首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
管网生物膜菌株胞外聚合物的提取方法比较   总被引:1,自引:0,他引:1  
以饮用水管网生物膜样品中一株强成膜能力的菌株Pleomorphomonas oryzae作为研究对象,考察了8种方法(高速离心法、超声法、加热法、EDTA法、H2SO4法、NaOH法、SDS法、甲醛法)对菌株胞外聚合物(EPS)的提取效果,并结合三维荧光光谱(EEM)和傅立叶红外光谱(FTIR)对提取的EPS进行成分分析.结果表明,EDTA法和H2SO4法既能提高EPS的提取效率,提取量分别为64.77 mg.g-1SS和74.43 mg.g-1SS,是离心方法提取量的1.62倍和1.86倍,又不会在提取过程中对菌株细胞造成破坏,是较为理想的EPS提取方法.EEM分析进一步证实,NaOH法对菌株细胞破坏严重,造成EPS成分变化较大.FTIR分析则说明,化学提取方法相较于物理提取方法会引入杂质对组分测定造成干扰.  相似文献   

2.
● Biofilm formation was enhanced by exogenous AHLs. ● EPS production and microbial adhesive strength of biofilm were promoted. ● Exogenous AHLs improved the performance of biofilters treating toluene. Biofilters are typical biofilm reactors, and they usually have poor biofilm formation resulting in limited reactor performance. Exogenous acylated homoserine lactones (AHLs) can enhance biofilm formation in many bioreactors based on quorum sensing regulation. However, their effect on biofilm in biofilters utilized for volatile organic compound (VOC) removal is unknown and needs to be investigated. In this study, the effects of the exogenous AHLs on biofilters for gaseous toluene removal were investigated. Analysis of biofilms in biofilters showed that the addition of exogenous AHLs considerably enhanced biofilm growth; the average biofilm concentration increased by 18%. Furthermore, the average biofilm coverage proportions in biofilters with and without exogenous AHLs were 17 % and 13 %, respectively, demonstrating the positive effect of exogenous AHLs on biofilm coverage. In particular, exogenous AHLs promoted the production of extracellular polymeric substances and the microbial adhesive strength of the biofilm. In addition, the exogenous AHLs showed no significant effect on the gaseous toluene removal efficiency of the biofilter. These results show that exogenous AHLs can enhance biofilm formation and can guide the application of exogenous AHLs in VOC biofilters.  相似文献   

3.
As the bioelectrochemical system, the microbial fuel cell (MFC) and the microbial electrolysis cell (MEC) were developed to selectively recover Cu2+ and Ni2+ ions from wastewater. The wastewater was treated in the cathode chambers of the system, in which Cu2+ and Ni2+ ions were removed by using the MFC and the MEC, respectively. At an initial Cu2+ concentration of 500 mg·L-1, removal efficiencies of Cu2+ increased from 97.0%±1.8% to 99.0%±0.3% with the initial Ni2+ concentrations from 250 to 1000 mg·L-1, and maximum power densities increased from 3.1±0.5 to 5.4±0.6 W·m-3. The Ni2+ removal mass in the MEC increased from 6.8±0.2 to 20.5±1.5 mg with the increase of Ni2+ concentrations. At an initial Ni2+ concentration of 500 mg·L-1, Cu2+ removal efficiencies decreased from 99.1%±0.3% to 74.2%±3.8% with the initial Cu2+ concentrations from 250 to 1000 mg·L-1, and maximum power densities increased from 3.0±0.1 to 6.3±1.2 W·m-3. Subsequently, the Ni2+ removal efficiencies decreased from 96.9%±3.1% to 73.3%±5.4%. The results clearly demonstrated the feasibility of selective recovery of Cu2+ and Ni2+ from the wastewater using the bioelectrochemical system.  相似文献   

4.
• Quorum sensing enhancement and inhibition methods are summarized. • Effects of quorum sensing regulation on biofilm are reviewed. • Current knowledge gaps and research challenges are proposed. Quorum sensing (QS) plays an important role in microbial aggregation control. Recently, the optimization of biological waste treatment systems by QS regulation gained an increasing attention. The effects of QS regulation on treatment performances and biofilm were frequently investigated. To understand the state of art of QS regulation, this review summarizes the methods of QS enhancement and QS inhibition in biological waste treatment systems. Typical QS enhancement methods include adding exogenous QS molecules, adding QS accelerants and cultivating QS bacteria, while typical QS inhibition methods include additions of quorum quenching (QQ) bacteria, QS-degrading enzymes, QS-degrading oxidants, and QS inhibitors. The specific improvements after applying these QS regulation methods in different treatment systems are concluded. In addition, the effects of QS regulation methods on biofilm in biological waste treatment systems are reviewed in terms of biofilm formation, extracellular polymeric substances production, microbial viability, and microbial community. In the end, the knowledge gaps in current researches are analyzed, and the requirements for future study are suggested.  相似文献   

5.
One of the most common taste and odour compounds (TOCs) in drinking water is 2-methylisoborneol (2-MIB) which cannot be readily removed by conventional water treatments. Four bacterial strains for degrading 2-MIB were isolated from the surface of a biological activated carbon filter, and were characterized as Micrococcus spp., Flavobacterium spp., Brevibacterium spp. and Pseudomonas spp. based on 16S rRNA analysis. The removal efficiencies of 2-MIB with initial concentrations of 515 ng·L-1 were 98.4%, 96.3%, 95.0%, and 92.8% for Micrococcus spp., Flavobacterium spp., Brevibacterium spp. and Pseudomonas spp., respectively. These removal efficiencies were slightly higher than those with initial concentration at 4.2 mg·L-1 (86.1%, 84.4%, 86.7% and 86.0%, respectively). The kinetic model showed that biodegradation of 2-MIB at an initial dose of 4.2 mg·L-1 was a pseudo-first-order reaction, with rate constants of 0.287, 0.277, 0.281, and 0.294 d-1, respectively. These degraders decomposed 2-MIB to form 2-methylenebornane and 2-methyl-2-bornane as the products.  相似文献   

6.
Effluents from wastewater treatment plant (WWTP) have been reported to have a broad spectrum of endocrine disrupting compounds (EDCs). The majority of studies have focused on the occurrence of estrogenic activity, while ignoring nuclear hormone receptors (NRs) pathways. In the present study, a battery of in vitro yeast bioassays and a cell bioassay, including antagonistic and agonistic effects on estrogen receptor (ER), androgen receptor (AR), progesterone receptor (PR), estrogen- related receptor (ERR) and aryl hydrocarbon receptor (AHR), were conducted to evaluate the removal efficien- cies of EDCs by different treatment processes of a WWTP located in Beijing. Estrogenic, anti-estrogenic, anti- androgenic, anti-progesteronic, anti-ERR and the activa- tion of AHR activities were detected in samples from all treatment processes and the receiving water. The concen- tration of estrogenic contaminants with estradiol (E2) equivalent concentrations ranged from 0.82 x 10-9 to 3.54 x 10 9g Ee_EQ.L-1. The concentration of anti-estrogenic contaminants with 4-hydroxytamoxifen (4-OHT) equiva- lent concentrations ranged from 1.24 × 10-6 to 2.36 x 10-6 g 4-OHT-EQ.L-1. The concentration of anti-androgenic contaminants ranged from 2.21 x 10-s to 3.52 × 10-6g flutamide-EQ. L-1. The concentration of anti-progesteronic contaminants ranged from 3.15 x 10^-5 to 2.71 x 10^-4g RU486-EQ. L-1. The concentration of anti-ERR contami- nants ranged from 7.09 x 10-5 to 6.50 x 104 g 4-OHT-EQ × L^-10. The concentration of AHR activators ranged from 1.7 × 10-10 to 3.4 × 10^-10g TCDD-EQ-L-1. These processes including secondary clarifier, coagulation, as well as coal and sand filtration could eliminated 67.2% of estrogenic contaminants, 47.0% of anti-estrogenic contaminants, 98.3% of anti-androgenic contaminants, 88.4% of anti- progesteronic contaminants, 65.4% of anti-ERR contami- nants and 46.9% of AHR activators. WWTP effluents contain multiple receptor disruptors may have very complex adverse effects on exposed organisms.  相似文献   

7.
The objective of this study is to investigate the occurrence of haloacetic acids (HAAs), a group of disinfection byproducts, in swimming pool and spa water. The samples were collected from six indoor pools, six outdoor pools and three spas in Pennsylvania, the United States, and from five outdoor pools and nine indoor pools in Beijing, China. Five HAAs (HAA5), including monochloroacetic acid, dichloroacetic acid, trichloroacetic acid, monobromoacetic acid, and dibromoacetic acid were analyzed. Total chlorine, pH and total organic carbon concentration were analyzed as well. Results indicated that the levels of HAA5 in swimming pools and spas in the United States ranged from 70 to 3980μg·L^-1, with an arithmetic average at 1440μg·L^-1 and a median level at 1150μg·L^-1. These levels are much higher than the levels reported in chlorinated drinking water and are likely due to organic matters released from swimmers' bodies. The levels of HAA5 in swimming pools in China ranged from 13 to 332μg·L^-1, with an arithmetic average at 117μg·L^-1 and a median level at 114μg·L^-1. The lower HAA levels in swimming pools in China were due to the lower chlorine residuals. Results from this study can help water professionals to better understand the formation and stability of HAAs in chlorinated water and assess risks associated with exposures to HAAs in swimming pools and spas.  相似文献   

8.
Lagoon-based municipal wastewater treatment plants (WWTPs) are facing difficulties meeting the needs of rapid population growth as well as the more stringent requirements of discharge permits. Three municipal WWTPs were modified using a high surface area media with upgraded fine-bubble aeration systems. Performance data collected showed very promising results in terms of five-day biochemical oxygen demand (BOD5), ammonia (NH3) and total suspended solids (TSS) removal. Two-year average ammonia effluents were 4.1 mg·L-1 for Columbia WWTP, 4 mg·L-1 for Larchmont WWTP and 2.1 mg·L-1 for Laurelville WWTP, respectively. Two- year average BOD5 effluents were 6.8, 4.9 and 2.7 mg·L-1, and TSS effluents were 15.0, 9.6 and 7.5 mg·L-1. The systems also showed low fecal coliform (FC) levels in their effluents.  相似文献   

9.
以乙二胺和抗坏血酸为原料,通过一步水热法制备了水溶性的氮掺杂碳量子点(N-CQDs).研究了N-CQDs的形貌特征、光学性能和应用分析.表征结果说明,N-CQDs形态为均匀分散的球形,有明显的晶格条纹,抗光漂白性能良好,表面富有含氧官能团,具有良好的水溶性.此外发现N-CQDs还具有优良的荧光性能和荧光稳定性,量子产率可以高达12.29%.分析得出,Hg2+对N-CQDs在1.0—120μmol·L-1范围内有一定的猝灭效应,可作为Hg2+的荧光探针,检出限达230 nmol·L-1.  相似文献   

10.
This paper reports the effects of shear force on anoxic granular sludge in sequencing batch reactors (SBR). The study was carried out in two SBRs (SBR1 and SBR2) in which sodium acetate (200mg COD·L^-1) was used as the sole substrate and sodium nitrate (40 mgNO3-N·L^-1) was employed as the electron acceptor. The preliminary objective of this study was to cultivate anoxic granules in the SBR in order to investigate the effects of shear force on the formation of anoxic granular sludge and to compare the properties of anoxic sludge in the SBR. This study reports new results for the values of average velocity gradient, a measure of the applied shear force, which was varied in the two SBRs (3.79 s^-1 and 9.76 s^-1 for SBR1 and SBR2 respectively). The important findings of this research highlight the dual effects of shear force on anoxic granules. A low shear force can produce large anoxic granules with high activity and poor settling ability, whereas higher shear forces produce smaller granules with better settling ability and lower activity. The results of this study show that the anoxic granulation is closely related to the strength of the shear force. For high shear force, this research demonstrated that: 1) granules with smaller diameters, high density and good settling ability were formed in the reactor, and 2) granular sludge formed faster than it did in the low shear force reactor (41days versus 76 days). Once a steady-state has been achieved, the nitrate and COD removal rates were found to be 98% and 80%, respectively. For low shear force, such as was applied in SBR1, this research demonstrated that: 1) the activity of anoxic granular sludge in low shear force was higher than that in high shear force, 2) higher amount of soluble microbial products (SMPs) were produced, and 3) large pores were observed inside the larger granules,which are beneficial for nitrogen gas diffusion. Electron microscopic examination of the anoxic granules in both reactors showed that the morphology of the granules was ellipsoidal with a clear outline. Coccus and rod-shaped bacteria were wrapped by filamentous bacteria on the surface of granule.  相似文献   

11.
Extraction of high-quality microbial DNA from contaminated environmental samples is an essential step in microbial ecological study. Based on previously published methods for soil and sediment samples, a modified pretreatment method was developed for extracting microbial DNA from heavily contaminated river sediment samples via selection of optimal pretreatment parameters (i.e., reagent solution, reaction duration, and temperature). The pretreatment procedure involves washing the river sediment sample for three times with a solution containing 0.1 mol·L-1 ethylene diamine tetraacetic acid (EDTA), 0.1 mol·L-1 Tris (pH 8.0), 1.5 mol·L-1 NaCl, 0.1 mol·L-1 NaH2PO4, and Na2HPO4 at 65°C with 180 r·min-1 for 15 min to remove humic materials and heavy metals prior to the employment of standard DNA extraction procedures. We compared the results of standard procedure DNA extraction following pretreatment, without pretreatment, and with using a commercial PowerSoilTM DNA Isolation Kit. The results indicated that the pretreatment significantly improved the DNA quality based on DNA yield, DNA fragment length, and determination of prokaryotic diversity. Prokaryotic diversity exhibited in the DNA with the pretreatment was also considerably higher than that extracted with the PowerSoilTM DNA Isolation Kit only. The pretreatment method worked well even with a small amount of sediment sample (0.25 g or even lower). The method provides a novel, simple, cost-effective tool for DNA extraction for microbial community analysis in environmental monitoring and remediation processes.  相似文献   

12.
This study aimed to investigate the effects of humic acid (HA) on residual Al control in drinking water facilities that used orthophosphate addition. The results showed that adding orthophosphate was an effective method for residual Al control for the raw water without HA. When orthophosphate was added at 1.0 min before the addition of poly aluminum chloride (PACl), the concentrations of soluble aluminum (Sol-Al) and total aluminum (Tot-Al) residue were 0.08 and 0.086 mg·L-1, respectively; both were reduced by 46% compared with the control experiment. The presence of HA would notably increase the residual Al concentration. For the raw water with 5 mg·L-1 of HA, the concentrations of Sol-Al and Tot-Al increased from 0.136 and 0.174 mg·L-1 to 0.172 and 0.272 mg·L-1, respectively. For water with a HA concentration above 5 mg·L-1, orthophosphate was ineffective in the control of residual Al, though there were still parts of orthophosphate were removed in coagulation. The amounts of Al removal were positively correlated with the solids freshly formed in coagulation. Similar to the raw water without HA, the best Al control was obtained with orthophosphate salt added at 1.0 min before PACl. HA concentrations in the raw water, solution pH, and the orthophosphate dosage suitable for residual Al control by orthophosphate precipitation were also investigated.  相似文献   

13.
A biocathode with microbial catalyst in place of a noble metal was successfully developed for hydrogen evolution in a microbial electrolysis cell (MEC). The strategy for fast biocathode cultivation was demonstrated. An exoelectrogenic reaction was initially extended with an H2-full atmosphere to enrich Ha-utilizing bacteria in a MEC bioanode. This bioanode was then inversely polarized with an applied voltage in a half-cell to enrich the hydrogen-evolving biocathode. The electrocatalytic hydrogen evolution reaction (HER) kinetics of the biocathode MEC could be enhanced by increasing the bicarbonate buffer concentration from 0.05 mol·L-1 to 0.5 mol· L-1 and/or by decreasing the cathode potential from -0.9 V to - 1.3 V vs. a saturated calomel electrode (SCE). Within the tested potential region in this study, the HER rate of the biocathode MEC was primarily influenced by the microbial catalytic capability. In addition, increasing bicarbonate concentration enhances the electric migration rate of proton carriers. As a consequence, more mass H+ can be released to accelerate the biocathode-catalyzed HER rate. A hydrogen production rate of 8.44 m3. m 3. d1 with a current density of 951.6 A. m-3 was obtained using the biocathode MEC under a cathode potential of - 1.3 V vs. SCE and 0.4 mol· L-1 bicarbonate. This study provided information on the optimization of hydrogen production in biocathode MEC and expanded the practical applications thereof.  相似文献   

14.
在接种了反硝化菌的剩余污泥中投加硝酸钙药剂,利用反硝化菌消耗NO3-进行反硝化作用去除污泥中易生物降解的有机物,利用Ca2+的中和、架桥作用,改善污泥的脱水性能.固定NO3-总投加浓度为100 mg·g-1 TS,在6 d的时间内,按1次、2次、3次、6次的投加频次向污泥中投加硝酸钙.结果表明,1次投加对污泥脱水性能的提升最显著,较对照组而言,污泥CST降低了65.0%,SRF降低了73.2%,污泥脱水性能明显改善;投加硝酸钙后,污泥胞外聚合物中蛋白质含量大幅降低,S层、L层蛋白质分别从13.47 mg·L-1、11.66 mg·L-1降低至0.52 mg·L-1、1.43 mg·L-1;投加硝酸钙的污泥Zeta电位更趋于电中性.研究还发现,一次性投加硝酸钙产生了更多NO2-,有利于污泥结合水,即微生物细胞质的释放.释放出的有机碳被反硝化菌用作碳源,又增强了反硝化效果,从而促进了污泥EPS的破坏与降解,从而改善了污泥的脱水性能.  相似文献   

15.
The effects of biologically active carbon (BAC) filtration on haloacetic acid (HAA) levels in plant effluents and distribution systems were investigated using the United States Environmental Protection Agency’s Information Collection Rule (ICR) database. The results showed that average HAA5 concentrations in all locations were 20.4 μg·L-1 and 29.6 μg·L-1 in ICR plants with granular activated carbon (GAC) and ICR plants without GAC process, respectively. For plants without GAC, the highest HAA levels were observed in the quarters of April to June and July to September. However, for plants with GAC, the highest HAA levels were observed in the quarters of April to June and January to March. This HAA level profile inversely correlated well with water temperature, or biologic activity. For GAC plants, simulated distribution samples matched well with distribution system equivalent samples for Cl3AA and THMs. For plants with and without GAC, simulated distribution samples overestimated readily biodegradable HAAs in distribution systems. The study indicated that through HAA biodegradation, GAC process plays an important role in lowering HAA levels in finished drinking water.  相似文献   

16.
低碳氮比(C/N)废水处理是含氮废水处理中的难题之一.本实验在C/N为4:1和2:1(COD和NH4+-N浓度分别为400 mg·L-1和100 mg·L-1,400 mg·L-1和200 mg·L-1)条件下,考察好氧颗粒污泥系统对低碳氮比废水的处理效果、长期运行稳定性,研究C/N对好氧颗粒微生物结构变化的影响.研究结果表明,在C/N为4:1的废水中接种活性污泥培养好氧颗粒污泥,形成的颗粒沉降性能良好,MLSS为4.94 g·L-1,SVI30为40 mL·g-1,COD去除率90%以上,氨氮去除率接近100%.降低碳氮比,即C/N为2:1后,好氧颗粒的物理及硝化性能无明显变化,MLSS为11.38 g·L-1,SVI30/SVI5维持在1左右,COD去除率大于85%,氨氮去除率98%.碳氮比降低使颗粒微生物多样性减少,其中陶厄氏菌受影响较小,而硝化功能菌出现更替:噬氢菌、食酸菌、里德拜特氏菌消失,鞘氨醇单胞菌、束缚杆菌等成为优势菌种.实验表明,该低碳氮比条件下好氧颗粒污泥系统能够稳定运行,且具有优良的处理性能.  相似文献   

17.
通过优化固相萃取条件和高效液相色谱-串联质谱参数,建立了可以同时检测地表水和地下水中26种典型药物及个人护理品(pharmaceuticals and personal care products,PPCPs),包括磺胺类、大环内酯类、喹诺酮类、酰胺醇类、精神类、消炎止痛类以及个人护理品的检测方法.通过将水样pH值调节至7,利用HLB固相萃取柱对水样中PPCPs进行富集,以甲醇和含0.005%甲酸的水溶液作为正离子模式流动相,甲醇和含0.5 mmol·L-1乙酸铵的水溶液作为负离子模式流动相进行梯度洗脱,采用多反应监测的质谱扫描模式(MRM)分析测定.26种PPCPs的检出限为0.007—1.78 ng·L-1,定量限为0.02—5.68 ng·L-1,回收率为52.28%—115.24%.利用该方法检测北京潮白河地表水和地下水中PPCPs的浓度,结果表明,地表水中PPCPs的含量普遍高于地下水,磺胺甲恶唑、舒必利、咖啡因、卡马西平和布洛芬在地表水和地下水中的含量相对较高,检测浓度分别高达147.83、52.48、78.35、166.58、30.63 ng·L-1.  相似文献   

18.
The increase of water ages drove the deterioration of drinking water quality. The relative abundance of Rhizobiales uniquely increase during distributing process. Rhizobiales order was helpful for inhibiting corrosion under high chlorine level. New disinfecting strategies should be developed to ensure drinking water safety. Bacterial community in the drinking water distribution system (DWDS) was regulated by multiple environmental factors, many of which varied as a function of water age. In this study, four water samples with different water ages, including finished water (FW, 0 d) and tap water (TW) [TW1 (1 d), TW2(2 d) and TW3(3 d)], were collected along with the mains of a practical DWDS, and the bacterial community was investigated by high-throughput sequencing technique. Results indicated that the residual chlorine declined with the increase of water age, accompanied by the increase of dissolved organic matter, total bacteria counts and bacterial diversity (Shannon). For bacterial community composition, although Proteobacteria phylum (84.12%-97.6%) and Alphaproteobacteria class (67.42%-93.09%) kept dominate, an evident regular was observed at the order level. In detail, the relative abundance of most of other residual orders increased with different degrees from the start to the end of the DWDS, while a downward trend was uniquely observed in terms of Rhizobiales, who was inferred to be chlorine-resistant and be helpful for inhibiting pipes corrosion. Moreover, some OTUs were found to be closely related with species possessing pathogenicity and chlorine-resistant ability, so it was recommended that the use of agents other than chlorine or agents that can act synergically with chlorine should be developed for drinking water disinfection. This paper revealed bacterial community variations along the mains of the DWDS and the result was helpful for understanding bacterial ecology in the DWDS.  相似文献   

19.
Metabolites of algae such as geosmin, 2-methylisoborneol etc. are reported to induce pungent odors into drinking water and attract additional scientific attention. Recently, in China, taste and odor outbreaks in drinking water supply have become increasingly common. In source water affected by eutrophication, dimethyl trisulfide, speculated to be produced by decayed algae, was found to be the source of taste and odor issues and can be removed effectively by usual oxidation agents. In this experimental study, batch scale tests were carried out focusing on the removal of dimethyl trisulfide. Reaction kinetics of dimethyl trisulfide oxidized by potassium permanganate in water had been studied; influence factors such as pH, organic substrate, other existed taste, and odor contaminant in equivalent concentration were also discussed. Results showed that dimethyl trisulfide can be removed by potassium permanganate efficiently; the ratio can reach more than 70% with oxidant dosage of 4 mg·L-1 and contact time prolonged to 120 min. The dimethyl trisulfide decomposition followed a second-order kinetics pattern with a rate constant k = 0.00213 L·(min·mg)-1. Typically, the degradation rate of dimethyl trisulfide was increased with the increasing KMnO4 dosage, but dramatically dropped with the increasing levels of humic acid (1.8–4.5 mg·L-1) and other odor-causing compounds (e.g. β-cyclocitral, 0–1886.0 μg·L-1). Solution pH (5.2–9.0) and initial dimethyl trisulfide concentration did not significantly affected the degradation. This study demonstrates that KMnO4 oxidation is an effective option to remove dimethyl trisulfide from water.  相似文献   

20.
Ozone kinetics of dimethyl sulfide in the presence of water vapor   总被引:1,自引:1,他引:0  
The outdoor smog chamber was used to thorough investigate the rate constants of gas-phase reaction between dimethyl sulfide (DMS) and ozone (O3) under conditions of relative humidity 55.0%-67.8% at (296±2)K for the first time. The rate constants were measured, at a total pressure of 1 atm, to be (10.4±0.2) × 10^-19 cm^3·molecule^-1·s^-1 at relative humidity of 67.5%±0.3% at 298K, (10.1±0.1) × 10^-19cm^3·molecule^-1·s^-1 at relative humidity of 66.5%±0.5% at 296K, (7.75±0.39) × 10^-19cm^3·molecule^-1·s^-1 at relative humidity of 64.8%± 0.1% at 294K and (3.42±0.21) × 10^-19cm^3·molecu- le^-1·s^-1at relative humidity of 55.8%±0.8% at 295K. Base on these results, it is possible to see the reaction of O3/ DMS in the presence of water vapor as an important sink for DMS in the earth atmosphere.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号