首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 328 毫秒
1.
亚硝酸型反硝化除磷污泥驯化方式的比较   总被引:3,自引:1,他引:2       下载免费PDF全文
以14d作为目标驯化时间,采用SBR反应器比较了厌氧-缺氧(亚硝酸盐一次投加)、厌氧-缺氧-好氧(亚硝酸盐一次投加)、厌氧-好氧+厌氧-缺氧-好氧(亚硝酸盐一次投加)、厌氧-好氧+厌氧-缺氧-好氧(亚硝酸盐连续投加)4种亚硝酸型反硝化除磷污泥驯化方式的优劣.结果表明,经厌氧-好氧+厌氧-缺氧-好氧(亚硝酸盐连续投加)方法驯化后的污泥,能承受的亚硝酸盐初始浓度最高为80mg/L,吸磷速率最高为14mgP/(gVSS·h),所需要的亚硝酸盐投加量较少,是一种较好的亚硝酸型反硝化除磷污泥快速驯化方法.  相似文献   

2.
FNA对好氧吸磷的长期抑制及污泥吸磷方式转化   总被引:2,自引:2,他引:0  
马娟  李璐  俞小军  孙雷军  孙洪伟  陈永志 《环境科学》2015,36(10):3786-3793
本研究采用交替厌氧/好氧(An/O)SBR反应器,在21~23℃的条件下启动系统并长期投加亚硝酸盐,考察游离亚硝酸(FNA)对系统好氧吸磷性能的长期抑制作用及驯化后污泥吸磷方式的转化.结果表明,投加FNA后,污泥的释磷和吸磷能力不仅未受到抑制,比释磷速率和比吸磷速率反而高于投加前.FNA浓度(以HNO2-N计)低于0.53×10-3mg·L-1时,系统除磷率均大于96.9%;当FNA浓度提高至0.99×10-3、1.46×10-3、1.94×10-3mg·L-1时,系统除磷率均会大幅下降,分别经过50、12、30 d的运行,除磷率恢复至64.42%、67.33%、44.14%,说明抑制作用导致的除磷性能恶化可以恢复且长期驯化作用能缩短恢复过程.值得注意的是,在低于1.46×10-3mg·L-1范围内,随着FNA投加量的提高,好氧段亚硝酸盐的损失量不断增大.研究还发现,经FNA长期抑制的好氧除磷系统内污泥吸磷方式发生转变,硝酸盐型和亚硝酸盐型缺氧吸磷能力分别为驯化前的3.35倍和3.86倍,说明长期投加FNA有利于富集以NO-2为电子受体的反硝化聚磷菌;而且,长期驯化有利于系统内污泥的沉降.  相似文献   

3.
亚硝酸盐对A2O系统脱氮除磷的影响   总被引:2,自引:0,他引:2       下载免费PDF全文
在A2O系统中,通过分别向缺氧区和好氧区投加亚硝酸盐的方式,考察和分析了亚硝酸盐的存在对系统脱氮除磷性能的影响.结果表明,系统的硝化、反硝化及除磷性能均对亚硝酸盐的存在比较敏感.亚硝酸盐存在于好氧段时对硝化性能的影响较大,当好氧段亚硝酸盐浓度达到25mg/L时,系统硝化速率仅有5.26mg/(L·h).亚硝酸盐存在于缺氧段时对反硝化性能的抑制作用较大,且当亚硝酸盐长期存在于缺氧段时,系统的反硝化速率降低至11.83mg/(L·h),与正常情况相比下降了60%;亚硝酸盐存在于好氧段时会严重抑制聚磷菌的吸磷能力,系统磷去除率仅有22%.当亚硝酸盐存在于缺氧段时,会引发系统的污泥膨胀问题,导致聚磷菌流失,聚磷菌数量减少到2.02%左右,继而引发系统除磷效果严重恶化.  相似文献   

4.
在以可溶性淀粉为唯一碳源、进水含有硝态氮的缺氧-好氧SBR脱氮除磷系统中,研究了投配亚硝态氮对该乳酸发酵系统除磷的影响.试验结果显示,初始投加亚硝酸盐的浓度分别为2、5、10 mg·L~(-1)时对系统的缺氧吸磷及好氧吸磷都产生了抑制作用,缺氧阶段的释磷量和释磷速率随进水亚硝酸盐浓度的增大而升高.亚硝酸盐对缺氧期液相中乳酸和污泥中糖原的积累都有明显的影响,当亚硝酸盐浓度由0 mg·L~(-1)升至10 mg·L~(-1)时,乳酸浓度由14.06 mg·L~(-1)下降至1.56 mg·L~(-1),相反污泥中糖原的含量从235.69 mg·g~(-1)上升至272.97 mg·g~(-1)(以VSS计,下同),并且在好氧阶段糖原的消耗量增加,污泥的吸磷量也随之增加.研究表明,亚硝酸盐对淀粉直接发酵成乳酸的过程及糖原转化为乳酸的过程均有抑制作用.  相似文献   

5.
SBR中短程反硝化除磷菌的培养驯化研究   总被引:1,自引:1,他引:0  
以周期运行培养方式在间隙反应器中驯化以亚硝酸盐作为电子受体的反硝化除磷菌,并比较了硝酸盐和亚硝酸盐作为电子受体时反硝化除磷的效果.结果表明,经厌氧/好氧+厌氧/缺氧(连续投加硝酸盐)+厌氧/缺氧/好氧(连续投加亚硝酸盐)方式成功筛选出能以亚硝酸盐作电子受体的反硝化除磷菌,该系统磷的去除率可达88.62%;在外加硝酸盐,...  相似文献   

6.
反硝化除磷污泥的缺氧吸磷性能研究   总被引:2,自引:0,他引:2  
为探讨反硝化除磷过程中污泥的缺氧吸磷性能,利用厌氧/缺氧强化驯化得到的反硝化除磷污泥,通过间歇性试验考察不同电子受体类型、不同污泥浓度(MLSS)对吸磷过程的影响。试验结果表明,缺氧条件下反硝化除磷菌(DPB)利用硝酸盐作为电子受体能够彻底吸磷,其吸磷速率约为好氧吸磷的59%;若以亚硝酸盐为电子受体,浓度较低时(10.6 mg/L)的吸磷速率与硝酸盐为电子受体时相当,但较高的亚硝酸盐浓度(22.6 mg/L)会抑制反硝化除磷过程;适当提高污泥浓度能加快缺氧吸磷速度,而过高的污泥浓度会降低污泥对氮、磷的比去除速率,故应将MLSS控制在合理的范围内。  相似文献   

7.
马娟  王谨  俞小军  周猛  李光银  孙洪伟 《环境科学》2018,39(8):3775-3781
采用SBR反应器考察了投加不同浓度苯酚(5、10、30、50、100、150、200 mg·L~(-1))对强化生物除磷工艺(EBPR)系统除磷性能的影响.结果表明,苯酚浓度≤50 mg·L~(-1)时,COD及PO3-4-P的去除率均在85%以上,系统具有较好的污染物去除性能;而投加高浓度苯酚(≥100 mg·L~(-1)),反应器除磷性能大幅降低;当苯酚浓度为200 mg·L~(-1)时,系统仅经过22个周期便丧失除磷性能,COD平均去除率降至61.3%,且在短期内难以恢复.同时发现,长期投加苯酚导致EBPR系统污泥除磷性能受到抑制,且对好氧吸磷的抑制作用大于厌氧释磷.此外,低浓度苯酚条件下(≤50 mg·L~(-1)),因污泥对苯酚毒性逐渐适应,系统污泥微膨胀现象逐渐消失,而由高浓度苯酚引发的污泥膨胀却难以恢复.短期冲击实验表明,由投加苯酚导致的出水COD和磷浓度的波动可随着苯酚撤去而逐渐恢复,由此可知,苯酚冲击对系统除磷性能的抑制可逆.  相似文献   

8.
除磷亚硝化颗粒工艺启动及性能恢复   总被引:1,自引:1,他引:0  
李海玲  李冬  张杰  刘博 《环境科学》2019,40(3):1367-1374
针对生活污水低碳氮比的水质特点,采用SBR反应器接种低温储存的强化生物除磷颗粒污泥,来启动除磷亚硝化颗粒工艺,通过控制曝气强度及污泥龄实现除磷亚硝化的稳定运行,为后置CANON或厌氧氨氧化工艺(ANAMMOX)提供进水.污泥龄为30 d的条件下实现了出水TP小于0. 5 mg·L~(-1),COD浓度小于50 mg·L~(-1),亚硝酸盐氮积累率达到了90%以上.实验还得出,过高的曝气强度使除磷亚硝化性能恶化,可采用降低曝气强度和减小污泥龄的方式来改善除磷性能.污泥龄为40 d可以实现生活污水除磷亚硝化中的亚硝化性能进一步恢复,最终实现出水磷浓度保持在0. 5 mg·L~(-1)以下,COD及TP去除率分别稳定在80%及95%,亚硝酸盐积累率保持在90%以上,SVI值从初始的63 m L·g~(-1)降低到35 m L·g~(-1),颗粒污泥沉降性能良好,颗粒粒径在整个运行过程中保持在1 000μm以上.  相似文献   

9.
李祥  朱亮  黄勇  杨朋兵  崔剑虹  马航 《环境科学》2016,37(4):1467-1471
在多晶硅废水处理过程中,为了减少先除氟后脱氮工艺中酸碱的投加量.本实验运行反硝化反应器研究了先脱氮后除氟工艺中先脱氮的可行性.结果表明,废水中F-浓度对反硝化存在一定的影响.当F-浓度控制在750 mg·L~(-1)左右,反硝化污泥脱氮速率无明显影响,当F-浓度继续增加时,反硝化污泥的脱氮速率逐步降低.在处理含F-(浓度控制在800 mg·L~(-1))多晶硅清洗废水时,反硝化污泥的脱氮性能无明显影响,经过93 d的运行,总氮出水稳定在50 mg·L~(-1)以内,总氮去除率达到90%以上,去除速率达到5 kg·(m~3·d)~(-1).经计算,与传统先除氟后脱氮工艺相比,可节省大约70%的碱投加量和100%的酸投加量,极大地降低废水处理成本.  相似文献   

10.
厌氧-好氧-缺氧短程硝化同步反硝化除磷工艺研究   总被引:4,自引:0,他引:4  
构建了主要由厌氧-好氧-缺氧构成的短程硝化同步反硝化除磷工艺,并在常温条件下用于生活污水的处理.研究发现,通过调节反应器内好氧区的pH(8.2~8.7)和溶解氧(DO为3~5mg·L-1)能实现该工艺的快速启动,在好氧区内实现亚硝酸盐的累积.在稳定运行期内,DO是影响短程硝化的主要影响因素,好氧1区DO控制在1.5~2.0mg·L-1,好氧2区DO控制在0.5~1.0mg·L-1,好氧区内亚硝酸盐氮累积浓度稳定在5~10mg·L-1,氨氮去除率达到90%以上.各反应单元内碳源、硝酸盐和亚硝酸盐对除磷贡献的研究表明,该工艺的缺氧段实现了在不外加碳源的情况下以亚硝酸盐和硝酸盐共同作为电子受体的反硝化除磷,反硝化除磷量占系统总除磷量的80%以上.  相似文献   

11.
王文琪  李冬  高鑫  张杰 《环境科学》2021,42(9):4406-4413
采用生活污水接种人工配水下成熟短程硝化反硝化除磷颗粒,通过不同好氧/缺氧时长联合分区排泥优化调控短程硝化反硝化除磷系统运行.结果表明,调控好氧/缺氧时长联合分区排泥可实现系统的稳定运行.后期稳定期出水COD浓度在50mg·L-1以下,出水TN浓度低于15mg·L-1,TN去除率达83%左右并保持平稳,出水P浓度均在0.5mg·L-1以下,平均去除率为93.72%.同时,分区排泥(70%顶部污泥和30%底部污泥)可作为筛选微生物的途径,维持了良好的亚硝化和除磷性能,使粒径分布更为集中,并保证氨氧化菌(ammonia oxidizing bacteria,AOB)和反硝化聚磷菌(denitrifying phosphate accumulating organisms,DPAOs)的生长优势.缺氧时长的增加提高了缺氧异养菌的生长速率,使得缺氧异养菌分泌出更多的EPS,确保了颗粒污泥性状的改善和后续维持稳定.  相似文献   

12.
A bench-scale cyclic activated sludge technology (CAST) was operated to study the biological phosphorus removal performance and a series of batch tests was carried out to demonstrate the accumulation of denitrifying polyphosphate-accumulating organisms (DNPAOs) in CAST system. Under all operating conditions, step-feed CAST with enough carbon sources in influent had the highest nitrogen and phosphorus removal efficiency as well as good sludge settling performance. The average removal rate of COD, NH4+-N, PO43− -P and total nitrogen (TN) was 88.2%, 98.7%, 97.5% and 92.1%, respectively. The average sludge volume index (SVI) was 133 mL/g. The optimum anaerobic/aerobic/anoxic (AOA) conditions for the cultivation of DNPAOs could be achieved by alternating anoxic/oxic operational strategy, thus a significant denitrifying phosphorus removal occurred in step-feed CAST. The denitrification of NOx− -N completed quickly due to step-feed operation and enough carbon sources, which could enhance phosphorus release and further phosphorus uptake capability of the system. Batch tests also proved that polyphosphate-accumulating organisms (PAOs) in the step-feed process had strong denitrifying phosphorus removal capacity. Both nitrate and nitrite could be used as electron acceptors in denitrifying phosphorus removal. Low COD supply with step-feed operation strategy would favor DNPAOs accumulation.  相似文献   

13.
污泥龄及pH值对反硝化除磷工艺效能的影响   总被引:2,自引:1,他引:1  
以SBR成功富集后的反硝化聚磷菌(DPBs)为研究对象,分别考察了污泥龄(SRT,35、25、15 d)及pH值(7.5、8.0、8.5)对反硝化除磷过程的影响.结果表明,SRT从35d缩短至25d,使活性污泥浓度(MLVSS)从2821 mg·L-1降低为2301 mg·L-1,而污泥负荷(F/M,以COD/MLVSS计)从0.256kg·(kg·d)-1增加至0.312 kg·(kg·d)-1,虽然净释磷量及净吸磷量有所下降,但是由于污泥活性的增加,此阶段厌氧释磷、缺氧吸磷及比反硝化速率均达到最高,分别为25.07、15.92及9.45 mg·(g·h)-1,污泥含磷率从4.78%升为5.33%,出水PO43--P浓度保持在0.5 mg·L-1以下,即PO43--P去除率稳定在95%以上;当SRT进一步缩短为15d时,MLVSS低至1448 mg·L-1,污泥中DPBs占聚磷菌(PAOs)的比例从82.4%骤降为65.7%,表明过短的SRT使得DPBs逐渐从系统中流失,此阶段污泥含磷率降至3.43%,释磷、吸磷及比反硝化速率亦出现不同程度的降低.随着pH值的升高(7.5~8.0),厌氧释磷及缺氧吸磷速率也升高,pH值为8.0时分别达到25.86mg·(g·h)-1和16.62 mg·(g·h)-1;当pH超过8.0后,除磷效率快速下降,推测为磷化学沉淀导致.  相似文献   

14.
环丙沙星(Ciprofloxacin,CIP)是一种被广泛用于人类医学和动物疾病预防的抗生素类药物,在自然环境中普遍存在,以前的研究主要集中在采用不同方式对环境介质中的CIP进行吸附降解及CIP的药物作用上,有关其在污水处理过程中的迁移转化及对污水生物处理的影响尚不得而知.基于此,本文通过CIP在活性污泥处理污水中的迁移转化实验,解析其对污水生物处理过程的影响.实验结果表明:CIP的去除途径主要为生物吸附,且对低浓度CIP(0.003、0.03和0.3 mg·L~(-1))有较好的吸附效果,但高浓度CIP(3和6 mg·L~(-1))很难被去除;CIP短期/长期暴露对污泥活性及污泥生物细胞完整性无显著影响,但长期暴露会显著提高活性污泥沉降性能,同时会降低生物脱氮除磷的效率.CIP(0.05、0.5、5 mg·L~(-1))的存在使磷的去除率从97.1%±1.2%分别下降到95.8%±0.9%、89.1%±0.6%和74.3%±0.7%,出水中氨氮的去除率从96.1%±1.1%分别下降到94.6%±0.8%、87.9%±0.4%和70.2%±0.6%.机理实验表明,CIP通过抑制好氧阶段和缺氧阶段胞内聚合物聚羟基脂肪酸酯和糖原的转化来抑制磷的吸收和反硝化过程,这是CIP影响生物脱氮除磷的重要原因.此外,亚硝酸盐还原酶和多磷酸激酶的活性也受到CIP的抑制.  相似文献   

15.
张玉君  李冬  王歆鑫  张杰 《环境科学》2021,42(9):4383-4389
为了探究间歇梯度曝气下污泥龄对氨氧化菌(AOB)和亚硝酸盐氧化菌(NOB)的影响,研究短程硝化内源反硝化除磷系统对于处理低C/N比生活污水的优势作用,本文采用SBR反应器培养好氧颗粒污泥,实验进水采用实际生活污水.结果表明,在SRT由50 d逐渐降低至30 d过程中,比氨氧化速率由3.16 mg·(g·h)-1增加至4.38 mg·(g·h)-1,比亚硝酸盐氧化速率由3.4 mg·(g·h)-1降为1.8 mg·(g·h)-1左右,可知NOB活性降低约44%,从而使系统实现了短程硝化.当SRT为30 d时,由典型周期实验可知亚硝酸盐最大积累量可达6.93mg·L-1.由于系统中污泥浓度随SRT的减少而略有降低,因此在反应进行至40 d左右时根据DO曲线采取降低曝气量的策略,最终SRT为30 d时系统出水COD浓度为40.76 mg·L-1,TN浓度为12.4 mg·L-1,TP浓度为0.31 mg·L-1,强化了系统中C、N和P的同步去除,最终得到了稳定运行的短程硝化内源反硝化除磷系统.同时好氧颗粒污泥EPS含量与SRT呈现负相关性,蛋白质含量由污泥龄为50 d的66.7 mg·g-1升为30 d的95.1mg·g-1,多糖保持在12.1~17.2 mg·g-1的范围内,说明SRT的降低对蛋白质含量的影响较多糖大,当SRT为30 d时,PN/PS值保持在6.2左右,好氧颗粒污泥在该条件下仍能保持较好的结构稳定性.  相似文献   

16.
基于ABR-MBR组合工艺优化反硝化除磷性能的研究   总被引:5,自引:4,他引:1  
程朝阳  赵诗惠  吕亮  吴鹏  沈耀良 《环境科学》2016,37(11):4282-4288
基于ABR-MBR一体化反应器,以低C/N比生活污水为研究对象,结合厌氧折流板反应器(ABR)微生物相分离的特性,通过优化与ABR优质供碳和脱氮除磷相耦合的膜生物反应器(MBR)硝化液回流比以实现高效反硝化除磷,并对ABR-MBR污泥回流比进行优化.结果表明,在ABR段有机负荷为2.0 kg·(m3·d)-1、系统的水力停留时间(HRT)为9 h、泥龄(SRT)为15 d,系统获得最优的处理效果时的硝化液回流比和污泥回流比分别为300%和100%.其中TN和溶解性PO3-4-P平均去除率分别达84%和94%,ABR中反硝化除磷量可达系统总去除量的87%,平均出水TN和溶解性PO3-4-P浓度分别为12.98 mg·L-1和0.43 mg·L-1.  相似文献   

17.
为探究连续流条件下,纳米零价铁(nZVI)对反硝化颗粒污泥(DGS)性能的影响,本文利用升流式污泥床(USB),系统考察了反应器脱氮效能、污泥形态和反硝化特性随进水nZVI浓度的变化规律.结果表明,当nZVI5 mg·L~(-1)时,反应器脱氮效能与对照期(nZVI=0 mg·L~(-1))相差很小,DGS活性略微增大.当nZVI浓度在5~10 mg·L~(-1)时,DGS对nZVI的生物抑制作用表现出一定适应性,污泥浓度和颗粒粒径仍保持增长趋势,但泥相中总铁含量明显增大,DGS活性开始降低.当nZVI浓度增至30 mg·L~(-1)时,反应器对COD和NO-3-N的去除率分别降至对照期的23.3%和20.3%.DGS因吸附大量nZVI而呈黑色,颗粒粒径减小,污泥表面短杆菌等微生物密度明显降低.停止投加nZVI后,污泥浓度与DGS活性的持续上升,使得反应器脱氮效能在20 d内基本恢复至对照期的水平.异养菌在颗粒表面的快速增殖是实现上述目标的主要原因.  相似文献   

18.
为了解同步短程硝化内源反硝化除磷(SPNDPR)系统的脱氮除磷特性,以低C/N城市污水为处理对象,采用延时厌氧(180 min)/好氧运行的SBR反应器,通过联合调控曝气量和好氧时间,考察了该系统启动与优化运行特性.结果表明,当系统好氧段曝气量为0. 8 L·min~(-1),好氧时间为150 min时,出水PO_4~(3-)-P浓度约为1. 5 mg·L~(-1)左右,出水NH_4~+-N和NO_3~--N浓度由10. 28 mg·L~(-1)和8. 14 mg·L~(-1)逐渐降低至0 mg·L~(-1)和2. 27 mg·L~(-1),出水NO_2~--N浓度逐渐升高至1. 81 mg·L~(-1);当曝气量提高至1. 0 L·min~(-1)且好氧时间缩短至120min后,系统除磷、短程硝化性能逐渐增强,但总氮(TN)去除性能先降低后逐渐升高,最终出水PO_4~(3-)-P、NH_4~+-N分别稳定低于0. 5 mg·L~(-1)和1. 0 mg·L~(-1),好氧段亚硝积累率和SND率分别达98. 65%和44. 20%,TN去除率达79. 78%. SPNDPR系统内好氧段好氧吸磷、反硝化除磷、短程硝化、内源反硝化同时进行保证了低C/N污水的同步脱氮除磷.  相似文献   

19.
采用改良A2/O-BAF双污泥系统处理低C/N比生活污水,为提高碳源利用率,研究了两段进水(预缺氧段和缺氧段)对反硝化除磷脱氮的影响,同时根据COD的物料衡算公式,分析评价了不同进水比下,碳源的利用情况.结果表明当分段进水比为7:3时,平均进水COD、NH4+-N、TN、TP浓度分别为174.99、58.19、59.10、5.15 mg·L-1,出水COD、NH4+-N、TN、TP浓度分别为29.48、4.07、14.10、0.44 mg·L-1,去除率分别为82.12%、92.76%、75.45%、91.20%;系统中反硝化聚磷菌占聚磷菌的比例(DPAOs/PAOs)为98.81%,此时系统反硝化除磷脱氮最佳,同时碳源的有效利用率达85.77%,平衡百分比为92.33%.通过优化分段进水,碳源被有效利用,提高了同步脱氮除磷效率,为改良A2/O-BAF双污泥系统处理低C/N比污水提供理论依据.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号