首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
以污泥比阻、污泥含水率为污泥脱水评价指标,研究了硫酸与过氧化氢联合调理含铁污泥对污泥脱水性能的影响。实验结果表明,含铁污泥经硫酸与过氧化氢联合调理后,污泥比阻、污泥含水率显著降低,污泥脱水性能得到明显地改善。进一步研究表明,含铁污泥脱水性能的改善可能与污泥中形成的Fenton/类Fenton反应有关。经过单因素实验,确定了最佳反应条件:5 mol·L~(-1)硫酸溶液投加量1.5 mL,30%双氧水投加量0.25 mL,酸化时间25 min,反应时间2 min。在此条件下,污泥比阻由1.82×10~(13)m·kg~(-1)减少至0.74×10~(11)m·kg~(-1)。脱水污泥含水率由89.15%降低至71.12%。  相似文献   

2.
Fe(Ⅱ)活化过硫酸盐改善污泥脱水性能   总被引:1,自引:0,他引:1  
针对污水处理厂剩余污泥脱水困难的问题,采用Fe~(2+)活化过硫酸钾高级氧化法提高剩余污泥脱水性能,使用污泥含水率和污泥比阻对调理前后污泥脱水效果进行分析;研究了过硫酸钾投加量、Fe~(2+)投加量、pH和反应时间对污泥调理效果的影响;探究了过硫酸盐调理污泥过程中溶解性有机物质和胞外聚合物(extracellular polymeric substance,EPS)的变化特性。结果表明:过硫酸钾调理的最佳反应条件为pH=7.5,反应时间为20 min,过硫酸钾和Fe~(2+)的最佳投加量分别为15 mmol·L~(-1)和18 mmol·L~(-1),在此条件下,污泥含水率和污泥比阻值分别可达78.89%和0.3×10~(12) m·kg~(-1);污泥含水率和比阻的变化可能与污泥调理后絮体结构形态变化有关;调理污泥后,上清液中溶解性有机物质含量与过硫酸钾投加量呈显著正相关关系,而EPS不同组分中蛋白质和多糖含量在Fe~(2+)投加后均减少,表明Fe~(2+)的投加可以破坏污泥絮体,分解胞内物质;利用Fe~(2+)激活过硫酸钾所生成的硫酸根自由基可极大改善污泥的脱水性能。  相似文献   

3.
污泥经过CaO_2联合絮凝剂处理后,其脱水性能得到明显改善。采用改变初始pH、调理剂投加量以及改变调理剂投加顺序的方法,调理污泥改善脱水性能;采用Zeta电位、激光粒度、胞外聚合物及结合水分析对调理前后的污泥进行了表征;研究了调理剂不同投加量对污泥脱水性能的影响;探讨了不同调理剂下污泥脱水机理。结果表明:CaO_2联合絮凝剂(微生物絮凝剂或壳聚糖)明显改善污泥脱水降低污泥含水率;CaO_2联合絮凝剂调理后的污泥粒径和Zeta电位均有所减小,并且CaO_2在絮凝剂之前投加,降低幅度更加明显;先投加CaO_2,污泥层状结构会在氧化作用下发生裂解破碎,形成不规则的小絮体,使污泥破坏得更彻底;在絮凝剂之前投加CaO_2,污泥经过处理后的可溶性糖类和可溶性蛋白质的浓度增加,而结合的糖类、蛋白质及结合水的变化量却减小。因此,CaO_2联合絮凝剂可以优化污泥脱水性能,且CaO_2与絮凝剂的投加顺序对于污泥脱水有显著影响。  相似文献   

4.
以污水处理厂浓缩池污泥为研究对象,用污泥比阻、污泥含水率和污泥粘度评价污泥脱水性能,研究亚铁离子活化过硫酸盐氧化法对污泥脱水性能的影响。结果表明,单独投加过硫酸钾时,污泥比阻和含水率随过硫酸钾投加量的增加稍有下降。投加硫酸亚铁和过硫酸钾时,温度对污泥脱水性能影响不大。污泥脱水性能最佳的条件:在常温下,污泥p H为7,硫酸亚铁投加量为1.5 mmol/g VSS、过硫酸钾投加量为1.2 mmol/g VSS,亚铁离子和过硫酸根的摩尔比为1.25∶1,污泥的比阻从5.36×1012m/kg降低到1.9×1011m/kg,含水率从97.0%降低到81.6%,粘度从178 m Pa·s降低到102 m Pa·s。  相似文献   

5.
利用金刚石生产废物叶腊石耦合微波对燃料乙醇厌氧消化污泥(FEADS)进行处理,探讨该处理方法对FEADS脱水性能的改善效果及机理。结果表明:含水率为97.65%的FEADS,投加叶腊石粉(2g/L)后沉降性能大幅提高,20 min时沉降比(SV)由70.2%减小为54.3%;经叶腊石粉(2g/L)耦合微波(640W、2min)处理后脱水性能大幅提高,污泥比阻(SRF)由1.21×10~(13)m/kg减小为7.23×10~(12) m/kg,可压缩系数由1.33减小为0.63;扫描电镜表明,叶腊石耦合微波处理后FEADS水分容易通过;热重曲线中失重峰明显滞后,显示叶腊石耦合微波处理改善了FEADS的脱水性能。  相似文献   

6.
为研究污泥石灰低温干燥特性,分别向脱水污泥中投加0%、3%、5%、7%、10%、12%和15%的石灰,对投加石灰后污泥低温干燥过程中含水率和干燥速率变化进行了研究,并对干燥后冷凝液的性质进行了分析。结果表明:低温条件下,向污泥中投加石灰后,污泥干燥过程中的含水率迅速降低,石灰投加比与混合后污泥初始含水率呈线性关系,与污泥临界含水率呈二次函数关系;投加石灰可以提高污泥的最大干燥速率;用干污泥代替部分石灰对污泥进行干燥,既可降低成本,又不影响干燥效率;污泥石灰低温干燥的冷凝液呈弱碱性,随着石灰投加比的增加,冷凝液中COD和TOC浓度降低,NH+4-N浓度略有升高,但冷凝液中污染物浓度均较低,可不经处理直接排入城镇污水处理系统。  相似文献   

7.
为研究磁场对市政污泥脱水性能的影响,通过自主研制的磁场装置,开展了4种不同含水率(99.15%、97.41%、95.52%和93.73%)的市政污泥的磁场处理实验。实验结果表明:市政污泥经过磁场处理后脱水性能显著改善;高含水率下的污泥在磁场作用下脱水性能改善效果比低含水率好,在4种含水率下市政污泥的毛细吸水时间最大依次降低了90.5%、65.8%、61.6%和51.6%;通过实验数据优化分别得出4种含水率下污泥的最佳磁场处理强度和最佳磁场作用时间,且磁场强度、磁场作用时间与市政污泥含水率均呈二次多项式的关系;磁场处理对污泥离心脱水有影响,市政污泥经过磁场处理比未经过磁场处理的离心脱水含水率降低了约0.6%;建议在市政污泥脱水工艺中可考虑磁场与其他预处理工艺联合处理的方法以前达到更好的脱水效果。  相似文献   

8.
污泥在污水厂厌氧消化和离心脱水后,一般含水率在80%~85%,为了后期有效的处理处置,需要进行深度脱水。实验采用化学干化法,投加不同比例的粉煤灰与生石灰复合调理剂,测定调理后污泥的含水率、脱水过滤速度和pH。实验结果表明,粉煤灰与生石灰复合调理剂可以有效改善污泥脱水性能,使泥饼含水率降低到60%以下,同时将污泥抽滤的脱水时长从20 min降至6 min内。此外,适当比例的复合调理剂可以大大降低污泥的pH,减小污泥后期处置带来的环境污染。  相似文献   

9.
污泥屏障通过物理拦截以及化学作用可以有效控制重金属离子迁移,采用污泥屏障处理酸性矿山废水(AMD)已被证明具有可行性.作为尾矿渣处置场屏障的主体材料,研究污泥压缩特性很有必要.实验结果表明,对于含水率相同的压实污泥试样,孔隙比随干密度增大而减小,最终趋于1;干密度相同的试样,最优含水率的孔隙比随应力增大减小最快.试样压缩系数随干密度增大而减小,随含水率增大先增大后减小,最优含水率的压缩系数为0.8 MPa-1.AMD溶液作孔隙液能提高试样压缩系数.通过对比分析有机质土的压缩特性,为以后的深化研究提供相关参数支持.  相似文献   

10.
热调质方法是污泥深度脱水的有效办法之一。研究结果表明,污泥热调质过程中反应温度和反应时间对污泥热调质效果影响较大,搅拌速度影响较小。当反应温度从160℃升至180℃,反应时间从30 min增至60 min时,污泥溶液中挥发性悬浮固体(VSS)急剧溶解,释放出细胞里的结合水,表明污泥细胞破壁的温度条件为160~180℃,时间条件为45~60 min。热调质后污泥的比阻变化较大。随着反应温度的不断提高,比阻不断减小,污泥的脱水性能越来越好。实验确定了污泥热调质的最佳反应条件为:反应温度180℃,反应时间60 min,搅拌转速30 r/min。在此条件下,压滤后泥饼含水率约50%,滤液中COD浓度可达19 000 mg/L,有利于后续污泥的消化。  相似文献   

11.
湿污泥在流化床中干燥特性   总被引:1,自引:1,他引:0  
在鼓泡流化床干燥器内,床料采用0~1 mm的石英砂,以热空气作为干燥介质,对城市污水污泥的流态化干燥特性进行实验研究。通过控制送风温度、流化风量、加料量、污泥粒径等参数,研究在不同工况条件下床温以及干污泥含水率的变化情况。结果表明,随着送风温度的升高,床温升高,干污泥含水率下降,最终趋向于一个稳定值8%。床温随流化风量的增加先是减小而后升高,干污泥的含水率随流化风量的增加先是降低而后增大。当加料量从11 kg/h增加到13kg/h时,干污泥的含水率基本没有变化,当加料量超过13 kg/h时,干污泥的含水率从8.1%开始呈递增趋势。随污泥粒径的增大,床温升高,干污泥含水率也随之升高。  相似文献   

12.
用额定电压为220 V、振荡频率为2 450 MHz、输出功率为800 W的微波炉对5~30 g城市污泥辐照2~30 min。由不同时间对城市污泥进行微波辐照后的质量损失率、残余湿度以及挥发性固体(VS)含量的变化表明:用微波炉可简便、快速地测定城市污泥的湿度。为提高微波炉测定湿度的准确性,应减少取样量,进行重复辐照,并根据相邻2次辐照导致的质量变化幅度逐次缩短辐照时间;在辐照过程中应避免引起样品突然释放大量VS,辐照至恒重为止。  相似文献   

13.
Reusing sewage sludge as a soil fertiliser has become a common alternative to disposal. Although this practice has a few benefits, it may contribute to the medium- and long-term contamination of the trophic chain because sewage sludge may contain heavy metals and organic contaminants. As the leaching of contaminants may depend on the sludge pre-treatment, the leaching of heavy metals (Cu, Ni, Pb, Zn and Cr) and alkylphenolic compounds (APCs) (octylphenol (OP), nonylphenol (NP), nonylphenol-mono-ethoxylate (NP1EO)) was investigated in five fresh and 40 °C dried sewage sludge samples from north-eastern Spain. FT-IR analyses and full-scan GC-MS chromatograms showed that sludge drying changed the nature of organic compounds leading to changes in their solubility. Moreover, sludge drying led to a higher relative contribution of dissolved organic carbon than the particulate organic carbon in the leachates. Leaching of Pb, Zn and Cr was below 5 % in both fresh and dried sludge samples, whereas Cu and Ni leached at rates up to 12 and 43 %, respectively, in some of the dried sludge samples. The leaching yields of OP, NP and NP1EO ranged from 1.3 to 35 % for fresh samples, but they decreased from 0.8 to 3.4 % in dried samples. The decrease in the leachability of APCs observed in dried sludge samples might be attributed to the fact that these compounds are associated with particulate organic matter, with significantly lower concentration or even absent in dried sludge than in fresh sludge samples. Therefore, it is recommended to dry the sludge before its disposal.  相似文献   

14.
黄程兰  陈滢  刘敏 《环境工程学报》2012,6(11):3894-3898
污泥膨胀是活性污泥工艺运行中经常遇到的最棘手的问题之一。本实验以人工合成污水为底物,采用序机式活性污泥法(SBR);研究投加无机混凝剂氯化钙控制污泥膨胀的情况,同时研究丝状菌和菌胶团的变化。研究发现,投加氯化钙后,丝状菌数量明显减少;形成较多大而密实规则的菌胶团,污泥膨胀得到控制。污泥容积指数(SVI)由最初的309.5 mL/g降到67.1 mL/g,污泥沉降性能改善。停止投加氯化钙后又运行了18周期,活性污泥没有发生再次膨胀。投加氯化钙对COD去除率没有明显影响。研究结果表明,投加氯化钙是一种有效的污泥膨胀应急控制措施。  相似文献   

15.
市政污泥强化脱水实验研究   总被引:2,自引:0,他引:2  
通过对市政污泥进行超声处理、絮凝剂处理和超声结合絮凝剂处理,研究不同条件下污泥上清液的COD浓度、粒度分布及微观结构变化情况。实验结果表明,超声波作用可以调整污泥结构,改善污泥脱水性能;当超声时间达到20min左右时,脱水效果最好为87.9%;超声波作用使污泥中释放的COD浓度增加至91.2 mg/L;污泥颗粒粒度发生变化,分布在易脱水段10~100μm的更多。  相似文献   

16.
Enhanced treatments of sewage sludge produce a more manageable product for agricultural use by stabilizing the material, removing water, and reducing the possibility of pathogen transfer. We investigated the impact of pilot-scale composting and drying of sludge on physicochemical characteristics and on the concentrations of some organic contaminants. During the 143 day composting procedure, organic matter fell 22% and moisture by half. Concentrations of 4-nonylphenols (4-NPs) fell by 88% and di-(2-ethylhexyl) phthalate (DEHP) by 60%; losses continued throughout the procedure. Losses of total polychlorinated biphenyls (PCBs) were 11%, mostly from the lower molecular weight congeners, suggesting volatilization as the most likely loss mechanism. The drying process was much shorter, 40 days, yet organic matter content decreased by 27% and moisture by 85%. Losses of 4-NPs (39%) and DEHP (22%) were less than in composting and stopped when moisture content became constant. There were no losses of PCBs. Both treatments are simple, practical procedures that reduce the volume of waste and are applicable in situ on farms. Composting would be the method of choice for reducing organic contaminants but requires much longer times than drying.  相似文献   

17.
Washing of cadmium contaminated soil and sludge using a mixture of 0.1 M Na2S2O5 and 0.01 M Na2EDTA was investigated in the batch mode. Initial Cd concentration in samples was 500 mg kg−1. The sequential extraction was conducted to study of what form that Cd was removed. SPSS program version 9.01 was performed to determine what soil parameter had the greatest influence on the washing. The organic matter in soil was found to be the main factor for the washing. Soil with low organic matter would have high percentage of removing Cd. When adding more washing solution, the Cd removal efficiency was lower. The highest removal efficiency was between 67.83% and 97.3% when using a 1 g:2.5 ml soil to washing solution ratio. The predominant form of the removed Cd was exchangeable form. By contrast for the sludge, the highest Cd removal efficiency was 17.13% when using sludge in washing solution at the ratio of 1 g:7.5 ml. Most of washed Cd was in reducible form.  相似文献   

18.
污水污泥有机调质浓缩和无机调质脱水工艺研究   总被引:2,自引:0,他引:2  
介绍了一种污水污泥有机调质浓缩和无机调质脱水工艺,它可有效提高污泥浓缩和脱水效率。含水率99%以上的剩余污泥经过有机调质后可快速浓缩至含水率93%左右,去除污泥中的间隙水和表面吸附水。浓缩污泥经过无机调质后可板框压滤脱水至含水率60%左右,脱除污泥中的毛细结合水和部分细胞水,而且实现了污泥重金属的稳定化。  相似文献   

19.
赤泥投加控制河道底泥磷释放的影响因素   总被引:1,自引:1,他引:0  
通过对不同赤泥投加比例下河道底泥磷释放作用的研究,发现底泥中铁铝磷与钙磷的比值(Fe/Al-P∶Ca-P)、铁磷比(Fe∶TP)及有机质含量(OM)是赤泥能否应用于河道底泥磷释放控制中的决定性因素。实验结果表明,只有当河道底泥中Fe/Al-P∶Ca-P小于0.88,Fe∶TP小于16.1,且有机质含量低于1.87%时,投加适量赤泥才能起到抑制河道底泥内源磷释放的作用;反之,赤泥的投加则有可能促进底泥内源磷的释放。在实际工程应用中,推荐赤泥与底泥的接触时间不低于7d,从而使赤泥的效能发挥到最佳状态。  相似文献   

20.
提出了一种利用餐厨废油为热交换介质,在常压下对城市污水厂污泥进行油炸干化制成固体燃料,以实现城镇两大废弃物一污泥和餐厨废油综合处置的方法。以大豆油模拟餐厨废油,研究了污泥油炸干燥特性及过程影响参数。实验结果表明,污泥经油炸干化后,干基含水率从初始的4.56kg/kg降低至0.05kg/kg,干基含油率升为0.37~0.47kg/kg,干污泥热值达到21.551~24.082MJ/kg,是一种高热值固体燃料。油温对污泥油炸干化过程影响显著,当油温从120℃升至180℃时,污泥干燥时间从28min缩短至4min。实验条件下,1t餐厨废油可处理约8.3t湿污泥。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号