1.
ABSTRACT

According to the structure of photovoltaic/phase change material (PV/PCM), the mechanism of internal heat transfer, transmission, storage, and temperature control is analyzed, and a two-dimensional finite element analysis model of PV/PCM structure is established. This study is carried out on the effect of PCM thermal conductivity on internal temperature distribution characteristics of PV/PCM and temperature control characteristics of solar cells. The results show that the increase in thermal conductivity of PCM can prolong the temperature control time of solar cell in PV/PCM system, for example, when the thermal conductivity is increased from 0.2 W/(m·K) to1.5 W/(m·K) under a thickness of 4 cm, the duration when PV/PCM solar cell temperature is controlled below 40°C and extended from 52 min to 184 min. In addition, PV/PCM experimental prototypes are designed with the LA-SA-EG composite PCM peak melting point of 46°C and thermal conductivity of 0.8 W/(m·K) and 1.1 W/(m·K), respectively. The results indicate that compared with PCM-free solar cells, the maximum temperature of PV/PCM prototype solar cells with thermal conductivity of 0.8 W/(m·K) and 1.1 W/(m·K) is reduced by 10.8°C and 4.6°C, respectively, with average output power increased by 4.1% and 2.2%, respectively, under simulated light sources. Under natural light conditions, the average output power is increased by 6.9% and 4.3%, respectively. The results provide theoretical and experimental basis for the optimization of PV/PCM design by changing the thermal conductivity of PCM.  相似文献   

2.
Temperature fluctuation inside the cabinet of a household refrigerator significantly affects the quality of preserved food. Phase change material (PCM) is a latent heat storage system that can store and release the heat energy by changing its phase from liquid to solid and solid to liquid respectively. Therefore, use of PCM inside the refrigerator cabinet has the potential for minimizing the temperature fluctuation during the door opening and the power failure. However, very few studies in the literature were dedicated to investigating the role of PCM to reduce the temperature fluctuation. The aim of this work is to experimentally investigate the effects of PCM on temperature fluctuation inside the cabinet of a household refrigerator during the door opening and power failure. The results found that a significantly lower temperature fluctuation can be obtained using PCM. It was found that during the door opening condition the air temperature in the cabinet rose rapidly. However, when a PCM container was used, temperature variation was reduced to 3–5°C. During the power failure, the system with PCM maintained a lower temperature inside the storage chamber for a long period of time (about 2 hours). Moreover, the test results indicate that PCM maintains more stable temperature in the foodstuffs inside the refrigerator. This reduction of temperature fluctuation ultimately improves the quality of preserved food.  相似文献   

3.
A hybrid cooling system consisting of both a dry section and wet section is proposed in this paper as a means to conserving energy and water by combining the benefits of both dry and wet cooling modes. A new thermodynamic coupling characteristics computing model was established to identify the best combination of dry and wet cooling subsystems in the hybrid tower throughout year-round operation based on its air thermodynamic state under the “no plume” principle. A hybrid cooling tower in Inner Mongolia, China, consisting of an elliptical tube heat exchanger with rectangular fins and counter-flow wet packing, was designed as an example under the no plume principle. The minimum number of heat exchanger units in service and the corresponding thermodynamic operating parameters were obtained under a year-round operation. The tower exhibited notable advantages in regards to water conservation compared to the traditional evaporative cooling tower at an estimated yearly savings of 3.74 × 107 kg water.  相似文献   

4.
Natural circulation driven boiling systems are extensively used for passive heat removal, such as in nuclear power plants. The flashing phenomenon and the associated flow instabilities in a natural circulation loop are reported here. An experimental facility is constructed with a heater, an adiabatic riser, a condenser and an adiabatic down comer to study the instability regions. The experimental geometry is modeled using RELAP5. At high power (i.e., at 6 kW) flashing instability is observed when the inlet sub cooling is within the range of 7° C to 12° C. It is also found that the presence of an inlet restriction does not help to suppress the flashing induced flow oscillation. A good comparison between the experimental and numerical results is observed and this loop can be used for validation exercises of commercial codes.  相似文献   

5.
An untreated sewage source heat pump system directly makes use of the urban raw sewage instead of that treated by a sewage plant. At present In China, most systems adopt the indirect mode for avoiding the harmful effect of the sewage on the heat pump unit. In this article a direct-mode untreated sewage source heat pump system, which shows less theoretical analysis of the mathematical model, is theoretically designed and analyzed to simulate the system dynamic characteristics in the heating mode. The results show that the system COP changes from 4.1 to 3.4 and the heating capacity from 9.5 to 15.3 kW when the sewage inlet temperature is 12°C and the frequency increases from 18 to 32 HZ. The condenser heat-transfer coefficient increases with the frequency reducing while the change trend of evaporator heat-transfer coefficient is the opposite. The highest values of them are 303 and 1617 W.m?2?K?1, respectively. The frequency control simulation supplies the operation adjustment with theoretical instructions and some reference values.  相似文献   

6.
This paper presents the performance of the solid-oxide fuel cell/gas turbine hybrid power generation system with heat recovery waste unit based on the energy and exergy analyses. The effect of air inlet temperature and air/fuel ratio on exergy destruction and network output is determined. For the numerical calculations, air inlet temperature and air fuel ratio are increased from 273 to 373 K and from 40 to 60, respectively. The results of the numerical calculations bring out that total exergy destruction quantity increases with the increase of air inlet temperature and air/fuel ratio. Furthermore, the maximum system overall first and second law efficiencies are obtained in the cases of air inlet temperature and air/fuel ratio equal to 273 K and 60, respectively, and these values are 62.09% and 54.91%.  相似文献   

7.
ABSTRACT

Large-scale greenhouse solar dryers have been used for drying various products and this type of dryer is usually equipped with LPG burner as auxiliary heater, which creates more operating cost. To overcome this problem, phase change material (PCM) thermal storage was proposed to substitute for the LPG burner. In this work, the performance of a large-scale greenhouse solar dryer integrated with a PCM as a latent heat storage for drying of chili was investigated. Experimental studies were conducted to compare the performance of this dryer with that of another large-scale greenhouse solar dryer without the PCM thermal storage and open sun drying. Chili with an initial moisture content of 74.7% (w.b.) was dried to a final moisture content of 10.0% (w.b.) in 2.5 days, 3.5 days, and 11 days using the solar dryer integrated with the PCM thermal storage, the solar dryer without the PCM thermal storage and the open sun drying, respectively. The performance of the solar dryer integrated with the PCM thermal storage was also evaluated using exergy analysis. The exergy efficiency of the drying room of the solar dryer integrated with the PCM thermal storage and the solar dryer without the PCM thermal storage for drying of chili was found to be 13.1% and 11.4%, respectively and the thermal storage helps to dry chili during adverse weather conditions. The results of exergy analysis implied that the exergy losses from the dryer with the PCM should be reduced.  相似文献   

8.
The storage of fresh agricultural products is not easy because of its high moisture. Dehydration is an efficient preservation method. The investigation of drying modeling and transfer characteristics are important for selecting operating conditions and equipment design. The drying behavior of Lactuca sativa slices, with the thickness of 2 mm, was investigated at 60.0–80.0°C and 0.60–1.04 m sec?1 velocity in a convective hot air drier. The mass transfer during the drying process was described using six thin drying models. The convective heat transfer coefficient α and mass transfer coefficient kH were finally calculated. The results showed that the drying process could be separated into three stages including accelerating rate, constant rate, and falling rate period, which was influenced by hot air temperature and velocity, and the Modi?ed Page model agreed well with the experimental data. When the operating temperature was increased from 60.0°C to 80.0°C, α was found increased from 88.07 to 107.93 W·m?2·K?1, and kH increased from 46.32 × 10–3 to 68.04 × 10–3 kg·m?2·sec?1·ΔH?1. With the increase of air velocity from 0.60 to 1.04 m·sec?1, α was increased from 78.85 to 101.35 W·m?2·K?1, and kH was enhanced from 51.78 × 10–3 to 65.85 × 10–3 kg·m?2·sec?1·ΔH?1.  相似文献   

9.
Phase change materials (PCMs) that can store and release heat energy over the temperature range from 363 to 393 K are crucial for solar absorption cooling, and it is worthy to seek new solid-liquid PCMs candidates that melt and crystallize in this temperature range. In this paper, (E)-3-m-tolylbut-2-enoic acid (mTBEA) was applied as a PCM candidate. Its thermal energy storage properties and thermal stability were systematically investigated. The results showed that mTBEA melted at 382.9 ± 0.5 K and crystallized at about 364 K, with a melting enthalpy (ΔfusH) of 138.4 ± 6.9 J g?1 and showed good long-term cyclic stability and thermal stability. The supercooling of mTBEA was stabilized at about 20 K, indicating that the conservation condition of melted mTBEA could be simple. In addition, the melted mTBEA could release all the absorbed thermal energy upon crystallizing. Besides, mTBEA exhibited good thermal stability for it to be applied as PCM. Hence, mTBEA is a promising PCM candidate for solar absorption cooling. Furthermore, the heat capacity of mTBEA was measured by modulated temperature differential scanning calorimetry (MTDSC) over the temperature range from 198.15 to 431.15 K, and the molar thermodynamic functions, [HT-H298.15]m and [ST-S298.15]m, were calculated based on the fitted molar heat capacity data.  相似文献   

10.
ABSTRACT

Thermal potential for cooling and heating can be achieved by new configuration of earth–air heat exchanger (EAHE). This paper presents a numerical investigation of thermal performance of a spiral-shaped configuration of EAHE intended for the summer cooling in hot and arid regions of Algeria. A commercial finite volume software (ANSYS FLUENT) has been used to carry out the transient three-dimensional simulations and the obtained results have been validated using the experimental and numerical data obtained from the literature. The agreement between our simulation results and those from literature is very satisfactory. A parametric analysis of the new geometry of (EAHE) has been performed to investigate the effect of pitch, depth, pipe length and of the flow velocity on the outlet air temperature and the EAHE’s mean efficiency as well as its coefficient of performance (COP). It has been shown that when the pitch space varies between 0.2 and 2 m the difference of outlet air temperature increases by 6 °C. When the air velocity increases from 2 to 5 m/s the mean efficiency decreases from 60 % to 33 % and the COP of the EAHE decreases from 2.84 to 0.46.  相似文献   

11.
In this study, an experimental investigation on the performance of a small-scale residential-size solar-driven adsorption (silica gel-water) cooling system that was constructed at Assiut University campus, Egypt is carried out. As Assiut area is considered as hot, arid climate, field tests for performance assessment of the system operation during the summer season are performed under different environmental operating conditions. The system consists of an evacuated tube with a reflective concentration parabolic surface solar-collector field with a total area of 36 m2, a silica gel-water adsorption chiller of 8 kW nominal cooling capacity, and hot and cold water thermal storage tanks of 1.8 and 1.2 m3 in volume, respectively. The results of summer season field test show that under daily solar insolation varying from 21 to 27 MJ/m2, the solar collectors employed in the system had high and almost constant thermal efficiency. The daily solar-collector efficiency during the period of system operation ranged from about 50% to 78%. The adsorption chiller performance shows that the chiller average daily coefficient of performance (COP) was 0.41 with the average cooling capacity of 4.4 kW when the cooling-water and chilled-water temperatures were about 31°C and 19°C, respectively. As the chiller cooling water is cooled by the cooling tower in the hot arid area, the cooling water is at a higher temperature than the design point of the chiller. Therefore, an experiment was carried out using the city water for cooling. The results show that an enhancement in the chiller COP by 40% and the chilling power by 17% has been achieved when the city water was 27.7°C.  相似文献   

12.
Variation in drying material and their biological differences, coupled with heat supply method in different dryers, makes mathematical modeling of drying complicated. Attempt was made to simulate a drying process and to identify best suitable model out of six selected drying models, for drying of ginger slices in a solar-biomass integrated drying system designed and developed for spice drying. Moisture content data were converted into the moisture ratio (MR) expressions and curve fitting with drying time for the selected drying models was analyzed. Sigma Plot software was used for nonlinear regression to the data obtained during drying and for modeling of drying curves. The suitability of the models was evaluated in terms of statistical parameters such as coefficient of determination (R2), mean percentage error (P), and standard error estimate. Drying air temperature was in the range of 47–55°C and air velocity was between 1.0 and 1.3 m s?1. Ginger slices were dried from 88.13% to 7.65 ± 0.65% (wb) in 16 h. Trays were interchanged in a predetermined matrix sequence from 4 h onwards when moisture content was reduced to 60–70% (wb), for uniformity in drying. Highest value of R2 (0.997), lowest value of SEE (0.020), and P value < 0.0001 established Page model as the best suitable model for the developed drying system. The predicted MRs were in good agreement with the experimental values and the effective moisture diffusivity for ginger was found to be 2.97 × 10–7 m2 s?1.  相似文献   

13.
An organic Rankine cycle (ORC) is generally used for converting low-grade heat into electricity. In this study, an extensive literature survey was conducted to identify current research gaps on experimental ORC systems. Specifically, there is limited experimental data and limited details on thermal and expander efficiencies of ORC systems. In order to address these gaps, the objective of this study included developing a turbine ORC with a power output exceeding 50 kW and thermal efficiency exceeding 8% for a heat source temperature < 120°C. The experimental results indicated that the system achieved a net power output of 242.5 kW and a thermal efficiency of 8.3% (the highest value for a turbine ORC system for the heat source temperature below 120°C). Thus, the study addressed the gaps identified in the research area of ORCs.  相似文献   

14.
Experiments are described to investigate the thermal performance of a discharging heat exchanger for a small storage tank filled with oil. Experimental results are presented in terms of the discharging energy rates (power) and the discharging exergy rates for low (~4 ml/s) and high discharging flow rates (~8 ml/s). Water heating energy rates, which are respectively maximized at approximately 600 W and 1200 W at low and high flow-rate discharging, are found to be higher than the discharging energy rates, which are respectively maximized at 450 W and 900 W. These results indicate that the energy rates do not accurately evaluate the thermal performance of the discharging heat exchanger since the energy heating rate of the water is greater than that for the oil that heats it, which is thermodynamically inconsistent. The energy rates should thus be used with caution when the thermal performance of the heat exchanger is evaluated. Water heating exergy rates, which are respectively maximized at approximately 45 W and 130 W at low and high flow-rate discharging, are generally smaller than the discharging exergy rates, which are respectively maximized at 65 W and 170 W. Exergy rate results are thus more consistent in the physical process of water heating, and an exergy factor is suggested as a proper measure for evaluating the performance of the discharging heat exchanger. The maximum value of the exergy factor is found to increase from 0.15 at low flow rates to a maximum value of approximately 0.19 at high flow rates. This implies that to extract more energy from a storage tank to a discharging heat exchanger, the flow rate has to be high, which is consistent with the physical process of heating water faster to higher temperatures. The exergy factor can thus be used as a design parameter for discharging heat exchangers.  相似文献   

15.
In this research, desert sand is used as the sensible heat storage medium, which exchanges heat with air in the downcomer to realize heat storage and heat release. The desert sand distribution uniformity has a significant impact on the heat exchange performance and efficiency between desert sand and air for the process of convection in the downcomer. Given the superiority of sensible heat storage in convective heat transfer between desert sand and air, distributors with cylinder or conical bore solid particles and homogeneity performance testing device are designed and manufactured on the basis of convection system equipped with solid particle–air downcomer. Then, the convection experiment between solid sand and air is researched. The greater the desert sand flow rate and higher the volume density, the larger the variance of regional mass flow rate and the worse the homogeneity performance. For the cylinder bore distributor, the smaller the sand particle size is, the greater affected the sand groups can be. The sand homogeneity performance is preferable with the two particle size ranges: 0.18-0.25 mm and 0.15-0.18 mm. The total sand flow rate decreases, but the uniformity improves with the increase of the air flow velocity, and the best distribution performance is achieved at an air velocity of 0.6 m/s. However, the distribution performance declines with the air flow velocity persistently increasing because the sand groups are pushed to one pipe side close to the wall. The sand groups deflect seriously with the air flow velocity increasing.  相似文献   

16.
This paper aims to reveal the heat transfer mechanism of low-temperature phase change material (PCM) and design PCM heat storage device in building heating environment. Firstly, low-temperature binary PCMs of lauric acid and stearic acid are prepared, and their thermal properties are investigated by DSC. Then, shell and tube latent heat thermal energy storage units are conducted, and heat transfer experiments are carried out to analyze the heat transfer mechanism of PCM. The results demonstrate that natural convection plays an important role in heat transfer process, and the heat storage efficiency of PCMs can be significantly enhanced by increasing the fin width and improving the inlet heat transfer fluid (HTF) temperature. Furthermore, some proposals are put forward to guide the design of PCM storage device in building heating environment.  相似文献   

17.
ABSTRACT

Energy optimization is performed on hybrid solar-geothermal power plant working according to Organic Rankine Cycle and installed in southern Tunisia. The performances of four different configurations of the power plant are studied. Mass and energy balances are established for the different compounds. The effects of the main operating parameters such as the geothermal water temperature, ambient temperature and direct normal irradiation on the power plant performances are analyzed. A code is established using Engineering Equation Solver software (EES) to perform the required calculations. Obtained results show that the hybrid solar-geothermal power plant with a heat recovery system is the most suitable configuration design giving a better overall energy efficiency of 15.77 and13.11% and a maximum net power of 1089 and 1882 kW in winter and summer, respectively. However, in the summer season, using a heat recovery system can valuable only when the water temperature is higher than 66°C. For air-cooled condenser, the suitable condensing pressure is 1 bar in winter and 1.9 bars in summer.  相似文献   

18.
This paper presents a change in the Scottish forestry policy from the exogenous to the endogenous development approach, and feasibility of heat entrepreneurship based on locally produced woodfuels in the Highlands of Scotland. The cost structure and heat pricing in the case of an 800 kW solid fuel boiler is presented, and the profitability of local heat entrepreneurship is analysed with scenarios of different investment costs and fuel prices. The results indicate that a district heating (DH) system, using locally produced woodchips, could produce heat at a lower price than single-house heating systems using light fuel oil. The profitability of replacing existing heating units by investing in a new district heating (DH) scheme is very dependent on the available investment support, price level of woodchips and substituted light fuel oil, and the amount of sold energy. In the case of an 800 kW DH scheme, and woodchip prices of 14 and 22 €/MWh, investments should remain under break-even points of 280 and 420 €/kW of heating power (230,000–335,000€).  相似文献   

19.
ABSTRACT: Temperature and dissolved oxygen concentrations were measured monthly from January 1971 to December 1982 at 1-m depth intervals at 13 stations in Keowee Reservoir in order to characterize spatial and temporal changes associated with operation of the Oconee Nuclear Station. The reservoir water column was i to 4°C warmer in operational than in non-operational years. The thermo-dine was at depths of 5 to 15 m before the operation of Oconee Nuclear Station, but was always below the upper level of the intake (20 m) after the station was in full operation; this suggests that pumping by the Oconee Nuclear Station had depleted all available cool hypolimnetic water to this depth. As a result summer water temperatures at depths greater than 10 m were usually 10°C higher after plant operation began than before. By fall the reservoir was nearly homothemious to a depth of 27 m, where a thermocine developed. Seasonal temperature profiles varied with distance from the plant; a cool water plume was evident in spring and a warm water plume was present in the summer, fall, and winter. A cold water plume also developed in the northern section of the reservoir due to the operation of Jocassee Pumped Storage Station. Increases in the mean water temperature of the reservoir during operational periods were correlated with the generating output of the power plant. The annual heat load to the reservoir increased by one-third after plant operations began. The alteration of the thermal stratification of the receiving water during the summer also caused the dissolved oxygen to mix to greater depths.  相似文献   

20.
Evaporative cooling of water in a small porous clay vessel was studied under controlled humidity conditions. In steady-state experiments performed at an ambient temperature of 23 °C, the cooling effect increased from 4.7 to 8.3 °C as the ambient relative humidity decreased from 60 to 15%. External heat and mass transfer coefficients, estimated from the steady-state measurements, were used in mathematical models to predict the experimentally observed transient temperature variation of the water under ramp changes of the ambient relative humidity. With a prototypical cool chamber containing water tested in Kolkata, India under an ambient temperature of 34.5–35 °C, the cooling effect reached a maximum of 7 °C between 3 and 3:30 PM and then declined to 4.5 °C around 6 PM.  相似文献   