合物含量、降低单体含量,从而影响混凝除污效率和混凝沉淀后出水中残铝浓度.混凝实验结果表明,混凝过程中叶绿素a去除率和浊度去除率均与混凝剂中中等聚合物含量存在线性相关性,但两者相关系数不同.混凝沉淀后出水中残铝浓度与混凝剂中单体含量存在线性相关性.因此,预聚合的无机高分子混凝剂对提高混凝过程中的除浊、除藻效率,降低混凝沉淀后出水中残铝浓度具有重要的意义.  相似文献   

17.
Natural organic matter (NOM) is found in all surface, ground and soil waters. During recent decades, reports worldwide show a continuing increase in the color and NOM of the surface water, which has an adverse affect on drinking water purification. For several practical and hygienic reasons, the presence of NOM is undesirable in drinking water. Various technologies have been proposed for NOM removal with varying degrees of success. The properties and amount of NOM, however, can significantly affect the process efficiency. In order to improve and optimise these processes, the characterisation and quantification of NOM at different purification and treatment processes stages is important. It is also important to be able to understand and predict the reactivity of NOM or its fractions in different steps of the treatment. Methods used in the characterisation of NOM include resin adsorption, size exclusion chromatography (SEC), nuclear magnetic resonance (NMR) spectroscopy, and fluorescence spectroscopy. The amount of NOM in water has been predicted with parameters including UV-Vis, total organic carbon (TOC), and specific UV-absorbance (SUVA). Recently, methods by which NOM structures can be more precisely determined have been developed; pyrolysis gas chromatography-mass spectrometry (Py-GC-MS), multidimensional NMR techniques, and Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS). The present review focuses on the methods used for characterisation and quantification of NOM in relation to drinking water treatment.  相似文献   

18.
强化混凝去除尖针杆藻   总被引:2,自引:0,他引:2  
嘉陵江水系藻类暴发,水源水中的藻类在水厂前处理工艺中难以去除,造成该流域附近10余个水厂发生滤池堵塞现象,其中个别水厂滤池反冲洗周期由正常情况的24 h缩短至2~3 h,严重影响净水厂的正常运行,使得制水能力大幅降低。针对藻类(优势藻为硅藻中的针杆藻)暴发问题,通过对比PAFS、PAC和PFC3种混凝剂的除藻除浊效果,选取PAFS为最佳混凝剂;通过添加预氧化剂和助凝剂强化混凝除藻效果,其结果表明,使用助凝剂PDMDAAC的对PAFS的助凝效果最好,其余药剂结合PAFS的除藻效果为PPC〉ClO2〉PAM〉H2O2〉HCA-1,并将其应用到现有水厂,结果表明,0.6mg/L PDMDAAC+25 mg/L PAFS在水厂混凝沉淀,尖针杆藻含量降至49×104~55×104cells/L,其除藻率可达70%~75%,大大减轻了滤池的运行负荷,使得水厂运行恢复到正常水平。  相似文献   

19.
Sinha S  Yoon Y  Amy G  Yoon J 《Chemosphere》2004,57(9):1115-1122
Polymeric forms of metal coagulants in water treatment have become increasingly used due to their wider availability and reduction in cost. These specialized coagulant forms and products are claimed by manufacturers to be superior to conventional coagulants in particulate and/or organic removal with inherent advantages of lower alkalinity consumption and lesser sludge production. However, due to their proprietary nature, little is known about their chemical composition. To determine and understand the effectiveness of these alternative coagulants, a comprehensive study was undertaken to characterize metal coagulants, and to comparatively evaluate them on a well-characterized source water. The objective of this study was to provide a scheme for utilities that could be employed as a screening process and a method of selecting an appropriate coagulant based on raw water characteristics and insight into the coagulatability of the source water. Characterizations of coagulants included: (i) active metal content, (ii) anion content, (iii) acidity, (iv) alkalinity consumption, (v) charge reversal by colloidal titration, and (vi) molecular weight determination. A total of five poly-aluminum chlorides (PACl), along with a conventional coagulant (aluminum sulfate or alum) were evaluated. Results show that through the characterization scheme, an effective coagulant (conventional versus alternative) and coagulant type (among various PACl) can be chosen before undertaking time-consuming bench or pilot-scale evaluation.  相似文献   

20.
Relatively "old" (stabilized) landfill leachates are a special category of wastewaters, which are difficult to treat further, mainly due to their bio-refractory organic content (humic substances). In this study, coagulation-flocculation was examined as post-treatment method for the biologically pre-treated stabilized leachates. The purpose was to examine the coagulation performance of alternative coagulant agents, i.e. the composite coagulant polyaluminium silicate chloride. Composite coagulants with different Al to Si molar ratio and different preparation methods were tested. Their efficiency was evaluated by monitoring from turbidity and phosphate content, other parameters strongly correlated with the presence of organic matter, such as UV absorbance at 254nm, COD and colour. The results suggest that the silica-based coagulants exhibit better coagulation performance, than the relevant conventional coagulant (alum) or simple pre-polymerized coagulants (PACl). Polyaluminium silicate chloride has greater tolerance against pH variation than alum or PACl, whereas this novel coagulant works better at pH values between 7 and 9. Coagulation-flocculation has proved to be an efficient post-treatment method for the biologically pre-treated leachates, promoting the removal of the refractory humic substances, while the treatment efficiency of coagulation can be improved by the application of the new coagulant agent.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号