首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Wang LC  Lee WJ  Tsai PJ  Lee WS  Chang-Chien GP 《Chemosphere》2003,50(9):1123-1129
This study investigated four sinter plants, classified into two categories--with selective catalytic reduction (SCR) (S1, S2 and S3) and without SCR (S4) as its air pollution control device. Polychlorinated dibenzofurans (PCDFs) are dominant in the stack flue gases of sinter plants with and without SCR. The polychlorinated dibenzofurans/polychlorinated dibenzo-p-dioxins (PCDFs/PCDDs) ratio exceeds 1 extremely. The degree of chlorination of the sinter plant without SCR is towards hepta and hexa congeners while that of the sinter plant with SCR is towards penta and hexa congeners. PCDD/Fs are indeed decomposed (75.5% and 69% on ng and ng TEQ bases, respectively) and not only reduced in degree of chlorination. The overall concentration in the stack flue gas of sinter plants with SCR (7.97-14.1 ng/Nm(3); 0.995-2.06 ng TEQ/Nm(3)) is lower than that of the sinter plant without SCR (28.9 ng/Nm(3); 3.10 ng TEQ/Nm(3)). In Taiwan, based on the emission factors of 0.970 microg TEQ/ton-feedstock (sinter plants with SCR) and 3.13 microg TEQ/ton-feedstock (sinter plant without SCR), the annual PCDD/F emission of 44.7 g TEQ/year from sinter plants is 60 and 121 times higher than those from municipal solid waste incinerators (0.750 g TEQ/year) and MWIs (0.369 g TEQ/year). These results show that sinter plants have become the dominating PCDD/F emission source since tighter emission limits have been applied to incinerators.  相似文献   

2.
Air pollution control devices (APCDs) are not compulsory for medical waste incinerators (MWIs) in developing countries. In South Africa, combustion gases are usually vented directly to the atmosphere at temperatures greater than the formation temperature of dioxin. The possibility of dioxin formation outside the incinerator stack has been hypothesized. A plume model has been developed and tested in the wind tunnel with a scale model of an incinerator stack. The plume temperature and trajectory predictions of the plume model were verified within a +/- 3% experimental accuracy. Using South African data, the plume model predicts that the residence time of gases in the temperature range of 150-450 degrees C in a plume is 1.3 sec on average for 5% of a year (18 days) at meteorological conditions resulting in wind speeds of less than 1 m/sec. Two published dioxin formation models were used to assess the probability of dioxin formation in the plume. The formation models predict that the average polychlorinated dibenzodioxins/furans (PCDD/Fs) formed in the plume will exceed the stack emission regulations in South Africa of 0.2 ng/Nm3 toxic equivalent quotient (TEQ) by between 2 and 40 times. The calculated concentrations do not include additional gaseous PCDD/F compounds that may be formed at high-temperature post-combustion zones through pyrosynthesis mechanisms.  相似文献   

3.
Abad E  Caixach J  Rivera J 《Chemosphere》2003,50(9):1175-1182
This study presents the results of a dioxin abatement programme undertaken in the municipal waste incineration plant of Montcada i Reixac (Barcelona, Spain) after the replacement of an obsolete air cleaning device by a new flue gas treatment system. A number of sampling campaigns were conducted with the aim of characterising stack gas emission levels of polychlorinated dibenzo-p-dioxins (PCDDs)/polychlorinated dibenzofurans (PCDFs) and to evaluate initial specifications of dioxin stack gas emission values below 0.1 ng I-TEQ/Nm(3). Preliminary results revealed levels between 44 and 111 ng I-TEQ/Nm(3) when the gas-cleaning system consisted only of an old electrostatic precipitator (ESP). Decreased levels around 15 ng I-TEQ/Nm(3) were observed when the semi-dry scrubber began to operate and the ESP was switched off. Again, remarkable dioxin removal was observed after the installation of the fabric filter and levels around 0.3-0.4 ng I-TEQ/Nm(3) were soon achieved. Nevertheless, the limit of 0.1 ng I-TEQ/Nm(3) was reached by additional injection of activated carbon which helped to lower PCDD/PCDF levels to around 0.036 ng I-TEQ/Nm(3). The results also demonstrated a significant change in the dioxin distribution present in combustion-derived materials (stack gas emission, bottom ash and solid waste from gas treatment). The major dioxin fraction was found in gaseous matrices before the flue gas control system was upgraded. After this step, the major dioxin fraction content was observed in solid waste from gas treatment.  相似文献   

4.
Noma Y  Yamamoto T  Giraud R  Sakai S 《Chemosphere》2006,62(7):1183-1195
In the first known study to characterize the emissions of polychlorinated naphthalenes (PCNs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (dl-PCBs) from the thermal treatment of wastes containing PCNs, the formation and decomposition behavior of these pollutants was investigated both at laboratory scale and at plant scale. Exhaust gas measurements from laboratory-scale combustion of rubber belts containing PCNs (FB belts) were used as the basis for calculations predicting that the incremental dioxin toxic equivalency (TEQ) emissions from municipal solid waste (MSW) incinerators would be less than 0.1 ng/m3 N. In order to directly examine co-incineration of FB belts with MSW and to address potential differences between the laboratory experiment and full-scale MSW incinerators, experiments were conducted using a larger scale thermal treatment test facility with sampling and analysis at several points in the thermal treatment process. Congener specific analysis of PCNs clearly showed that both destruction and synthesis simultaneously occurred during combustion in the kiln. Most of the PCNs were destroyed by secondary combustion, and almost all PCNs were removed after flue gas treatment. Almost all PCDDs/DFs were synthesized as by-products of kiln combustion, most of them were destroyed by the secondary combustion, and almost all dioxins (PCDDs/DFs and dl-PCBs) were removed after flue gas treatment. The TEQ emission levels were less than 0.1 ng/m3 N for all plant-scale tests, and differences in TEQ emission levels were very small. Adding wastes containing PCNs to MSW will not influence thermal treatment emissions to the environment from modern solid waste incinerators.  相似文献   

5.
Ogura I  Masunaga S  Nakanishi J 《Chemosphere》2001,44(6):1473-1487
The atmospheric bulk (dry and wet) deposition of dioxins was investigated at four locations (Tokyo, Yokohama, Tsukuba, and Tanzawa) in the Kanto region (in Japan) over one year using a stainless-steel pot. Annual average polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDD/PCDF) deposition fluxes were estimated to be from 450 to 1300 ng/m2/yr, and the annual average TEQ fluxes from 5.7 to 17 ng-TEQ/m2/yr at the four locations. The PCDD/PCDF deposition flux was higher in winter than in summer. The deposition flux could be related to ambient temperature, particularly for less chlorinated PCDDs/PCDFs, while the deposition flux is not necessarily related to the amount of precipitation. The PCDD/PCDF deposition flux increased as the particle deposition flux increased, for the winter samples. Based on the ratio of the PCDD/PCDF deposition fluxes to the particle deposition fluxes, the contribution of the reentrainment of soil particles to the TEQ of PCDD/PCDF deposition was considered to be negligible in this region. Based on the air concentrations monitored near our deposition sampling points by the municipalities, the ratio of the annual deposition flux to the annual average air concentration was roughly estimated to be 0.082 cm/s. The range of deposition flux in the Kanto region was estimated to be from 1.5 to 31 (median: 9.8) ng-TEQ/m2/yr based on the range of air concentration data measured by the municipalities. The total annual deposition flux in the entire Kanto region was estimated to range from 50 to 900 g-TEQ/yr (median 320 g-TEQ/yr). This estimated flux was of the same order as the sum of estimated emissions from municipal solid waste incinerators and industrial waste incinerators in the Kanto region. The contributions of dioxin-like PCBs in Yokohama, Tsukuba, and Tanzawa depositions were less than 10% of the total TEQ; however, in Tokyo it was almost equal to or more than 50%.  相似文献   

6.
Medium- and low-volatile organic chlorine (M/LVOCl) and PCDD/Fs in flue gas from various municipal waste incinerators (MWIs) were monitored. The sample for M/LVOCl was collected in an adsorption tube which was thermally desorbed and the amount of chlorine was measured by atomic emission spectrometry (AES) detection using radiofrequency helium plasma. The helium plasma excited chlorine having an optical emission line of 837.6 nm was monitored. The MVOCl and LVOCl were organic chlorine groups whose boiling points (bp) ranged from 70-120 degrees C and 170-270 degrees C, respectively. The compounds having bp 120-170 degrees C were distributed in two tubes. LVOCl correlated well with PCDD/Fs (ng/Nm3, r=0.81) in a wide range of 0.01-100 ng/Nm3 of PCDD/Fs, while the correlation of LVOCl vs. TEQ was less related (r=0.69). These results agreed with the fact that LVOCl monitored the amount of organic chlorine without molecular structure information, which is critical to toxicity. Since the bp of LVOCl was not identical with that of PCDD/Fs, the regression was effected by the conditions of the gas treatment devices. Because most data of 2001 were collected just after the installation of PCDD/Fs in MWIs, the regression of 2001 was slightly different from that of 2002-2003. Eliminating these initial unsteady data, the regression of LVOCl vs. PCDD/Fs became better, giving r= 0.86. Besides having PCDD/Fs as surrogates, M/LVOCl is valuable as a versatile element-selective organic chlorine monitor to improve thermal process control.  相似文献   

7.
Phoenix Services, Inc., owns and operates the Baltimore Regional Medical Waste Incinerator in Baltimore, MD. New regulations for dioxins and furans imposed a limit that was considerably below historical emission levels. To determine a method to comply with the new dioxin/furan regulations, Phoenix Services performed trials with powdered activated carbon (PAC). Although the results with carbon were acceptable, Phoenix Services decided to replace their woven fiberglass filter bags with catalytic filters that simultaneously destroy dioxins and furans and collect particulate matter (PM). The catalytic filter system offered several advantages to Phoenix Services, including destruction of dioxins and furans instead of adsorption on carbon. The catalytic filters also offered a passive solution that did not require new carbon injection equipment. In January 2000, a campaign to measure dioxins/furans and PM was undertaken. The measurements allowed the catalytic filter system to be evaluated. Some of the key findings of this investigation are The dioxin/furan emission was less than 0.1 ng toxicity equivalents (TEQ)/Nm3 at 11% O2. This concentration is approximately 2 orders of magnitude less than historical averages and it is well below the new regulatory limits, for both existing and new sources of this type; the amount of dioxin/furans destroyed by the catalytic filters was approximately 1.73 ng TEQ/Nm3 at 11% O2; and the particulate emission was 12-17 times less than the regulatory limit.  相似文献   

8.
Over 200 samples of cow's milk have been analysed for dioxins in a survey on the occurrence of dioxins in milk from the vicinity of municipal waste incinerators (MSWs) and other potential dioxin sources in The Netherlands. Levels in milk were found to vary considerably with time, depending on emission rates, the direction and distance to the source and the feeding and housing of cows. Highest levels of up to 13.5 pg TEQ/g of milk fat were found in the Lickebaert area and Zaandam near two incinerators with highest emission rates. The background level ranged between 0.7 and 2.5 pg TEQ/g of milk fat. Levels in winter were comparable to those found in summer and, in some areas, even higher, when cows were fed with hay and silage harvested on the same farm. After the closure of the MSW in Zaandam, cow's milk from neighbouring farms showed a significant decrease in dioxin levels to below the critical limit of 6 pg TEQ/g of milk fat. Dioxin levels in the vicinity of a metal reclamation plant were comparable to those in milk from the vicinity of a MSW with moderate emissions. Differences were observed in the ratio PCDF/PCDD, which was higher in milk near the metal reclamation plant. Principal component analysis has been applied on a large data set of patterns of the 2,3,7,8-chlorine substituted PCDDs and PCDFs in cow's milk. This technique has proved to be useful for distinguishing and identification of sources on the basis of the isomer pattern in milk.  相似文献   

9.
As one of the countries with large amounts of dioxin releases, the control of dioxins is a major challenge for China. Municipal solid waste (MSW) incineration should be considered a high priority source of dioxin emissions because it is playing an increasingly more important role in waste management. MSW incineration in China has much higher emission rates of dioxins than in the developed countries, partially resulting from the gaps in the technologies of incineration and flue gas cleaning. Moreover, the current management policies and practices also contribute significantly to the problem. We recommend lowering dioxin emission standard, strengthening fly ash management, and improving regulation enforcement to reduce dioxin releases into the environment from MSW incineration. We also propose that alternative strategies should be considered on dioxin control and call for an expansion of economic instruments in waste management to reduce waste generation and thus the need for incineration.  相似文献   

10.
Anderson DR  Fisher R 《Chemosphere》2002,46(3):371-381
Several countries have compiled national inventories of dioxin (polychlorinated dibenzo-p-dioxin [PCDD] and polychlorinated dibenzofuran [PCDF]) releases that detail annual mass emission estimates for regulated sources. High temperature processes, such as commercial waste incineration and iron ore sintering used in the production of iron and steel, have been identified as point sources of dioxins. Other important releases of dioxins are from various diffuse sources such as bonfire burning and domestic heating. The PCDD/F inventory for emissions to air in the UK has decreased significantly from 1995 to 1998 because of reduced emissions from waste incinerators which now generally operate at waste gas stack emissions of 1 ng I-TEQ/Nm3 or below. The iron ore sintering process is the only noteworthy source of PCDD/Fs at integrated iron and steelworks operated by Corus (formerly British Steel plc) in the UK. The mean waste gas stack PCDD/F concentration for this process is 1,2 ng I-TEQ/Nm3 based on 94 measurements and it has been estimated that this results in an annual mass release of approximately 38 g I-TEQ per annum. Diffuse sources now form a major contribution to the UK inventory as PCDD/Fs from regulated sources have decreased, for example, the annual celebration of Bonfire Night on 5th November in the UK causes an estimated release of 30 g I-TEQ, similar to that emitted by five sinter plants in the UK.  相似文献   

11.
日本二噁英减排控制的历程、经验与启示   总被引:1,自引:0,他引:1  
二噁英减排控制是《关于持久性有机污染物的斯德哥尔摩公约》的重要任务,是履行公约义务的难点.对日本二噁英减排控制20年来的实践历程进行了回顾和分析,总结出了其协调管理机制设立、法律法规标准建立、监测能力建设以及宣传教育等八个方面的成功经验,对中国二噁英减排控制工作有重要的借鉴意义.  相似文献   

12.
This study investigates the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from four electric arc furnaces (EAFs) and eight secondary aluminum smelters (secondary ALSs) in Taiwan. The mean PCDD/F International-Toxicity Equivalents (I-TEQ) concentrations in the stack gases of these EAFs and secondary ALSs are 0.28 ng I-TEQ/Nm3 (relative standard deviation [RSD]= 100%) and 3.3 ng I-TEQ/Nm3 (RSD = 260%), respectively. The high RSDs, especially for those obtained from secondary ALSs, could be caused by the intrinsic differences in their involved feeding materials, furnace operating conditions, and air pollution control devices. The mean I-TEQ emission factor of PCDD/Fs for EAFs (1.8 microg I-TEQ/tonne-feedstock) is lower than that for secondary ALSs (37 microg I-TEQ/tonne-feedstock). This result might be because the involved furnace temperatures for secondary ALSs (650-750 degrees C) are lower than those for EAFs (1600-1700 degrees C), resulting in the deterioration of the combustion condition, leading to the formation of PCDD/Fs during the industrial process. This study found that the total PCDD/F emissions from EAFs (20 g I-TEQ/yr) and secondary ALSs (18 g I-TEQ/yr) are approximately 27, 53, and approximately 24, 49 times higher than those from municipal solid waste incinerators (MSWIs; 0.74 g I-TEQ/yr) and medical waste incinerators (MWIs; 0.37 g I-TEQ/yr), respectively; while those are 44 and 40% of total PCDD/F emission from sinter plants (45 g I-TEQ/ yr), respectively. Considering a more stringent emission limit has been applied to waste incinerators (0.1 ng I-TEQ/Nm3) in Taiwan lately, the results suggest that the control of the emissions from metallurgical processes has become the most important issue for reducing the total PCDD/F emission from industrial sectors to the ambient environment.  相似文献   

13.
After entry into force of the Stockholm Convention and Aarhus Protocol and in order to implement the upcoming European legal background, the European countries are asked to apply control measures to reduce the release of persistent organic pollutants (POPs) such as dioxins and furans (PCDD/PCDF) and polychlorinated biphenyls as well as to establish POPs release inventories. In this perspective, development of measuring techniques of emissions is a focal issue in acquiring useful information. In this paper, results of various measurement campaigns at different municipal waste incineration (MWI) plants using long-term automated sampling of PCDD/PCDF are presented. The samples collected from both manual and automated campaigns were analyzed following the European Standard EN-1948:2006 by high-resolution gas chromatograph/high-resolution mass spectrometer. Performances of two different commercial systems have been investigated. Anomalous values occurred during one long-term campaign (22.16 pg I-toxic equivalent (TEQ)/Nm(3)), compared to average values (4-5 pg I-TEQ/Nm(3)) of the MWI. At this maximum value, a main occurrence of abnormal and instable operating conditions has been found. Sampling based on long-term basis was found to be more reliable to monitor PCDD/PCDF emissions than occasional short-term sampling. Nevertheless, the results of long-term campaigns demonstrate that emission levels detected in 15-30 days campaigns, when unsteady operating conditions can occur, as start-up and shut down, are not immediately comparable to the typical levels in a 6-8 h, when operating conditions are generally stable. Moreover, there are often differences observed in the congener profiles between short- and long-term campaigns.  相似文献   

14.
Dioxin contents in fly ash from large-scale MSW incinerators in Taiwan   总被引:6,自引:0,他引:6  
In this study, fly ash samples were collected from three municipal waste incinerators (MWI) in Taiwan. These MWIs investigated are equipped with different air pollution control devices (APCDs). Preliminary results indicated that 2,3,7,8-PCDD/Fs homologue patterns of various types of fly ash were quite similar for all three MWIs. Concentrations of higher-chlorinated congeners of PCDDs and PCDFs were remarkably higher than those of lower-chlorinated congeners. In the case of MSW-A, the PCDD/PCDF ratios of ashes were found in the decreasing order for cyclone, boiler and baghouse. The PCDD/PCDF ratios in various types of fly ash of MWI-B was boiler-A < boiler-B < ESP < boiler-C. As for MSW-C, no obvious trend has been observed for PCDD/PCDF ratio. However, the ratio in boiler ash was higher than that in baghouse ash of MWI-A. The dioxin contents in fly ash would increase as the fly ash passed through APCD zones. In other words, the environmental conditions of APCD may actually cause the increase of the dioxin contents in fly ash. The trend for dioxin contents in fly ash collected from three MSW incinerators investigated was MSW-C < MSW-A < MSW-B.  相似文献   

15.
Effect of backyard burning on dioxin deposition and air concentrations   总被引:1,自引:0,他引:1  
Wevers M  De Fré R  Desmedt M 《Chemosphere》2004,54(9):1351-1356
The influence from open burning of garden and household waste on locally measured dioxin deposition and air concentrations was evaluated in three sets of experiments: the combustion of garden waste in barrels and in open fires, and the incineration of household waste in an empty oil drum. Each set was composed of eight individual experiments over 4 h. Deposition gauges were located 20 m NE, SE, SW and NW with respect to the source and on a background location at 400 m SW. Air samples were taken in the plume with a medium volume sampler equipped with a quartz filter and a polyurethane plug. The results illustrate deposition increments in the wind direction at a distance of 20 m from the source of 0.8 pg TEQ/m2 day for garden waste and 2.5 pg TEQ/m2 day for household waste. Concentrations in the plume were increased by 160-580 fg TEQ/m3 over a period of 12 and 31 h respectively. Expressed at a reference CO2 concentration of 9% this corresponds with a range from 0.8 to 3.6 ng TEQ/m3, which is comparable with a poorly controlled MSWI. Emission factors in the order of magnitude of 4.5 ng TEQ/kg combusted garden waste and 35 ng TEQ/kg burned municipal waste were determined.  相似文献   

16.
Ash samples collected from medical, municipal and small-scale domestic incinerators in Japan were tested for dioxin-like activity using bioassay technique (ethoxyresorufin-O-deethylase: EROD assay) and for extractable organohalogens (EOX) using instrumental neutron activation analysis in order to estimate potential toxicity and responsible chemicals in those samples. Crude extracts and fractions cleaned-up for dioxin analysis from the samples were used for the analysis. The ranges of dioxins in the ashes were between 2.23 and 12.29 ng TEQ/g (dry weight). Relative potency ranges estimated by EROD assay in the medical incinerator ashes were 3.8-17.6 times higher than the results of conventional chemical analysis. EOX analysis suggested that ash samples contained plenty of organochlorine compounds apart from chlorinated dioxins. In addition, medical waste incinerator ashes were considered to have relatively higher amount of organoiodine compounds. In the cleaned-up fractions, bioassay potency ranges were lower than those in the crude extracts. However, some samples still exhibited higher potency than expected from chemical analysis. Though some polycyclic aromatic hydrocarbons were found in the fractions, the amounts were relatively low (0.39-10.56 ng/g). The results imply that some bioactive organohalogens that cannot be detected in the conventional chemical analysis might have potential for dioxin-like toxicity, and contribute to higher bioassay activities. The combination of the chemical analysis with the bioassay and EOX provides rough figure of dioxin-like toxicity and suggests types of organohalogen compounds that should be identified as a part of dioxin analysis for control emission from an incineration plant.  相似文献   

17.
Significant dioxin (polychlorinated dibenzo-para-dioxins (PCDDs)/polychlorinated dibenzo-furans (PCDFs)) pollution from a municipal solid waste incinerator was discovered in 1997 in Osaka prefecture/Japan. The cause and mechanism of pollution was identified by a detailed assessment of the environment and incinerator plant. The primary sources of PCDD/PCDF pollution were high dioxin releases from an intermittently operated waste incinerator with PCDD/PCDF emissions of 150 ng-TEQ/Nm3. PCDD/PCDF also accumulated in the wet scrubber system (3,000 μg TEQ/L) by adsorption and water recirculation in the incinerator. Scrubber water was air-cooled with a cooling tower located on the roof of the incinerator. High concentrations of dioxins in the cooling water were released as aerosols into the surrounding and caused heavy soil pollution in the area near the plant. These emissions were considered as the major contamination pathway from the plant. Decontamination and soil remediation in and around the incinerator plant were conducted using a variety of destruction technologies (including incineration, photochemical degradation and GeoMelt technology). Although the soil remediation process was successfully finished in December 2006 about 3 % of the waste still remains. The case demonstrates that releases from incinerators which do not use best available technology or which are not operated according to best environmental practices can contaminate their operators and surrounding land. This significant pollution had a large impact on the Japanese government’s approach toward controlling dioxin pollution. Since this incident, a ministerial conference on dioxins has successfully strengthened control measures.  相似文献   

18.
Chi KH  Chang MB  Kao SJ 《Chemosphere》2007,68(9):1733-1740
Polychlorinated dibenzo-p-dioxin (PCDD), polychlorinated dibenzofuran (PCDF) and polychlorinated biphenyl (PCB) concentrations were analyzed at 1-2cm intervals in a sediment core collected from a reservoir in Northern Taiwan to evaluate the organic pollution history. The highest PCDD/F (14.4ng TEQ/kg d.w.) and PCB (0.261ng TEQ(WHO)/kg d.w.) concentrations were determined at 13-15cm (estimated year: 1992). The ages of the levels of sediment core were estimated from the sedimentation rate. Analysis results demonstrate that the PCDD/F concentration of the sediment core measured in the reservoir reached their peak when the municipal waste incinerators (MWIs) in the area started to operate. Furthermore, the decrease in sediment core PCDD/F concentration is related to the time of enforcement of the PCDD/F emission limit set by the Environmental Protection Administration (EPA) in Taiwan. Significant distribution of OCDD in homologue profiles was noted in archived soil samples in Taiwan in which the major input of PCDD/Fs was thought to be atmospheric. Major PCB congeners found in the sediment core were the major components of the commercial PCB products. Input fluxes of PCDD/Fs (5.75-158ng-I-TEQ/m(2)-yr) and PCBs (0.248-3.71ng TEQ(WHO)/m(2)yr) into the reservoir of interest are also calculated from the concentration and sedimentation rate of the sediment. The results reveal that considerable amounts of PCDD/Fs and PCBs were carried into the reservoir of interest in the flood stage but not during normal stage.  相似文献   

19.
Abad E  Caixach J  Rivera J 《Chemosphere》1999,38(1):109-120
Polychloronaphthalenes (PCN) were identified and quantified in emission samples collected from five different municipal waste incinerators (MWI). Polychlorodibenzo-p-dioxins (PCDD) and polychlorodibenzofurans (PCDF) were also determined to find a possible relationship between these classes of organochlorinated compounds. The analyses of PCDD/PCDF and PCN were carried out by high resolution gas chromatography coupled with high resolution mass spectrometry using a positive electron ionization source and operating in the selected ion monitoring analyzer mode (HRGC-HRMS/EI(+)-SIM). The total levels of PCN varied from 1.08 up to 21.36 ng/Nm3 (mono- to octachlorinated) and 0.33 to 5.72 ng/Nm3 (tetra- to octachlorinated), whereas the levels of PCDD/PCDF ranged between 1.14 and 276.26 ng/Nm3 (0.01 and 5 ng I-TEQ/Nm3), depending on the type of the MWI. These findings do not corroborate a PCN and PCDD/PCDF correlation.  相似文献   

20.
Five fluidized bed incinerators combusting municipal solid waste were assessed for the impact of coplanar PCBs on total TEQ emission. In 17 stack measurements, the coplanar PCBs contributed on average less than 3% to total TEQ with a maximum contribution of 7.5% to total TEQ in one measurement. Differences in the design of the flue gas cooling section did not show an effect on the impact of coplanar PCBs on total TEQ. The effect of emission control devices on the impact of coplanar PCBs on the total TEQ was studied in more detail at one incinerator. The relative contribution of PCBs to total TEQ increased along the flue gas line. This was caused by a slightly higher removal efficiency for TEQ relevant PCDDs/PCDFs compared to coplanar PCBs by the bag filters and a higher destruction efficiency for PCDDs/PCDFs compared to PCBs by the SCR catalyst. Additionally, the removal efficiencies of the emission control devices (bag filters and catalyst) for other chlorinated aromatic compounds which have been proposed as TEQ indicator compounds (polychlorinated benzenes and polychlorinated phenols) were compared with those for PCDDs/PCDFs and coplanar PCBs. Removal efficiencies for polychlorinated benzenes or polychlorinated phenols considerably differed from those of PCDD/PCDF and coplanar PCBs. Implications for TEQ assessments using indicator compounds as proposed in the literature are discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏