首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
基于射流技术的生物转盘处理生活污水的试验研究   总被引:1,自引:0,他引:1  
阳文德  伍健东  周兴求  黄娟 《四川环境》2007,26(4):15-18,55
试验研究基于射流技术的生物转盘处理生活污水的特性,讨论污水流量、气水比对处理效果的影响,总结系统的最佳运行参数。试验系统通过射流曝气器可同时实现自吸污水、混合曝气及驱动转盘。结果显示,该系统对生活污水CODcr的去除率达80%以上。  相似文献   

2.
This paper aims at analyzing the feasibility of a waste heat recovery power generation plant based on parametric optimization and performance analysis using different organic Rankine cycle configurations and heat source temperature conditions with working fluid R-12, R-123, R-134a, and R-717. A parametric optimization of turbine inlet temperature(TIT) was performed to obtain the irreversibility rate, system efficiency, availability ratio, turbine work output, system mass flow rate, second-law efficiency, and turbine outlet quality, along the saturated vapor line and also on superheating at an inlet pressure of 2.50 MP in basic as well as regenerative organic Rankine cycle. The calculated results reveal that selection of a basic organic Rankine cycle using R-123 as working fluid gives the maximum system efficiency, turbine work output, second-law efficiency, availability ratio with minimum system irreversibility rate and system mass flow rate up to a TIT of 150°C and appears to be a choice system for generation of power by utilizing the flue gas waste heat of thermal power plants and above 150°C the regenerative superheat organic Rankine cycle configuration using R 123 as working fluid gives the same results.  相似文献   

3.
人工曝气生态净化系统治理黑臭河流的原理及应用   总被引:24,自引:0,他引:24  
人工曝气生态净化系统是一种辅以曝气复氧的生态处理工艺。本文介绍了人工曝气生态净化系统的构造、净化机理及其在治理福州白马支河的成功应用。近一年来的运行结果表明,该系统对黑臭河流的净化效果好,同时还可实现污水的资源化,适合于城市景观河道的治理。  相似文献   

4.
沈吉秀 《环境技术》2009,27(6):20-22
设计良好的导电回路对真空断路器灭弧性能的提高有着重要的意义。本文首先从结构上分析了三种不同导电回路的优缺点,接着,分析了三种不同导电回路的电动斥力和吹弧磁场,为通过选择不同导电回路,触头直径和开距提高真空断路器灭弧性能提供方法和思路。  相似文献   

5.
ABSTRACT: A laboratory investigation was conducted to determine the head losses at sewer pipe junctions (manholes) under surcharged conditions. A physical model of a manhole/pipeline system was constructed for head-loss measurements. Head-loss coefficients were determined for a variety of outlet-flow Reynolds numbers, surcharge levels, pipe sizes, flow configurations, and inlet-flow rates. Empirical formulas were also developed to estimate head-loss coefficients. The results indicate that head loss is insensitive to the amount of surcharge, but depends heavily on the flow configuration, relative flow rate, and the change of pipe diameter within the pipelines.  相似文献   

6.
In this work, the performance of a forced convection solar air heater was evaluated using using three packed bed absorber plate configurations and compared with flat absorber plate. The phase change material (paraffin wax) was packed in the pin-fin, trianglular and circular absorber plate configurations. The performance parameters such as, outlet air temperature, thermo-hydraulic efficiency, exergy efficiency and pressure drop were predicted and compared. The results showed that the packed bed absorber plate configurations using paraffin wax have higher outler air temperature in the range of 2–5°C with 3–40% higher thermo-hydraulic efficiency and 2–20% higher exergy efficiency when compared to flat absorber plate. However, the packed bed absorver plates have higher pressure drop when compared to flat absorber plate.  相似文献   

7.
A single-screw expander has been designed and manufactured independently. Based on this prototype, testing system has been built and performance experiment has been made. In this article, compressed air was used as working fluid and performance test for the prototype was finished at conditions including different rotational speed and different inlet pressure.

From the experimental data, it is shown that when inlet pressure less than 0.8MPa the output power increases with the increase of rotational speed because of not enough expansion; when inlet pressure more than 0.8MPa, the every biggest output power is appeared in the condition of rotational speed 2600 rpm. The test results also show that the total efficiency is influenced by rotational speed obviously, and the highest total efficiency of this machine is 69.64% in the condition of 3000 rpm and 15 bar.  相似文献   

8.
The transcritical CO2 Rankine cycle with liquefied natural gas (LNG) as cold source is a promising power system to utilize mid- and low-temperature heat source. Most previous works focused on thermodynamic and thermoeconomic analysis or optimization for the system. In this article, an off-design performance analysis for the system is conducted. An off-design mathematical model for the system is established to examine the variation of system performance with the variations of heat source mass flow rate and temperature. A modified sliding pressure regulation control strategy, which regulates turbine inlet pressure to keep the temperature difference between heat source temperature and turbine inlet temperature constant, is applied to control the system when off-design conditions happen. The results show that when the mass flow rate or the temperature of heat source is less or lower than that of design condition, both the net power output of system and the system exergy efficiency decrease, whereas when they are more or higher than the values of design condition, the net power output of system increases but the system exergy efficiency still decreases. In addition, both CO2 turbine and NG turbine could almost keep the designed efficiency values under the applied control strategy.  相似文献   

9.
This paper presents the performance of the solid-oxide fuel cell/gas turbine hybrid power generation system with heat recovery waste unit based on the energy and exergy analyses. The effect of air inlet temperature and air/fuel ratio on exergy destruction and network output is determined. For the numerical calculations, air inlet temperature and air fuel ratio are increased from 273 to 373 K and from 40 to 60, respectively. The results of the numerical calculations bring out that total exergy destruction quantity increases with the increase of air inlet temperature and air/fuel ratio. Furthermore, the maximum system overall first and second law efficiencies are obtained in the cases of air inlet temperature and air/fuel ratio equal to 273 K and 60, respectively, and these values are 62.09% and 54.91%.  相似文献   

10.
The device performance of double-pass V-corrugated solar air heaters with external recycle was investigated experimentally and theoretically. The comparison between V-corrugated and flat-plate collectors was made to show the thermal efficiency improvement with various operating parameters. The results show that the collector efficiency improvement of the recycling double-pass V-corrugated operation is much higher than those of the other configurations under various recycle ratios and mass flow rates. However, there exists the penalty on the power consumption increment due to implementing V-corrugated channel into the solar air heaters, an economic consideration on both the heat-transfer efficiency enhancement and power consumption increment for the double-pass V-corrugated device was also delineated. The experimental setup was carried out to validate the theoretical predictions, and the fairly good agreement between both results was achieved with the error analysis of 0.48-1.83%.  相似文献   

11.
Among the various configurations of fossil fuel power plants with carbon capture, this paper focuses on pre-combustion techniques applied to natural gas combined cycles. With more detail, the plant configuration here addressed includes: (i) the steam reforming of natural gas, based on an air-blown autothermal process, following a recuperative pre-reforming treatment, (ii) the water gas shift producing CO2 and H2, (iii) the separation of CO2 by means of a mixed physical–chemical absorption system using a MDEA solution, and (iv) a hydrogen fuelled combined cycle.Similar configurations have been studied quite extensively, being among the most attractive for full-scale realizations in a near-mid term future. This paper proposes a detailed thermodynamic study and optimization of the plant configuration, bringing to a reliable performance estimation based on today's best available technology as far as the various plant sections are concerned (gas and steam turbine, natural gas reforming process, CO2 separation). The predicted LHV efficiency for the base configuration is about 50%. Being this value at the top of the range quoted in the open literature studies (35–50%), the paper includes a quite extensive sensitivity analysis, showing that more conservative assumptions may bring to significantly poorer performance, especially considering the pretty large number of operating parameters involved in the process.  相似文献   

12.
Single-pass solar air heaters (SAHs) with two and six fins attached and packed with wire mesh layers were experimentally investigated. Wire mesh layers were used between the fins in the place of an absorber plate. The effects of air mass flow rate on the outlet temperature and thermal efficiency were studied. The results showed an increase in the thermal efficiency as the air mass flow rate was increased. The range of the mass flow rate used in this work was between 0.0121and 0.042 kg/s. It was found that for the same mass flow rate the SAH having six fins has higher efficiency compared to the system that has two fins. The maximum efficiencies for the SAHs were obtained at the mass flow rate of 0.042 kg/s. The maximum efficiencies for the six-finned and two-finned SAHs were 79.81% and 71.8%, respectively. In addition, the maximum temperature difference between the inlet and the outlet, ΔT, for the SAH with six fins exceeded the two-finned SAH for the same mass flow rates. The maximum ΔT was 51.1°C for the six-finned SAH and 44.2°C for the two-finned SAH. As expected, the maximum ΔT for each SAH was obtained at the lowest air mass flow rate (i.e., 0.0121 kg/s). A substantial enhancement in the thermal efficiency was achieved in comparison to the results of a single-flow packed bed collector with those of conventional collectors.  相似文献   

13.
ABSTRACT: Artificial aeration is used to prevent winter fish kills due to oxygen depletion in ice-covered lakes. Conventional aeration by air bubble plumes and other techniques usually mixes the water column and produces hazardous open water in the ice cover. A non-mixing winter lake aeration system which creates a fish refuge was designed and field tested to oxygenate the water and maintain water temperature stratification in a lake such that no open water is created. The system uses a cascade aerator and has a design discharge and dissolved oxygen input rate of 85 1/s and 70 kg/d, respectively. Aerated water is discharged near mid-depth with minimum disturbance of the ambient water through a specially designed diffuser. The system was tested in a shallow 3 m deep lake of 17 ha surface area during two winters and was found to perform as expected. Significant photosynthetic production of dissolved oxygen under the ice-cover was also observed during snow-free periods.  相似文献   

14.
The appropriate design and evaluation of a rainwater harvesting (RWH) system is necessary to improve system performance and the stability of the water supply. The main design parameters (DPs) of an RWH system are rainfall, catchment area, collection efficiency, tank volume and water demand. Its operational parameters (OPs) include rainwater use efficiency (RUE), water saving efficiency (WSE) and cycle number (CN). The sensitivity analysis of a rooftop RWH system's DPs to its OPs reveals that the ratio of tank volume to catchment area (V/A) for an RWH system in Seoul, South Korea is recommended between 0.03 and 0.08 in terms of rate of change in RUE. The appropriate design value of V/A is varied with D/A. The extra tank volume up to V/A of 0.15~0.2 is also available, if necessary to secure more water. Accordingly, we should figure out suitable value or range of DPs based on the sensitivity analysis to optimize design of an RWH system or improve operation efficiency. The operational data employed in this study, which was carried out to validate the design and evaluation method of an RWH system, were obtained from the system in use at a dormitory complex at Seoul National University (SNU) in Korea. The results of these operational data are in good agreement with those used in the initial simulation. The proposed method and the results of this research will be useful in evaluating and comparing the performance of RWH systems. It is found that RUE can be increased by expanding the variety of rainwater uses, particularly in the high rainfall season.  相似文献   

15.
ABSTRACT

Thermal potential for cooling and heating can be achieved by new configuration of earth–air heat exchanger (EAHE). This paper presents a numerical investigation of thermal performance of a spiral-shaped configuration of EAHE intended for the summer cooling in hot and arid regions of Algeria. A commercial finite volume software (ANSYS FLUENT) has been used to carry out the transient three-dimensional simulations and the obtained results have been validated using the experimental and numerical data obtained from the literature. The agreement between our simulation results and those from literature is very satisfactory. A parametric analysis of the new geometry of (EAHE) has been performed to investigate the effect of pitch, depth, pipe length and of the flow velocity on the outlet air temperature and the EAHE’s mean efficiency as well as its coefficient of performance (COP). It has been shown that when the pitch space varies between 0.2 and 2 m the difference of outlet air temperature increases by 6 °C. When the air velocity increases from 2 to 5 m/s the mean efficiency decreases from 60 % to 33 % and the COP of the EAHE decreases from 2.84 to 0.46.  相似文献   

16.
污水处理中影响微孔曝气充氧性能因素的研究   总被引:2,自引:0,他引:2  
对污水处理中微孔曝气充氧性能影响因素的研究是一个复杂而又重要的问题。本文对污水水质、曝气器通气量、曝气池运行负荷和方式等几个主要因素对微孔曝气充氧性能的影响进行了研究探讨。鉴于曝气系统能耗在污水处理厂中所占比重较大,加强对该问题的研究,以降低处理厂能耗,有较好的经济意义。  相似文献   

17.
Hydrogen-fed proton exchange membrane fuel cell (PEMFC) has to overcome high installation and operation cost before being adopted as a distributed power candidate. Cogeneration of power and heat is a good approach to increase hydrogen energy utilization rate. A PEMFC-based power and heat cogeneration system is proposed and established in the current study to investigate system’s technological and economical feasibility. This cogeneration of heat and power (CHP) system composes of a 2.5-kW fuel cell stack, hydrogen supply system, air supply system, water and heat management system, and heat recovery system. The control strategies to automate the system operation are realized by a programmable automation controller (PAC) system. Detailed measurement of the system is also constructed along with a web-based human–machine interface (HMI) platform to facilitate experiments and demonstration. Preliminary testing of the CHP system shows good performance of heat and power outputs. System’s electrical power conversion efficiency and thermal efficiency of the CHP system are measured at 38% and 35%, respectively. System combined efficiency therefore reached about 73%.  相似文献   

18.
The study of the heat transfer enhancement for the recycling double-pass V-corrugated solar air heaters, which implement the external recycle of flowing air, was investigated experimentally and theoretically. The comparison among different designs of V-corrugated, baffled and fins attached, and flat-plate collectors was made to show the device performance improvement with various operating parameters under the same working dimensions. The recycling double-pass V-corrugated device developed here was proposed in aiming to strengthen the convective heat-transfer coefficient and enlarge the heat transfer area. The error analysis of experimental results deviate by 0.85–2.46% from the theoretical predictions with the fairly good agreement, and both results show that the device performance of the recycling double-pass V-corrugated operation is better than those of the other configurations under various recycle ratios and mass flow rates. The suitable selections were obtained for operating recycling double-pass V-corrugated devices while considering with an economic viewpoint by both the collector efficiency enhancement and the power consumption increment.  相似文献   

19.
膜曝气生物膜反应器生物膜影响因素分析   总被引:1,自引:0,他引:1  
膜曝气生物膜反应器(MABR)是一种利用透气膜进行曝气,可以实现同步硝化反硝化的污水生物处理新工艺。本文阐述了膜曝气生物反应器生物膜的原理和特点,总结了国内外在该领域的研究成果,重点介绍了C/N、氧气压力、流速、生物膜厚度、温度和pH对生物膜性能的影响。  相似文献   

20.
生物填料塔处理餐厅污水的研究   总被引:3,自引:0,他引:3  
分别以自行开发的组合型填料和焦炭作生物载体构成的生物填料等塔对餐厅污水处理进行了试验研究,试验考察了污水入塔COD值对塔中DO的影响,观察到的结果表明:长期在高入塔COD下运行对生物膜系统的持久、稳定不利;水力停留时间取3h-4h,COD的容积去除负荷为4kg/m^3.d时,出水既可达标,又可保持较高的处理能力;鼓风曝气时,气水比取8-12可使出水达标,而功耗较低;在相同的微生物系统和操作条件下,布水布气性好的组合填料处理效果高于布水气性差的焦炭。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号