1.
有机碳源条件下厌氧氨氧化ASBR反应器中的主要反应   总被引:10,自引:3,他引:7  
朱静平  胡勇有  闫佳 《环境科学》2006,27(7):1353-1357
采用5个已稳定运行在厌氧氨氧化状态的ASBR反应器,通过COD、氨氮、亚硝酸盐氮、硝酸盐氮、pH等指标的监测和好氧硝化菌、异养反硝化菌的测定,研究了不同有机碳源条件下反应器中发生的主要反应.结果表明,反应器中存在好氧硝化菌、异养反硝化菌和厌氧氨氧化菌.在COD、氨氮、亚硝酸盐氮等存在条件下,可发生好氧硝化、厌氧氨氧化和异养反硝化反应,先是好氧硝化反应、厌氧氨氧化反应和异养反硝化反应共存,其后依次是异养反硝化反应和厌氧氨氧化反应占主导地位.当C/NO2--N在1.7~1.9范围内时,C/NH4+-N为1.7的1号反应器具有最佳的厌氧氨氧化效果,反应结束时其COD去除率、NH4+-N去除率、NO2--N去除率分别为100%、81.7%和74.4%.  相似文献   

2.
为探究深水水库沉积物微生物功能特征及利用价值,于2019年在实验室对小湾水库表层沉积物微生物进行了驯化分离,并分析了其中一株细菌的脱氮效率.结果表明,分离出的细菌XW731经鉴定属于假单胞菌属(Pseudomonas sp.),是一种贫营养型好氧反硝化菌;在分别以NH4+-N、NO3--N和NO2--N为唯一氮源时,该菌对NH4+-N、NO3--N和NO2--N去除率分别为33.6%、68.5%和9.1%;以NH4+-N和NO3--N为氮源时,对NH4+-N和NO3--N去除率分别为66.4%、89.6%,同步硝化反硝化能力更强.将该菌投加到两种城市微污染水体后测试表明,该菌对城市河道水体的NH4+-N和NO3--N去除率分别为38.3%和42.4%,对城市降雨水体的NH4+-N和NO3--N去除率分别为22.2%和7.7%.  相似文献   

3.
膜曝气生物膜反应器同步硝化反硝化研究   总被引:3,自引:0,他引:3  
炭膜作为膜曝气生物膜反应器膜组件处理人工合成废水,在单一反应器内实现了同时去碳脱氮.结果表明,当进水COD和NH4-N浓度分别为338 mg/L和75 mg/L,HRT为14 h,炭膜腔内压力为13.6 kPa时,COD、NH+4-N和TN的去除效率分别为82.5%、 95.1%和84.2%.但是在反应器运行的后期TN去除效率明显下降,主要是因为高有机负荷导致无纺布上的微生物过度繁殖,严重影响了硝化过程的进行.通过荧光原位杂交和扫描电镜技术观察生物膜微生物结构,得出厌氧或兼氧菌主要分布在生物膜外层的缺氧区,而氨氧化菌主要分布在生物膜内层的好氧区.硝化细菌和反硝化细菌在生物膜内的共存实现了炭膜曝气生物膜反应器的同步硝化反硝化.  相似文献   

4.
低C/N高氨氮消化污泥脱水液部分亚硝化研究   总被引:3,自引:0,他引:3  
采用缺氧滤床+好氧悬浮填料生物膜工艺,在常温(15~29℃)高溶解氧(6~9 mg/L)条件下,于好氧反应器中实现和维持了脱水液部分亚硝化.试验结果表明:通过综合调控进水氨氮负荷(ALR)、进水碱度/氨氮、水力停留时间,可以调节出水NO2--N/NH4+-N比率.当进水氨氮平均为315.80mg/L、平均进水ALR 为0.43kg/(m3·d)、进水碱度/氨氮为5.25时,出水NO2-N/NH4+-N 为1.25左右,为后续ANAMMOX 工艺创造了进水基质条件。同时将好氧区游离氨(FA)控制在1.0~10.3mg/L,实现了亚硝酸盐氮累积率70%~80%的部分亚硝化。综合分析表明:通过动态调控维持反应器内适宜的FA浓度是实现部分亚硝化的主要影响因素。本研究开发了一种适合消化污泥脱水液水质特点的新型部分亚硝化技术。  相似文献   

5.
环流曝气塔中生物脱氮过程的研究   总被引:3,自引:0,他引:3  
利用环流曝气塔进行同时硝化/反硝化(sND)脱氮实验.实验中,分别采用不同降解性能的碳源以及采用不同的碳源投加方式,研究反应器内的脱氮过程,监测处理过程中NOx--N浓度和溶解氧DO的变化.实验显示,在COD 800mg/L+800mg/L的分批加料方式下,NH4+-N的降解得到加强,出水中NH4+-N浓度低于3mg/L;利用较难降解物质作为碳源时,利于反应器内低溶解氧条件的出现,促进了反硝化的进行,实验在采用醇类碳源时脱氮效果好于葡萄糖的情况.  相似文献   

6.
MBR中影响同步硝化反硝化的生态因子   总被引:40,自引:1,他引:39  
研究了DO、C/N、pH等生态因子对膜生物反应器同步硝化反硝化的影响.结果表明,只有在各生态因子保持得当的条件下,同步硝化反硝化才能顺利地进行.DO为1mg/L左右、C/N比为30左右、进水pH值约7.2左右时COD、NH4+、TN的去除率分别为96%、95%和92%.  相似文献   

7.
含海水污水的短程硝化反硝化   总被引:27,自引:3,他引:24  
采用SBR工艺通过控制游离氨(FA)浓度实现了含海水生活污水的短程硝化反硝化脱氮,并研究了不同海水盐度情况下,温度、pH值、NH4+-N负荷等诸因素对短程硝化反硝化的影响.试验结果表明:大生活用水范围内的海水盐度情况下仍可实现短程硝化反硝化,但不同海水盐度情况下的NH4+-N去除率与NHH4+-N负荷有关,随着海水占生活污水比例的增加NH4+-N负荷应逐渐减少.当NH4+-N负荷小于0.15kg/(kg·d)时,短程硝化的NH4+-N去除率仍可达到90%以上.升高温度有利于提高短程硝化脱氮效率,当温度从20℃升高到30℃时,亚硝化比增长速率增加1倍.反应温度应保持在25℃~30℃,pH值的最佳范围为7.5~8.5.较高的进水pH值有利于通过游离氨浓度控制亚硝酸型硝化的形成.  相似文献   

8.
赵丹  于德爽  李津  汪晓晨 《环境科学学报》2013,33(11):3007-3016
从稳定运行的ASBR厌氧氨氧化反应器中分离筛选出一株在缺氧和好氧条件下均具有高效反硝化能力的菌株ZD8,该菌株为假单胞属(Pseudomonas sp.),大小2 μm×0.25 μm,无鞭毛和芽孢.实验结果表明,缺氧条件下,ZD8最适合的碳源为柠檬酸钠;当C/N为10时,具有最佳的反硝化效果.菌株ZD8在缺氧条件下不具有硝化能力.在好氧条件下菌株ZD8获得最佳反硝化效果的C/N为22,最适合pH范围是7.2~9.9.菌株ZD8在好氧条件下具有高效的异养硝化能力,NH4+-N平均去除速率为8.3 mg·L-1·h-1.当以KNO3为氮源时ZD8的反硝化速率为13.1 mg·L-1·h-1;而以NaNO2为氮源时,其反硝化速率为6.98 mg·L-1·h-1.在同时存在NH4+-N和NO3--N或NH4+-N和NO2--N的系统中,菌株ZD8均首先利用NH4+-N发生硝化作用,NH4+-N的存在对反硝化具有抑制作用,并且NH4+-N对NO2--N的反硝化抑制作用更强;在同时存在NO3--N和NO2--N的系统中,菌株ZD8优先利用NO3--N进行好氧反硝化脱氮.  相似文献   

9.
添加原水改善SBR工艺处理猪场废水厌氧消化液性能   总被引:26,自引:7,他引:19  
采用序批式反应器(SBR)工艺直接处理猪场废水厌氧消化液,处理系统的效率较低,COD去除率仅有10%左右,NH4+-N去除率70%左右;处理出水水质较差,出水COD高于1 000mg/L,出水NH4+-N在200mg/L左右;处理系统的工作不稳定,效能逐渐恶化.在猪场废水厌氧消化液中添加部分未经厌氧消化的猪场废水(原水),处理系统的处理效率明显提高,COD去除率高于80%,出水COD降到250~350mg/L;NH4+-N去除率高于99%,出水NH4+-N小于10mg/L;处理系统的稳定性也得到增强.添加原水后,猪场废水厌氧消化液的BOD5/COD比值从0.19上升到0.54,BOD5/TN比值从0.28上升到2.04,增加了微生物生长和反硝化所需的碳源,强化了反硝化作用,不仅提高了总氮去除效率,而且通过回补碱度,维持了处理系统的pH值稳定.  相似文献   

10.
三维电极生物膜反应器全程自养脱氮的启动研究   总被引:1,自引:0,他引:1  
采用人工配制氨氮废水,对三维电极生物膜反应器进行全程自养脱氮的启动研究.反应器中阳极采用钌涂层钛棒,在阳极区电解水产氧供硝化菌进行硝化反应;阴极采用活性炭纤维毡,并在阴极区填充活性炭颗粒构建三维电极,在阴极区电解水产氢供反硝化菌完成反硝化过程.在进水NH4+-N浓度30 mg·L-1、温度30 ℃、HRT为24 h的试验条件下,通过调节DO和 pH实现对硝化和反硝化反应的控制.结果表明,经过挂膜、驯化、稳定这3个较为典型的阶段后,反应器对NH4+-N去除率达到了97.8%,TN的去除率为92.4%,成功实现了三维电极生物膜反应器全程自养脱氮的启动.扫描电镜结果显示,阴极活性炭纤维毡表面的细菌主要为短杆状假单胞菌,活性碳颗粒表面的细菌为微球反硝化细菌,同属氢自养反硝化细菌,反应器中稳定的自养脱氮系统逐步建立.  相似文献   

11.
Since the ammonia in the effluent of the traditional water purification process could not meet the supply demand, the advanced treatment of a high concentration of NH4 +-N micro-polluted source water by biological activated carbon filter (BACF) was tested. The filter was operated in the downflow manner and the results showed that the removing rate of NH4 +-N was related to the influent concentration of NH4 +-N. Its removing rate could be higher than 95% when influent concentration was under 1.0 mg/L. It could also decrease with the increasing influent concentration when the NH4 +-N concentration was in the range from 1.5 to 4.9 mg/L and the dissolved oxygen (DO) in the influent was under 10 mg/L, and the minimum removing rate could be 30%. The key factor of restricting nitrification in BACF was the influent DO. When the influent NH4 +-N concentration was high, the DO in water was almost depleted entirely by the nitrifying and hetetrophic bacteria in the depth of 0.4 m filter and the filter layer was divided into aerobic and anoxic zones. The nitrification and degradation of organic matters existed in the aerobic zone, while the denitrification occurred in the anoxic zone. Due to the limited carbon source, the denitrification could not be carried out properly, which led to the accumulation of the denitrification intermediates such as NO2 . In addition to the denitrification bacteria, the nitrification and the heterotrophic bacteria existed in the anoxic zone. __________ Translated from Environmental Science, 2006, 27(1): 69–73 [译自: 环境科学]  相似文献   

12.
以人工模拟生活污水为处理对象,研究了在不同好氧区溶解氧浓度对一体化膜泥法OCO反应器脱氮削碳的影响。结果表明:在进水COD均值为300mg/L,进水流量为20L/h时,缺氧区与混合区的DO随好氧区的DO而变;在DO为2mg/L左右时,具有较理想的脱氮削碳效果,出水氨氮、总氮和COD分别为0.5mg/L、8mg/L和12mg/L去除率分别达到99%、80%和96%;结合化学除磷,TP的去除率可达91%以上。  相似文献   

13.
为了研究溶解氧对SBR单级颗粒污泥自养脱氮系统的影响,基于活性污泥ASM3模型和短程硝化-硝化-反硝化模型,将颗粒污泥传质过程与氨氧化菌(AOB)、厌氧氨氧化菌(AAOB)、亚硝酸盐氧化菌(NOB)、反硝化菌(DNF)的生长过程、好氧内源呼吸及缺氧内源呼吸过程等耦合,建立了单级自养脱氮颗粒污泥动力学模型,并对颗粒内部基质浓度分布进行预测.结果显示,当DO为0.4mg/L时,好氧区和缺氧区(厌氧区)的比例为0.4:1;当DO为0.6mg/L时,颗粒污泥好氧区与缺氧区(厌氧区)的比例为3:1.同时,根据基质反应速率方程,建立了颗粒污泥的单级自养脱氮系统动力学模型,对SBR系统运行效果进行预测,结果显示,DO为0.6mg/L时,氨氮反应完全,亚硝酸盐氮和硝酸盐氮在5mg/L以下,总氮去除率模拟值为89%左右,略低于实际测量脱氮率95%.  相似文献   

14.
生活污水短程生物脱氮过程中N2O的产生与控制方法   总被引:1,自引:0,他引:1       下载免费PDF全文
 为降低和控制实际污水处理厂中N2O产生量,通过长期试验和间歇试验对SBR法实际生活污水全程及短程脱氮过程中N2O的主要产生源和影响因素进行了研究.结果表明:生活污水短程硝化反硝化过程中有N2O产生,并且N2O主要产生于短程硝化过程中,即氨氧化过程中,而反硝化作用没有N2O产生,且能够将氨氧化结束时,活性污泥中累积的溶解性N2O进一步还原为N2.短程硝化过程中,N2O产生量随进水氨氮浓度的升高而显著增加.DO浓度对N2O的产生与释放有重要的影响,DO浓度高于2mg/L和低于0.5mg/L N2O产生量均较低.DO低于0.5mg/L时,一方面,降低了曝气作用对N2O的吹脱,延长了N2O在活性污泥中的停留时间;另一方面,在活性污泥絮体内部形成缺氧区,促进了同步硝化反硝化,在硝化作用的同时,加强了反硝化作用对N2O的还原作用,利于N2O的减量控制.  相似文献   

15.
溶解氧对膜生物反应器处理高氨氮废水的影响   总被引:4,自引:0,他引:4  
采用膜生物反应器(MBR)处理高氨氮有机废水,探讨了溶解氧(DO)对有机物、氨氮、总氮等去除效果的影响。当进水COD1500mg/L,NH4+-N150mg/L,TP为15mg/L,pH7.5~8.0,MLSS控制在6000~7000mg/L,DO在0.5~4mg/L时对COD的去除效果没有明显影响,都可高达95%;在DO为4.0和2.0mg/L时对NH4+-N的去除率都很高,最高可达99.17%,在DO为0.5mg/L时明显降低,最低降至48.30%。在DO2.0mg/L时,取得了较好的同步硝化反硝化效果,COD、NH4+-N、TN去除率分别高达97%、97%、68%。MBR中硝化反应的比氨氮消耗速率与氨氮浓度成零级反应动力学,比氨氮硝化速率为0.0979/d,比常规处理系统中的污泥硝化活性高。  相似文献   

16.
采用间歇曝气在MBBR反应器中成功实现一段式部分硝化耦合厌氧氨氧化(PN/A)过程.结果表明,在实验温度为35℃,进水氨氮浓度为150.00mg/L,进水氮负荷为0.24kg/(m3·d),DO浓度为(1.41±0.24)mg/L条件下,反应器总氮去除效率达到83.74%.生物膜中厌氧氨氧化菌(AnAOB)和氨氧化菌(...  相似文献   

17.
石英砂表面活性滤膜去除地下水中氨氮的试验研究   总被引:1,自引:0,他引:1  
为研究石英砂滤料表面活性滤膜催化氧化地下水中氨氮的性能,采用已运行4年的中试石英砂滤柱,改变进水氨氮负荷并且长期持续过滤仅含氨氮的进水,考察该滤膜催化氧化氨氮的性能.结果表明:在进水氨氮浓度为0.8~1.3mg/L,水温为20~23℃,滤速为7m/h的试验条件下,滤料表面活性滤膜催化氧化氨氮的性能可长期保持稳定、高效;在溶解氧(DO)充足的条件下,氨氮的最大去除负荷为22.3g/(m3·h),且其与氨氮进水负荷正相关;氨氮的极限去除浓度受溶解氧的限制,且当DO不足时,滤速对溶解氧的消耗影响较大.  相似文献   

18.
利用SBR(序批式反应器)研究了不同ρ(NaCl)、曝气时间、ρ(CODCr)、进水ρ(NH4+-N)对AGS(好氧颗粒污泥)短程硝化反硝化的影响. 结果表明,在pH、温度和ρ(DO)为8.0、30 ℃和3 mg/L条件下,以及ρ(NaCl)、曝气时间、ρ(CODCr)和ρ(NH4+-N)为20 g/L、8 h、600 mg/L和70 mg/L时,ηA(NH4+-N去除率)和NAR(NO2--N积累率)达到最佳. 当进水ρ(NaCl)为10 g/L时,NOB(亚硝酸盐氧化菌)被完全抑制,AOB(氨氧化菌)能够保持正常活性. ρ(CODCr)较高时能够促进NAR的提高. 经过116 d的培养,AGS短程硝化反硝化的耐盐极限为50 g/L,此时ηA小于50%,AOB被严重抑制,AGS丧失硝化能力. AGS的同步硝化反硝化作用明显,SND(同步硝化反硝化率)平均值为24.2%,SNDV(同步硝化反硝化比速率)平均值为0.63 h-1,低ρ(DO)比高ρ(DO)下的SND同步硝化反硝化作用更为明显.   相似文献   

19.
高浓度氨氮消化污泥脱水液半短程硝化试验研究   总被引:3,自引:2,他引:1  
采用A/O工艺考察了消化污泥脱水液半短程硝化及维持的影响因素和控制方法.结果表明,在温度9~20℃、平均DO浓度5.4 mg/L、SRT 30 d左右时,进水氨氮负荷(以N计,下同)0.64 kg/(m3·d)的条件下启动,经过29 d实现了短程硝化,此后的65 d内,动态控制反应器游离氨FA>4 mg/L时,70%亚硝氮累积率的短程硝化得以维持;在实现短程硝化的基础上,进而实现了半短程硝化,出水氨氮与亚硝氮浓度比维持在1∶1.32左右;当氨氮负荷降至0.19 kg/(m3·d)时(FA<1 mg/L),短程遭到破坏,在不同FA下取样做FISH分析,进一步证明了高FA是维持半短程硝化的主要因素;在进水中COD为282 mg/L, C/N仅为0.85的条件下,由于实现了短程硝化,系统TN去除量约为91 mg/L.结果分析表明,消化污泥脱水液在中低温、高DO浓度、长SRT下,通过动态控制氨氮负荷和pH值等运行参数,在系统中维持适宜的FA浓度(>4 mg/L),可以实现并维持半短程硝化,为后续的厌氧氨氧化提供进水或回流到污水厂主流区而节省反硝化碳源.  相似文献   

20.
部分亚硝化-厌氧氨氧化耦合工艺处理污泥脱水液   总被引:16,自引:1,他引:15       下载免费PDF全文
在缺氧滤床+好氧悬浮填料生物膜工艺中实现部分亚硝化,然后进行厌氧氨氧化(ANAMMOX),考察其对高含氮、低C/N污泥脱水液的处理能力.结果表明,亚硝化反应器在15~29℃、DO 6~9mg/L条件下,通过综合调控进水氨氮负荷(ALR)、进水碱度/氨氮、水力停留时间(HRT)等运行参数,可以调节出水(NO2--N)/(NH4+-N)的比率,能够较好地实现部分亚硝化反应以完成厌氧氨氧化.当进水ALR为1.16kg/(m3·d),进水碱度/氨氮为5.1时,出水(NO2--N)/(NH4+-N)在1.2左右,(NO2--N)/(NOx--N)大于90%,进入ANAMMOX反应器的氮物质去除率达到83.8%.  相似文献   