首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper addressed the performance of single flash combined with a binary system that was proposed in the Dieng geothermal power plant by applying thermodynamic assessment methods. A set of mathematical equations from the plant was developed and solved iteratively using engineering equation solver. The results showed that the available exergy of the produced fluid from production wells is 66,204 kW. The performance of an existing single-flash power plant indicated 24,300 kW of net power output. The proposed design of single flash combined with a binary system improves the power output by 17.16% to 27,786 kW. The second law efficiency increases from 36.7% to 41.97% while the first law efficiency increases from 11.62% to 13.61%.  相似文献   

2.
In this paper, performance of a solar hybrid adsorption refrigeration (AR) system is investigated experimentally. Such a system was built and tested under the conditions at National Institute of Technology Calicut, Kerala, India. The hybrid system has been designed for heating 50 l of water from 25 to 90°C as well as cooling 10 l of water from 25 to 10°C. The experimental results demonstrate that the refrigerator has a cooling capacity of 47–78 W with a cycle coefficient of performance (COP) of 0.19 and maximum possible COP of 0.45. In exergy analysis of the system, the irreversibility and exergetic efficiency of each component of the system have been calculated. The exergy analysis reveals that the main source of irreversibility is the adsorbent bed of the AR system, emphasising that the input heat energy is not utilised efficiently due to material constraints. The exergetic efficiencies of condenser, expansion device, evaporator and adsorbent bed are found as 42.3%, 79.8%, 54.7% and 11%, respectively.  相似文献   

3.
Hybrid energy systems are renewable energy system combined in a complementary fashion to ensure dependable power supply at competitive cost. Diesel generators (DGs) are also added here as a back-up source of supply. For remote areas far from a transmission grid, these systems can provide a reliable and cost-effective supply. Addition of DG could instigate environmental pollution in such remote unpolluted areas. In the present work, optimal sizing of hybrid energy system has been attempted for a remote village cluster of Uttarakhand (India) to make available desired power supply at minimum environmental effluence. Hybrid Optimization Model for Electrical Renewable (HOMER) software from National Renewable Energy Laboratory, USA has been employed to attain the objective. The software offered several feasible systems, ranked on the basis of net present cost (NPC). All such systems are further analysed for emissions they have made in the environment. Hence, the optimal system fulfilling the criteria of minimal environmental degradation with sufficiently minimum NPC has been searched for. In the present work, the most appropriate system offered on the basis of NPC is the one which has five wind turbines (10 kW each), one DG (65 kW) and 25 batteries (6 V, 6.94 kW h each). The NPC of the system is $1,252,018, whereas its initial capital cost and levelised cost of energy (COE) are $94,233 and $0.292/kW h, respectively. After further analysis of all the feasible systems on the basis of environmental effluence, the most feasible system explored is the one which has minimal emissions of various pollutants such as carbon dioxide, carbon monoxide, hydrocarbon, particulate matter, sulphur dioxide and nitrous oxide. The system has been obtained on a compromised NPC of $1,270,921 with a capital cost of $148,133 and COE of $0.296/kW h. Components of the system include five wind turbines (10 kW), a 9 kW PV panel and a 65 kW DG along with 30 batteries (6 V, 6.94 kW h each). The system so obtained would prove to be a feasible, optimally sized and sustainable power supply alternative for remote unelectrified hilly rural area.  相似文献   

4.
Earth-air heat exchangers (EAHE) are devices used in the geothermal technique in order to reduce energy consumption in buildings. In this study, a simulation was conducted through the computational fluid dynamics platform FLUENT 6.3 for the prediction of thermal performance of the EAHE that describes the variation of the air temperature inside the tube. For this, it was necessary to design the heat exchanger while respecting the design and the actual dimensions of the experimental set-up, and stating that the temperature of the wall of the horizontal tube of the exchanger is equal to that of ground at 3 m depth. It should be noted that in assessing the temperature along the two sections vertical (input and output) of the exchanger, opting for a function (UDF) the user define function. Finally, noting a good agreement between both experimental and numerical study, and showing that a significant reduction in temperature at the outlet of the exchanger to a difference of 20 °C, confirming the effectiveness of the heat exchanger.  相似文献   

5.
A modified brushed permanent magnet DC (PMDC) motor has been developed and fabricated for a photovoltaic (PV)-operated solar systems. The conventional PMDC motor has been plagued with constraints, the most critical being ingestion of vapours of working fluid inside the rotor and stator, damaging the insulation of windings and forming a thin film of moisture between commutator and brushes. This flaw results into a very low mean time between failures of the motor. In the past, many attempts have been made where-in variety of seals to isolate the working fluid vapours from inner parts of motor have been tried out, but to no avail. Even Brushless DC motors have been designed in the past but their exorbitant cost makes the entire arrangement not viable economically. The modification attempted in this article overcomes the problem of working fluid ingestion inside the motor. It is found that mass flow rate of working fluid obtained at maximum peak sunshine hours is 17.5 l/min at 3030 rpm of motor driven by a PV module of 40 W at 16.20 V. This low-cost modified PMDC motor has been robust with high mean time between failures as no breakdown observed during 18 months of operation.  相似文献   

6.
The recent increase in energy costs, driven by a surge in oil prices, has increased world‐wide efforts on the exploitation of renewable/wind energy resources for environment‐friendly sustainable development and to mitigate future energy challenges. Moreover, experience in the wind energy industry has reached high levels in the field of manufacturing and application. This inevitably increases the merits of wind energy exploitation. In order to exploit wind resources, through the establishment of wind power plants, specific attention must be focused on the characteristics of wind and wind machines. The literature indicates that wind‐energy resources are relatively better along coastlines. In the present study, long‐term hourly mean wind speed data for the period 1986–2003, recorded at Dhahran (Eastern Coastal region, Saudi Arabia), has been analysed to examine the wind characteristics including (but not limited to): yearly/monthly/diurnal variations of wind speed, frequency distribution of wind speed, impact of hub‐height/machine‐size on energy production, etc. Data have been checked/validated for completeness. Data analysis indicated that long‐term monthly average wind speeds ranged from 3.8 to 5.8 m/s.

Concurrently, the study determined monthly average daily energy generation from different sizes of commercial wind machines (150, 250, 600 kW, etc.) to assess the impact of wind machine size on energy yield. The study also estimated annual energy production (MWh/year) from wind farms of different capacities (3, 6, 12, 24 MW, etc.) by utilising different commercial wind energy conversion systems (WECS). It was observed that, for a given 6 MW wind farm size, a cluster of 150 kW wind machines (at 50 m hub‐height) yielded about 32% more energy when compared to a cluster of 600 kW wind machines. The study also estimated the cost of wind‐based electricity (COE, US$/kWh) by using different capacities of commercial WECS. It was found that the COE per kWh is 0.045 US$/kWh for 150 kW wind machine (at 50 m hub‐height) whereas COE was 0.039 US$/kWh for 600 kW wind machine (at 50 m hub‐height). The study also dealt with wind turbine characteristics (such as capacity factor and availability factor). These characteristics are important indicators of wind turbine performance evaluation.  相似文献   

7.
The regulations of process efficiency and stricter environmental policies require analysis of large-scale thermal energy systems to produce highly efficient, cost effective and low environmental impact energy. For analysis, it is beneficial to simulate an energy system. In this paper, simulation models are developed for the analysis of a combined cycle heat and power plant located in Göteborg, Sweden. With the help of simulation models, characteristics between district heating (DH) water temperature and key parameters such as overall district heat duty, electrical power and electrical efficiency has been developed. The characteristics are useful to estimate and maximize the key parameters during varying DH water temperature. According to a comparison between the full-load simulation models of 2006 and 2013 for the selected power plant, a loss of 2 MW is noticed for gas turbine and a loss of 2.18 MW of heat flow occurs for heat recovery steam generator in the year 2013. The feasibility analysis of modifying the connection between DH economizer and main DH line provides good performance indicators in a winter scenario. The conclusions in this paper are good references to plan and improve the performance of existing large-scale thermal power plants.  相似文献   

8.
The potential of harvesting heat energy from asphalt pavement using a piping network with fluid flowing through it needs to be evaluated before spending a significant amount of time on planning details of design and construction. The key factors involved in this evaluation include the temperature of the pavement at the depth at which the system is being considered, as well as the temperature of the fluid used for harvesting the heat energy. Costs include those required for the system such as pumps and pipes, and cost of energy required for pumping. Taking all of the factors into consideration, a macro-enabled spreadsheet has been developed that allows the user to input air temperature data as well as pipe location and cost parameters. The end results are data on flow rate versus yearly savings and payback period. From these data, a user can easily determine whether the payback period is reasonable or not and could also evaluate the effect of the different parameters on the payback period. Examples of the results of analysis for different cities in four different parts of the USA and Singapore and Chennai, India, are presented. The payback period shows a good relationship with the latitude of the location – the period increases with an increase in latitude. The public domain location from where the spreadsheet can be downloaded is provided.  相似文献   

9.
Fuelwood is one of the major sources of energy in the domestic sector across the rural areas, especially in the developing regions across the world. The Northeastern Himalayan state of Manipur is dominated by the tribal population that largely depends on fuelwood from the nearby forest area. The entire dependence on forests for energy resources is affecting the sustainability of the forest ecosystem in the region, thus indicating the livelihood conditions. Since land-use land-cover change is the key driver to the change in resource availability of a region, the present study has tried to analyze the land-cover changes over a period 28 years. The second major component affecting resource availability is the increasing population pressure that leads to changes in the land dynamics, which directly affect the resource production. Based on the existing consumption pattern, the total consumption of fuelwood in the watershed ranges from a minimum of 289.992 tons/year to a maximum of 3545.719 tons/year with an average of 1561.956 tons/year in the year 2009 and simulated fuelwood consumption for the year 2021 is around 1469.260 tons/year. Nine different probable scenarios of resource are proposed to calculate the stress value that can be used by the policy-makers and planners for suitable policy implementation at the micro level with a complex social system.  相似文献   

10.
The world is facing an energy and climate crisis. Globally, the energy sector emits 26 billion tonnes of CO2 each year, and electricity production alone accounts for 41% of emissions (European Wind Energy Association. 2008. Pure Power: Wind Energy Scenarios up to 2030. European Wind Energy Association. p. 6). Currently, reducing CO2 emissions and curbing climate change have become global priorities, and we only have a narrow window of time left in which to act. The new type of refrigerator can offer an immediate and concrete solution to the many energy and climate challenges that we are facing. This is an account of a new type of refrigerator and its cycle for use in the refrigeration industry. For its cycle, the working substance is air or other gases; its cycle is very similar to that of the reverse Brayton cycle (Hou, Y., Zhao, H. L., Chen, C. Z., and Xiong, L. Y. 2006. “Developments in Reverse Brayton Cycle Cryocooler in China.” Cryogenics 46 (5): 403–407). In the cycle of the new type of refrigerator, the isochoric exothermic process and the isothermal exothermic compression process replace the isobaric exothermic compression process of the reverse Brayton cycle. The new type of refrigerator can produce a net electrical energy, and it is not a perpetual motion machine, because the environmental enthalpy and atmospheric pressure can be utilized as the external energy sources, which cannot be performed by any other conventional refrigerators; therefore, the reliability and significance of this new type of refrigerator is self-evident.  相似文献   

11.
The thermal performances of an evacuated tube collector (ETC) and flat-plate solar air collector (FPC) are experimentally investigated at different air flow rates. To investigate the performance of the ETC and FPC, experimental set-ups were fabricated. Air was used as a working fluid and tested at the same climatic conditions. The ETC had 15 evacuated tubes with a surface area of 1.66 m2. The experimental set-up consisted of a header with a hollow pipe (square pipe) in the centre through which the air flowed. The flat-plate collector had a surface area of 1.35 m2. The FPC had a black painted absorber sheet which divides the collector into two sections. The air flowed through the upper and the lower sections parallel to the collector to minimize the overall heat loss. The temperature of the outlet air depends on several factors along with the airflow rate and the intensity of the solar radiation. It was found that during the day at high flow rates, the efficiency of the ETC varies from 0.12 to 0.5, and for the flat plate it was from 0.29 to 0.68. The maximum temperature of the air was 56.7°C for the ETC and 25.7°C for the FPC.  相似文献   

12.
This paper compared the life cycle inventory (LCI) obtained from three commercial oil palm biomass composting projects in Malaysia which use the open windrow composting system. The LCI was obtained and calculated based on the functional unit of 1 t of compost produced. The input of the inventory are the feed materials such as empty fruit bunches (EFB) and palm oil mill effluent (POME); and utilities which include electricity generated at palm oil mill and diesel used. Composting 2.0–2.5 t of EFB and 5.0–7.5 t of POME required diesel from 218.7 to 270.2 MJ and electricity from 0 to 6.8 MJ. It is estimated that the composting emitted from 0.01 to 0.02 t CO2eq/tcompost mainly from diesel used to operate machineries. Composting saved 65 % of time required for a complete degradation of POME when compared to ponding system, and 89 % of time required for a complete degradation of EFB compared to mulching. In terms of land required, it required 36 % less land as compared to ponding for POME and 99 % less land as compared to mulching for EFB. Based on the case study, diesel was found to be the main contributor to the environmental impact. There is a potential of upgrading the process to be more economical and environmental friendly. Using electricity as the source of energy has a lower footprint for the composting process. Instead of using raw POME, studies had reported that using treated POME either from anaerobic ponding or digested tank can accelerate the composting process.  相似文献   

13.
Packaging is strictly connected to environmental issues as it is a product characterised by high material consumption rate; it is often transported over long distances and has a short life. Providing environmental analysis is, therefore, urgent to identify energy and resources efficient solutions. The paper, taking advantage of a real case study, presents a life cycle-based comparative analysis among three different food packaging systems. The paper compares the life cycle of tin steel, polypropylene and glass-based packaging of an Italian preserves producer. The analysis leads to the conclusion that, for the baseline scenario, polypropylene packaging represents the greenest solution, whereas glass packaging is the worst choice. The paper presents a scenario analysis varying both the method used for accounting for recycling as well as the recycling rates of the packaging materials. Changes in overall results with parameters analysis changing are calculated and highlighted throughout the paper. The impact of a reuse policy of the glass-based solution is also analysed; a model for disposable glass packaging is proposed and the obtained results are compared with the single use polypropylene and tin steel-based packaging. In order to analyse the impact of different End of Life scenarios on the present case study, collecting as well as recycling rates of some European countries have been used. The results revealed a significant fluctuation both in energy consumption and in CO2 emission as the nation changes. Summing up, a methodology for packaging environmental impact analysis is applied to a real case study, some crucial aspects of the methodology have been analysed in depth in order to give a contribution in packaging environmental impact analysis.  相似文献   

14.
中国农村可再生能源的发展现状分析   总被引:1,自引:0,他引:1  
中国有9亿人民生活在农村地区,农村能源的利用直接影响我国经济社会的全面发展,本文首先介绍了我国的能源资源潜力及农村能源消费结构,指出现阶段正处于从传统能源消费结构向现代能源消费结构变迁的过程中。在分析我国各种可再生能源技术最新发展现状基础上,文中总结了可再生能源CDM碳交易项目的进展,最后分析了我国给与可再生能源发展的鼓励及相关保护政策并提出了了我国农村可再生能源发展的问题及建议。  相似文献   

15.
The present work seeks to assess the sustainability of different solar photovoltaic (SPV) electricity-generating systems based upon energy, environment and economics. The sustainability indicators evaluated for energy, environment and economics are electrical output, life-cycle greenhouse gas (GHG) emissions and life-cycle cost of electricity generated per kilowatt hour. The selected SPV-based electricity generation technologies for sustainability evaluation are amorphous, monocrystalline and polycrystalline at different locations and tilt angles across India. For SPV systems, most of the emissions are the result of electricity use during manufacturing. In these cases, an average grid mix for the region of manufacture is typically used to calculate energy use and emissions. Based upon these three indicators, a figure of merit (FM) has been proposed. The results proposed that polycrystalline gives the maximum electrical output, minimum GHG emission, minimum cost and maximum FM at a radiation level of 6 kWh/m2/day with latitude and tilt angle of 34° and 35°, respectively. This work will be helpful to users of solar energy, academicians, researchers and other concerned persons, in understanding the importance, severity and benefits obtained by the application and implementation of the SPV electricity-generating systems.  相似文献   

16.
This paper reports a performance analysis for a new sustainable engineering application to beneficially reuse an abundant agricultural waste, coconut coir (Cocos nucifera), in evaporative cooling pads. Two small coconut coir pads of different configurations were fabricated and tested using a laboratory‐scale experimental arrangement. The air supply velocity was controlled and varied between 1.88 and 2.79 m s?1. Heat and mass transfer coefficients, evaporative cooling efficiency and pressure drop across the two types of coconut coir pad were analysed and compared with those of a commercial rigid media paper pad. Results show that the cooling efficiency of the manufactured coconut coir evaporative cooling pad was fairly good (about 50%) and close to that of the commercial paper pad (about 47%). The average pressure drop across the two coconut coir pads was 1.5 and 5.1 Pa respectively. Correlations for heat and mass transfer coefficients expressed using Nusselt and Sherwood numbers are also reported. In addition, the cooling potential of the coconut coir pads was analysed using the average climatic conditions of the central region in Thailand throughout the year. The analysis showed that the air temperature leaving the coconut coir pad varied from 23 to 28°C. Commercial development appears feasible given the coconut coir pad's good performance, lower cost and its availability throughout the country.  相似文献   

17.
The objective of this paper is to analyse the impacts of climate change on a pine forest stand in Central Siberia (Zotino) to assess benefits and risks for such forests in the future. We use the regional statistical climate model STARS to develop a set of climate change scenarios assuming a temperature increase by mid-century of 1, 2, 3 and 4 K. The process-based forest growth model 4C is applied to a 200-year-old pine forest to analyse impacts on carbon and water balance as well as the risk of fire under these climate change scenarios. The climate scenarios indicate precipitation increases mainly during winter and decreases during summer with increasing temperature trend. They cause rising forest productivity up to about 20 % in spite of increasing respiration losses. At the same time, the water-use efficiency increases slightly from 2.0 g C l?1 H2O under current climate to 2.1 g C l?1 H2O under 4 K scenario indicating that higher water losses from increasing evapotranspiration do not appear to lead to water limitations for the productivity at this site. The simulated actual evaporation increases by up to 32 %, but the climatic water balance decreases by up to 20 % with increasing temperature trend. In contrast, the risk of fire indicated by the Nesterov index clearly increases. Our analysis confirms increasing productivity of the boreal pine stand but also highlights increasing drought stress and risks from abiotic disturbances which could cancel out productivity gains.  相似文献   

18.
ABSTRACT

This work deals with the optimization of an hybrid energy system used to supply an isolated site. The proposed system combines a wind turbine, a photovoltaic panel, a diesel generator and a battery bank to electrify atypical home. An energy cost-effectiveness approach is adopted in accordance with meteorological data, time profile of energy consumption, and the cost of different alternative systems. A variety of performances is obtained through simulations within the Homer Pro environment. The selection of an optimal combination is based on the maximum integration of renewable energy in the suggested system with a minimum of gas emission. According to the obtained results, the overall cost of the selected installation is about 72,900 €, with 0.415€ the unit cost of a kWh electric energy provided with a contribution of renewable energy of around 86%. Simulations show a technical and financial benefits of the different configurations obtained to supply the target site. To control the proposed hybrid energy system, a supervision algorithm is developed and implemented on TMS320F28027 DSP platform. The proposed energy system aims to take advantages of renewable energy sources and shift to conventional sources only when necessary in order to ensure source autonomy and service continuity.  相似文献   

19.
This study presents an integrated hydrologic–economic model as decision support system for groundwater use and incorporates uncertainties of climate change. The model was developed with the Vensim software (Ventana Systems) for system dynamic simulations. The software permitted the integration of economic variables along with hydrologic variables, in a unified format with the aim of evaluating the economic impacts of climate change on arid environments. To test the model, we applied it in one of the upper Tunuyán River sub-basin, located in the Mendoza Province (Argentina), where irrigation comes from groundwater. The model defines the best mix of crops and the total land use required to maximize the total river sub-basin monetary income, considering as a limit the amount of water that does not exceed the natural annual aquifer recharge. To estimate the impacts of climatic changes, four scenarios were compared: the business as usual (with the number of existing wells) in a dry year with a temperature increase of 4 °C; the business as usual in a wet year with an increase in temperature of 1.1 °C; an efficient use of wells in a dry year and a temperature increase of 4 °C and an efficient use of wells in a wet year with a temperature increase of 1.1 °C. Outputs calculated by the model were: land use per crop, total sub-basin net benefit, total sub-basin water extraction, water extraction limit depending on river discharge and total number of wells required to irrigate the entire area. Preliminary results showed that the number of existing wells exceeded the optimized number of wells required to sustainably irrigate the entire river sub-basin. Results indicated that in an average river discharge year, if wells were efficiently used, further rural development would be possible, until the limit of 350 million m3 of water extraction per year was reached (650 million m3 for a wet year and 180 million m3 for a dry year). The unified format and the low cost of the software license make the model a useful tool for Water Resources Management Institutions, particularly in developing countries.  相似文献   

20.
The cement industry is one of the most energy-intensive industries consuming 4 GJ/ton of cement, i.e. 12–15% of the energy use in total industry. Energy cost accounts for 30% of the total cost of cement production. Seventy-five per cent of this energy is due to the thermal energy for clinker production. It is also found that 35% of this supplied thermal energy is lost in flue gas streams. Most modern kilns use pet coke or coal as their primary fuel. Instead, the municipal waste in landfills offer a cheap source of energy and reduce the environmental effects of dumping solid waste. The calcination and drying processes and the kiln need large quantities of thermal energy. About 40% of the total energy input is lost in the hot flue gases and cooling the stack plus the kiln shell. Hence, it is suitable to use an organic Rankine cycle (ORC) to recover the exhaust energy from the kiln. Alternatively, a 15 MW gas turbine engine combined with a steam turbine could be utilized. It was found that ORC produces 5 MW with a capital cost recovery period of 1.26 years. However, the gas turbine combined system produces 21.45 MW with a maximum recovery period of 2.66 years.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号