首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Etoposide susceptibility to microbiological breakdown was studied in a batch biotransformation system, in the presence or absence of artificial wastewater containing nutrients, salts and activated sludge at two concentration levels. The primary focus of the present study was to study etoposide transformation products by ultra-high performance liquid chromatography coupled to high-resolution hybrid quadrupole-Orbitrap tandem mass spectrometry (MS/MS). Data-dependent experiments combining full-scan MS data with product ion spectra were acquired to identify the molecular ions of etoposide transformation products, to propose the molecular formulae and to elucidate their chemical structures. Due to the complexity of the matrix, visual inspection of the chromatograms showed no clear differences between the controls and the treated samples. Therefore, the software package MZmine was used to facilitate the identification of the transformation products and speed up the data analysis. In total, we propose five transformation products; among them, four are described as etoposide transformation products for the first time. Even though the chemical structures of these new compounds cannot be confirmed due to the lack of standards, their molecular formulae can be used to target them in monitoring studies.  相似文献   

2.
An analytical methodology using Automatic Thermal Desorption (ATD) and GC/MS was developed for the determination of the pesticides alachlor, atrazine, captan, formothion, lindane and phosalone in atmospheric samples. This methodology was developed to evaluate the atmospheric contamination by pesticides during treatments and by post-application. Atmospheric samples were collected by using (4 i.d. x 89 mm) stainless steel sampling tubes containing 125 mg of adsorbents at a flow rate of 80 ml min-1. Different types of adsorbents were tested for their ability to efficiently trap pesticides under study: Tenax TA, Carbopack Y, Carbopack B, Carbotrap, Carboxen, Chromosorb 106 and XAD-4. Results of experiment show that Tenax gives the better results for all the pesticides used but the use of the thermal-desorption method, especially for pesticides with low volatility and/or poor thermal stability presents some difficulties. This method was validated by the analysis of the contamination of atmosphere, through volatilization by post-application processes, of atrazine in a parcel of 1 ha.  相似文献   

3.
A solid-phase microextraction -- coupled to a gas chromatography -- ion trap tandem mass spectrometry (SPME-GC-MS/MS) method was developed for the quantitative determination in rainwater of 8 pesticides amongst the most used in France and 3 triazines metabolites. The main factors affecting the SPME process were studied. Using a 3 mL sample, the method developed showed good linearity for concentrations ranging from 0.05 to 50 microgL(-1) with correlation coefficients between 0.997 and 0.9999 and relative standard deviations (% RSD) below 14%. The study of matrix effects showed that rainwater was too diluted to have any significant influence on the extraction efficiency. To validate the method, a field campaign was carried out on the rain events, which occurred in Strasbourg during a one-year period. The rain concentrations showed patterns of high pesticide concentrations during spring months, which were correlated to the spraying periods of most of these substances.  相似文献   

4.
Kemmochi Y  Tsutsumi K 《Chemosphere》2001,43(4-7):433-437
A rapid screening method for the polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDF) in fly ash has been developed. The screening is done in two steps: (a) the extraction by the accelerated solvent extraction and (b) the quantitative measurement by ion trap tandem mass spectrometer (MS/MS). Anhydrous sodium sulfate was added to the fly ash containing activated carbon in order to increase the extraction efficiency. The selectivity of the ion trap MS/MS was confirmed with 13C-labelled internal standard. Then the results of the screening method were compared with those obtained by the conventional analytical method using high-resolution mass spectrometer (HRMS).  相似文献   

5.
A new analytical method has been developed for the quantification of 59 different persistent organohalogen compounds, such as polybrominated diphenyl ethers (PBDEs), polychlorinated naphthalenes (PCNs), polychlorinated biphenyls (PCBs), PCB metabolites, organochlorine pesticides (OCPs) in biological organ tissues. The optimum extraction and cleanup procedures were examined using accelerated solvent extraction (ASE), automated gel permeation chromatography (GPC) on Biobeads S-X3 and automated solid phase extraction (SPE) on silica-gel. The target compounds were divided into two fractions, non-polar compounds and more polar compounds, which in the latter fraction was subsequently methylated using diazomethane. Detection can be achieved by GC/MS in negative chemical ionization (NCI) mode. The average recoveries of the compounds spiked in swine liver, heart, kidney, and cattle adipose tissues were considered satisfactory, and it was confirmed that the method could be used in routine analysis.  相似文献   

6.
The present work describes the application of an analytical procedure, utilizing ultra performance liquid chromatography (UPLC) coupled with mass spectrometry instrumentation, for the determination of 253 multiclass pesticides, classified in six different groups. Solid phase extraction was applied for the isolation and pre-concentration of target compounds in water samples. Surface waters of the lakes located in Northern Greece (Volvi, Doirani, and Kerkini), were collected in two time periods (fall/winter 2010 and spring/summer 2011) and analyzed, applying the developed analytical methods. Spatial distribution of detected pesticides was visualized using interpolation methods and geographical information systems (GIS). Pesticides with maximum concentrations were amitrole, propoxur, simazine, chlorpyrifos, carbendazim, triazophos, disulfoton-sulfone, pyridaben, sebuthylazine, terbuthylazine, atrazine, atrazine-desethyl, bensulfuron-methyl, metobromuron, metribuzin, rotenone, pyriproxyfen, and rimsulfuron. In Lake Kerkini, mainly carbamates and triazines were determined at elevated concentrations, near the coastal point of the NW side of the lake. Seasonal variations were strong among the applied pesticide classes and determined concentrations, indicating the contribution of pesticide application patterns and rainfall. Lake Doirani exhibited organophosphate pesticides at higher concentrations mainly at coastal points, while triazines emerged as the main pollutant during spring sampling. Lake Volvi exhibited the highest pesticide concentrations, mostly triazines and ureas at the central part of the lake. The occurrence of extreme values and nonconstant seasonal variations indicated that the concentrations were increased disproportionately during the second sampling, as a result of the varying contribution of pollution sources right after the application period. In all cases, the total concentration of pesticides increased during the second sampling period.  相似文献   

7.
Ma WT  Fu KK  Cai Z  Jiang GB 《Chemosphere》2003,52(9):1627-1632
The excess use of triazine herbicides in agriculture causes severe contamination to the environment especially for ground water. Gas chromatography coupled with mass spectrometry (GC/MS) was used to analyze simazine, atrazine (ATR), cyanazine, as well as the degradation products of ATR such as deethylatrazine and deisopropylatrazine in environmental water samples. These compounds were baseline separated by the established GC method. The water samples were pre-concentrated by solid-phase-extraction (SPE) and analyzed by ion trap MS at sub- to low-ppt levels. Recovery of ATR by the SPE pre-concentration using a C18 cartridge was determined as 90.5 +/- 3.5%. Detection limit of the method using selected ion monitoring technique for ATR was 1.7 ppt when one liter water was analyzed. The relative analytical error for ATR fortified water samples at 200 ppt was -12.5% (n=12) with triple analysis and the relative standard deviation was 3.2%. Trace levels of ATR at 3.9 and 9.7 ppt were determined in water samples collected from a reservoir and a river in Hong Kong.  相似文献   

8.
Kemmochi Y  Tsutsumi K  Futami K 《Chemosphere》2002,46(9-10):1451-1455
Commercial ion trap mass spectrometer provides easy-to-operate MS/MS analysis for the determination of PCDD/PCDF. The limit of quantification is appropriately low (0.2 pg for 23478-P5CDF) because all the stages are performed in the trap and sample losses associated with the ion transportation are minimized. However, if excessive ions are injected into the trap, its electrical fields are distorted and an overall reduction in performance arises. Ionization condition is an important parameter as it affects the amount of the total ions produced. If the amount of interfering compounds are negligible, such as standard solution or cleaned-up sample, lower ionization condition (e.g. electron energy: 30 eV, emission current (EC): 150 μA) is preferable. On the contrary, in case excessive interfering ions are coexisting with PCDD/PCDF, such as crude extract or semi-cleaned-up sample, the ionization condition should be high (e.g. electron energy: 90 eV, EC: 350 μA) for the reproductive quantification.  相似文献   

9.
A growing number of studies now indicate that perfluorinated compounds (PFCs) are globally distributed in the environment. Their widespread distribution and presence in remote locations has led to questions about the importance of atmospheric and oceanic transport. Describing their distribution in surface soils is also an essential but neglected element in developing a comprehensive understanding of their occurrence in the environment. Soils are the critical link between global atmospheric and hydrologic processes where both local and distant contaminants can accumulate and be released into aquatic and terrestrial communities. Because PFC concentrations in soils will influence ground and surface water, wildlife, and crops, methods to accurately measure PFCs in soil are clearly needed. To help answer this need, we developed a method for the analysis of nine perfluorinated carboxylic acids and four perfluorinated sulfonic acids in soil. Samples from six nations (n = 10 per nation) were analyzed by LC-MS/MS to demonstrate the method performance parameters and to make preliminary observations about the occurrence of the PFCs in soils in different parts of the world. The resulting method shows acceptable performance characteristics for the target compounds in most soils while documenting the widespread occurrence of PFCs in surface soils.  相似文献   

10.
A multiresidue analytical method was developed for the determination of 9 endocrine disrupting chemicals (EDCs) and 19 pharmaceuticals and personal care products (PPCPs) including acidic and neutral pharmaceuticals in water and soil samples using rapid resolution liquid chromatography-tandem mass spectrometry (RRLC-MS/MS). Solid phase extraction (SPE), and ultrasonic extraction combined with silica gel purification were applied as pretreatment methods for water and soil samples, respectively. The extracts of the EDCs and PPCPs in water and soil samples were then analyzed by RRLC-MS/MS in electrospray ionization (ESI) mode in three independent runs. The chromatographic mobile phases consisted of Milli-Q water and acetonitrile for EDCs and neutral pharmaceuticals, and Milli-Q water containing 0.01 % acetic acid (v/v) and acetonitrile: methanol (1:1, v/v) for acidic pharmaceuticals at a flow rate of 0.3 mL/min. Most of the target compounds exhibited signal suppression due to matrix effects. Measures taken to reduce matrix effects included use of isotope-labeled internal standards, and application of matrix-match calibration curves in the RRLC-MS/MS analyses. The limits of quantitation ranged between 0.15 and 14.08 ng/L for water samples and between 0.06 and 10.64 ng/g for solid samples. The recoveries for the target analytes ranged from 62 to 208 % in water samples and 43 to 177 % in solid samples, with majority of the target compounds having recoveries ranging between 70–120 %. Precision, expressed as the relative standard deviation (RSD), was obtained less than 7.6 and 20.5 % for repeatability and reproducibility, respectively. The established method was successfully applied to the water and soil samples from four irrigated plots in Guangzhou. Six compounds namely bisphenol-A, 4-nonylphenol, triclosan, triclocarban, salicylic acid and clofibric acid were detected in the soils.  相似文献   

11.
Ion composition elucidation (ICE) often leads to identification of compounds and provides high-quality evidence for tracking compounds to their sources. Mass spectra for most organic compounds are not found in mass spectral libraries used to tentatively identify analytes. In addition, multiple matches are common. Ion Composition Elucidation provides the numbers of atoms of each element in the ions in the mass spectrum, greatly limiting the number of possible compounds that could produce the mass spectrum. Review of chemical and commercial literature then limits the number of possible compounds to one or a few that can be purchased to confirm tentative compound identifications by comparison of mass spectra and chromatographic retention times. Ion composition elucidation is conceptually simple relative to other analytical techniques and more easily explained to a judge or jury. It is based on sums of the exact masses of atoms and their isotopic abundances. Several applications of ICE are demonstrated for ultra-trace-level compounds in an extract of the e.uent from a tertiary sewage treatment plant including: (1) measurement of five values to determine an ion's composition and to generate evidence for the compound's identity, (2) rejection of incorrect library matches, (3) rapid screening for a target compound in an extract, and (4) a strategy for tracking unidentified compounds to their sources.  相似文献   

12.
Ion composition elucidation (ICE) often leads to identification of compounds and provides high-quality evidence for tracking compounds to their sources. Mass spectra for most organic compounds are not found in mass spectral libraries used to tentatively identify analytes. In addition, multiple matches are common. Ion Composition Elucidation provides the numbers of atoms of each element in the ions in the mass spectrum, greatly limiting the number of possible compounds that could produce the mass spectrum. Review of chemical and commercial literature then limits the number of possible compounds to one or a few that can be purchased to confirm tentative compound identifications by comparison of mass spectra and chromatographic retention times. Ion composition elucidation is conceptually simple relative to other analytical techniques and more easily explained to a judge or jury. It is based on sums of the exact masses of atoms and their isotopic abundances. Several applications of ICE are demonstrated for ultra-trace-level compounds in an extract of the effluent from a tertiary sewage treatment plant including: (1) measurement of five values to determine an ion’s composition and to generate evidence for the compound’s identity, (2) rejection of incorrect library matches, (3) rapid screening for a target compound in an extract, and (4) a strategy for tracking unidentified compounds to their sources.  相似文献   

13.
Volatile organic compounds (VOCs) are major group of air pollutants which play critical role in atmospheric chemistry. It contributes to toxic oxidants which are harmful to ecosystem human health and atmosphere. Data on levels of VOCs in developing countries is lacking. In India information at target VOCs as defined in USEPA compendium method TO-14 is almost totally lacking. The present work deals with estimation of target VOCs at 15 locations in five categories namely residential, industrial, commercial, traffic intersections and petrol refueling stations in Delhi, the capital of India. The monitoring was carried out during peak hours in morning and evening each month for a year in 2001. Ambient air was adsorbed on adsorbent tubes, thermally desorbed and analyzed on GC–MS. The results show that levels of VOCs are high and stress the need for regular monitoring programme of VOCs in urban environment.  相似文献   

14.
Collection of atmospheric H2O2 was performed by a cold trap method using dry ice-acetone as the refrigerant. The air was drawn by a pump into a glass gas trap immersed in the dry ice-acetone slush in a dewar flask at a flow rate of 2.5 l min-1 for approximately 2 h. Collection efficiency was > 99% and negligible interferences by O3, SO2 or organic matter with the collected H2O2 in the trap were observed. This method was compared with the air impinger bubbling method which has been previously described (Kok et al., 1978a, b, Envir. Sci. Technol. 12, 1072-1080). The measured total peroxide (H2O2 + organic peroxide) values in a series of aim samples collected by the impinger bubbling method (0.06-3.7 ppb) were always higher than those obtained by the cold trap method (0.02-1.2 ppb). Laboratory experiments suggest that the difference in values between the two methods probably results from the aqueous phase generation of H2O2 and organic peroxide in the impinger solution by a reaction of atmospheric O3 with olefinic and aromatic compounds. If these O3-organic compound reactions which occur in the impinger also occur in aqueous droplets in the atmosphere, the process could be very important for aqueous phase generation of H2O2 in clouds and rainwater.  相似文献   

15.
利用吹扫捕集-GC/MS法对引起南宁市竹排冲河道水体黑臭的嗅味物质进行检测分析。结果表明,导致竹排冲水体黑臭的嗅味物质主要为苯系物、硫类化合物和氯苯类化合物,其中甲硫醚(相对含量1.70%)、二甲基二硫醚(相对含量3.19%)、甲基丙基二硫醚(相对含量6.11%)等挥发性有机物为竹排冲水体中的主要致嗅物质,是竹排冲水体嗅味产生的主要原因。  相似文献   

16.
Emissions of volatile organic compounds (VOCs) from different thermoplastic polymers used in electrotechnical applications were investigated using a purge and trap procedure that involved adsorption on Tenax GR. Results were compared to those for an operating TV set monitored in a test chamber. The analyses were in both cases carried out using thermodesorption gas chromatography with mass spectrometric detection (TDS-GC/MS). Substances identified were monomers, volatile additives, or related compounds. Special attention was given to the detection of halogenated compounds. Their origin was studied using reference samples and synthetic standards.  相似文献   

17.
This work describes the development, optimization and validation of an analytical method for the simultaneous detection and identification of 74 pharmaceutically active compounds (PhACs), from various therapeutic groups, in both environmental (ground and surface water) and wastewaters (WW). The method is based on the simultaneous extraction of all target compounds by solid phase extraction (SPE), using a hydrophilic-lipophilic balanced polymer followed by ultra high performance liquid chromatography (UHPLC) tandem mass spectrometry (MS/MS). Two selected reaction monitoring (SRM) transitions have been monitored per compound in order to fulfil the EC guidelines, as well as to ensure an accurate identification of target compounds in the samples. Quantification is performed by internal standard approach, applying 24 specific isotopically labeled compounds. The main advantages of the developed method, besides the selectivity and reliability of the results, is its high throughput. All compounds are extracted in a single step and the instrumental analysis lasts 5 min (NI mode) + 8 min (PI mode), allowing fast throughput of samples. The limits of detection range from 0.01 to 50 ng L−1, depending on the matrix, for most of the compounds. Finally, the method developed has been applied to the analysis of pharmaceuticals in the Ebro river basin (NE Spain).  相似文献   

18.
A salt-wedge stratified microcosm, spiked with 31 target analytes, including PCBs, organochlorine and organophosphorous pesticides, triazines, organophosphate flame retardants and caffeine (an urban wastewater molecular marker), was setup. Compound behaviour was monitored during a four week period, by sampling at six different levels of the water column, in order to understand the transport and loss processes of the different classes of chemical substances. Compound transport from one water body to the other has been positively correlated with diffusion via their molar volume. Target analytes loss has been positively correlated with evaporation via their K(H) and with degradation via their halve-lives. From these two processes, evaporation was found to be predominant using a multiparametric regression.  相似文献   

19.
Chlorofluorocarbons and their replacement compounds are anthropogenic compounds of great environmental concern. For this reason monitoring their atmospheric mixing ratios on a worldwide scale is recommended. An analytical methodology for the simultaneous determination of selected chlorofluorocarbons and their replacement compounds has recently been developed. This methodology was applied in the analysis of actual air samples collected in remote and semi-remote areas located in the Northern and Southern Hemispheres. The concentration levels measured in the air samples collected in the two hemispheres are reported.  相似文献   

20.
Salthammer T  Mentese S 《Chemosphere》2008,73(8):1351-1356
The level of carbonyl compounds in indoor air is crucial due to possible health effects and the high prevalence of their potential sources. Therefore, selecting a convenient and rapid analytical technique for the reliable detection of carbonyl compound concentrations is important. The acetyl acetone (acac) method is a widely used standard procedure for detecting gaseous formaldehyde. For measuring formaldehyde along with other carbonyl compounds, the DNPH-method is commonly applied. The recommended procedure for measuring volatile organic compounds (VOCs) is sampling on Tenax TA, followed by thermal desorption and GC/MS analysis. In this study, different analytical techniques for the quantification of formaldehyde, pentanal, and hexanal are critically compared. It was found that the acac- and DNPH-method are in very good agreement for formaldehyde. In contrast, the DNPH-method significantly underestimates indoor air concentrations of the higher aldehydes in comparison to sampling on Tenax TA, although both methods are strongly correlated. The reported results are part of the EURIMA-WKI study on levels of indoor air pollutants resulting from construction, building materials and interior decoration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号