首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
The application of advanced oxidation process (AOP) in the treatment of wastewater contaminated with oil was investigated in this study. The AOP investigated is the homogeneous photo-Fenton (UV/H2O2/Fe+2) process. The reaction is influenced by the input concentration of hydrogen peroxide H2O2, amount of the iron catalyst Fe+2, pH, temperature, irradiation time, and concentration of oil in the wastewater. The removal efficiency for the used system at the optimal operational parameters (H2O2?=?400 mg/L, Fe+2?=?40 mg/L, pH?=?3, irradiation time?=?150 min, and temperature?=?30 °C) for 1,000 mg/L oil load was found to be 72 %. The study examined the implementation of artificial neural network (ANN) for the prediction and simulation of oil degradation in aqueous solution by photo-Fenton process. The multilayered feed-forward networks were trained by using a backpropagation algorithm; a three-layer network with 22 neurons in the hidden layer gave optimal results. The results show that the ANN model can predict the experimental results with high correlation coefficient (R 2?=?0.9949). The sensitivity analysis showed that all studied variables (H2O2, Fe+2, pH, irradiation time, temperature, and oil concentration) have strong effect on the oil degradation. The pH was found to be the most influential parameter with relative importance of 20.6 %.  相似文献   

2.
The Fenton-like degradation of nalidixic acid was studied in this work. The effects of Fe3+ concentration and initial H2O2 concentration were investigated. Increasing the initial H2O2 concentration enhances the degradation and mineralization efficiency for nalidixic acid, while Fe3+ shows an optimal concentration of 0.25 mM. A complete removal of nalidixic acid and a TOC removal of 28 % were achieved in 60 min under a reaction condition of [Fe3+]?=?0.25 mM, [H2O2]?=?10 mM, T?=?35 °C, and pH?=?3. LC–MS analysis technique was used to analyze the possible degradation intermediates. The degradation pathways of nalidixic acid were proposed according to the identified intermediates and the electron density distribution of nalidixic acid. The Fenton-like degradation reaction of nalidixic acid mainly begins with the electrophilic attack of hydroxyl radical towards the C3 position which results in the ring-opening reaction; meanwhile, hydroxyl radical attacking to the branched alkyl groups of nalidixic acid leads to the oxidation at the branched alkyl groups.  相似文献   

3.
The aim of this study was to assess the degradation and mineralization of hydroquinone (HQ) by the Fenton’s process in a bubble column reactor (BCR). The effect of the main operating variables, namely, air flow rate, effluent volume, hydrogen peroxide (H2O2) concentration, catalyst (Fe2+) dose, initial pH, and temperature, were assessed. For all air flow rates tested, no concentration gradients along the column were noticed, evidencing that a good mixing was reached in the BCR. For the best conditions tested ([H2O2] = 500 mg/L, [Fe2+] = 45 mg/L, T = 24 °C, Q air = 2.5 mL/min, pH = 3.0, and V = 5 L), complete HQ degradation was reached, with ~ 39% of total organic carbon (TOC) removal, and an efficiency of the oxidant use—η H2O2—of 0.39 (ratio between TOC removed per H2O2 consumed normalized by the theoretical stoichiometric value); moreover, a non-toxic effluent was generated. Under these conditions, the intermediates and final oxidation compounds identified and quantified were a few carboxylic acids, namely, maleic, pyruvic, and oxalic. As a strategy to improve the TOC removal, a gradual dosage of the optimal H2O2 concentration was implemented, being obtained ~ 55% of mineralization (with complete HQ degradation). Finally, the matrix effect was evaluated, for which a real wastewater was spiked with 100 mg/L of HQ; no reduction in terms of HQ degradation and mineralization was observed compared to the solution in distilled water.  相似文献   

4.
In this study, photocatalytic (photo-Fenton and H2O2/UV) and dark Fenton processes were used to remove ethylenethiourea (ETU) from water. The experiments were conducted in a photo-reactor with an 80 W mercury vapor lamp. The mineralization of ETU was determined by total organic carbon analysis, and ETU degradation was qualitatively monitored by the reduction of UV absorbance at 232 nm. A higher mineralization efficiency was obtained by using the photo-peroxidation process (UV/H2O2). Approximately 77% of ETU was mineralized within 120 min of the reaction using [H2O2]0 = 400 mg L?1. The photo-Fenton process mineralized 70% of the ETU with [H2O2]0 = 800 mg L?1 and [Fe2+] = 400 mg L?1, and there is evidence that hydrogen peroxide was the limiting reagent in the reaction because it was rapidly consumed. Moreover, increasing the concentration of H2O2 from 800 mg L?1 to 1200 mg L?1 did not enhance the degradation of ETU. Kinetics studies revealed that the pseudo-second-order model best fit the experimental conditions. The k values for the UV/H2O2 and photo-Fenton processes were determined to be 6.2 × 10?4 mg L?1 min?1 and 7.7 × 10?4 mg L?1 min?1, respectively. The mineralization of ETU in the absence of hydrogen peroxide has led to the conclusion that ETU transformation products are susceptible to photolysis by UV light. These are promising results for further research. The processes that were investigated can be used to remove pesticide metabolites from drinking water sources and wastewater in developing countries.  相似文献   

5.
The present research deals with the development of a new heterogeneous photocatalysis and Fenton hybrid system for the removal of color from textile dyeing wastewater as Rhodamine B (RhB) solutions by using Fe2+/H2O2/Nb2O5 as a photocatalytic system. The application of this photocatalytic system for the decolorization of dye contaminants is not reported in the literature yet. Different parameters like dye concentration, Nb2O5/Fe2+ catalyst amount, pH, and H2O2 concentration have been studied. The optimum conditions for the decolorization of the dye were initial concentration of 10 mg L?1 of dye, pH 4, and Nb2O5/Fe2+ catalyst concentration of 0.5 g L?1/50 mg L?1. The optimum value of H2O2 concentration for the conditions used in this study was 700 mg L?1. Moreover, the efficiency of the Nb2O5/photo-Fenton hybrid process in comparison to photo-Fenton alone and a dark Fenton process as a control experiment to decolorize the RhB solution has been investigated. The combination of photo-Fenton and Nb2O5 catalysts has been proved to be the most effective for the treatment of such type of wastewaters. The results revealed that the RhB dye was decolorized in a higher percent (78 %) by the Nb2O5/photo-Fenton hybrid process (Fe2+/H2O2/Nb2O5/UV) than by the photo-Fenton process alone (37 %) and dark Fenton process (14 %) after 120 min of treatment. Moreover, the Nb2O5 catalyst as a heterogeneous part of the photocatalytic system was demonstrated to have good stability and reusability.  相似文献   

6.

A theoretical and experimental study of bisphenol A (BPA) degradation by the UV/H2O2 process in water is presented. The effects of the H2O2 concentration and the specific rate of photon emission (EP,0) on BPA degradation were investigated. A kinetic model derived from a reaction sequence was employed to predict BPA and hydrogen peroxide concentrations over time using an annular photochemical reactor in batch recirculation mode. The local volumetric rate of photon absorption (LVRPA) inside the photoreactor was computed using a Line Source with Parallel Plane emission model (LSPP). From the proposed kinetic model and the experimental data, the second order rate constants of the reactions between hydroxyl radicals and the main reacting species (H2O2 and BPA) were estimated applying a nonlinear regression method. A good agreement between the kinetic model and experimental data, for a wide range of operating conditions, was obtained. For BPA, H2O2, and TOC concentrations, the calculated root means square errors (RMSE) were 2.3?×?10??2, 9.8?×?10??1, and 9.0?×?10??2 mmol L??1, respectively. The simplified kinetic model presented in this work can be directly applied to scaling-up and reactor design, since the estimated kinetic constants are independent of the reactor size, shape, and configuration. Further experiments were made by employing low BPA initial concentration (100 μg L??1) in water and real wastewater. A lower degradation rate of BPA was observed in the real wastewater, although the UV/H2O2 process has also been able to completely degrade the target pollutant in less than 1 h.

  相似文献   

7.
Photochemical degradation of fluoroquinolone ciprofloxacin (CIP) in water by UV and UV/H2O2 were investigated. The degradation rate of CIP was affected by pH, H2O2 dosage, as well as the presence of other inorganic components. The optimized pH value and H2O2 concentration were 7.0 and 5 mM. Carbonate and nitrate both impeded CIP degradation. According to liquid chromatography–tandem mass spectrometry analysis, four and 16 products were identified in UV and UV/H2O2 system, respectively. Proposed degradation pathways suggest that reactions including the piperazinyl substituent, quinolone moiety, and cyclopropyl group lead to the photochemical degradation of CIP. Toxicity of products assessed by Vibrio qinghaiensis demonstrated that UV/H2O2 process was more capable on controlling the toxicity of intermediates in CIP degradation than UV process.  相似文献   

8.
A new method for the degradation of bisphenol A (BPA) in aqueous solution was developed. The oxidative degradation characteristics of BPA in a heterogeneous Fenton reaction catalyzed by Fe3O4/graphite oxide (GO) were studied. Transmission electron microscopic images showed that the Fe3O4 nanoparticles were evenly distributed and were ~6 nm in diameter. Experimental results suggested that BPA conversion was affected by several factors, such as the loading amount of Fe3O4/GO, pH, and initial H2O2 concentration. In the system with 1.0 g L?1 of Fe3O4/GO and 20 mmol L?1 of H2O2, almost 90 % of BPA (20 mg L?1) was degraded within 6 h at pH 6.0. Based on the degradation products identified by GC–MS, the degradation pathways of BPA were proposed. In addition, the reused catalyst Fe3O4/GO still retained its catalytic activity after three cycles, indicating that Fe3O4/GO had good stability and reusability. These results demonstrated that the heterogeneous Fenton reaction catalyzed by Fe3O4/GO is a promising advanced oxidation technology for the treatment of wastewater containing BPA.  相似文献   

9.
This investigation was undertaken to determine the atrazine degradation by fungal enzyme extracts (FEEs) in a clay-loam soil microcosm contaminated at field application rate (5 μg g?1) and to study the influence of different soil microcosm conditions, including the effect of soil sterilization, water holding capacity, soil pH and type of FEEs used in atrazine degradation through a 24 factorial experimental design. The Trametes maximaPaecilomyces carneus co-culture extract contained more laccase activity and hydrogen peroxide (H2O2) content (laccase = 18956.0 U mg protein?1, H2O2 = 6.2 mg L?1) than the T. maxima monoculture extract (laccase = 12866.7 U mg protein?1, H2O2 = 4.0 mg L?1). Both extracts were able to degrade atrazine at 100%; however, the T. maxima monoculture extract (0.32 h) achieved a lower half-degradation time than its co-culture with P. carneus (1.2 h). The FEE type (p = 0.03) and soil pH (p = 0.01) significantly affected atrazine degradation. The best degradation rate was achieved by the T. maxima monoculture extract in an acid soil (pH = 4.86). This study demonstrated that both the monoculture extracts of the native strain T. maxima and its co-culture with P. carneus can efficiently and quickly degrade atrazine in clay-loam soils.  相似文献   

10.
This study presents the degradation of phenol by the photoelectro-Fenton method using nano zero-valent iron (nZVI) immobilized in polyvinyl alcohol–alginate beads. The effect of nZVI loading, H2O2 concentration, pH, and initial phenol concentration on phenol degradation and chemical oxygen demand reduction was studied. The scanning electron microscope images of the nZVI beads were used to analyze their morphology, and their diameters were in the range of 500–600 μm. The concentration of nZVI in the beads was varied from 0.1 to 0.6 g/L. Fe2+ leakage of 1 and 3 % was observed with 0.5 and 0.6 g/L of nZVI, respectively, and the observed beads' fracture frequency was 2 %, which confirmed the stability of the beads. The optimum operating conditions that arrived for better degradation were 0.5 g/L of nZVI, pH 6.2, and 400 mg H2O2/L. The treatment of effluent by this method increased the biodegradability index of the effluent, and the degradation data were found to follow pseudo first-order kinetics.  相似文献   

11.
A Fenton oxidation system employing zero-valent iron (whose source was swarf, a residue of metallurgical industries, in powder form) and hydrogen peroxide for the treatment of an aqueous solution with six pesticides was developed, and the effect of the iron metal content, pH, and hydrogen peroxide concentration was evaluated. The characterization of the aqueous solution resulted in: pH 5.6, 105 mg L?1 of dissolved organic carbon, and 44.6 NTU turbidity. In addition, the characterization of the swarf by FAAS and ICP-MS showed 98.43?±?7.40 % of zero-valent iron. The removal was strongly affected by the content of iron metal, pH, and hydrogen peroxide concentration. The best degradation conditions were 2.0 g swarf, pH 2.0, and 5 mmol L?1 H2O2. At the end of the treatment, the pesticide degradation ranged from 60 to 100 %, leading to 55 % mineralization. Besides, all hydrogen peroxide was consumed and the determination of total dissolved iron resulted in 2 mg L?1. Thus, the advantages of this system are rapid degradation (up to 20 min), high-degradation rates, simple handling, and low cost.
Figure
A Fenton oxidation system employing Fe0 (in which the source of Fe0 was swarf, a residue in powder form of metallurgical industries) and H2O2 for the degradation of synthetic wastewater comprising six pesticides was developed, and the effect of the amount of Fe0, pH, and H2O2 concentration was evaluated.  相似文献   

12.
The main disadvantage of using iron mineral in Fenton-like reactions is that the decomposition rate of organic contaminants is slower than in classic Fenton reaction using ferrous ions at acidic pH. In order to overcome these drawbacks of the Fenton process, chelating agents have been used in the investigation of Fenton heterogeneous reaction with some Fe-bearing minerals. In this work, the effect of new iron complexing agent, ethylenediamine-N,N'-disuccinic acid (EDDS), on heterogeneous Fenton and photo-Fenton system using goethite as an iron source was tested at circumneutral pH. Batch experiments including adsorption of EDDS and bisphenol A (BPA) on goethite, H2O2 decomposition, dissolved iron measurement, and BPA degradation were conducted. The effects of pH, H2O2 concentration, EDDS concentration, and goethite dose were studied, and the production of hydroxyl radical (?OH) was detected. The addition of EDDS inhibited the heterogeneous Fenton degradation of BPA but also the formation of ?OH. The presence of EDDS decreases the reactivity of goethite toward H2O2 because EDDS adsorbs strongly onto the goethite surface and alters catalytic sites. However, the addition of EDDS can improve the heterogeneous photo-Fenton degradation of BPA through the propagation into homogeneous reaction and formation of photochemically efficient Fe-EDDS complex. The overall effect of EDDS is dependent on the H2O2 and EDDS concentrations and pH value. The high performance observed at pH 6.2 could be explained by the ability of O 2 ?? to generate Fe(II) species from Fe(III) reduction. Low concentrations of H2O2 (0.1 mM) and EDDS (0.1 mM) were required as optimal conditions for complete BPA removal. These findings regarding the capability of EDDS/goethite system to promote heterogeneous photo-Fenton oxidation have important practical implications for water treatment technologies.  相似文献   

13.
The removal of radiocontrast agent diatrizoic acid (DIA) from water was performed using photo-Fenton (PF) process. First, the effect of H2O2 dosage on mineralization efficiency was determined using ultraviolet (UV) irradiation. The system reached a maximum mineralization degree of 60 % total organic carbon (TOC) removal at 4 h with 20 mM initial H2O2 concentration while further concentration values led to a decrease in TOC abatement efficiency. Then, the effect of different concentrations of Fenton’s reagents was studied for homogeneous Fenton process. Obtained results revealed that 0.25 mM Fe3+ and 20 mM H2O2 were the best conditions, achieving 80 % TOC removal efficiency at 4 h treatment. Furthermore, heterogeneous PF treatment was developed using iron-activated carbon as catalyst. It was demonstrated that this catalyst is a promising option, reaching 67 % of TOC removal within 4 h treatment without formation of iron leachate in the medium. In addition, two strategies of enhancement for process efficiency are proposed: coupling of PF with electro-Fenton (EF) process in two ways: photoelectro-Fenton (PEF) or PF followed by EF (PF-EF) treatments, achieving in both cases the complete mineralization of DIA solution within only 2 h. Finally, the Microtox tests revealed the formation of more toxic compounds than the initial DIA during PF process, while, it was possible to reach total mineralization by both proposed alternatives (PEF or PF-EF) and thus to remove the toxicity of DIA solution.  相似文献   

14.
In the present study, selected advanced oxidation processes (AOPs)—namely, photo-Fenton (with Fe2+, Fe3+, and potassium ferrioxalate—FeOx—as iron sources), solar photo-Fenton, Fenton, and UV/H2O2—were investigated for degradation of the antineoplastic drug mitoxantrone (MTX), frequently used to treat metastatic breast cancer, skin cancer, and acute leukemia. The results showed that photo-Fenton processes employing Fe(III) and FeOx and the UV/H2O2 process were most efficient for mineralizing MTX, with 77, 82, and 90 % of total organic carbon removal, respectively. MTX probably forms a complex with Fe(III), as demonstrated by voltammetric and spectrophotometric measurements. Spectrophotometric titrations suggested that the complex has a 2:1 Fe3+:MTX stoichiometric ratio and a complexation constant (K) of 1.47 × 104 M–1, indicating high MTX affinity for Fe3+. Complexation partially inhibits the involvement of iron ions and hence the degradation of MTX during photo-Fenton. The UV/H2O2 process is usually slower than the photo-Fenton process, but, in this study, the UV/H2O2 process proved to be more efficient due to complexing of MTX with Fe(III). The drug exhibited no cytotoxicity against NIH/3T3 mouse embryonic fibroblast cells when oxidized by UV/H2O2 or by UV/H2O2/FeOx at the concentrations tested.  相似文献   

15.
The treatment of 1,4-dioxane solution by electrochemical oxidation on boron-doped diamond was studied using a central composite design and the response surface methodology to investigate the use of SO4 2? and HCO3 ? as supporting electrolytes considering the applied electric current, initial chemical oxygen demand (COD) value, and treatment time. Two industrial effluents containing bicarbonate alkalinity, one just carrying 1,4-dioxane (S1), and another one including 1,4-dioxane and 2-methyl-1,3-dioxolane (S2), were treated under optimized conditions and subsequently subjected to biodegradability assays with a Pseudomonas putida culture. Electrooxidation was compared with ozone oxidation (O3) and its combination with hydrogen peroxide (O3/H2O2). Regarding the experimental design, the optimal compromise for maximum COD removal at minimum energy consumption was shown at the maximum tested concentrations of SO4 2? and HCO3 ? (41.6 and 32.8 mEq L?1, respectively) and the maximum selected initial COD (750 mg L?1), applying a current density of 11.9 mA cm?2 for 3.8 h. Up to 98 % of the COD was removed in the electrooxidation treatment of S1 effluent using 114 kWh per kg of removed COD and about 91 % of the COD from S2 wastewater applying 49 kWh per kg of removed COD. The optimal biodegradability enhancement was achieved after 1 h of electrooxidation treatment. In comparison with O3 and O3/H2O2 alternatives, electrochemical oxidation achieved the fastest degradation rate per oxidant consumption unit, and it also resulted to be the most economical treatment in terms of energy consumption and price per unit of removed COD.  相似文献   

16.
In this study, a three-factor, three-level Box-Behnken design with response surface methodology were used to maximize the TOC removal and minimize the H2O2 residual in the effluent of the combined UV-C/H2O2-VUV system for the treatment of an actual slaughterhouse wastewater (SWW) collected from one of the meat processing plants in Ontario, Canada. The irradiation time and the initial concentrations of total organic carbon (TOCo) and hydrogen peroxide (H2O2o) were the three predictors, as independent variables, studied in the design of experiments. The multiple response approach was used to obtain desirability response surfaces at the optimum factor settings. Subsequently, the optimum conditions to achieve the maximum percentage TOC removal of 46.19% and minimum H2O2 residual of 1.05% were TOCo of 213 mg L?1, H2O2o of 450 mg L?1, and irradiation time of 9 min. The attained optimal operating conditions were validated with a complementary test. Consequently, the TOC removal of 45.68% and H2O2 residual of 1.03% were achieved experimentally, confirming the statistical model reliability. Three individual processes, VUV alone, VUV/H2O2, and UV-C/H2O2, were also evaluated to compare their performance for the treatment of the actual SWW using the optimum parameters obtained in combined UV-C/H2O2-VUV processes. Results confirmed that an adequate combination of the UV-C/H2O2-VUV processes is essential for an optimized TOC removal and H2O2 residual. Finally, respirometry analyses were also performed to evaluate the biodegradability of the SWW and the BOD removal efficiency of the combined UV-C/H2O2-VUV processes.  相似文献   

17.
The paper presents results of the studies photodegradation, photooxidation, and oxidation of phenylarsonic acid (PAA) in aquatic solution. The water solutions, which consist of 2.7 g dm?3 phenylarsonic acid, were subjected to advance oxidation process (AOP) in UV, UV/H2O2, UV/O3, H2O2, and O3 systems under two pH conditions. Kinetic rate constants and half-life of phenylarsonic acid decomposition reaction are presented. The results from the study indicate that at pH 2 and 7, PAA degradation processes takes place in accordance with the pseudo first order kinetic reaction. The highest rate constants (10.45?×?10?3 and 20.12?×?10?3) and degradation efficiencies at pH 2 and 7 were obtained at UV/O3 processes. In solution, after processes, benzene, phenol, acetophenone, o-hydroxybiphenyl, p-hydroxybiphenyl, benzoic acid, benzaldehyde, and biphenyl were identified.  相似文献   

18.
Photocatalytic degradation of bisphenol A (BPA) in waters and wastewaters in the presence of titanium dioxide (TiO2) was performed under different conditions. Suspensions of the TiO2 were used to compare the degradation efficiency of BPA (20 mg L?1) in batch and compound parabolic collector (CPC) reactors. A TiO2 catalyst supported on glass spheres was prepared (sol–gel method) and used in a CPC solar pilot plant for the photodegradation of BPA (100 μg L?1). The influence of OH·, O2 ·?, and h + on the BPA degradation were evaluated. The radicals OH· and O2 ·? were proved to be the main species involved on BPA photodegradation. Total organic carbon (TOC) and carboxylic acids were determined to evaluate the BPA mineralization during the photodegradation process. Some toxicological effects of BPA and its photoproducts on Eisenia andrei earthworms were evaluated. The results show that the optimal concentration of suspended TiO2 to degrade BPA in batch or CPC reactors was 0.1 g L?1. According to biological tests, the BPA LC50 in 24 h for E. andrei was of 1.7?×?10?2 mg cm?2. The photocatalytic degradation of BPA mediated by TiO2 supported on glass spheres suffered strong influence of the water matrix. On real municipal wastewater treatment plant (MWWTP) secondary effluent, 30 % of BPA remains in solution; nevertheless, the method has the enormous advantage since it eliminates the need of catalyst removal step, reducing the cost of treatment.  相似文献   

19.
Sr-doped CuBi2O4 micro-particles were successively synthesized via a solid-state technique and were analyzed by X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray analysis (EDX), and UV–vis diffuse reflectance spectroscopy (UV–vis-DRS) techniques. Results show that Sr-doped CuBi2O4 was crystallized with a spinel-type structure and tetragonal crystal system, and the band gap energy was about 1.35 eV. The as-prepared Sr-doped CuBi2O4 treated at 573 °C for 12 h exhibited the highest efficiency, as a result of 97.22 % of CR degradation within 220 min, which is approximately 31 times greater than CR photodegradation when catalyzed by CuBi2O4 (3.13 %) and about 2.3 times superior than that catalyzed by the untreated Sr–doped CuBi2O4 sample (42.08 %). Pseudo-first-order kinetic model gave the best fit, with highest correlation coefficients (R 2?=?0.94–0.97). The Sr–doping and extending reaction time up to 12 h could be effective in producing Sr-doped CuBi2O4 materials that delay electron–hole recombination, thereby increasing the lifetime of the electron electron–hole separation and support the charge carrier transfer to the catalyst surface. On the basis of the calculated energy band positions, superoxide radical anions (O2 ?–) were the main oxidative species responsible for the photocatalytic degradation of CR dye solution.  相似文献   

20.
In the last few years, several works dealing with Fenton oxidation of ionic liquids (ILs) have proved the capability of this technology for their degradation, achieving complete ILs removal and non-toxic effluents. Nevertheless, very little is known about the kinetics of this process, crucial for its potential application. In this work, the effect of several operating conditions, including reaction temperature (50–90 °C), catalyst load (10–50 mg L?1 Fe3+), initial IL concentration (100–2000 mg L?1), and hydrogen peroxide dose (10–200% of the stoichiometric amount for the complete IL mineralization) on 1-butyl-3-methylimidazolium chloride ([C4mim]Cl) oxidation has been investigated. Under the optimum operating conditions (T = 90 °C; [Fe3+]0 = 50 mg L?1; [H2O2]0 = 100% of the stoichiometric amount), the complete removal of [C4mim]Cl (1000 mg L?1) was achieved at 1.5-min reaction time. From the experimental results, a potential kinetic model capable to describe the removal of imidazolium-based ILs by Fenton oxidation has been developed. By fitting the proposed model to the experimental data, the orders of the reaction with respect to IL initial concentration, Fe3+ amount and H2O2 dose were found to be close to 1, with an apparent activation energy of 43.3 kJ mol?1. The model resulted in a reasonable fit within the wide range of operating conditions tested in this work.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号