首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
ABSTRACT

The size range of airborne particles that is closely related to specific deposition regions in the human respiratory tract and excess lung burden of these deposited particles is associated with disease. Size-selective sampling, therefore, needs to be performed to assess the related health risks. Performance criteria applied to these samplers must be well characterized in order to provide accurate and reliable results. The PM10 samplers that have been used in place of the total suspended particulate samplers for the collection of ambient air particles are more relevant to potential inhalation hazards. In order to be certified, a PM10 sampler must meet reliable performance specifications, primarily the aerosol penetration test with liquid and solid particles in a wind tunnel (wind speeds of 2, 8, and 24 km/hr). This testing is intended to assure reasonable accuracy in aerosol measurements. However, the sampler performance under calm air conditions has not been well studied.

In the present study, the sampling heads of three devices—the Harvard impactor, the Personal Environmental Monitor (PEM), and the Sierra Andersen model 241 dichotomous sampler PM10 inlet head—were tested for aerosol separation efficiency. With the consideration of bias and imprecision of the measurements, five specimens of each type of sampler were chosen for performance testing, repeating the tests 5 times for each specimen. An ultrasonic atomizing nozzle was used to nebulize potassium sodium tartrate tetrahydrate and dioctyl phthalate particles as the solid and liquid challenge aerosols, respectively. The aerosol number concentrations and size distributions upstream and downstream of the samplers were measured by using an aerosizer calibrated against a settling velocity chamber. The results showed that among the samplers tested, the dichotomous sampler PM10 inlet head had the best fit to the PM10 convention, while the other two samplers not only appeared to have a steeper separation-curve slope but also had significant particle bounce when challenged with solid particles. Analysis of variance also confirmed the superiority of the dichotomous samplers. Surface-coating with oil or grease greatly reduced the problem of particle bounce.  相似文献   

2.
In 1996 a program was started, financed by the Environmental Ministry of Portugal and IAEA, aiming to study the inorganic atmospheric pollutant dispersion in Sado Estuary. Gent PM10 air samplers were used for air particulate matter sampling. Three sampling sites were chosen, forming a triangle around the fuel power station of Setúbal. Transplants of Parmelia sulcata Taylor were suspended in nylon bags within a rectangle 15 km wide and 25 km long on a 2.5 x 2.5 km grid. Two sets of four transplants were hung in each of the 47 locations, one set facing the wind and the other set opposing the wind. The transplants were suspended in December 1997 for a 1-year period; every 3 months, one transplant of each set was collected. Both lichen transplants and PM10 filters were analysed by INAA and PIXE. A comparative study of results obtained for the two sampling procedures is presented in this work.  相似文献   

3.
The objectives of this paper are to contrast the relative variability of replicate laboratory measurements of selected chemical components of fine particulate matter (PM) with total variability from collocated measurements and to compare the magnitudes of the uncertainties determined from collocated sampler data with those currently being provided to U.S. Environmental Protection Agency (EPA)'s Air Quality System (AQS) database by RTI International (RTI). Pointwise uncertainty values are needed for modeling and data analysis and should include all the random errors affecting each data point. Total uncertainty can be decomposed into two primary components: analytical measurement uncertainty and sampling uncertainty. Analytical measurement uncertainties are relatively easy to calculate from routine quality control (QC) data. Sampling uncertainties, on the other hand, are comparatively difficult to measure. In this paper, the authors describe data from collocated samplers to provide a snapshot of whole-system uncertainty for several important chemical species. The components of uncertainty were evaluated for key species from each of the analytical methods employed by the PM2.5 Speciation Trends Network (STN) program: gravimetry, ion chromatography (IC), X-ray fluorescence (XRF), and thermal-optical analysis for organic carbon and elemental carbon. The results show that the laboratory measurement uncertainties are typically very small compared with uncertainties calculated from the differences between samples collected from collocated samplers. These differences are attributable to the "field" components uncertainty, which may include contamination and/or losses during shipping, handling, and sampling, as well as other distortions of the concentration level due to flow and sample volume variations. Uncertainties calculated from the collocation results were found to be generally similar to the uncertainties currently being loaded into EPA's AQS system, with some exceptions described below.  相似文献   

4.
An investigation of high volume particle sampling and sample handling procedures was undertaken to evaluate variations of protocols being used by the U.S. Environmental Protection Agency. These protocols are used in urban ambient air studies which collect ambient and source samples for subsequent mutagenicity analysis of the organic extracts of the aerosol fraction. Specific protocol issues investigated include: (a) duration of sampling period, (b) type of filter media used to collect air particles, (c) necessity for cryogenic field site storage and dry ice shipping of filter samples, and (d) sample handling at the receiving laboratory. Six PM10 Hi-Vol samplers were collocated at an urban site in downtown Durham, North Carolina and operated simultaneously to evaluate 12 h versus 24 h collection periods and filter media choices of glass fiber, Teflon impregnated glass fiber (TIGF), and quartz fiber. Filters from the samplers plus field blanks were collected during each of 25 sampling periods. TIGF filters from two samplers were immediately placed on dry ice in the field and transported directly to cryogenic storage. TIGF, quartz, and glass fiber filters from three samplers were transported at ambient and maintained at room temperature for three to six days prior to cryogenic storage. One TIGF sample, which was collected on a previously tared filter, was subjected to controlled environment equilibration (40 percent relative humidity, 22 degrees C) for 8 to 24 h and weighed prior to cryogenic storage. All filters were subsequently stored at -70 degrees C to -80 degrees C prior to a one-time extraction and Salmonella (Ames) mutagenicity bioassay of the entire sample set.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

5.
Abstract

This study is a part of an ongoing investigation of the types and locations of emission sources that contribute fine particulate air contaminants to Underhill, VT. The air quality monitoring data used for this study are from the Interagency Monitoring of Protected Visual Environments network for the period of 2001–2003 for the Underhill site. The main source-receptor modeling techniques used are the positive matrix factorization (PMF) and potential source contribution function (PSCF). This new study is intended as a comparison to a previous study of the 1988–1995 Underhill data that successfully revealed a total of 11 types of emission sources with significant contributions to this rural site. This new study has identified a total of nine sources: nitrate-rich secondary aerosol, wood smoke, East Coast oil combustion, automobile emission, metal working, soil/dust, sulfur-rich aerosol type I, sulfur-rich aerosol type II, and sea salt/road salt. Furthermore, the mass contributions from the PMF identified sources that correspond with sampling days with either good or poor visibility were analyzed to seek possible correlations. It has been shown that sulfur-rich aerosol type I, nitrate aerosol, and automobile emission are the most important contributors to visibility degradation. Soil/dust and sea salt/road salt also have an added effect.  相似文献   

6.
ABSTRACT

Acidic aerosol concentrations measured by an annular denuder system (ADS) and a honeycomb denuder system (HDS) in Hsinchu, Taiwan, were compared. Aerosols were also sampled by a MOUDI (micro-orifice uniform deposit impactor) and analyzed by an ion chromatograph to determine the size distributions of different species. Using the measured aerosol size distribution, theoretical analysis showed that positive HNO3 artifact due to volatiliza-tion of NH4NO3 is generally negligible for both samplers.4 3Comparing two different denuder samplers, the average concentration of HNO3 measured by the ADS was found3to be lower than that measured by the HDS, while the difference between the two samplers for the average concentration of other species was found to be within ±15%. A possible cause of the difference in HNO3 con-3centrations is due to a greater loss of HNO3 in the cyclone3 used by the ADS than in the impactor used by the HDS. The study also showed incomplete absorption of the evaporated HCl and HNO3 from the particles on the Teflon3filter by the first nylon filter in the filter pack of the ADS. Collection efficiency and capacity of HCl and HNO3 by3the nylon filters need further investigation.  相似文献   

7.
A systematic method combining water and diluted-acid extractions has been developed for the manifold evaluation of soluble and insoluble fractions in ambient aerosol. The pre-washed regenerated cellulose membrane filter was used as a collection medium of a low-volume air sampler. The collection time of 7–14 days was required to obtain the sample amounts enough for the systematic analysis. Simple and efficient extraction procedures using the filtration of water and 0.1 M hydrochloric acid were recommended in order to obtain the information about the dissolution behaviors of various elements in the aerosol. Soluble components in both the extracts were determined by inductively coupled plasma atomic emission spectrometry (ICP-AES) and ion chromatography (IC). These extraction procedures were also preferred to prepare thin-layer specimens suitable to the succeeding X-ray fluorescence spectrometry (XRF) for insoluble components. Elemental compositions of the extraction residues were conveniently determined by the XRF calibrated with thin-layer standard specimens prepared with activated carbon. The determination of the 17 representative elements (Na, Mg, Al, Si, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Cu, Zn, Br, Pb) in these three fractions from an aerosol sample was performed rapidly within 4 h. The proposed systematic method was applied to PM2.5 and PM10 aerosol samples collected in Kofu City, Central Japan, and the enrichment behaviors of various elements and their source apportionment such as soil, anthropogenic substances and vehicle exhaust particulates could be demonstrated by the present method.  相似文献   

8.
Epiphytic lichen transplants and aerosol samplers were put together in the Setubal area, Portugal. They were analysed by Instrumental Neutron Activation Analysis (INAA) and Proton Induced X-ray Emission (PIXE). The lichen dataset pointed out nine factors. No relevant differentiation was found towards different positioning of the lichens. T-transplants were delayed towards F-transplants, and for both after 3 and 6 months the accumulation was as much as at 9th month. Direct rainfall protection favoured accumulation for a few elements only. The elemental accumulation in lichens depended more on temperature and humidity conditions. Aerosol data towards lichen database showed an excellent correlation.  相似文献   

9.
An investigation of high volume particle sampling and sample handling procedures was undertaken to evaluate variations of protocols being used by the U.S. Environmental Protection Agency. These protocols are used in urban ambient air studies which collect ambient and source samples for subsequent mutagenicity analysis of the organic extracts of the aerosol fraction. Specific protocol issues investigated include: (a) duration of sampling period, (b) type of filter media used to collect air particles, (c) necessity for cryogenic field site storage and dry ice shipping of filter samples, and (d) sample handling at the receiving laboratory. Six PM10 Hi-Vol samplers were collocated at an urban site in downtown Durham, North Carolina and operated simultaneously to evaluate 12 h versus 24 h collection periods and filter media choices of glass fiber, Teflon® impregnated glass fiber (TIGF), and quartz fiber. Filters from the samplers plus field blanks were collected during each of 25 sampling periods. TIGF filters from two samplers were immediately placed on dry ice in the field and transported directly to cryogenic storage. TIGF, quartz, and glass fiber filters from three samplers were transported at ambient and maintained at room temperature for three to six days prior to cryogenic storage. One TIGF sample, which was collected on a previously tared filter, was subjected to controlled environment equilibration (40 percent relative humidity, 22°C) for 8 to 24 h and weighed prior to cryogenic storage. All filters were subsequently stored at ?70°C to ?80°C prior to a one-time extraction and Salmonella (Ames) mutagenicity bioassay of the entire sample set. Results indicate that the sample handling variations and collection period variables had no significant effect on recovery of organics or mutagens. However, a filter type difference was observed. The sonication extraction of organics and mutagens was significantly greater for TIGF filters than for glass fiber or quartz. Results from a second phase of study indicated differences in extracted organics and mutagens for these filter types.  相似文献   

10.
ABSTRACT

To investigate the chemical characteristics of fine particles in the Sihwa area, Korea, atmospheric aerosol samples were collected using a dichotomous PM10 sampler and two URG PM2.5 cyclone samplers during five intensive sampling periods between February 1998 and February 1999. The Inductively Coupled Plasma (ICP)-Atomic Emission Spectrometry (AES)/ICP-Mass Spectrometry (MS), ion chromatograph (IC), and thermal manganese dioxide oxidation (TMO) methods were used to analyze the trace elements, ionic species, and carbonaceous species, respectively. Backward trajectory analysis, factor analysis, and a chemical mass balance (CMB) model were used to estimate quantitatively source contributions to PM2 5 particles collected in the Sihwa area.

The results of PM2.5 source apportionment using the CMB7 receptor model showed that (NH4)2SO4 was, on average, the major contributor to PM2.5 particles, followed by nontraffic organic carbon (OC) emission, NH4NO3, agricultural waste burning, motor vehicle emission, road dust, waste incineration, marine aerosol, and others. Here, the nontraffic OC sources include primary anthropogenic OC emitted from the industrial complex zone, secondary OC, and organic species from distant sources. The source impact of waste incineration emission became significant when the dominant wind directions were from southwest and west sectors during the sampling periods. It was found that PM2.5 particles in the Sihwa area were influenced mainly by both anthropogenic local sources and long-range transport and transformation of air pollutants.  相似文献   

11.
The size range of airborne particles that is closely related to specific deposition regions in the human respiratory tract and excess lung burden of these deposited particles is associated with disease. Size-selective sampling, therefore, needs to be performed to assess the related health risks. Performance criteria applied to these samplers must be well characterized in order to provide accurate and reliable results. The PM10 samplers that have been used in place of the total suspended particulate samplers for the collection of ambient air particles are more relevant to potential inhalation hazards. In order to be certified, a PM10 sampler must meet reliable performance specifications, primarily the aerosol penetration test with liquid and solid particles in a wind tunnel (wind speeds of 2, 8, and 24 km/hr). This testing is intended to assure reasonable accuracy in aerosol measurements. However, the sampler performance under calm air conditions has not been well studied. In the present study, the sampling heads of three devices--the Harvard impactor, the Personal Environmental Monitor (PEM), and the Sierra Andersen model 241 dichotomous sampler PM10 inlet head--were tested for aerosol separation efficiency. With the consideration of bias and imprecision of the measurements, five specimens of each type of sampler were chosen for performance testing, repeating the tests 5 times for each specimen. An ultrasonic atomizing nozzle was used to nebulize potassium sodium tartrate tetrahydrate and dioctyl phthalate particles as the solid and liquid challenge aerosols, respectively. The aerosol number concentrations and size distributions upstream and downstream of the samplers were measured by using an aerosizer calibrated against a settling velocity chamber. The results showed that among the samplers tested, the dichotomous sampler PM10 inlet head had the best fit to the PM10 convention, while the other two samplers not only appeared to have a steeper separation-curve slope but also had significant particle bounce when challenged with solid particles. Analysis of variance also confirmed the superiority of the dichotomous samplers. Surface-coating with oil or grease greatly reduced the problem of particle bounce.  相似文献   

12.
ABSTRACT

Chemical composition data for fine and coarse particles collected in Phoenix, AZ, were analyzed using positive matrix factorization (PMF). The objective was to identify the possible aerosol sources at the sampling site. PMF uses estimates of the error in the data to provide optimum data point scaling and permits a better treatment of missing and below-detection-limit values. It also applies nonnegativity constraints to the factors. Two sets of fine particle samples were collected by different samplers. Each of the resulting fine particle data sets was analyzed separately. For each fine particle data set, eight factors were obtained, identified as (1) biomass burning characterized by high concentrations of organic carbon (OC), elemental carbon (EC), and K; (2) wood burning with high concentrations of Na, K, OC, and EC; (3) motor vehicles with high concentrations of OC and EC; (4) nonferrous smelting process characterized by Cu, Zn, As, and Pb; (5) heavy-duty diesel characterized by high EC, OC, and Mn; (6) sea-salt factor dominated by Na and Cl; (7) soil with high values for Al, Si, Ca, Ti, and Fe; and (8) secondary aerosol with SO4 -2 and OC that may represent coal-fired power plant emissions.

For the coarse particle samples, a five-factor model gave source profiles that are attributed to be (1) sea salt, (2) soil, (3) Fe source/motor vehicle, (4) construction (high Ca), and (5) coal-fired power plant. Regression of the PM mass against the factor scores was performed to estimate the mass contributions of the resolved sources. The major sources for the fine particles were motor vehicles, vegetation burning factors (biomass and wood burning), and coal-fired power plants. These sources contributed most of the fine aerosol mass by emitting carbonaceous particles, and they have higher contributions in winter. For the coarse particles, the major source contributions were soil and construction (high Ca). These sources also peaked in winter.  相似文献   

13.
Abstract

Because the particulate organic carbon (OC) concentrations reported in U.S. Environment Protection Agency Speciation Trends Network (STN) data were not blank corrected, the OC blank concentrations were estimated using the intercept in particulate matter ≤2.5 µm in aerodynamic diameter (PM2.5) regression against OC concentrations. The estimated OC blank concentrations ranged from 1 to 2.4 μg/m3 showing higher values in urban areas for the 13 monitoring sites in the northeastern United States. In the STN data, several different samplers and analyzers are used, and various instruments show different method detection limit (MDL) values, as well as errors. A comprehensive set of error structures that would be used for numerous source apportionment studies of STN data was estimated by comparing a limited set of measured concentrations and their associated uncertainties. To examine the estimated error structures and investigate the appropriate MDL values, PM2.5 samples collected at a STN site in Burlington, VT, were analyzed through the application of the positive matrix factorization. A total of 323 samples that were collected between December 2000 and December 2003 and 49 species based on several variable selection criteria were used, and eight sources were successfully identi?ed in this study with the estimated error structures and min values among different MDL values from the ?ve instruments: secondary sulfate aerosol (41%), secondary nitrate aerosol (20%), airborne soil (15%), gasoline vehicle emissions (7%), diesel emissions (7%), aged sea salt (4%), copper smelting (3%), and ferrous smelting (2%). Time series plots of contributions from airborne soil indicate that the highly elevated impacts from this source were likely caused primarily by dust storms.  相似文献   

14.
Abstract

The São Paulo Metropolitan area (SPMA) is characterized as having one of the worst air pollution problems in Brazil,with frequent violations of air quality standards for particulate matter. This paper presents the results of a eceptor model source apportionment study carried out to develop a quantitative database on which a control strategy could be developed. The study was conducted in four sites with distinct land uses. Fine, coarse (CP), and total suspended particles (TSP) samples were collected on Teflon and glass filters and analyzed by x-ray fluorescence XRF), ion chromatography, and thermal evolution. The sources were characterized by similar methodology. Chemical mass balance (CMB) receptor modeling indicated that carbonaceous material plays an important role in the aerosol composition; that the three major source categories contributing to the fine particles are vehicles, secondary carbon, and sulfates; and that the main contributors to CP and TSP are road dust and vehicles. All sampling sites presented the same general pattern in terms of source contribution, although this contribution varied from site to site.  相似文献   

15.
ABSTRACT

Fine particles in the atmosphere have elicited new national ambient air quality standards (NAAQS) because of their potential role in health effects and visibility-reducing haze. Since April 1997, Tennessee Valley Authority (TVA) has measured fine particles (PM2.5) in the Tennessee Valley region using prototype Federal Reference Method (FRM) samplers, and results indicate that the new NAAQS annual standard will be difficult to meet in this region. The composition of many of these fine particle samples has been determined using analytical methods for elements, soluble ions, and organic and elemental carbon. The results indicate that about one-third of the measured mass is SO4 -2, one-third is organic aerosol, and the remainder is other materials. The fraction of SO4 -2 is highest at rural sites and during summer conditions, with greater proportions of organic aerosol in urban areas throughout the year. Additional measurements of fine particle mass and composition have been made to obtain the short-term variability of fine mass as it pertains to human exposure. Measurements to account for semi-volatile constituents of fine mass (nitrates, semi-volatile organics) indicate that the FRM may significantly under-measure organic constituents. The potentially controllable anthropogenic fraction of organic aerosols is still largely unknown.  相似文献   

16.
To investigate the chemical characteristics of fine particles in the Sihwa area, Korea, atmospheric aerosol samples were collected using a dichotomous PM10 sampler and two URG PM2.5 cyclone samplers during five intensive sampling periods between February 1998 and February 1999. The Inductively Coupled Plasma (ICP)-Atomic Emission Spectrometry (AES)/ICP-Mass Spectrometry (MS), ion chromatograph (IC), and thermal manganese dioxide oxidation (TMO) methods were used to analyze the trace elements, ionic species, and carbonaceous species, respectively. Backward trajectory analysis, factor analysis, and a chemical mass balance (CMB) model were used to estimate quantitatively source contributions to PM2.5 particles collected in the Sihwa area. The results of PM2.5 source apportionment using the CMB7 receptor model showed that (NH4)2SO4 was, on average, the major contributor to PM2.5 particles, followed by nontraffic organic carbon (OC) emission, NH4NO3, agricultural waste burning, motor vehicle emission, road dust, waste incineration, marine aerosol, and others. Here, the nontraffic OC sources include primary anthropogenic OC emitted from the industrial complex zone, secondary OC, and organic species from distant sources. The source impact of waste incineration emission became significant when the dominant wind directions were from southwest and west sectors during the sampling periods. It was found that PM2.5 particles in the Sihwa area were influenced mainly by both anthropogenic local sources and long-range transport and transformation of air pollutants.  相似文献   

17.
Cessna AJ  Waite DT  Kerr LA  Grover R 《Chemosphere》2000,40(8):795-802
The reproducibility of collection of atmospheric residues of the herbicides 2,4-D and triallate as bulk (wet plus dry) deposition samples by paired pan samplers and as particulate (filter) and vapour (PUF/XAD-2 resin cartridge) samples by paired high-volume air samplers was determined. Variability of herbicide concentrations in paired bulk deposition samples was within 25% for 65 and 80% of the samples for 2,4-D and triallate, respectively, with approximately 90% of the paired samples being within a factor of 2 for both herbicides. The vapour samples of 2,4-D and triallate showed similar reproducibilities. The highest reproducibility was observed for the filter samples with 92% of the paired data sets for 2,4-D being within 25% variability. No triallate was detected in the filter samples.  相似文献   

18.
Abstract

Passive samplers have been shown to be an inexpensive alternative to direct sampling. Diffusion denuders have been developed to measure the concentration of species such as ammonia (NH3), which is in equilibrium with particulate ammonium nitrate. Conventional denuder sampling that inherently requires air pumps and, therefore, electrical power. To estimate emissions of NH3 from a fugitive source would require an array of active samplers and meteorological measurements to estimate the flux. A recently developed fabric denuder was configured in an open tube to passively sample NH3 flux. Passive and active samplers were collocated at a dairy farm at the California State University, Fresno, Agricultural Research Facility. During this comparison study, NH3 flux measurements were made at the dairy farm lagoon before and after the lagoon underwent acidification. Comparisons were made of the flux measurements obtained directly from the passive flux denuder and those calculated from an active filter pack sampler and wind velocity. The results show significant correlation between the two methods, although a correction factor needed to be applied to directly compare the two techniques. This passive sampling approach significantly reduces the cost and complexity of sampling and has the potential to economically develop a larger inventory base for ambient NH3 emissions.  相似文献   

19.
We describe a new experimental methodology based on the contemporary use of two-stage continuous streaker samplers and optical particle counters. This is a complementary approach to size-segregated particulate matter (PM) sampling, and it is able to give information on the elemental size distribution and to assess the contribution of major PM source to size bins. PM samples in the fine and coarse fraction of PM10 have been collected by a two-stage streaker sampler and analyzed by particle-induced X-ray emission (PIXE) to obtain elemental concentration time series with hourly resolution. PM sources and profiles were singled out by positive matrix factorization (PMF). A multi-linear regression of size-segregated number of particles versus the sources, resolved by PMF, made possible the apportionment of size-segregated particles number in a fast and direct way. Results obtained in three sampling sites, located in different urban districts are discussed.  相似文献   

20.
The University of Arizona and the Pima County Air Pollution Control District conducted a comparison study of the following aerosol samplers: a standard high-volume sampler, a high-volume sampler fitted with a size selective inlet, and a dichotomous virtual impactor. Over sixty samples were collected with the colocated samplers during the first six months of 1981. The concentration (μg/m3) of suspended particulate matter and of sulfate was determined for all the samples, while the concentration of four lithophilic elements (Ca, Fe, Mg, and K) was determined on one third of the samples. Well-defined linear relationships for suspended particulate matter and sulfate were found to exist between each of the three sample collection methods over the concentrafion range encountered in this study. For these samples, there were significant differences in the particulate mass and large particle lithophilic element concentrations collected by each device. However, sulfate values obtained from the three samplers were in excellent agreement with each other. This suggests that the inlet collection efficiency for large particles differs significantly for these three sampling devices. Since the size selective inlet and the dichotomous virtual impactor samplers are each designed for collection of inhalable particles (particles of 15 μm aerodynamic diameter and smaller), they would have been expected to measure approximately equivalent particle mass concentrations. Thus, these differences are important to those interested in selecting a method for measuring airborne particle mass concentrations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号