首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 625 毫秒
1.
Radon daughter levels have been monitored in 12,000 Swedish dwellings during the last two years. In 1979 the Swedish Government introduced temporary limits for the radon daughter concentration in dwellings. For existing buildings this limit is 400 Bq/m3 (0.11 WL). Two different methods were used to monitor the radon daughter concentration. The majority of the houses presented in this paper were monitored using a track-etch detector; some houses were tested using a filter sampling technique while the ventilation rate was determined. Close to 15% of the investigated houses have a radon daughter concentration higher than 400 Bq/m3. The majority of these houses were one-family houses. Almost 10% of this group has a concentration above 1000 Bq/m3 (0.27 WL). The results from this study show that the two most important sources for radon in buildings are building materials and the ground.  相似文献   

2.
Owners of 208 dwellings with radon daughter concentrations of 400 Bq/m3 EER or above were asked about attitudes and measures toward elimination via mailed questionnaires. The response rate was 88% and some steps toward elimination had been taken in 83 dwellings. For the remaining houses, no improvements had been made either because of financial problems, lack of technical advice, or doubts about radon daughter exposure as a health hazard. The results of this study suggest the need to more definitely assess the risk through epidemiologic studies, as well as to provide more information about technical solutions and financial support to house owners.  相似文献   

3.
Active soil ventilation techniques have been tested in 26 block-wall basement houses in eastern Pennsylvania with significantly elevated indoor radon concentrations, generally above 740 Bq/m3, and the results indicate that radon levels can be reduced substantially often below the U.S. Environmental Protection Agency (EPA) guideline of 148 Bq/m3, if effective suction can be drawn on the soil underneath the concrete slabs of these houses. Such effective suction appears achievable when either: 1) the house has a complete loop of drain tile around its footings for water drainage purposes, and suction is drawn on that loop; or 2) a sufficient number of suction pipes can be inserted at the proper locations into the crushed rock or the soil underneath the slab.  相似文献   

4.
In the UK, excessive levels of radon gas have been detected in domestic housing. Areas where 1% of existing homes were found to be over the Action Level of 200 Bq · m 3 were declared to be Radon Affected Areas. Building Regulations have been introduced which require that, for areas where between 3% and 10% of existing houses are above the Action Level, new homes should be built with basic radon protection using a membrane, and that, where 10% or more of existing homes exceed this level, new homes should be built with full radon protection.Initially these affected areas followed administrative boundaries, known as Counties. However, with increasing numbers of measurements of radon levels in domestic homes recorded in the national database, these areas have been successively refined into smaller units – 5 km grid squares in 1999, down to 1 km grid squares in 2007.One result is the identification of small areas with raised radon levels within regions where previously no problem had been identified. In addition, some parts of areas that were previously considered radon affected are now considered low, or no, risk. Our analysis suggests that the net result of improved mapping is to increase the number of affected houses. Further, the process is more complex for local builders, and inspectors, who need to work out whether radon protection in new homes is appropriate.Our group has assessed the cost-effectiveness of radon remediation programmes, and has applied this analysis to consider the cost-effectiveness of providing radon protection in both new and existing homes. This includes modelling the potential failure rate of membranes, and whether testing radon levels in new homes is appropriate. The analysis concludes that it is more cost effective to provide targeted radon protection in high radon areas, although this introduces more complexity.The paper also considers the trend in housing to a greater proportion of apartments, the regional variations in types of housing and the decreasing average number of occupants in each dwelling, and concludes that data and methods are now available to respond to the health risks of radon at a local level, in keeping with a general initiative to prioritise responses to health and social welfare issues at a more local level.  相似文献   

5.
The paper presents the results of year-long measurements of radon (222Rn) concentration inside 129 buildings in Poland in relation to the geological conditions of their foundation. The authors took into account the division of the country into tectonic units, as well as the lithology of the rocks forming the bedrock of these buildings. As expected, the highest value of mean annual 222Rn concentration (845 Bq/m3) was recorded in a building situated in the area of the Sudetes, while the highest geometric mean (characteristic of the expected log-normal data distribution) was calculated based on measurements from buildings located within the East-European craton, in the area of Mazury-Podlasie monocline, where it reached 231 Bq/m3. Such results reflect geological conditions - the occurrence of crystalline rocks (especially U- and Ra-enriched granites and orthogneisses) on the surface in the Sudetes, and of young post-glacial sediments containing fragments of Scandinavian crystalline rocks, also enriched with U and Ra, in the area of Mazury-Podlasie monocline. However, the least expected result of the investigations was finding out that, contrary to the hitherto widespread belief, none of the major tectonic units of Poland can be excluded from the list of those containing buildings with mean annual 222Rn concentration exceeding 200 Bq/m3. The mean annual concentration of radon for all the buildings were much higher than the mean concentration value (49.1 Bq/m3) of indoor radon in Poland quoted so far. These results cast a completely new light on the necessity to perform measurements of radon concentration in residential buildings in Poland, no more with reference to small areas with outcrops of crystalline rocks (especially the Sudetes, being the Polish fragment of the European Variscan belt), but for all the major tectonic units within Poland.  相似文献   

6.
Radon gas contributes a significant fraction of the natural background radiation dose, and in some areas raised levels are found in buildings. both homes and the workplace. Different UK Action Levels apply to homes and the workplace. because of the diurnal variation of radon. This study reviews the results for a number of hospitals throughout England and Wales. and suggests that the likelihood of finding raised radon levels is similar in the workplace and homes in the same area. Radon measurements and consequent remediation of any raised levels are appropriate in all workplaces in radon Affected Areas with over 5% of houses above the UK domestic Action Level of 200 Bq m(-3).  相似文献   

7.
The aim of this work was to make a comparison of indoor radon concentrations in dwellings and in soil air in the area of two geological formations in the Suwa?ki region (Poland). The mean arithmetic airborne concentration was found to be the highest (301 Bq m (-3)) in the basements of buildings in the gravel and sand areas, whereas in the boulder clay areas it reached 587 Bq m (-3). Out of 54 measurements of radon concentrations performed at the ground floor, in eight cases concentrations were found to exceed 200 Bq m (-3) - permissible radon level in new-built houses in Poland and in three cases these values were even higher than 400 Bq m (-3). The highest radon levels were noted in houses with earthen basement floors and with direct entrance from the basement to rooms or kitchens. The mean arithmetic radon concentration in the soil air in the sandy and gravel formations was 39.7 kBq m (-3) and in clay formation it was 26.5 kBq m (-3). Higher radon levels were also found in the water obtained from household wells reaching 8367 Bq m (-3) as compared with tap water (2690 Bqm (-3)). The mean indoor concentration for the whole area under study was found to be 169.4 Bq m (-3), which is higher than the mean value for Poland (49.1 Bq m (-3)) by a factor of 3.5.  相似文献   

8.
Monitoring of radon, thoron and their daughter products was carried out in houses of Kumaun Himalaya, India using LR-115 plastic track detectors. The measurements were made in residential houses from June 1999 to May 2000 at a height of 2.5 m from ground level using a twin chamber radon dosimeter. The twin chamber radon dosimeter can record the values of radon, thoron and their decay products separately. Maximum and minimum indoor radon and thoron concentrations were evaluated and activity concentrations of radon and thoron daughters were estimated. The resulting dose rates due to radon, thoron and their decay products varied from 0.04 to 1.89 microSv/h. A detailed analysis of the distribution of radon, thoron and their decay products inside the house is also reported. The observed dose rates inside the houses of Kumaun Himalaya were found to be lower than the ICRP recommended value of 200 Bq/m3 and thus are within safe limits.  相似文献   

9.
A radon survey has been carried out around the town of Niska Banja (Serbia) in a region partly located over travertine formations, showing an enhanced level of natural radioactivity. Outdoor and indoor radon concentrations were measured seasonally over the whole year, using CR-39 diffusion type radon detectors. Outdoor measurements were performed at 56 points distributed over both travertine and alluvium sediment formations. Indoor radon concentrations were measured in 102 living rooms and bedrooms of 65 family houses. In about 50% of all measurement sites, radon concentration was measured over each season separately, making it possible to estimate seasonal variations, which were then used to correct values measured over different periods, and to estimate annual values. The average annual indoor radon concentration was estimated at over 1500 Bq/m3 and at about 650 Bq/m3 in parts of Niska Banja located over travertine and alluvium sediment formations, respectively, with maximum values exceeding 6000 Bq/m3. The average value of outdoor annual radon concentration was 57 Bq/m3, with a maximum value of 168 Bq/m3. The high values of indoor and outdoor radon concentrations found at Niska Banja make this region a high natural background radiation area. Statistical analysis of our data confirms that the level of indoor radon concentration depends primarily on the underlying soil and building characteristics.  相似文献   

10.
To quantify the effectiveness of Sub-Slab Depressurisation, widely used in the United Kingdom (U.K.) to mitigate indoor radon gas levels in residential properties, a study was made of radon concentration data collected from a set of 170 homes situated in Radon Affected Areas in Northamptonshire and neighbouring counties, remediated using conventional sump/pump technology. A high incidence of satisfactory remediation outcomes was achieved, with 100% of the houses remediated demonstrating post-remediation radon concentrations below the U.K. domestic Action Level of 200 Bq m(-3), while more than 75% of the sample exhibited radon mitigation factors (defined as the ratio of radon concentrations following and prior to remediation) <0.2. Two systematic trends are identified. Firstly, absolute radon concentration reduction following remediation is directly proportional to initial radon concentration, with a mean reduction factor of 0.96 and a residual component of around 75 Bq m(-3). Secondly, houses with lower initial radon concentrations demonstrate poorer (higher) mitigation factors. These observations support a model in which the total indoor radon concentration within a dwelling can be represented by two principal components, one susceptible to mitigation by sub-slab depressurisation, the other remaining essentially unaffected. The first component can be identified with radon emanating from the subsoil and bedrock geologies, percolating through the foundations of the dwelling as a component of the soil-gas, and potentially capable of being attenuated by sub-slab depressurisation or radon-barrier remediation technologies. The second contribution can be identified with radon emanating from materials used in the construction of the dwelling with a further contribution from the natural background level, and is essentially unaffected by ground-level remediation strategies. Modelling of a multi-component radon dependency using ground-radon attenuation factors derived from the experimental data, in conjunction with typical background and structural-radon levels, yields behaviour in good agreement with the observed dependence of mitigation factor on initial radon concentration.  相似文献   

11.
The aim of the study was to compare radon concentrations in neighbouring hospital buildings which were constructed in different years during the period 1963-2000 and are located in areas with similar radon potential. The value of arithmetic mean (AM) radon concentration in soil gas amounted to 14,464 Bq m(-3). In a hospital built 40 years ago, the AM radon concentration in the cellar was 38.4+/-36.7 Bq m(-3) and on higher levels it was 17.1+/-10.3 Bq m(-3). In a hospital built 16 years ago, these values equaled 45.5+/-47.2 Bq m(-3) and 20.4+/-12.5 Bq m(-3), respectively. In the newest hospital, built three years ago, radon concentration (AM) in a cellar was 32.3+/-27.4 Bq m(-3) and the respective value on higher levels amounted to 20.4+/-12.6 Bq m(-3). When comparing radon concentrations in the cellars, no statistically significant differences were found. Similarly, no statistically significant differences were observed between radon concentrations measured on higher levels in investigated hospital buildings.  相似文献   

12.
Measurements of indoor radon concentrations were performed in 28 low-rise houses and 30 apartments in Patras area from December 1996 to November 1997, using nuclear track detectors. The investigation was focused on the effects of season and floor number, as well as on the existence of a basement in low-rise houses on indoor radon levels. It was found that the differences in mean radon concentrations between adjacent seasons, in a number of 61 selected sampling sites distributed in 28 houses, were statistically significant. As expected, a maximum was found in winter and a minimum in summer. The differences in mean radon concentration on different floors of the same houses were also statistically significant and followed a linear decrease from underground to 2nd floor. In addition, indoor radon concentrations in the ground floor were found to be influenced by the existence or not of a basement. The average annual radon concentration was found to be 41 Bq m(-3) for the houses, 28 Bq m(-3) for the apartments and 38 Bq m(-3) for all the dwellings. These values lead to an average effective dose equivalent of 1.1, 0.7 and 0.9 mSv y(-1), respectively. Residents living on the underground in low-rise houses, during winter, where the average effective dose equivalent is 2.1 mSv y(-1), attain the higher risk.  相似文献   

13.
Radon and gamma dose rate measurements were performed in 512 schools in 8 of the 13 regions of Greece. The distribution of radon concentration was well described by a lognormal distribution. Most (86%) of the radon concentrations were between 60 and 250 Bq m−3 with a most probable value of 135 Bq m−3. The arithmetic and geometric means of the radon concentration are 149 Bq m−3 and 126 Bq m−3 respectively. The maximum measured radon gas concentration was 958 Bq m−3. As expected, no correlation between radon gas concentration and indoor gamma dose rate was observed. However, if only mean values for each region are considered, a linear correlation between radon gas concentration and gamma dose rate is apparent. Despite the fact that the results of radon concentration in schools cannot be applied directly for the estimation of radon concentration in homes, the results of the present survey indicate that it is desirable to perform an extended survey of indoor radon in homes for at least one region in Northern Greece.  相似文献   

14.
In this paper, a simple model for analysing variability in radon concentrations in homes is tested. The approach used here involves two error components, representing additive and multiplicative errors, together with variation between-houses. We use a Bayesian approach for our analysis and apply this model to two datasets of repeat radon measurements in homes; one based on 3-month long measurements for which the original measurements were close to the current UK Radon Action Level (200 Bq m−3), and the other based on 6-month measurement data (from regional and national surveys), for which the original measurements cover a wide range of radon concentrations, down to very low levels. The model with two error components provides a better fit to these datasets than does a model based on solely multiplicative errors.  相似文献   

15.
Domestic radon levels in parts of the United Kingdom are sufficiently high as to increase the risk of lung-cancer among residents. Public health campaigns in the county of Northamptonshire, a designated radon Affected Area with 6.3% of homes having average radon levels in excess of the UK Action Level of 200 Bq m(-3), have encouraged householders to test for radon and then, if indicated to be necessary, to carry out remediation in their homes. These campaigns have been only partially successful, since to date only 40% of Northamptonshire houses have been tested, and only 15% of those householders finding raised levels have proceeded to remediate. Those who remediate have been shown to have smaller families, to be older, and to include fewer smokers than the average population, suggesting that current strategies to reduce domestic radon exposure are not reaching those most at risk. During 2004-2005, the NHS Stop-Smoking Services in Northamptonshire assisted 2847 smokers to quit to the 4-week stage, the 15% (435) of these 4-week quitters remaining quitters at 1year forming the subjects of a retrospective study considering whether smoking cessation campaigns contribute significantly to radon risk reduction. Quantitative assessment of the risk of lung-cancer among the study population, from knowledge of the individuals' age, gender, and smoking habits, together with the radon levels in their homes, demonstrates that smoking cessation programmes have significant added value in reducing the incidence of lung-cancer in radon Affected Areas, and contribute a substantially greater health benefit at a lower cost than the alternative strategy of reducing radon levels in the smokers' homes, while they remain smokers. Both radon remediation and smoking cessation programmes are very cost effective in Northamptonshire, with smoking cessation being significantly more cost effective, and these are potentially valuable programmes to drive health improvements through promotion of the uptake or environmental management for radon in the home.  相似文献   

16.
High-resolution gamma spectrometry was used to determine the concentration of 40K, 238U and 232Th series in soil samples taken from areas surrounding the city of Aldama, in Chihuahua. Results of indoor air short-time sampling, with diffusion barrier charcoal detectors, revealed relatively high indoor radon levels, ranging from 29 to 422 Bq/m3; the radon concentrations detected exceeded 148 Bq/m3 in 76% of the homes tested. Additionally, liquid scintillation counting showed concentrations of radon in drinking water ranging from 4.3 to 42 kBq/m3. The high activity of 238U in soil found in some places may be a result of the uranium milling process performed 20 years ago in the area. High radon concentrations indoor and in water may be explained by assuming the presence of uranium-bearing rocks underneath of the city, similar to a felsic dike located near Aldama. The estimated annual effective dose of gamma radiation from the soil and radon inhalation was 3.83 mSv.  相似文献   

17.
Two studies evaluating the levels and sources of nitrogen dioxide in approximately 90 employee homes in the Richmond area with continuous sampling during the weeks of August 5, 1980, and February 9, 1981, were performed using samplers in the living room, bedroom, kitchen, and outdoors. Additional data were collected concerning appliance usage, heating/cooling plant, ventilation and cigarette smoking. Results were analyzed using BMDP routines. The largest contributor to NO2 concentration was found to be gas-fired kitchen appliances. The mean kitchen level for homes with gas appliances during the winter study was 188 μg/m3. Excluding participants with gas kitchens, incremental influence due to cigarette smoking was detected. The 7-day, 3-room average level of NO2 in the homes of nonsmokers and smokers without gas-fired appliances was 12 and 15 μg/m3, respectively, in the summer. The corresponding winter values were 19 and 22 μg/m3. Furthermore, the individual levels of NO2 in the homes of smokers were generally below both the adjacent outdoor level and the National Ambient Air Quality Standard limit for annual exposure.  相似文献   

18.
This paper reports on radon concentrations in dwellings from fifty different locations of India. The incorporated data were obtained using the passive solid state nuclear track detector technique. The estimated geometric mean value for India is 67.1 Bq m(-3). Chuadanga in Bangladesh had the lowest observed indoor radon concentration of 27.3 Bq m(-3) and Una in the northern part of India had the highest concentration of 281.5 Bq m(-3). This paper discusses the national geometrical mean value in terms of the national geometric mean values of other countries and also in terms of the geological influence. The estimated indoor radon levels are compared with the indoor radon levels as recommended by the International Commission on Radiation Protection (ICRP). It was observed that there are several locations in India where dwellings have higher indoor radon levels than the ICRP recommended value and requires some sort of intervention from regulating authorities. The mean value for indoor radon level given in the report of UNSCEAR 2000 for India needs to be revised.  相似文献   

19.
The indoor air of 60 residences in and around a Maryland suburb of Washington, DC, was monitored in a pilot study to determine residential radon concentrations. In each residence, a radon grab sample was acquired in the living room, and, if possible, in the basement. Infiltration rates were determined by tracer gas dilution. To help standardize sampling conditions, each home remained closed up for 8 h prior to sampling and during analysis. Over 60% of the residences sampled showed air infiltration rates below 0.6 air changes per hour. Approximately 55% of all surveyed basements and 30% of all surveyed living areas displayed radon concentrations in excess of 4.0 nCi m−3. Assuming an equilibrium factor of 0.5, these radon levels may lead to working levels above the annual guidelines suggested by EPA for florida homes build on land reclaimed from phosphate mining.  相似文献   

20.
The aim of this paper was to study the variations of radon and daughter nuclei during treatment in the thermal spas of Lesvos Island (Greece). For this purpose, in the thermal spas of Lesvos we have measured the radon concentrations of thermal waters, as well as indoor radon, daughter and coarse particle (>500 nm) concentrations. Various instruments and procedures were employed for measurements. Radon concentrations of thermal waters were found to lie in the range 10 Bq l(-1) and 304 Bq l(-1). Concentration peaks both for radon, radon daughter and coarse particle, were found to appear during filling of baths in the treatment process. The doses delivered to the bathers during treatment were in the range of 0.00670-0.1279 mSv per year, while the doses delivered to personnel were below 20 mSv per year.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏