1.
Newspapers impregnated with NaCl mixed with various chloride metals (CuCl2, MgCl2, MnCl2, FeCl3, NiCl2, and CoCl2) and electric wire coated with polyvinyl chloride (PVC) were combusted in a well-controlled incinerator. Exhaust gas samples collected at the outlet of the incinerator were analyzed for dioxins (PCDDs, PCDFs, and coplanar PCBs) by gas chromatography/mass spectrometry. The amount of total dioxins formed from newspaper samples ranged from 34.2 ng/g (with NaCl+CoCl2) to 67.0 ng/g (with NaCl+CuCl2). PCDFs composed 88-94% of the total dioxins formed in the exhaust gases. The highest levels of PCDF isomers obtained were Cl3-CDF from the sample with NaCl+CuCl2 (14.8 ng/g), Cl2-CDF from the sample with NaCl+MgCl2 (12.3 ng/g), and Cl(1)-CDF from samples with NaCl+MnCl2 (12.6 ng/g), with NaCl+FeCl3 (11.8 ng/g), and with NaCl+NiCl2 (13.3 ng/g), and with NaCl+CoCl2 (8.62 ng/g). The total of Cl4-8-CDDs comprised 76-88% of the total Cl1-8-CDDs. In particular, Cl7-CDDs had the highest levels except for the sample with NaCl+NiCl2. Total dioxins formed from samples of electric wire coated with PVC and PVC alone were 38.3 ng/g and 112 ng/g, respectively, suggesting that the presence of copper reduced dioxin formation.  相似文献   

2.
Thirty-one samples of baked-salt products used in commercial food additives were analyzed for the presence of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). Dioxins were highly detected in 12 samples of baked salts. The amount of dioxins found in the samples ranged from 12.47 pg/g to 406.56 pg/g (0.71 pg TEQ/g to 23.51 pg TEQ/g, respectively). The most abundant congeners, as TEQ values, were 2,3,4,7,8-PeCDF; 1,2,3,7,8-PeCDF; and 1,2,3,4,7,8-HxCDF in PCDF congeners and 1,2,3,7,8-PeCDD; 1,2,3,6,7,8-HxCDD; and 1,2,3,7,8,9-HxCDD in PCDD congeners. Meanwhile, PCDDs/PCDFs were analyzed in high-temperature-treated samples of natural sea salt alone and natural sea salt to which di-(2-ethylhexyl)phthalate (DEHP) had been added. In the former case, PCDD/PCDF formation was most evident at temperatures near 450 degrees C, the total amount of dioxins was 90.07 pg/g (6.07 pg TEQ/g), and PCDD congeners comprised less than 50% of the total PCDDs/PCDFs. However, when the latter samples were heated, the total PCDD/PCDF concentration was 512.30 pg/g (21.53 pg TEQ/g), with PCDD congeners comprising over 87% of the total PCDDs/PCDFs.  相似文献   

3.
In laboratory-scale combustion of polyvinylidene chloride (PVDC) with a quartz tubular furnace designed and fabricated to provide the desired combustion temperature and mixing state of combustion gas with air, it was found that at 800 degrees C or higher the level of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans [corrected] (PCDDs/PCDFs) resulting from PVDC combustion was no higher than that from heating air alone, and thus far below the levels which resulted from PVDC combustion at 750 degrees C or lower. The results provide the first laboratory confirmation of the relation between PVDC incineration temperature and PCDD/PCDF formation, and of the primary importance of high temperature, turbulence for mixing between air and combustion gas, and sufficient residence time, as governing factors for the minimization of PCDD/PCDF formation in municipal solid waste incinerators.  相似文献   

4.
Hatanaka T  Imagawa T  Takeuchi M 《Chemosphere》2003,51(10):1041-1046
Combustion experiments in a laboratory-scale fluidized-bed reactor were conducted to elucidate the effects of copper chloride as a catalyst on polychlorinated dibenzo-p-dioxins (PCDDs) formation in municipal waste incineration. We used model wastes with and without copper chloride (CuCl2 · 2H2O), both of which contained polyvinyl chloride as a chlorine source. Combustion temperature was set to 900 °C, and the amount of air supplied was twice the stoichiometric ratio. The experimental setup was carefully planned to suppress the influences of experimental conditions except the waste composition. Results of these experiments showed that copper chloride in the waste increased the amount of PCDDs formed and made the homologue profile to shift towards the highly chlorinated species. Copper chloride contributes to the PCDDs formation by promoting chlorination, whereby the reaction is important in that organic matter is chlorinated directly by copper compounds. Copper chloride did not exert a great influence on the isomer distribution patterns of PCDDs, while there appeared a significant difference in the case of PCDFs. This points out the difference of the major formation mechanisms between PCDDs and PCDFs. PCDDs are less formed by the catalytic reactions from carbon/polycyclic aromatic hydrocarbons than PCDFs in our experimental conditions.  相似文献   

5.
Processed ball clay samples used in the production of ceramics and samples of the ceramic products were collected and analyzed for the presence and concentration of the 2,3,7,8-Cl substituted polychlorinated dibenzo-p-dioxins and -furans (PCDDs/PCDFs). The processed ball clay had average PCDD concentrations of 3.2 ng/g toxic equivalents, a congener profile, and isomer distribution consistent with those found previously in raw ball clay. The PCDF concentrations were below the average limit of detection (LOD) of 0.5 pg/g. The final fired ceramic products were found to be free of PCDDs/PCDFs at the LODs. A consideration of the conditions involved in the firing process suggests that the PCDDs, if not destroyed, may be released to the atmosphere and could represent an as yet unidentified source of dioxins to the environment. In addition, the PCDDs in clay dust generated during manufacturing operations may represent a potential occupational exposure.  相似文献   

6.
Two samples of tab water and double distilled water were chlorinated using chlorine gas. A series of PCDFs could be identified from these experiments, however no PCDDs could be found. The two water samples gave very similar isomeric patterns ( . . tetra-CDFs), however the congener profile (Cl4 --- Cl8) was different. These experiments indicate that all products formed by chlorination reactions are potentially contaminated by PCDFs by a specific “chlorine pattern”.  相似文献   

7.
Ferrario J  Byrne C 《Chemosphere》2002,46(9-10):1297-1301
Processed ball clay samples used in the production of ceramics and samples of the ceramic products were collected and analyzed for the presence and concentration of the 2,3,7,8-Cl substituted polychlorinated dibenzo-p-dioxins and -furans (PCDDs/PCDFs). The processed ball clay had average PCDD concentrations of 3.2 ng/g toxic equivalents, a congener profile, and isomer distribution consistent with those found previously in raw ball clay. The PCDF concentrations were below the average limit of detection (LOD) of 0.5 pg/g. The final fired ceramic products were found to be free of PCDDs/PCDFs at the LODs. A consideration of the conditions involved in the firing process suggests that the PCDDs, if not destroyed, may be released to the atmosphere and could represent an as yet unidentified source of dioxins to the environment. In addition, the PCDDs in clay dust generated during manufacturing operations may represent a potential occupational exposure.  相似文献   

8.
Polychlorodibenzo-p-dioxins (PCDDs), polychlorodibenzofurans (PCDFs), polychloronaphthalenes (PCNs) and coplanar PCBs were measured in surface sediments from 18 lake areas in Central Finland. Toxic 2, 3, 7, 8-substituted PCDD and PCDF congeners occurred at low levels (<20 − 230 pg/g dw). PCNs appeared at few ng/g (total PCNs) levels. Pulp mills or any other local sources could not be associated with the sedimented PCDDs, PCDFs and PCNs. Coplanar PCB congeners 77 and 105 (IUPAC Nr) were generally found at 20–550 pg/g levels. The most toxic congener 126 was measured (110 pg/g) only at one area near a local PCB leakage. Pulp mill originated aromatic chlorocompounds which coelute with PCDDs and PCDFs in clean up, probably alkyl polychlorobibenzyls (R-PCBBs) appeared at ng/g levels and showed a clear gradient dowstreams from pulp mill effluent points.  相似文献   

9.
PCDDs and PCDFs in vehicle exhaust particles in Japan.   总被引:6,自引:0,他引:6  
Vehicle exhaust particles from gasoline and diesel engine cars were analyzed for PCDDs and PCDFs. The congener patterns of PCDDs and PCDFs in exhaust particles were different between gasoline and diesel engine cars. Suspended particulate matter from electrostatic precipitator connected to a highway tunnel was also analyzed for PCDDs and PCDFs. The congener pattern of suspended particular matter was different from both of gasoline and diesel engine cars. Total amounts of PCDDs/PCDFs sum concentrations in gasoline, diesel and suspended particulate matter were 0.21, 0.87 and 26.0 ng/g, respectively. The I-TEQs levels in gasoline, diesel and suspended particulate matter were 4.2, 11 and 242 pg/g, respectively.  相似文献   

10.
The subject of this study was to develop a method of simultaneous determination of PCDDs/PCDFs and HCB in exhaust gases from industrial installations. Sampling to determine PCDDs/PCDFs was conducted using the method described in PN-EN 1948-1: 2006, where the sorption material is polyurethane foam (PUF). In order to simultaneously collect PCDDs/PCDFs and HCB and to avoid sorbent bed breakthrough, it was necessary to apply an additional polyurethane sorption layer. Twenty-seven samples of exhaust gases from various cement plants and 40 samples of exhaust gases from hospital and industrial waste incineration plants collected in 2009/2010 in the entire territory of Poland were examined. The average content of PCDDs/Fs in samples from cement plants amounted to 0.076 ng I-TEQ N m(-3) (range of 0.002-0.62 ng I-TEQ N m(-3)), while the average content of HCB amounted to 10 ng N m(-3) (range of 0.98-60.5 ng N m(-3)). In the case of samples collected from waste incineration plants, the average concentration of PCDDs/Fs was 0.39 ng I-TEQN m(-3) (range of 0.002-5.68 ng I-TEQ N m(-3)). In the case of HCB, the average concentration was 238 ng N m(-3) (range of 3.21-2500 ng N m(-3)). Also, the interdependence of the concentration of PCDDs/PCDFs and HCB was determined in the analysed samples, with the ranges of low and high content of PCDDs/PCDFs being examined separately. In all cases, the determined values of the r correlation coefficient were within the range of 0.7-1.0, which indicates a good correlation between the concentrations of PCDDs/PCDFs and HCB.  相似文献   

11.
Moore S 《Chemosphere》2002,49(2):121-125
The analysis of polychlorinated dioxins and furans (PCDDs/PCDFs) can produce erroneous results when polychloro diphenyl ethers (PCDEs) are present because they fragment and rearrange under electron ionization to give isobaric ions with PCDFs. Mass information must be generated to indicate the occurrence of possible PCDEs but uncertainty still exists if a PCDE congener has the same retention time as a PCDF congener. The metastable atom bombardment (MAB) ion source does not transfer enough energy to PCDE upon ionization to fragment the molecular ion, thus eliminating the need for PCDE tracking in PCDF analysis. Experiments were conducted with different gases, representing different ionization energies, to demonstrate that PCDE interference can be eliminated from PCDF analysis.  相似文献   

12.
Studies on the formation of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) during the electrolysis of sodium chloride solution (brine) using graphite or titanium electrodes were carried out at a laboratory scale. High concentrations of PCDFs but no PCDDs were formed in tests using graphite electrodes. With titanium electrodes, PCDFs were only formed when tar pitch was added and mainly originated from the dibenzofuran present in the tar. For the first time, a detailed assessment of the formation of mono- to octachlorinated PCDD/PCDF from tar pitch was investigated. The assessment included of the chlorination steps proved that PCDFs were formed by successive lateral chlorinated from dibenzofuran to MonoCDFs, DiCDFs, and TriCDFs to form the typical known “chlorine pattern” of TetraCDF to OctaCDF with a dominance of 1,2,7,8- and 2,3,7,8-TetraCDFs, 1,2,3,7,8-PentaCDF, and 1,2,3,4,7,8-HexaCDF as marker congeners. The final homologue distributions depended on reaction time and reaction temperature. In addition, electrolysis with non-chlorinated dibenzo-p-dioxins, dibenzofuran, and biphenyl was carried out. As a result, PCDDs, PCDFs, and PCB were formed at comparable yields. Congener patterns in soil samples from a PCDD/F-contaminated site where chlor-alkali electrolysis had been operated for decades in Japan had identical isomer distribution demonstrating the source and contamination potential and risk of these processes. Therefore, sites where in the past 120 years chlor-alkali electrolysis has been operated or where residues from chlor-alkali production or other chlorine using industries have been disposed should be assessed for their pollution level and exposure relevance. The assessment of total organohalogen content revealed that PCDF is only a small fraction of organohalogens in the contaminated soils. For an appropriate risk assessment, also other chlorinated aromatic compounds such as PCBs or PCNs need to be considered.  相似文献   

13.
Estonia still has no waste incineration facilities, which would act as substantial sources of dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) pollution. As landfill fires may serve as sources of dioxins, we focused on the concentrations of PCDD and PCDF in soil samples taken in the vicinity of the landfill located at south-east Estonia in the course of our inventory. Concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were studied in five soil samples taken in the vicinity of the Laguja landfill in south-east Estonia. The four soil samples were taken in southern, eastern, western and northern parts not further than 300 m from the landfill, and one sample was taken at the distance of 3 km from the landfill. The PCDD/F concentrations in all soil samples were at background level (0.64-2.33 pg I-TEQ WHO/g dry weight). To maintain this situation, the administrator of the landfill must avoid landfill fires, which are one of the reasons for the generation of dioxins and furans.  相似文献   

14.
Combustion experiments in a laboratory-scale fluidized-bed reactor were conducted to elucidate the effects of copper chloride as a catalyst on polychlorinated dibenzo-p-dioxins (PCDDs) formation in municipal waste incineration. We used model wastes with and without copper chloride (CuCl2 · 2H2O), both of which contained polyvinyl chloride as a chlorine source. Combustion temperature was set to 900 °C, and the amount of air supplied was twice the stoichiometric ratio. The experimental setup was carefully planned to suppress the influences of experimental conditions except the waste composition. Results of these experiments showed that copper chloride in the waste increased the amount of PCDDs formed and made the homologue profile to shift towards the highly chlorinated species. Copper chloride contributes to the PCDDs formation by promoting chlorination, whereby the reaction is important in that organic matter is chlorinated directly by copper compounds. Copper chloride did not exert a great influence on the isomer distribution patterns of PCDDs, while there appeared a significant difference in the case of PCDFs. This points out the difference of the major formation mechanisms between PCDDs and PCDFs. PCDDs are less formed by the catalytic reactions from carbon/polycyclic aromatic hydrocarbons than PCDFs in our experimental conditions.  相似文献   

15.
Polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (DL-PCBs) contained in the smoke generated from rice straw burning in post-harvest paddy fields in Japan were analyzed to determine their congener profiles. Both the apportionment of toxic equivalent (TEQ) by using indicative congeners and the comparison of the homolog profiles showed that the PCDDs/PCDFs/DL-PCBs present in the rice-straw smoke were greatly influenced by those present as impurities in pentachlorophenol (PCP) and chlornitrofen (CNP, 4-nitrophenyl-2,4,6-trichlorophenyl ether) formulations that had been widely used as herbicides in paddy fields in Japan. Further, in order to investigate the effects of paddy-field soil on the PCDDs/PCDFs/DL-PCBs present in rice-straw smoke, PCDD/PCDF/DL-PCB homolog profiles of rice straw, rice-straw smoke and paddy-field soil were compared. Rice-straw smoke was generated by burning rice straw on a stainless-steel tray in a laboratory. The results suggested that the herbicides-originated PCDDs/PCDFs/DL-PCBs and the atmospheric PCDDs/PCDFs/DL-PCBs contributed predominantly to the presence of PCDDs/PCDFs/DL-PCBs in the rice-straw smoke while the contribution of PCDDs/PCDFs/DL-PCBs formed during rice straw burning was relatively minimal. The major sources of the PCDDs/PCDFs/DL-PCBs found in the rice-straw smoke were attributed primarily to the paddy-field soil adhered to the rice straw surface and secondarily to the air taken by the rice straw. The principal component analysis supported these conclusions. It is concluded that rice straw burning at paddy fields acts as a driving force in the transfer of PCDDs/PCDFs/DL-PCBs from paddy-field soil to the atmosphere.  相似文献   

16.
In this paper the results of sampling for trace chlorinated organics at two municipal refuse incinerators in Ontario are presented. The information may be of Interest to individuals concerned with the assessment of PCDD/PCDF (polychlorinated dibenzo-p-dioxin/polychlorinated dibenzofuran) emissions from incineration of refuse and their impact on the energyfrom- waste program. PCDDs, PCDFs, PCBs (polychlorinated biphenyls), CBs (chlorobenzenes) and CPs (chlorophenols) were quantified in all process streams including refuse, ash and stack emissions. Manual sorting of refuse and collection of ash samples were carried out simultaneously with three 24-hour continuous stack sampling tests at each plant. The results suggested that the total output of PCDDs and PCDFs varied proportionately with their input at both incinerators. However, the input of PCDDs/PCDFs could not account for their total output. The chemistry of PCDDs/PCDFs in the input and output streams were different in that only heptachlorinated and octachlorinated species were present in significant quantities in the refuse while lower chlorinated species were predominant in stack emissions and ash streams. There was no correspondence between the Input of PCBs/CBs/CPs and the output of PCDDs/PCDFs. The output of PCDDs/PCDFs, however, varied Inversely with the total output of PCBs/CBs/CPs, suggesting that the latter compounds could have been partially responsible for the formation of PCDDs and PCDFs. The PCDF emissions were also affected by combustion conditions; they were higher in magnitude and consisted of predominantly tetrachlorinated and pentachlorinated species at the plant where the combustion temperatures were lower.  相似文献   

17.
Different 2,3,7,8-substituted polychlorinated dibenzodioxins (PCDDs) and dibenzofurans (PCDFs) were investigated for their retention behaviour on a disposable minicolumn containing activated carbon AX-21. Elution behaviour and recovery were examined, using native and radiolabelled PCDD and PCDF isomers.

A comparison of the total mass chromatograms of PCDDs and PCDFs in an extract from animal adipose tissue, before and after activated carbon treatment, demonstrates the efficiency of this cleanup step with respect to the elimination of interfering compounds.  相似文献   


18.
Suspended sediments from the Detroit River were collected in 1999 and 2000 using sediment traps at sites ranging from western Lake Erie to southern Lake St. Clair and analyzed to determine the spatial distributions of contaminants including polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/PCDFs), dioxin-like PCBs (DLPCBs) and polychlorinated naphthalenes (PCNs). Concentrations of all three contaminant classes were clearly elevated at sites in the lower reaches of the river in the Trenton Channel. The potential influence of the Trenton Channel as a source of contamination to western Lake Erie was further evidenced by PCDD/PCDF homologue profiles, which indicated a contribution from chemical manufacturing in addition to the normal background combustion profile. Toxic equivalents (TEQs) for PCDDs/PCDFs generally exceeded those for DLPCBs; combined total TEQs in July 2000 for these two compound classes ranged from 2.30 pg/g in southern Lake St. Clair to 306 pg/g at a station just downstream of the outflow of Monguagon Creek in the Trenton Channel. The spatial distribution of PCN contamination was similar to that of PCDDs/PCDFs and DLPCBs, with the highest level of total PCNs (8200 ng/g) detected at a site in the Trenton Channel near Elizabeth Park; TEQs for PCNs in the Trenton Channel ranged from 73 to 3300 pg/g. The data indicate that PCNs represent a significant contribution to dioxin-like biological activity in Detroit River suspended sediments.  相似文献   

19.
Weber R 《Chemosphere》2007,67(9):S109-S117
One important criterion for assessment of a POPs destruction technology is the potential formation of new POPs and other toxic by-products, in particular whether the highly toxic PCDDs/PCDFs are formed and under which operation conditions their formation is relevant. For incineration processes the formation mechanisms of PCDDs/PCDFs have been investigated thoroughly and strategies and technologies were developed to minimize their formation and emission. A detailed assessment of non-combustion technologies with respect to PCDD/PCDF formation is, however, lacking to date. A comparison of reaction conditions for PCDD/PCDF formation from precursor formation studies and actual applied conditions of a broad range of POPs destruction technologies in the present paper indicates that the operation conditions for a number of destruction technologies have the potential to generate high concentrations of PCDDs/PCDFs if dioxin precursors are present and that also PCDD/PCDF de novo formation can take place. Therefore a strategy and regulations for a more profound assessment and monitoring of the fate of PCDD/PCDF formation and emission is essential for the evaluation of POP destruction technologies and for a sound risk management of POPs. The present paper aims to provide a critical impulse in this respect, discusses the relevant formation pathways with respect to POPs destruction technologies and proposes a basic framework on how evaluations may be performed.  相似文献   

20.
Laboratory bleaching experiments were performed to investigate PCDD/PCDF formation mechanisms. The results indicated that there were two (or more) mechanisms; direct chlorination of DBD/DBF and formation from precursors which are not extractable. In general, PCDDs/PCDFs are formed in the C stage but some minor isomers were found to be formed in the E stage.  相似文献   