首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
ABSTRACT

According to the structure of photovoltaic/phase change material (PV/PCM), the mechanism of internal heat transfer, transmission, storage, and temperature control is analyzed, and a two-dimensional finite element analysis model of PV/PCM structure is established. This study is carried out on the effect of PCM thermal conductivity on internal temperature distribution characteristics of PV/PCM and temperature control characteristics of solar cells. The results show that the increase in thermal conductivity of PCM can prolong the temperature control time of solar cell in PV/PCM system, for example, when the thermal conductivity is increased from 0.2 W/(m·K) to1.5 W/(m·K) under a thickness of 4 cm, the duration when PV/PCM solar cell temperature is controlled below 40°C and extended from 52 min to 184 min. In addition, PV/PCM experimental prototypes are designed with the LA-SA-EG composite PCM peak melting point of 46°C and thermal conductivity of 0.8 W/(m·K) and 1.1 W/(m·K), respectively. The results indicate that compared with PCM-free solar cells, the maximum temperature of PV/PCM prototype solar cells with thermal conductivity of 0.8 W/(m·K) and 1.1 W/(m·K) is reduced by 10.8°C and 4.6°C, respectively, with average output power increased by 4.1% and 2.2%, respectively, under simulated light sources. Under natural light conditions, the average output power is increased by 6.9% and 4.3%, respectively. The results provide theoretical and experimental basis for the optimization of PV/PCM design by changing the thermal conductivity of PCM.  相似文献   

2.
Abstract: Urban impervious surfaces absorb and store thermal energy, particularly during warm summer months. During a rainfall/runoff event, thermal energy is transferred from the impervious surface to the runoff, causing it to become warmer. As this higher temperature runoff enters receiving waters, it can be harmful to coldwater habitat. In an urban watershed, impervious asphalt surfaces (roads, parking lots, and driveways) and pervious residential lawns comprise a significant portion of the watershed area. A paired asphalt‐turfgrass sod plot was constructed to compare the thermal runoff characteristics between asphalt and turfgrass sod surfaces, to identify meteorological variables that influence these thermal characteristics, and to evaluate evaporative heat loss for runoff from asphalt surfaces. Rainfall simulations were conducted during the summers of 2004 and 2005 under a range of climatic conditions. Asphalt surface temperatures immediately prior to rainfall simulations averaged 43.6°C and decreased an average of 12.3°C over 60 min as rain cooled the surface. In contrast, presimulation sod surface temperatures averaged only 23.3°C and increased an average of 1.3°C throughout the rainfall events. Heat transferred from the asphalt to the runoff resulted in initial asphalt runoff temperatures averaging 35.0°C that decreased by an average of 4.1°C at the end of the event. Sod runoff temperatures averaged only 25.5°C and remained fairly constant throughout the simulations. Multivariable regression equations were developed to predict (1) average asphalt surface temperature (R2 = 0.90) and average asphalt runoff temperature (R2 = 0.92) as a function of solar radiation, rain temperature, and wind speed, and (2) average sod surface temperature (R2 = 0.85) and average sod runoff temperature (R2 = 0.94) as a function of solar radiation, rain temperature, rain intensity, and wind speed. Based on a heat balance analysis, existing evaporation equations developed from studies on lakes were not adequate to predict evaporation from runoff on a heated impervious surface. The combined heat from the asphalt and sod plots was an average of 38% less than the total heat had the total area consisted solely of asphalt.  相似文献   

3.
The heat-pipe solar water heating (HP-SWH) system and the heat-pipe photovoltaic/thermal (HP-PV/T) system are two practical solar systems, both of which use heat pipes to transfer heat. By selecting appropriate working fluid of the heat-pipes, these systems can be used in the cold region without being frozen. However, performances of these two solar systems are different because the HP-PV/T system can simultaneously provide electricity and heat, whereas the HP-SWH system provides heat only. In order to understand these two systems, this work presents a mathematical model for each system to study their one-day and annual performances. One-day simulation results showed that the HP-SWH system obtained more thermal energy and total energy than the HP-PV/T system while the HP-PV/T system achieved higher exergy efficiency than the HP-SWH system. Annual simulation results indicated that the HP-SWH system can heat the water to the available temperature (45°C) solely by solar energy for more than 121 days per year in typical climate regions of China, Hong Kong, Lhasa, and Beijing, while the HP-PV/T system can only work for not more than 102 days. The HP-PV/T system, however, can provide an additional electricity output of 73.019 kWh/m2, 129.472 kWh/m2, and 90.309 kWh/m2 per unit collector area in the three regions, respectively.  相似文献   

4.
ABSTRACT

Stirling engines maintain attraction because of their high energy conversion efficiencies. In this study, experimental comparison of a beta-type Stirling engine for two different rhombic-drive mechanisms was presented. In one of the rhombic mechanisms, spur gears were used and the gear shaft was supported in bearings from one side. In the other mechanism, two helical gears were placed on crankshafts and the crankshafts were supported in bearings from both sides. Rhombus lengths of the mechanisms were determined as 66 mm and 80 mm to provide same constant compression ratio of 2.5 for both configurations. Both mechanisms were used in the same beta-type Stirling engine having same cylinder, piston and displacer dimensions. Performance parameters of the engines were evaluated at different helium charge pressures (2–4 bar) and hot-end temperatures (400–600°C). The hot-end of the displacer cylinder was heated by a liquefied petroleum gas (LPG) burner. The engine power increased by 132%, friction losses and gear noses were reduced by supporting the rhombic-drive mechanism from both side and using helical gears. The maximum output torque and power of the engine were obtained as 13.14 Nm at 428 rpm engine speed and 663 W at 800 rpm engine speed, respectively, at 600°C hot-end temperature and 4 bar charge pressure.  相似文献   

5.

Each plant has its own optimal drying temperature, especially for the medicinal herbs, because they are sensitive to heat. If the drying temperature becomes more than the optimal value, some chemical reactions will occur and influence the quality of the dried herb, such as color, taste, and aroma. While if the drying temperature becomes lower than the optimal value, the drying process will slow down, and consequently an expected degradation in the quality of the herb may occur, due to insects and fungi infestation which increase in moist conditions. This paper presents a new temperature control technique for a medicinal herb dryer system. The technique fixes the drying temperature of the medicinal herbs at 40°C, even in cases of rapidly changing atmospheric conditions. The control of the dryer temperature is achieved through using the proportional integral (PI) controller. The designed dryer contains two systems, which are the thermal and the electrical systems. The thermal system is designed to heat the drying air by using solar energy and bio-gas fuel. Whereas the electrical system, which contains a photovoltaic (PV) modules and a battery, is designed to supply the different electrical loads of the dryer system. The control technique is investigated through simulation work by using MATLAB-SIMULINK. The simulation results indicate the high capability of the proposed technique in controlling the drying temperature, even in cases of rapidly changing atmospheric conditions.  相似文献   

6.
Nano-textured polysilicon (poly-Si) solar absorption films are to be applied to the solar receiver of solar thermal electricity Stirling engine. These films were fabricated by deposition of hydrogenated amorphous silicon films (a-Si:H) into poly-Si films, using the pulse-wave modulation plasma and furnace annealing of the a-Si:H films. This is followed by wet etching of poly-Si films into nano-textured structures. The films are then coated with a-SiNx:H films as the antireflection and protection layers. It was observed that increasing the pulsed plasma turn-on (ton) time leads to deposition of less dense a-Si:H film with high hydrogen content and void density. This results in films having low dielectric constant and refractive index, and high optical bandgap. Less-dense a-Si:H film can be transferred into large grain size poly-Si film, using annealing. Also, highly rough nano-textured surface structure can be produced, by etching. The denser a-Si:H film, large grain size poly-Si film, and nano-textured surface poly-Si film can enhance the absorbance of sunlight and reduce the emissivity of far infrared light. The nano-textured poly-Si film coated with an a-SiNx:H layer can effectively increase the absorbance of sunlight to approximately 85% and reduce the emissivity of far infrared light to 49%. The nano-textured poly-Si/a-SiNx:H films can be used as efficient solar absorption films for solar thermal electricity Stirling engine.  相似文献   

7.
In this study, an experimental investigation on the performance of a small-scale residential-size solar-driven adsorption (silica gel-water) cooling system that was constructed at Assiut University campus, Egypt is carried out. As Assiut area is considered as hot, arid climate, field tests for performance assessment of the system operation during the summer season are performed under different environmental operating conditions. The system consists of an evacuated tube with a reflective concentration parabolic surface solar-collector field with a total area of 36 m2, a silica gel-water adsorption chiller of 8 kW nominal cooling capacity, and hot and cold water thermal storage tanks of 1.8 and 1.2 m3 in volume, respectively. The results of summer season field test show that under daily solar insolation varying from 21 to 27 MJ/m2, the solar collectors employed in the system had high and almost constant thermal efficiency. The daily solar-collector efficiency during the period of system operation ranged from about 50% to 78%. The adsorption chiller performance shows that the chiller average daily coefficient of performance (COP) was 0.41 with the average cooling capacity of 4.4 kW when the cooling-water and chilled-water temperatures were about 31°C and 19°C, respectively. As the chiller cooling water is cooled by the cooling tower in the hot arid area, the cooling water is at a higher temperature than the design point of the chiller. Therefore, an experiment was carried out using the city water for cooling. The results show that an enhancement in the chiller COP by 40% and the chilling power by 17% has been achieved when the city water was 27.7°C.  相似文献   

8.
Abstract

In this article, the convective heat transfer coefficients of various agricultural products were investigated under open sun drying conditions. Data obtained from open sun drying experiments for eight agricultural products, namely, mulberry, strawberry, apple, garlic, potato, pumpkin, eggplant, and onion were used to determine values of convective heat transfer coefficient. The value of convective heat transfer coefficient was determined as 1.861 W/m2°C for mulberry, 6.691 W/m2°C for strawberry, 11.323 W/m2°C for apple, 1.136 W/m2°C for garlic, 8.224 W/m2°C for potato, 8.613 W/m2°C for pumpkin, 6.981 W/m2°C for eggplant, and 6.767 W/m2°C for onion. The experimental error in terms of percent uncertainty was also calculated.  相似文献   

9.
Emitted thermal infrared radiation (TIR, λ= 8 to 14 μm) can be used to measure surface water temperatures (top approximately 100 μm). This study evaluates the accuracy of stream (50 to 500 m wide) and lake (300 to 5,000 m wide) radiant temperatures (15 to 22°C) derived from airborne (MASTER, 5 to 15 m) and satellite (ASTER 90 m, Landsat ETM+ 60 m) TIR images. Applied atmospheric compensations changed water temperatures by ?0.2 to +2.0°C. Atmospheric compensation depended primarily on atmospheric water vapor and temperature, sensor viewing geometry, and water temperature. Agreement between multiple TIR bands (MASTER ‐ 10 bands, ASTER ‐ 5 bands) provided an independent check on recovered temperatures. Compensations improved agreement between image and in situ surface temperatures (from 2.0 to 1.1°C average deviation); however, compensations did not improve agreement between river image temperatures and loggers installed at the stream bed (from 0.6 to 1.6°C average deviation). Analysis of field temperatures suggests that vertical thermal stratification may have caused a systematic difference between instream gage temperatures and corrected image temperatures. As a result, agreement between image temperatures and instream temperatures did not imply that accurate TIR temperatures were recovered. Based on these analyses, practical accuracies for corrected TIR lake and stream surface temperatures are around 1°C.  相似文献   

10.
Abstract

Heating and air-conditioning systems have very low exergetic efficiency as they dissipate primary energy resources at low temperatures usually between 90 and 60°C. This compounds the problem that buildings spend approximately 30% of all the energy consumed in the U.S. for heating and air-conditioning. The overall result is a large entropy production and long-term environmental degradation that can be resolved only by substituting primary energy resources by low-temperature, waste, or alternative energy resources, usually available below 50°C. For such a replacement to be feasible the environmental cost of exergy production must be factored into calculations and compatible HVAC systems must be developed without any need for temperature peaking or equipment oversizing. This article addresses environmental and often-conflicting problems associated with exergy production by HVAC systems and presents an analytical optimization and control algorithm. Results indicate that when a careful design optimization is accompanied by a dynamic control of the split between radiant and convective means of satisfying thermal HVAC loads, exergy efficient sustainable buildings may be cost effective and environmentally benign.  相似文献   

11.
ABSTRACT: Air temperatures are sometimes used as easy substitutes for stream temperatures. To examine the errors associated with this substitution, linear relationships between 39 Minnesota stream water temperature records and associated air temperature records were analyzed. From the lumped data set (38,082 daily data pairs), equations were derived for daily, weekly, monthly, and annual mean temperatures. Standard deviations between all measured and predicted water temperatures were 3.5°C (daily), 2.6°C (weekly), 1.9°C (monthly), and 1.3°C (annual). Separate analyses for each stream gaging station gave substantially lower standard deviations. Weather monitoring stations were, on average, 37.5 km from the stream. The measured water temperatures follow the annual air temperature cycle closely. No time lags were taken into account, and periods of ice cover were excluded from the analysis. If atmospheric CO2 doubles in the future, air temperatures in Minnesota are projected (CCC GCM) to rise by 4.3°C in the warm season (April-October). This would translate into an average 4.1°C stream temperature rise, provided that stream shading would remain unaltered.  相似文献   

12.
MgO nanocrystals were synthesized and doped with different concentrations in poly(methylmethacrylate) (PMMA) to prepare hybrid organic-inorganic coatings based on polymer nanohybrid thin films. The nanoparticles were found to be spherical with 62 nm diameter as determined by X-ray diffraction (XRD) and atomic force microscope (AFM). The coatings were characterized by spectroscopic tools such as optical absorption, transmission and fluorescence spectroscopy. The prepared nanohybrid films were spin-coated on cost-effective luminescent PMMA substrates doped with highly efficient luminescent dyes luminescent solar concentrators (LSCs). The outdoor photostability tests demonstrated enhanced protection against UVA radiation for coated LSCs compared to bare LSC substrates. The current–voltage characteristics of commercially produced LSC prototypes showed that the poor UV response of monocrystalline silicon solar cell can be improved by for LSCs coated by PMMA/MgO nanohybrid films which act as luminescent down shifting layer (LDSL).  相似文献   

13.
ABSTRACT: Discrete cold water patches within the surface waters of summer warm streams afford potential thermal refuge for cold water fishes during periods of heat stress. This analysis focused on reach scale heterogeneity in water temperatures as influenced by local influx of cooler subsurface waters. Using field thermal probes and recording thermistors, we identified and characterized cold water patches (at least 3°C colder than ambient streamflow temperatures) potentially serving as thermal refugia for cold water fishes. Among 37 study sites within alluvial valleys of the Grande Ronde basin in northeastern Oregon, we identified cold water patches associated with side channels, alcoves, lateral seeps, and floodplain spring brooks. These types differed with regard to within floodplain position, area, spatial thermal range, substrate, and availability of cover for fish. Experimental shading cooled daily maximum temperatures of surface waters within cold water patches 2 to 4°C, indicating a strong influence of riparian vegetation on the expression of cold water patch thermal characteristics. Strong vertical temperature gradients associated with heating of surface layers of cold water patches exposed to solar radiation, superimposed upon vertical gradients in dissolved oxygen, can partially restrict suitable refuge volumes for stream salmonids within cold water patches.  相似文献   

14.
Abstract: The summertime heating of runoff in urban areas is recognized as a common and consistent urban climatological phenomenon. In this study, a simple thermal urban runoff model (TURM) is presented for the net energy flux at the impervious surfaces of urban areas to account for the heat transferred to runoff. The first step in developing TURM consists of calculating the various factors that control how urban impervious areas absorb heat and transfer it to moving water on the surface. The runoff temperature is determined based on the interactions of the physical characteristics of the impervious areas, the weather, and the heat transfer between the moving film of runoff and the impervious surface common in urban areas. Key surface and weather factors that affect runoff temperature predictions are type of impervious surface, air temperature, humidity, solar radiation before and during rain, rainfall intensity, and rainfall temperature. Runoff from pervious areas is considered separately and estimated using the Green‐Ampt Mein‐Larson rainfall excess method. Pervious runoff temperature is estimated as the rainfall temperature. Field measurements indicate that wet bulb temperature can be used as a surrogate for rainfall temperature and that runoff temperatures from sod average just 2°C higher than rainfall temperatures. Differences between measured and predicted impervious runoff temperature average approximately 2°C, indicating that TURM is a useful tool for determining runoff temperatures for typical urban areas.  相似文献   

15.
Understanding temperatures used by hibernating bats will aid conservation and management efforts for many species. A limestone mine with 71 km of passages, used as a hibernaculum by approximately 30,000 bats, was visited four times during a 6-year period. The mine had been surveyed and mapped; therefore, bats could be precisely located and temperatures (T s) of the entire hibernaculum ceiling accurately mapped. It was predicted that bats should hibernate between 5 and 10°C to (1) use temperatures that allow a near minimal metabolic rate, (2) maximize the duration of hibernation bouts, (3) avoid more frequent and prolonged arousal at higher temperatures, (4) avoid cold and freezing temperatures that require an increase in metabolism and a decrease in duration of hibernation bouts or that could cause death, and (5) balance benefits of a reduced metabolic rate and costs of metabolic depression. The distribution of each species was not random for location (P < 0.000) or T s (P < 0.000). Myotis sodalis (Indiana bat) was most restricted in areas occupied, hibernating in thermally stable yet cold areas ( = 8.4 ± 1.7°C); 99% associated with cement block walls and sheltered alcoves, which perhaps dampened air movement and temperature fluctuations. Myotis lucifugus (little brown myotis) hibernated in colder, more variable areas ( = 7.2 ± 2.6°C). Myotis septentrionalis (northern myotis), Pipistrellus subflavus (eastern pipistrelle), and Eptesicus fuscus (big brown bat) typically hibernated in warm, thermally stable areas ( = 9.1 ± 0.2°C, = 9.6 ± 1.9°C, and = 9.5 ± 1.5°C, respectively). These data do not indicate that hibernacula for M. sodalis, an endangered species, should be manipulated to cool below 5°C.  相似文献   

16.
PEM water electrolysis is one of the most efficient methods for the production of hydrogen because of produced high purity of the gases and environmentally friendly. In the present study, Phosphorus-doped Graphene (PG) was synthesized by thermal annealing of triphenylphosphine (TPP) and graphene oxide (GO). The PG supported palladium (Pd/PG) electrocatalysts were synthesized by chemical reduction method and used as the cathode for hydrogen evolution reaction (HER) electrode. Structural properties and electrochemical performances of the synthesized Pd/PG electrocatalyst were studied by FE-SEM, EDS, ICP, FT-IR, XRD, and Cyclic voltammetry (CV) methods, respectively. The membrane electrode assemblies (MEA’s) were fabricated using Pd/PG as cathode for HER electrode and RuO2 as anode for OER electrode. Also, their electrochemical performances along with the corresponding hydrogen yields were evaluated in single cell PEM water electrolyzer at various experimental conditions such as different current densities from 0.1 to 2.0 A cm?2 and temperatures (28–80°C). The synthesized Pd/PG electrocatalyst was observed a current density of 1 A cm?2 with 1.95 V at 80°C. Further, long-term stability studies were carried out continuously up to 2000 h which showed a reasonable stability. Hence, the synthesized Pd/PG can be used as an alternative to Pt-based electrocatalysts for the HER in PEM water electrolysis.  相似文献   

17.
This work deals with the application of a Life Cycle Assessment approach for evaluating the environmental and energy impacts ascribed to the production of photovoltaic (PV) cells of first and second generations. PV technologies based on silicon and CuInSe2 (CIS) thin films were taken into account herein. PV systems prepared with amorphous silicon (a-Si) showed a low environmental impact and short energy payback time when compared to those ones obtained using crystalline silicon (c-Si). PV technologies associated with mono-crystal (mono-Si) and polycrystalline silicon (multi-Si) showed large emissions of CO2, nitrogen oxides, non-methane volatile organic compounds, particulates, and SO2 into air per square meter of PV panel processed. In addition, these technologies displayed a significant fossil fuel demand, biological oxygen demand, and global warming potential, which make them eco-unfriendly. Ribbon silicon (ribbon-Si) and CIS thin films showed intermediate impact scores, but further improvements in their production chain are needed before these devices are commercially used. The technologies examined herein were categorized in first- and second-generation technologies in order to compare their environmental impact and conversion efficiency. Much attention was also paid to the development of third-generation PV cells with improved conversion efficiencies and lower environmental impacts.  相似文献   

18.
Simulations of stream temperatures showed a wide range of future thermal regimes under a warming climate — from 2.9°C warmer to 7.6°C cooler than current conditions — depending primarily on shade from riparian vegetation. We used the stream temperature model, Heat Source, to analyze a 37‐km study segment of the upper Middle Fork John Day River, located in northeast Oregon, USA. We developed alternative future scenarios based on downscaled projections from climate change models and the composition and structure of native riparian forests. We examined 36 scenarios combining future changes in air temperature (ΔTair = 0°C, +2°C, and +4°C), stream discharge (ΔQ = ?30%, 0%, and +30%), and riparian vegetation (post‐wildfire with 7% shade, current vegetation with 19% shade, a young‐open forest with 34% shade, and a mature riparian forest with 79% effective shade). Shade from riparian vegetation had the largest influence on stream temperatures, changing the seven‐day average daily maximum temperature (7DADM) from +1°C to ?7°C. In comparison, the 7DADM increased by 1.4°C with a 4°C increase in air temperature and by 0.7°C with a 30% change in discharge. Many streams throughout the interior western United States have been altered in ways that have substantially reduced shade. The effect of restoring shade could result in future stream temperatures that are colder than today, even under a warmer climate with substantially lower late‐summer streamflow.  相似文献   

19.
ABSTRACT: Air temperatures are sometimes used as substitutes for stream temperatures. To examine the errors associated with this procedure, linear relationships between stream temperatures, T, and air temperatures, Ta, recorded for 11 streams in the central U.S. (Mississippi River basin) were analyzed. Weather stations were an average 42 miles (range 0 to 144 miles) from the rivers. The general equations, Tw= 5.0 + 0.75 Ta and Tw= 2.9 + 0.86 Ta with temperatures in °C, were derived for daily and weekly water temperatures, respectively, for the 11 streams studied. The simulations had a standard deviation between measurements and predictions of 2.7°C (daily) and 2.1°C (weekly). Equations derived for each specific stream individually gave lower standard deviations, i.e., 2.1°C and 1.4°C, respectively. Small, shallow streams had smaller deviations than large, deep rivers. The measured water temperatures follow the air temperatures closely with some time lag. time lags ranged from hours to days, increasing with stream depth. Taking into account these time lags improved the daily temperature predictions slightly. Periods of ice cover were excluded from the analysis.  相似文献   

20.
Basic research on the corrosive effect of flue gases has been performed at the BAM Federal Institute for Materials Research and Testing (Germany). Conditions at both high and low temperatures were simulated in specially designed experiments. Carburization occured in flue gases with high CO2 content and temperatures higher than 500 °C. In SO2 containing flue gases sulphur was detected in the oxide scale. At lower temperatures no corrosion was observed when gases with low humidity were investigated. Humidity higher than 1500 ppm was corrosive and all steels with Cr contents lower than 12% revealed corroded surfaces. At low temperatures below 10 °C a mixture of sulphuric and nitric acid condensed on metal surfaces. Acid condensation caused severe corrosion. Humidity, CO2, O2, and SO2 contents are the important factors determining corrosion. Below 300 °C acid condensation is the primary reason for corrosion. Low humidity and low temperatures are conditions which can be expected in the CO2 separation and treatment process. This work includes major conditions of the flue gas and CO2 stream in CCS plants and CCS technology.  相似文献   