首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 750 毫秒
1.
Ozone disintegration of excess biomass and application to nitrogen removal.   总被引:1,自引:0,他引:1  
A pilot-scale facility integrated with an ozonation unit was built to investigate the feasibility of using ozone-disintegration byproducts of wasted biomass as a carbon source for denitrification. Ozonation of biomass resulted in mass reduction by mineralization as well as by ozone-disintegrated biosolids recycling. Approximately 50% of wasted solids were recovered as available organic matter (ozonolysate), which included nonsettleable microparticles and soluble fractions. Microparticles were observed in abundance at relatively low levels of ozone doses, while soluble fractions became dominant at higher levels of ozone doses in ozone-disintegrated organics. Batch denitrification experiments showed that the ozonolysate could be used as a carbon source with a maximum denitrification rate of 3.66 mg nitrogen (N)/g volatile suspended solids (VSS) x h. Ozonolysate was also proven to enhance total nitrogen removal efficiency in the pilot-scale treatment facility. An optimal chemical oxygen demand (COD)-to-nitrogen ratio for complete denitrification was estimated as 5.13 g COD/g N. The nitrogen-removal performance of the modified intermittently decanted extended aeration process dependent on an external carbon supply could be described as a function of solids retention time.  相似文献   

2.
稳态条件下,采用厌氧折流板反应器(anaerobic baffled reactor,ABR)处理山梨酸废水并进行基质降解动力学研究.实验表明,在污泥负荷为0.54~1.63 kg COD/(kg VSS·d)的范围内,COD去除率随着负荷的增加从85%降到55%.各隔室出水COD沿程递减,前3个隔室承担了去除COD的重要作用,但随着污泥负荷的增加,后部承担的COD去除率比例增大.基于各串联隔室完全混合的假定,推导ABR中山梨酸废水的基质降解动力学方程,并通过实验确定相关动力学参数及相应的动力学方程.实测值与预测值基本吻合.  相似文献   

3.
The present work is aimed at increasing the overall efficiency of the treatment process of distillery spent wash using a combination of different treatment techniques. Initially the effluent samples were subjected to Thermal Pretreatment (TPT-DW) and anaerobic treatment (ANA-DW). Advanced oxidation techniques, viz., Ultrasound (US) and Ozone were then used for further COD reduction followed by the conventional aerobic oxidation using mixed microbial consortium. Pretreatment of TPT-DW with US and Ozone (as stand alone techniques) enhanced the subsequent aerobic oxidation rate. For US treated sample, a maximum of 13% COD reduction was attained at the end of 48 h of aerobic oxidation, while for the ozone treated effluent a maximum of 45.6% COD reduction was obtained as compared to mere 1.8% COD reduction for the control (TPT-DW directly subjected to aerobic oxidation) indicating a 25 times increase in the rate of aerobic biodegradation of ozonated sample. Anaerobically treated effluent sample (ANA-DW) could be successfully treated aerobically. In this case, however, the use of advanced oxidation techniques did not result in any synergistic effects. The rate of the aerobic oxidation was slightly higher for the control (ANA-DW directly subjected to aerobic oxidation) as compared to the sample pretreated using ultrasound or ozonation. TOC analysis revealed that between the two pretreatments studied, ozone was found to be superior over US as it led to both COD as well as TOC reduction during the aerobic oxidation step for ANA-DW effluent stream.  相似文献   

4.
填料-生物转盘处理有机模拟污水   总被引:2,自引:0,他引:2  
针对传统生物转盘启动慢、挂膜性能差、水力停留时间长等缺点,采用英国某生物技术公司研制的新型填料复合式生物转盘处理有机模拟污水,考察水力停留时间、转盘转速、有机负荷等因素对工艺运行效果的影响。结果表明,新型生物转盘启动快,微生物相变化明显,微生物量大,挂膜效率高;抗负荷冲击能力强,有机负荷大幅度变化对其影响较小;二级转笼处有机负荷相对较低,溶解氧高,微生物的种类、数量均比一级转笼多;该转盘处理有机模拟污水的最优水力停留时间为1.5 h,最佳转速为12.4 r/min,较传统生物转盘污水处理量大,且污水COD去除率高达97%,大大降低运行能耗,出水水质达到城镇污水处理厂污染物排放标准(GB18918-2002)中的一级A标准。  相似文献   

5.
To use the results of kinetic tests to predict effluent concentrations of specific contaminants in activated sludge systems, the fraction of the biomass that has an ability to degrade the test compound (i.e., competent biomass) must be estimated. A calibration procedure was developed to assess the competent biomass concentration because the chemical oxygen demand (COD) fraction tended to underestimate the degrading fraction for three of the four test compounds. Acetone, for instance, had a measured influent COD fraction of 0.08%, and the actual competent fraction was estimated to be 2.3%, based on the model calibration. Once the competent biomass fraction in the mixed liquor was determined, the extant kinetic parameters were subsequently used to predict activated sludge system performance. Predicted effluent concentrations were within 2, 5, and 16% of the average measured concentrations for acetone, linear alkylbenzene sulfonate, and furfural, respectively. Day-to-day predictions for these compounds were less accurate, possibly because of the non-steady-state nature of the activated sludge systems studied. The difference between the fraction of the influent COD contributed by the target compounds and the competent biomass fraction in the mixed liquor was found to be more significant when the target compound contributed less than 1% of the influent organic matter. The chemical structure of the target compound and chemical composition of the influent likely had an effect on the resulting competent biomass concentration. The total maximum growth rate, microX, was observed to be independent of the influent concentration of acetone and furfural, thus suggesting that the competent biomass concentration for these compounds was not affected by the changes in their influent concentrations. Consequently, a majority of competent biomass growth resulted from the degradation of other substrates, resulting in a competent biomass concentration significantly higher than predicted based on the influent COD fraction contributed by the test compound.  相似文献   

6.
Distillery spent-wash has very high organic content (75,000 to 125,000 mg/L chemical-oxygen demand [COD]), color, and contains difficult-to-biodegrade organic compounds. For example, anaerobic treatment of the distillery spent-wash used in this study resulted in 60% COD reduction and low color removal. Subsequent aerobic treatment of the anaerobic effluent resulted in enhancement of COD removal to 66%. In this paper, the effect of ozonation on various properties of the anaerobically treated distillery effluent, including the effect on its subsequent aerobic biodegradation, was investigated. Ozonation of the anaerobically treated distillery effluent at various ozone doses resulted in the reduction of total-organic carbon (TOC), COD, COD/TOC ratio, absorbance, color, and increase in the biochemical-oxygen demand (BOD)/COD ratio of the effluent. Further, ozonation of the anaerobically treated distillery effluent at an ozone dose of 2.08 mg/mg initial TOC and subsequent aerobic biodegradation resulted in 87.4% COD removal, as compared to 66% removal when ozonation was not used.  相似文献   

7.

Heavy metals in higher concentrations are often encountered in domestic sewage of developing and under-developed countries. High metallic concentrations can stress reactor sludge biomass morphology impeding its performance in organics reduction. However, the extent of damage and ability of sludge biomass to recover from the metallic stress is not fully understood. Also, there is no protocol to identify and prevent the sludge biomass from metallic stress in fully functional sewage treatment plants (STPs). This study investigates performance, metabolic activity, morphology, and settling characteristics of the sludge biomass under different Co(II) stress conditions. The extent of recovery in biomass, when the supply of Co(II) metal ion was discontinued in the inlet stream, was explored. The study also proposed a protocol based on simple settling characteristics of sludge biomass to get an early indication of metal infiltration to prevent potential damage to the biomass morphology. Four sequencing batch reactors (SBRs) with Co(II) ion concentrations of 0 (designated as RCo0), 5 (RCo5), 25 (RCo25), and 75 mg/L (RCo75) in the feed were operated with a cycle time of 12 h. Reactors were operated for 35 days with Co(II) in the feed (termed as stressed phase operation) followed by 24 days of operation without Co(II) in the feed (termed as recovery phase operation). Results show that COD removal in reactor RCo75 reduced to 48% on the 10th day of stressed phase operation, showing a lag in COD removal due to metallic stress. The activity of biomass in reactors RCo5, RCo25, and RCo75 was reduced by 39%, 45%, and 49%, respectively, in the stressed phase compared to the biomass in control reactor. Recovery in COD removal efficiency and specific biomass activity were observed in all the reactors after the removal of metallic stress. The settleability of sludge biomass in reactors RCo25 and RCo75 was significantly affected. Transformation in the shape of flocs in reactor RCo25 and RCo75 biomasses revealed the prolonged effect of metallic stress, which was observed to be irreversible even during the recovery phase operation.

  相似文献   

8.
This study is aimed at exploring strategies for mineralization of refractory compounds in distillery effluent by anaerobic biodegradation/ozonation/aerobic biodegradation. Treatment of distillery spent-wash used in this research by anaerobic-aerobic biodegradation resulted in overall COD removal of 70.8%. Ozonation of the anaerobically treated distillery spent-wash was carried out as-is (phase I experiments) and after pH reduction and removal of inorganic carbon (phase II experiments). Introduction of the ozonation step resulted in an increase in overall chemical oxygen demand (COD) removal, with the highest COD removals of greater than 95% obtained when an ozone dose of approximately 5.3 mg ozone absorbed/mg initial total organic carbon was used. The COD removal during phase II experiments was slightly superior compared with phase I experiments at similar ozone doses. Moreover, efficiency of ozone absorption from the gas phase into distillery spent-wash aliquots was considerably enhanced during phase II experiments.  相似文献   

9.
Lee KM  Lim PE 《Chemosphere》2005,58(4):407-416
The role of bioregeneration process in renewing the adsorbent surface for further adsorption of organics during simultaneous adsorption and biodegradation processes has been well recognized. The extent of bioregeneration of powdered activated carbon (PAC) as an adsorbent loaded with phenol, p-methylphenol, p-ethylphenol and p-isopropylphenol, respectively, in the simultaneous adsorption and biodegradation processes were quantitatively determined using oxygen uptake as a measure of substrate consumption. Bioregeneration phenomenon was also evaluated in the simultaneous adsorption and biodegradation processes under sequencing batch reactor (SBR) operation to treat synthetic wastewater containing 1200 mg l(-1) phenol and p-methylphenol, respectively. The SBR systems were operated with FILL, REACT, SETTLE, DRAW and IDLE periods in the ratio of 4:6:1:0.75:0.25 for a cycle time of 12 h. The results show that the percentage of desorption from loaded PAC decreased in the order phenol>p-methylphenol>p-ethylphenol>p-isopropylphenol. For the treatment of phenol and p-methylphenol in the SBR reactors, respectively, the simultaneous adsorption and biodegradation processes were able to produce a consistent effluent quality of COD < or = 100 mg l(-1) when the applied PAC dosage was 0.115 and 0.143 g PAC per cycle, respectively. When no further PAC was added, the treatment performance deteriorated to that of the case without PAC addition after 68 and 48 cycles of SBR operation, respectively, for phenol and p-methylphenol. This observation is consistent with the greater extent of bioregeneration for phenol-loaded PAC as compared to p-methylphenol-loaded PAC.  相似文献   

10.
This study examines the feasibility of coupling a Catalytic Wet Air Oxidation (CWAO), with activated carbon (AC) as catalyst, and an aerobic biological treatment to treat a high-strength o-cresol wastewater. Two goals are pursued: (a) To determine the effect of the main AC/CWAO intermediates on the activated sludge of a municipal WasteWater Treatment Plant (WWTP) and (b) To demonstrate the feasibility of coupling the AC/CWAO effluent as a part of the influent of a municipal WWTP. In a previous study, a high-strength o-cresol wastewater was treated by AC/CWAO aiming to establish the distribution of intermediates and the biodegradability enhancement. In this work, the biodegradability, toxicity and inhibition of the most relevant intermediates detected in the AC/CWAO effluent were determined by respirometry. Also, the results of a pilot scale municipal WWTP study for an integrated AC/CWAO-aerobic biological treatment of this effluent are presented. The biodegradation parameters (i.e. maximum oxygen uptake rate and oxygen consumption) of main AC/CWAO intermediates allowed the classification of the intermediates into readily biodegradable, inert or toxic/inhibitory compounds. This detailed study, allowed to understand the biodegradability enhancement exhibited by an AC/CWAO effluent and to achieve a successful strategy for coupling the AC/CWAO step with an aerobic biological treatment for a high-strength o-cresol wastewater. Using 30%, as COD, of AC/CWAO effluent in the inlet to the pilot scale WWTP, the integrated AC/CWAO-biological treatment achieved a 98% of total COD removal and, particularly, a 91% of AC/CWAO effluent COD removal without any undesirable effect on the biomass.  相似文献   

11.
Biomass from a prototype reactor was used to investigate the kinetics of chemoheterotrophic reduction of solutions of ferric ethylenediaminetetraacetic acid (EDTA) and solutions containing the nitrosyl adduct of ferrous EDTA using ethanol as the primary electron donor and carbon source. A series of batch experiments were conducted using biomass extracted from the scrubber solution treatment and regeneration stage of a prototype iron EDTA-based unit process for the absorption of nitric oxide with subsequent biological treatment. Using a linear-sweep voltammetric method for analysis of the ferric EDTA concentration, iron-reducing bacteria were found to behave according to the Monod kinetic model, at initial concentrations up to 2.16 g chemical oxygen demand (COD) as ethanol per liter, with a half-velocity constant of 0.532 g COD as ethanol/L and a maximum specific utilization rate of 0.127 mol/L of ferric ethylenediamine-tetraacetic acid [Fe(III)EDTA]*(g volatile suspended solids [VSS]/L)d(-1). Based on batch analyses, biomass yield and endogenous decay values of iron-reducing bacteria were estimated to be 0.055 g VSS/g COD and 0.017 L/d, respectively. An average of 1.64 times the theoretical (stoichiometric) demand of ethanol was used to complete reduction reactions. Kinetics of the reduction of the nitrosyl adduct of ferrous EDTA are summarized by the following kinetic constants: half-velocity constant (Ks) of 0.39 g COD/L, maximum specific utilization rate (k) of 0.2 mol/L [NO x Fe(II)EDTA(2-)](g VSS/L)d(-1), and inhibition constant (K(I)) of 0.33 g COD/L, as applied to the modified Monod kinetic expression described herein. Based on batch analyses, the biomass yield of nitrosyl-adduct-reducing bacteria was estimated to be 0.259 g VSS/g COD, endogenous decay was experimentally determined to be 0.0569 L/d, and an average of 1.26 times the stoichiometric demand of ethanol was used to complete reduction reactions.  相似文献   

12.
废水COD 4种物化表征方法的比较与评估   总被引:1,自引:1,他引:0  
为了确定废水COD组分表征的物化分析方法,对0.1μm滤膜过滤、0.45μm滤膜过滤、絮凝和絮凝+0.45μm滤膜过滤4种方法进行了实验比较和评估。结果表明:某些材料的滤膜会因"COD溶出"而影响表征结果;4种方法分离废水的重现性都很好,相互没有明显区别;物化分离对废水快速可生物降解COD(SS)没有影响,但4种方法得到的处理液中可生物降解COD仍含降解速率明显不同的组分,其中SS仅占35%~45%。因此,物化方法不能合理表征SS;絮凝+0.45μm滤膜过滤速度快、干扰少、分离机理与活性污泥系统类似,更适用于废水溶解性惰性COD组分(SI)表征。  相似文献   

13.
A study of the anaerobic treatment of wastewaters derived from red (RWWW) and tropical fruit wine (TFWWW) production was carried out in four laboratory-scale fluidized bed reactors with natural zeolite as bacterial support. These reactors operated at mesophilic temperature (35 degrees C). Reactors R1 and R2 contained Chilean natural zeolite, while reactors R3 and R4 used Cuban natural zeolite as microorganism support. In addition, reactors R1 and R3 processed RWWW, while reactors R2 and R4 used TFWWW as substrate. The biomass concentration attached to zeolites in the four reactors studied was found to be in the range of 44-46 g volatile solids (VS)/L after 90 days of operation time. Both types of zeolites can be used indistinctly in the fluidized bed reactors achieving more than 80%-86% chemical oxygen demand (COD) removals for organic loading rates (OLR) of up to at least 20 g COD/L d. pH values remained within the optimal range for anaerobic microorganisms for OLR values of up to 20 and 22 g COD/L d for RWWW and TFWWW, respectively. Toxicity and inhibition levels were observed at an OLR of 20 g COD/L d in reactors R1 and R3 while processing RWWW, whereas the aforementioned inhibitory phenomena were not observed at an OLR of 24 g COD/L d in R2 and R4, treating TFWWW as a consequence of the lower phenolic compound content present in this substrate. The volatile fatty acid (VFA) levels were always lower in reactors processing TFWWW (R2 and R4) and these values (< 400 mg/L, as acetic acid) were lower than the suggested limits for digester failure. The specific methanogenic activity (SMA) was twice as high in reactors R2 and R4 than in R1 and R3 after 120 days of operation when all reactors operated at an OLR of 20 g COD/L d.  相似文献   

14.
Goals, Scope and Background It has been observed that hydrocarbon treated wastewaters still contain high COD and a number of intermediates. This suggests that the required catabolic gene pool for further degradation might be absent in the system or, that its titer value is not significant enough. By providing the desired catabolic potential, the overall efficiency of the treatment system can be improved. This study aims to demonstrate this concept by bioaugmentation of a lab-scale reactor treating refinery wastewater with a consortium having the capacity to complement the alkB genotype to the available microbial population. Methods Two reactors were set up using activated biomass collected from a refinery treatment plant and operated at a continuous mode for a period of 8 weeks. The feed to both reactors was kept constant. Crude oil was spiked regularly. One reactor was bioaugmented with a consortium previously described for crude oil spill remediation. The efficiency of the bioaugmented reactor was demonstrated by reduced COD. The changes in the microbial population over a period of time were analyzed by RAPD. Catabolic activity of the biomass in both reactors was monitored by PCR. The presence of the catabolic loci was confirmed by Southern Hybridization. Results and Discussion 52.2% removal of COD was observed in the bioaugmented reactor while only 15.1% reduction of COD was observed in the reactor without bioaugmentation. The change in microbial population can be seen from the 4th week, which also corresponds to improved catabolic activity. The presence of the bedA locus was seen in all samples, which indicates the presence of aromatic degraders, but the appearance of the alkB locus, from the 6th week onwards, which was observed only in the samples from the bioaugmented reactor. The results suggest that the gene pool of the bioaugmented reactor has catabolic loci that can degrade accumulated intermediates, thus improving the efficiency of the system. Conclusions In this study, improvement of efficiency of bioremediation was demonstrated by addition of catabolic loci that are responsible for degradation. Bioaugmentation was carried out in biomass that was collected from an ETP (effluent treatment plant) treating hydrocarbon containing wastewater to study the strategies for improvement of the treatment system. Biostimulation, only marginally improved the efficiency, when compared to bioaugmentation. The improved efficiency was demonstrated by COD removal. The presence of the alkB locus suggests the importance of a catabolic gene pool that acts on accumulated intermediates. It is well documented that straight chain aliphatics and intermediates of aromatic compounds after ring cleavage, accumulate in refinery wastewater systems, thereby hindering further degradation of the wastewater. Supplementation of a catabolic gene pool that treats the lower pathway compounds and alkanes will improve the overall efficiency. In this study, results suggest that the alkB locus can also be used to monitor the degradative mode of the activated biomass. Recommendations and Perspective . Pollution from petroleum and petroleum products around the globe are known to have grave consequences on the environment. Bioremediation, using activated sludge, is one option for the treatment of such wastes. Effluent treatment plants are usually unable to completely degrade the wastewater being treated in the biological unit (the aerator chambers). The efficiency of degradation can be improved by biostimulation and bioaugmentation. This study demonstrates the improved efficiency of a treatment system for wastewater containing hydrocarbons by bioaugmentation of a consortium that supports degradation. Further experiments on a pilot scale are recommended to assess the use of bioaugmentation on a large scale. The use of molecular tools, like DNA probes for alkB, to monitor the system also needs to be explored.  相似文献   

15.
A new bioassay proposed in the patent P201300029 was applied to a pre-treated wastewater containing a mixture of commercial pesticides to simulate a recalcitrant industrial wastewater in order to determine its biodegradability. The test uses a mixture of standardized inoculum of the lyophilized bacteria Pseudomonas putida with the proper proportion of salts and minerals. The results highlight that biodegradation efficiency can be calculated using a gross parameter (chemical oxygen demand (COD)) which facilitates the biodegradability determination for routine water biodegradability analysis. The same trend was observed throughout the assay with the dehydrated and fresh inoculums, and only a difference of 5 % in biodegradation efficiency (E f) was observed. The obtained results showed that the P. putida biodegradability assay can be used as a commercial test with a lyophilized inoculum in order to monitor the ready biodegradability of an organic pollutant or a WWTP influent. Moreover, a combination of the BOD5/COD ratio and the P. putida biodegradability test is an attractive alternative in order to evaluate the biodegradability enhancement in water pre-treated with advanced oxidation processes (AOPs).  相似文献   

16.
设计并利用在差压仪中密闭投加基质的实验方法,根据ASM模型中自养菌和硝化过程耗氧速率的关系,对比研究了ECOSUNIDE工艺和其他4个污水处理厂曝气池混合液中自养菌的浓度。研究表明,在不考虑自养菌增长和衰减情况下,ECOSUNIDE工艺混合液自养菌生物浓度为48.15 mg COD/L,该结果显著高于其他受试污水处理厂的混合液自养菌生物浓度(17.2~37.5 mg COD/L),表明ECOSUNIDE工艺在提高活性污泥中自养菌生物浓度上有较强的优势。设计的实验方法可以简便、有效地测定用于ASM模型中的自养菌浓度。  相似文献   

17.
The biodegradation of nitrobenzene (NB) and 2,4-dinitrophenol (DNP) in NB plant wastewater has been studied using acclimated activated sludge in a batch bioreactor. The gas chromatographic (GC) monitoring shows simultaneous utilization of these two substrates, and both NB and DNP were ultimately biodegraded. The primary and ultimate biodegradation rates using GC and COD methods, respectively, are compared and reported.  相似文献   

18.
A study of the anaerobic treatment of wastewaters derived from red (RWWW) and tropical fruit wine (TFWWW) production was carried out in four laboratory-scale fluidized bed reactors with natural zeolite as bacterial support. These reactors operated at mesophilic temperature (35°C). Reactors R1 and R2 contained Chilean natural zeolite, while reactors R3 and R4 used Cuban natural zeolite as microorganism support. In addition, reactors R1 and R3 processed RWWW, while reactors R2 and R4 used TFWWW as substrate. The biomass concentration attached to zeolites in the four reactors studied was found to be in the range of 44–46 g volatile solids (VS)/L after 90 days of operation time. Both types of zeolites can be used indistinctly in the fluidized bed reactors achieving more than 80%–86% chemical oxygen demand (COD) removals for organic loading rates (OLR) of up to at least 20 g COD/L d. pH values remained within the optimal range for anaerobic microorganisms for OLR values of up to 20 and 22 g COD/L d for RWWW and TFWWW, respectively. Toxicity and inhibition levels were observed at an OLR of 20 g COD/L d in reactors R1 and R3 while processing RWWW, whereas the aforementioned inhibitory phenomena were not observed at an OLR of 24 g COD/L d in R2 and R4, treating TFWWW as a consequence of the lower phenolic compound content present in this substrate. The volatile fatty acid (VFA) levels were always lower in reactors processing TFWWW (R2 and R4) and these values (< 400 mg/L, as acetic acid) were lower than the suggested limits for digester failure. The specific methanogenic activity (SMA) was twice as high in reactors R2 and R4 than in R1 and R3 after 120 days of operation when all reactors operated at an OLR of 20 g COD/L d.  相似文献   

19.
BACKGROUND: Dye wastewater is one of the main pollution sources of water bodies in China. Conventional biological processes are relatively ineffective for color removal, the development of alternative treatment methods will become important. Our subjective was that of introducing a new biotreatment technology which combined a facultative biofilm reactor (FBR) with an aerobic reactor (AR) to treat a dye wastewater. The efficiencies of color and chemical oxygen demand (COD) removal and the mechanism of dye degradation were investigated. METHODS: The anthraquinone acid dye (acid blue BRLL) concentration, organic loading rate (OLR) and hydraulic retention time (HRT) were varied in the experiments to evaluate the treatment efficiency and process stability. The biodegradation products were detected by infrared (IR) and high performance liquid chromatography and mass spectrometry (HPLC-MS). RESULTS AND DISCUSSION: The results demonstrated that the facultative biofilm process was more effective for decolorization than the anaerobic stage of an anaerobic-aerobic process. Most color removal occurred in the facultative reaction (maximum to 88.5%) and the BOD (biochemical oxygen demand): COD of the FBR effluent increased by 82.2%, thus improving the biodegradability of dyes for further aerobic treatment. The dye concentration, OLR and HRT will be the factors affecting decolorization. Color removal efficiency falls as the influent dye concentration increases, but rises with increased HRT. The infrared and HPLC-MS analyses of the effluents of FBR and AR reveal that the dye parent compound was degraded in each reactor during the process. CONCLUSION: The Facultative-aerobic (F-A) system can effectively remove both color and COD from the dye wastewater. The FBR played an essential role in the process. The average overall color and COD in the system were removed by more than 93.9% and 97.1%, respectively, at an OLR of 1.1 kg COD m(-3) d(-1) and at the HRT of 18-20 hours in the FBR and 4-5 hours in the AR. The color removal mechanism in each reactor was not only a sort of biosorption on the floc materials, but even more an effect of biodegradation, especially in the facultative process. Recommendation and Outlook. In applying the F-A system to treat a dye wastewater, the control of facultative processes and the set up of appropriate operation conditions appear to be critical factors. Also, it is suggested a moderate COD loading rate and about a 24-hour HRT will favor the F-A system.  相似文献   

20.
The objective of this investigation was to compare two biological systems using attached-growth biomass, for treatment of leachates generated in a typical municipal solid waste sanitary landfill. A moving-bed biofilm process, which is a relatively new type of biological treatment system, has been examined. It is based on the use of small, free-floating polymeric (polyurethane) elements, while biomass is being grown and attached as biofilm on the surface of these porous carriers. A granular activated carbon (GAC) moving-bed biofilm process was also tested. This method combines both physico-chemical and biological removal mechanisms for the removal of pollutants. The presence of GAC offers a suitable porous media, which is able to adsorb both organic matter and ammonia, as well as to provide an appropriate surface onto which biomass can be attached and grown. A laboratory-scale sequencing batch reactor (SBR) was used for the examination of both carriers. The effects of different operation strategies on the efficiency of these biological treatment processes were studied in order to optimize their performance, especially for the removal of nitrogen compounds and of biodegradable organic matter. It has been found that these processes were able to remove nitrogen content almost completely and simultaneously, the removal of organic matter (expressed as BOD5 and COD), color and turbidity were sufficiently achieved.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号