首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The removal performance of typical refractory organic compounds in landfill leachate was investigated during the electrochemical (EC) oxidation and anaerobic process combined treatment system in this paper. The results indicated that the treatment of landfill leachate by the combined system was highly effective. The toxicity of leachate was notably decreased after the electrochemical oxidation process and the biodegradability was improved. The concentration of the organic acid with low molecular weight in the leachate increased from 28% to 90% based on the biodegradability assays after the EC oxidation process. The anaerobic digestion could further remove the residual organic compounds. At a hydraulic retention time (HRT) of 16 hours and an organic loading rate (OLR) of 8 kg COD/m3 d, the concentration of COD, SS, ALK, VA, N-TKN, N-NH4+ and P-PO4(3)- [corrected] in UASB effluent were 532, 12, 6744, 400, 540, 455 and 11.6 mg/L, respectively, with approximately 90% removal efficiency of COD. The organic compounds in the landfill leachate revealed different degradation characteristics in the combined system. p-chloroaniline, bisphenol A, 6-methyl-2-phenyl-quinoline, dimethylnaphthaline and N'-(2-methyl-4-chlorophenyl)-N-cyclohexyformamidine, classified into the first group in this paper, were completely removed by the EC oxidation and did not reappear in the effluent of the UASB reactor. Phenylacetic acid, 3-methyl-indole and N-cyclohexyl-acetamide, called the second group, were completely removed, but reappeared in the UASB reactor. 4-methyl-phenol, 3,4-dihydroisoquinoline, 2(3H)-benzothiazolone, exo-2-hydroxycineole and benzothiazole, the third group, were degraded little in the EC oxidation process, but extensively removed by the anaerobic process. Benzoic acid, benzenepropanoic acid and 2-cyano-3,5-dimethyl-1-hydroxypyrrole, the fourth group, concentration obviously increased in the EC process, but was completely removed in the UASB reactor. The content of volatile fatty acids (VFAs) markedly increased from 0.68% in the leachate to 16.18% in the effluent from the electrochemical oxidation process (EC(effl)). In addition, the degradation rate of organic compounds from the landfill leachate was different in the EC oxidation and anaerobic process.  相似文献   

2.
以模拟城市污水为处理对象,采用循环式活性污泥法(CAST)反应器,对交替缺氧/好氧模式下系统去除污染物的性能进行了研究。结果表明,运行期间系统内有机物的去除率稳定,出水COD小于40 mg/L,COD平均去除率为91.7%;NH4+-N、TN的平均去除率分别为83.9%、72.4%,出水TN以NO3--N为主;系统的除磷性能良好,磷酸盐的平均去除率为90.6%。此外,出水COD、TN和TP均达到《城镇污水处理厂污染物排放标准》(GB-18918-2002)的一级A要求。  相似文献   

3.
In this paper, a comparison of various advanced oxidation processes (O3, O3/UV, H2O2/UV, O3/H2O2/UV, Fe2+/H2O2) and chemical treatment methods using Al2(SO4)3.18H2O, FeCl3 and FeSO4 for the chemical oxygen demand (COD) and color removal from a polyester and acetate fiber dyeing effluent is undertaken. Advanced oxidation processes (AOPs) showed a superior performance compared to conventional chemical treatment, which maximum achievable color and COD removal for the textile effluent used in this study was 50% and 60%, respectively. Although O3/H2O2/UV combination among other AOPs methods studied in this paper was found to give the best result (99% removal for COD and 96% removal for color), use of Fe2+/H2O2 seems to show a satisfactory COD and color removal performance and to be economically more viable choice for the acetate and polyester fiber dyeing effluent on the basis of 90% removal.  相似文献   

4.
按照水质情况,将多种来源于不同工业生产过程中的高浓度有机废水划分为高悬浮固体乳化液废水、难生化高浓度有机废水、高悬浮固体不含油有机废水、含铬有机废水和杂质含量较少的乳化液废水5类,分别采用酸化破乳/Fen-ton氧化/混凝/絮凝、Fenton氧化/混凝/絮凝、混凝/絮凝、还原/混凝/絮凝、震动膜过滤技术作为生化预处理技术,并通过小试和中试验证了各技术的效果。实验结果表明,按照上述分类结果,采用不同预处理技术可以得到良好的效果,废水水质明显改善,满足继续生化处理的基本条件。各预处理生产装置处理效果稳定,同时生化系统已经稳定运行120天以上,COD去除率超过90%,出水经过低剂量的Fenton试剂处理后可达到《污水排入城镇下水道水质标准》(CJ343-2012)。  相似文献   

5.
组合人工湿地处理工业园区污水厂尾水的中试研究   总被引:3,自引:0,他引:3  
杨林  李咏梅 《环境工程学报》2012,6(6):1846-1850
在巢湖流域水环境治理中,依托工业园区污水厂,进行了组合人工湿地处理工业园区污水厂尾水的中试研究。介绍了工艺流程和设计参数,运行结果表明,整个处理系统运行稳定,对COD、NH4+-N和TP的平均去除率分别为65.5%、75.5%和49.2%,其中一级潜流湿地对各污染物的去除贡献率最高。系统出水COD、氨氮、总磷基本达到了《地表水环境质量标准》(GB3838-2002)中的Ⅴ类水标准。此外还利用GC/MS初步对系统进出水进行了有机物组分分析,结果表明尾水中含有除草剂及农药中间体等难降解有机物,组合人工湿地对这些物质有一定去除效果。  相似文献   

6.
A petroleum refinery secondary effluent was treated using two freezing techniques--spray freezing and unidirectional downward freezing (UDF). The freezing processes were effective to remove toxicity and total organic carbon (TOC)- and chemical oxygen demand (COD)-causing materials in the effluent. Agitation of the liquid during UDF significantly improved the impurity separation efficiency; 85 to 96% removal of TOC and COD was achieved without any pretreatment and freezing only 70% of the feed water. The treatment efficiency of the spray freezing was at the same level as that of UDF without mixing. The spray ice with longer storage time released more contaminants with early meltwater. The initial contaminant concentration of the feed water and the freezing temperatures (-10 degrees C and -25 degrees C) had no significant influence on the treatment efficiency. A small fluctuation in effluent TOC concentration caused a dramatic change in effluent toxicity (Microtox). The effective concentration (EC20) (Microtox) was effective in detecting effluent toxicity.  相似文献   

7.
Yang Z  Zhou S 《Chemosphere》2008,72(11):1751-1756
A set of simultaneous aerobic and anaerobic (SAA) bio-reactor system was used for the removal of organic pollutants and ammonia in the landfill leachate generated from Datian Shan Landfill in Guangzhou, China. The influent concentrations of COD and NH(4)(+)-N were 1000-3300 and 80-230 mg L(-1), respectively. The average effluent concentrations of COD and NH(4)(+)-N were 131 and 7 mg L(-1), respectively. The concentrations of COD and NH(4)(+)-N had reached the Chinese second grade effluent standard (COD<300 mg L(-1), NH(4)(+)-N<25 mg L(-1)) for this kind of wastewater. Gas chromatogram-mass spectrum (GC/MS) analysis was used to measure the organic pollutants in the landfill leachate. About 87 organics were detected in this landfill leachate, and 16 of them belong to the list of environmental priority pollutants established by the US Environmental Protection Agency. About 31 of the 87 organic pollutants were completely removed by the SAA bio-reactor, the concentrations of further 14 organic pollutants were reduced by more than 80%, and the removal efficiencies of the other 25 organic pollutants were over 50%.  相似文献   

8.
The electrochemical oxidation of the biotic degradation products of the textile dye C.I. Acid Orange 7 (AO7) was achieved using a boron doped diamond electrode (BDD). Tests were performed with model solutions of the biotic degradation products, sulphanilic acid (SA) and 1-amino-2-naphthol (AN), and also with real effluents obtained in experiments carried out in an up-flow anaerobic sludge blanket (UASB) reactor, fed with a simulated textile effluent containing AO7, working in mesophilic or thermophilic conditions. Bulk electrolysis was studied using two different supporting electrolytes - NaCl and Na(2)SO(4). The influence of initial metabolite concentration and current density on the electrodegradation rates of the biotic products was investigated. For the UASB effluents, oxidation tests were carried out for different electrolytes and at different current densities. Samples were collected at pre-selected intervals and absorbance measurements, chemical oxygen demand (COD) and total organic carbon (TOC) tests and high performance liquid chromatography (HPLC) analysis were performed. Results have shown an almost complete elimination of the persistent pollutants and a COD removal higher than 70% for both AN and SA. For the UASB effluents, COD removals between 45% and 90% and TOC removals varying from 19% to 41% were obtained.  相似文献   

9.
The effect of influent nitrogen composition on organic nitrogen production in a sequencing batch reactor (SBR) activated sludge process was investigated. A laboratory-scale SBR was fed with three different type synthetic wastewaters with varying nitrogen compositions (phase I = nitriloacetic acid + ammonium [NH4-N], phase II = NH(4-)N, and phase III = amino acid mixture + NH(4-)N) was operated. The effluent contained approximately 1 to 2 mg N/L organic nitrogen, even though there was no organic nitrogen in influent. The effluent organic nitrogen increased to approximately 4 mg N/L when the influent composition was changed and then stabilized at <2 mg N/L. The maximum nitrifier growth rate constants (microN) were calculated as 0.91+/-0.10 to 1.14+/-0.08 day-1, 0.82 +/-0.13 day-1, and 0.89+/-0.08 day-1 at 20 degrees C for the three different influent compositions. The effluent colloidal organic nitrogen (CON) was negligible, suggesting that the effluent CON found in full-scale plants may be the result of influent-derived suspended matter.  相似文献   

10.
Wang J  Long MC  Zhang ZJ  Chi LN  Qiao XL  Zhu HX  Zhang ZF 《Chemosphere》2008,71(1):195-202
Wastewater in Shaoxing wastewater treatment plant (SWWTP) is composed of more than 90% dyeing and printing wastewater with high pH and sulfate. Through a combination process of anaerobic acidogenic [hydraulic retention time (HRT) of 15h], aerobic (HRT of 20h) and flocculation-precipitation, the total COD removal efficiency was up to 91%. But COD removal efficiency in anaerobic acidogenic unit was only 4%. As a comparison, the COD removal efficiency was up to 35% in the pilot-scale upflow anaerobic sludge bed (UASB) reactor (HRT of 15h). GC-MS analysis showed that the response abundance of these wastewater samples decreased with their removal of COD. A main component of the raw influent was long-chain n-alkanes. The final effluent of SWWTP had only four types of alkanes. After anaerobic unit at SWWTP, the mass percentage of total alkanes to total organic compounds was slightly decreased while its categories increased. But in the UASB, alkanes categories could be removed by 75%. Caffeine as a chemical marker could be detected only in the effluent of the aerobic process. Quantitative analysis was given. These results demonstrated that GC-MS analysis could provide an insight to the measurement of organic compounds removal.  相似文献   

11.
原位臭氧氧化污泥减量工艺的运行效能   总被引:1,自引:0,他引:1  
采用ASBR/SBR原位臭氧污泥减量工艺,重点研究了原位臭氧氧化对SBR段污泥产率和出水水质的影响。两个相同的ASBR/SBR组合工艺同时运行,每隔3个周期向臭氧投加组SBR的曝气阶段原位间歇投加臭氧,臭氧投加量为0.027 g O3/g MLSS,连续运行40 d;对照组不投加臭氧作为对比。结果表明,原位臭氧氧化实现污泥减量约43.9%,臭氧投加组SBR段平均污泥产率系数为0.1447 g SS/g SCOD,而对照组为0.2580 g SS/g SCOD,投加组没有惰性污泥的累积,并且污泥沉淀性能得到改善。原位臭氧氧化对出水水质影响不大,投加组与对照组相比,臭氧投加3周期后的出水COD、NH4+-N、TN和TP平均值分别为47.8、0.76、14.1和6.4 mg/L,去除率分别下降了4%、2%、3%和7.7%,其中COD、NH4+-N和TN均能达到《城镇污水处理厂污染物排放标准》(GB18918-2002)一级A标准。  相似文献   

12.
将新型CAMBR反应器(厌氧折流板反应器(ABR)与膜生物反应器(MBR)优化组合)用于处理生活污水,研究温度对该反应器处理效能的影响。实验水力停留时间7.5h,混合液回流比设置为200%,pH值为6.5~8.5,溶解氧3mg/L左右。控制3个温度梯度:高温(32~37%),中温(20~25℃),低温(5~10%),每个温度运行35d。结果表明,在高温条件下,系统出水COD、NH4.N、TN和TP平均浓度分别为25、0.5、12.5和0.7mg/L。在中温条件下,系统出水COD、NH4+-N、TN和TP浓度分别30、1.2、12.5和0.4mg/L。在低温条件下,COD和TP分别经过15d和20d调整适应,出水可恢复至35mg/L和1mg/L。由于低温(10%以下)对硝化细菌产生强烈抑制,出水NH4+-N去除率最终稳定在35%,TN去除率为40%。低温条件下,该反应器应用于污水处理中需注意适当保温,以保证出水水质。  相似文献   

13.
采用Fenton氧化开展了对高浓度造纸废水深度处理的中试实验,对Fenton氧化的COD的去除效果,各药剂加药量及成本,排泥量和装置运行的稳定性等进行探讨和分析,结果表明,一级Fenton氧化的COD去除率可达到90%以上,出水COD在100mg/L左右,总加药成本在6元左右,排泥量约为1~1.2kg/t废水;二级Fenton氧化的COD去除率在96%左右,出水COD小于60mg/L,总加药成本在8元左右,排泥量约为1.15~1.4kg/t废水,验证了Fenton氧化用于高浓度造纸废水深度处理达到新的排放标准的可行性。  相似文献   

14.
Chowdhury N  Nakhla G  Zhu J 《Chemosphere》2008,71(5):807-815
A novel liquid-solid circulating fluidized bed bioreactor (LSCFB) configured with anoxic and aerobic columns and lava rock as the biofilm carrier was used to treat synthetic municipal wastewater. Four different empty bed contact times (EBCTs) of 0.82, 0.65, 0.55, and 0.44 h were examined to optimize nutrient removal capability of the system. The LSCFB demonstrated tertiary effluent quality organic and nitrogen removal efficiencies. Effluent characteristics of the LSCFB were soluble biological oxygen demand (SBOD)10 mg l(-1) and total nitrogen (TN)<10 mg l(-1) at organic loading rate (OLR) of 5.3 kg m(-3)d(-1) and nitrogen loading rate of 0.54 kg Nm(-3)d(-1). Remarkably low yields of 0.14, 0.17, 0.19, and 0.21 g VSS g(-1)COD were observed at OLR of 2.6, 3.2, 4.1 and 5.3 kg COD m(-3)d(-1), where increment of biomass growth and detachment rate were also experienced with increasing OLR. However the system demonstrated only 30% phosphorus removal, and mass balances along the anoxic and aerobic columns showed biological phosphorus removal in the system. Organic mass balance showed that approximately 40% of the influent COD was utilized in the anoxic column and the remaining COD was oxidized in the aerobic column. The system is very efficient in nitrification-denitrification, with more than 90% nitrification of ammonium and overall nitrogen removal in the LSCFB was 70+/-11% even at an EBCT of 0.44 h.  相似文献   

15.
采用膨胀颗粒污泥床(EGSB)反应器对城市生活垃圾焚烧厂产生的垃圾沥滤液进行处理。实验结果表明:中温条件下,当COD浓度为55 000 mg/L左右,有机容积负荷(OLR)为22.8 kg COD/(m3.d)时,EGSB对垃圾沥滤液具有较好的的处理效果,COD去除率可达94.2%。当进水COD为72 000 mg/L左右时,为保证反应器的稳定运行,OLR应降低至18.2 kg COD/(m3.d),此时COD去除率可以达到88%左右,出水COD平均为9 103 mg/L。垃圾沥滤液和EGSB处理出水均以小分子量有机物为主,其中<4 kDa的有机物分别占76.5%和74.4%。EGSB对整个分子量区间的溶解性有机物都有较好的处理效果,其中对大分子有机物的处理效率相对更高。  相似文献   

16.
Iron electrodes were used for electrocoagulation (EC) treatment of wastewater from a dairy plant. Electrolysis time, pH, current density and distance between electrodes were considered to assess the removal efficiency of chemical oxygen demand (COD), total solids (TS) and their fractions and turbidity. Samples were collected from the effluent of a dairy plant using a sampling methodology proportional to the flow. The treatments were applied according to design factorial of half fraction with two levels of treatments and three repetitions at the central point. The optimization of parameters for treating dairy industry effluent by electrocoagulation using iron electrodes showed that electric current application for 15 minutes, an initial sample pH close to neutral (pH 7.0) and a current density of 50 A (.)(m-2) resulted in a significant reduction in COD by 58 %; removal of turbidity, suspended solids and volatile suspended solids by 95 %; and a final treated effluent pH of approximately 9.5. Negative consequences of the type of electrode used were the emergence of an undesirable color and an increase in the proportion of dissolved solids in the treated effluent.  相似文献   

17.
提出以二级矿化垃圾床为预处理单元,串联三维电极/电Fenton处理老龄垃圾渗滤液的组合工艺。矿化垃圾床处理后渗滤液中COD、氨氮、总磷、色度的去除率分别为80.55%、88.47%、98.32%和87.53%。通过单因素实验和正交实验,确定了三维电极/电Fenton法最佳工艺条件。经该组合工艺后,渗滤液中COD、氨氮、总磷和色度的最高去除率分别可达97.08%、95.24%、99.55%和96.92%,其中COD、总磷、色度这3个指标低于《生活垃圾填埋场污染控制标准》(GB16889.2008)表2规定的排放标准,为该组合工艺在实际中的应用提供重要理论依据。  相似文献   

18.
通过厌氧折流板反应器(ABR)处理硫酸盐有机废水的实验数据对BP神经网络进行训练,建立了ABR处理硫酸盐有机废水的BPNN模型,通过测试对比,找出了较优训练函数为traingda,较优训练次数为1 900.利用分割连接权值法(PCW)对影响出水SO42-和COD的主要因素进行分析,结果显示进水COD、SO42-、pH、COD/SO42-和HRT对出水SO42-和COD均产生一定影响,其中进水pH对出水SO42-和COD的影响最大,相对重要性(RI)指数分别为30.79%和23.44%;并通过样本试验数据分别建立了对SO42-和COD去除率的限制因子仿真模型,为预测硫酸盐有机废水的厌氧处理过程提供指导.  相似文献   

19.
The nitrogen-removal performances of three full-scale piggery wastewater treatment plants, with different organic and nitrogen loads, at the capacity ranges of 95 to 130 m3/d, were compared in this study. Plants 1 and 2 can be characterized as the modification of anoxic-aerobic operating systems, while an anaerobic and anoxic-aerobic system was used in plant 3. The influent piggery wastewater concentration for plant 1 was relatively lower, but with higher organic and nitrogen loads, resulting in higher chemical oxygen demand (COD) and ammonium-nitrogen in effluent. Plant 2 was operated with strong piggery wastewater, resulting in a higher operating temperature. The high temperature could inhibit the nitrifying activity in plant 2. Although plant 3 was operated with a higher influent total COD-to-total Kjeldahl nitrogen ratio (TCOD:TKN), an additional external carbon source was required to polish the final effluent to remove nitrogen. Influent COD in plant 3 was used in the anaerobic-anoxic reactor for both methane (CH4) production and denitrification. Based on various mass balances, including caloric, COD, and alkalinity, the key elements for the successful nitrogen removal from the piggery waste were reactor temperature (less than 35degrees C), influent TCOD:TKN (greater than 6), and alkalinity-to-TKN ratio (greater than 3).  相似文献   

20.
竹丝生物膜法和生态床组合工艺废水处理的试验研究   总被引:1,自引:0,他引:1  
研究了竹丝生物膜法和生态床组合工艺处理模拟废水,讨论了该组合工艺对模拟废水中COD、氨氮和浊度的去除效果,着重讨论了生态床处理效果的影响因子。试验结果表明,竹丝生物膜法能很好地去除COD、氨氮和浊度等,在水温为9.0~10.5℃、水力停留时间为5.0h、进水COD为98.78~222.69mg/L、氨氮为5.46~12.97mg/L、浊度为26.42~59.84NTU时,出水COD为11.53~20.38mg/L,氨氮为0.42~0.86mg/L,浊度为12.38~17.30NTU。竹丝生物膜法出水再经过简易的生态床工艺,生态床出水COD为9.59~18.84mg/L,氨氮为0.43~0.90mg/L,浊度为6.77~14.15NTU;在此过程中发现,生态床中的鱼类对浊度和COD的去除均有明显效果,而光合作用对生态床COD的去除有促进作用,但是生态床对氨氮浓度却有升高作用。  相似文献   