首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
A standardized questionnaire was used in a two-year follow-up study to test the effectiveness of non-regulatory recommendations to improve indoor air quality of 103 ice arenas in Finland. In addition, the performance of a state-of-the-art emission control technology (ECT) on propane-fueled resurfacers was evaluated by measuring the one-week average nitrogen dioxide (NO2) concentration in a small sample of arenas. The number of retrofitted ECT on propane-fueled resurfacers increased from 6 to 37 (8% to 37% of ice arenas) and the number of electric resurfacers from 7 to 9 (both 9% of arenas) in 1994–1996. At the same time, the prevalence of inadequate ventilation increased among the most susceptible small arenas (volume <30 000 m3) from 11 (31%) to 19 (38%). Combustion-powered resurfacers (88%) and inadequate ventilation (24%) were prevalent also among the 17 new arenas built in 1994–1996. ECT resurfacers significantly decreased the mean indoor NO2 concentration of eleven arenas from 650 μg/m3 to 147 μg/m3. Thus, retrofitting resurfacers with ECT seems to be a feasible mitigation option to improve indoor air quality in ice arenas, but the ultimate solution is an electric ice resurfacer. Non-regulatory recommendations seem to be partially effective in abatement against the air quality problems, but additional regulatory measures are needed for full compliance in all arenas.  相似文献   

2.
选取2014~2017年南昌市不同时间尺度AQI及主要空气污染物数据,利用GIS技术、神经网络分析、后向轨迹模型及地统计分析方法,分析了南昌市环境空气污染时空变化特征及影响因素。结果表明,南昌市近年来空气质量总体变化不大,空气质量等级以良为主,占全年比例为57%~61%。但首要污染物变化较大,即PM2.5比例显著下降,NO2和O3比例显著上升,PM10变化不大。南昌市空气污染季节变化显著,冬春季空气质量较差,以PM10、PM2.5污染为主,夏季空气质量最好,以O3污染为主。空气污染周变化以周末及周一污染较重、周四污染最轻,说明南昌市空气污染除了与群众出行习惯有关,还存在其他影响因素。南昌市空气质量日变化呈双峰型(9:00~11:00和20:00~22:00),主要受上、下班高峰期带来的交通尾气影响。南昌市空气污染空间变化呈典型的“郊区-市区”分布,其中AQI、PM10、PM2.5、SO2、NO2、CO值均以市区较高、郊区较低,而O3的空间分布规律正好相反,这主要与城区NOx排放较多,O3易与其迅速反应而消耗有关。后向轨迹聚类分析结果表明,来自本地的短轨迹气团占比高,对PM2.5、PM10、NO2、O3的影响大。气象因素上,PM2.5、PM10、NO2受相对湿度影响较大,O3受温度影响较大。  相似文献   

3.
贵阳市主城区空气质量指数时空分布特征   总被引:1,自引:0,他引:1  
为了解贵阳市主城区空气质量指数的时间分布和空间分布特征,采用时间序列法和插值法统计分析了2013~2015年贵阳市9个空气自动监测点SO2、NO2、PM10、PM25、CO的监测数据。结果表明:2013~2015年期间,贵阳市主城区空气质量整体良好,优于Ⅱ级空气质量标准,IAQISO2、IAQINO2、IAQIPM10、IAQIPM25、IAQICO的年均值呈现降低趋势, 空气污染物得到一定的控制;季节变化和月变化分析表现出冬季空气质量最差,夏季最好的特征。春节半月ISO2、IAQINO2、IAQIPM10、IAQIPM25的均值好于冬季均值,反映了工业和交通污染源的主控作用。空间分布上,IAQISO2、IAQINO2、IAQIPM10、IAQIPM25、IAQICO呈现“市区高,郊区低”的分布特征,空气质量指数较高的区域集中在贵阳市主城区中部和东北部  相似文献   

4.
This study examines the relationship between air pollution, social deprivation and health in the city of Leeds, UK under a baseline and three distance-based road user charging (RUC) scenarios set at 2 pence, 10 pence and 20 pence/km. Through application of a series of linked models of traffic, emission and pollutant dispersion, air quality was modelled in response to RUC scenarios. The pollutant modelled were NO(2), PM(10), CO, benzene and 1,3-butadiene, though results of NO(2) are used in this study. The RUC scenarios were compared with the 'base' scenario, all set for the year 2005. The RUC initiatives result in the differences in ambient concentrations of NO(2). The study correlates NO(2) concentrations with derived indices of social deprivation and health. The study concludes that positive but weak relationship exists between air quality and social deprivation, and indicates that deprived population groups are disproportionately exposed to higher NO(2) levels. The relationship between air quality and health status of the population is weak. There is a strong relationship between social deprivation and health status of the population. The study concludes that RUC scenarios result in reducing disparity between affluent and deprived populations.  相似文献   

5.
The indoor and outdoor air quality of two staff quarters of Hong Kong Polytechnic University at Tsim Sha Tsui East (TSTE) and Shatin (ST) were investigated. The air sampling was carried out in winter for about two months starting from January to February of 1996. Fifteen flats from each staff quarter were randomly selected for indoor/outdoor air pollutant measurements. The pollutants measured were NOx, NO, NO2, SO2, CO, and O3. The variations of pollutant concentrations between indoor and outdoor air were investigated on weekday mornings, weekday evenings, weekend mornings, and weekend evenings. All indoor/outdoor pollutant concentrations measured did not exceed the ASHRAE/NAAQS standard. The carbon monoxide concentrations indoors were systemically higher than those outdoors at the TSTE and the ST quarters, both on weekdays and Sunday, which indicates there are CO sources indoors. Except for CO, the indoor levels of other pollutants (NOx, NO, NO2, SO2, and O3) are lower than those outdoors. There was a significant correlation (P < 0.05) between indoor and outdoor concentrations for SO2 and O3 at both the TSTE and the ST quarters. Except for O3, the mean concentrations of all the pollutants in the TSTE quarters, both indoor and outdoor, were higher than that of the ST quarters in all sampling periods. All indoor and outdoor O3 levels were lower at the TSTE quarters than those at the ST quarters. The O3 ratios of TSTE/ST were 0.72 outdoor and 0.79 indoor. This can be explained by the NO titration reaction through NO conversion to NO2.  相似文献   

6.
以京津冀大气污染传输通道“2+26”城市为对象的区域性雾霾专项治理已经开展两年有余。要判断“2+26”城市治霾方案的实施是否取得了显著成效需要通过科学的实证分析加以验证。采集山东省13个内陆城市2016—2018年每日空气质量指数(AQI)、六种单项污染物(PM 2.5、PM 10、SO 2、NO 2、CO、O 3)浓度以及气象条件等数据,以其中属于“2+26”城市的7城市作为实验组,其余6城市作为对照组,基于双重差分法,对“2+26”城市治霾方案在山东省相关城市的实施效果进行评估,试图分离方案实施所带来的环境效应。结果表明:①“2+26”城市治霾方案的实施总体上有效,对污染传输通道7城市空气质量指数(AQI)指标的降低发挥了显著作用。②“2+26”城市治霾方案对污染传输通道城市的PM 2.5、PM 10、CO浓度的降低有显著贡献,但对SO 2、NO 2和O 3指标的改善贡献并不明显。③对方案进行分时段动态效应分析发现,《京津冀及周边地区2017年大气污染防治工作方案》的发布并未对污染传输通道城市空气质量改善产生立竿见影的效果,而《京津冀及周边地区2017—2018年秋冬季大气污染综合治理攻坚行动方案》《京津冀及周边地区2018—2019年秋冬季大气污染综合治理攻坚行动方案》的落实和执行才是“2+26”城市治霾方案显著见效的保障。该研究在严格遵守双重差分法前提条件的同时,还通过了一系列稳健性检验确保评估结果的可靠性。  相似文献   

7.
Indoor air quality in animal buildings is very important to the health of agricultural workers and animals. Carbon dioxide (CO2) and ammonia (NH3) are two of the most important pollutants in pig houses. Four tests were conduced in a mechanically ventilated pig house to study release behaviors of CO2 and NH3 from liquid manure using impulse, pulse and step ventilation inputs. The CO2 and NH3 concentrations were sampled in the exhaust chimney and measured with a CO2 monitor and a NOx analyzer, respectively. The ventilation rate was measured with a ventilation rate sensor in the chimney. A new phenomenon, characterized by a delayed dynamic response of NH3 release to the high ventilation inputs as compared with the response of CO2 release, was encountered. A new CO2 factor was identified as the cause of the delayed NH3 response. An original concept of Carbon-dioxide Accelerated Ammonia Release (CAAR) was developed. It explained that, at the initial stage of gas release induced by the high ventilation, the high release of CO2 gradually raised the pH in the surface manure. The increased pH accelerated the release of NH3. The higher release of NH3 had a negative feedback to the pH. The effects of CO2 and NH3 releases on the pH finally reached a dynamic equilibrium. The NH3 release under the dynamic equilibrium was greatly accelerated compared to that under initial conditions.  相似文献   

8.
A spatial comparison of pollutant concentrations within the residential environment is undertaken, comparing pollutant concentrations from three indoor sampling locations (zones). The indoor air quality base was obtained from sampling the indoor air of 12 residential sites and two office buildings in the metropolitan Boston area. Each residential site was monitored continuously for two weeks, and data were reduced into hourly averages. Interzonal comparisons of the mean of hourly averages, 24-h averages, and daily maximum hourly concentrations were made at all sites. Linear regressions were computed between daily maximum hourly concentrations and mean 24-h concentrations of NO, NO2, and CO for kitchens to determine whether maximum hourly concentrations could be predicted from the 24-h concentration. These pollutants show interzonal statistical differences in residences with gas-fired cooking facilities but not in residences with electric cooking facilities. It was determined that, while one indoor sampling zone is not sufficient to specify indoor pollutant concentration maxima in residences having indoor sources of pollution, the daily mean of hourly pollutant concentrations obtained from one indoor zone can adequately describe the indoor environment. In addition, the maximum indoor hourly concentration for NO, NO2, and CO can be estimated for residences with all electric facilities, by using the mean 24-h concentration. The reliability of similar estimates for NO, NO2, and CO in residences with unvented gas appliances is reduced because of substantially more scatter in the paired data point, particularly at higher pollutant concentrations.  相似文献   

9.
This paper demonstrates association of short-term variation in pollution and health outcomes within the same geographical area for a typical urban setting in the northern part of the UK from time series analysis. It utilises publicly available datasets for regulated air pollutants (PM??, NO?, SO?, CO and O?), meteorology and respiratory hospital admissions (and mortality) between April 2002 and December 2005 to estimate the respiratory health effect of pollution exposure, mainly in the elderly. Our results show that PM?? and O? are positively associated with respiratory hospital admissions in the elderly, specifically in the age group 70-79. CO effects seem to be concentrated on the most elderly age group (80+) whereas NO? seems to have the opposite age-related effect, with lower effects on the more elderly.  相似文献   

10.
This study was performed to investigate the concentration of PM(10) and PM(2.5) inside trains and platforms on subway lines 1, 2, 4 and 5 in Seoul, KOREA. PM(10), PM(2.5), carbon dioxide (CO(2)) and carbon monoxide (CO) were monitored using real-time monitoring instruments in the afternoons (between 13:00 and 16:00). The concentrations of PM(10) and PM(2.5) inside trains were significantly higher than those measured on platforms and in ambient air reported by the Korea Ministry of Environment (Korea MOE). This study found that PM(10) levels inside subway lines 1, 2 and 4 exceeded the Korea indoor air quality (Korea IAQ) standard of 150 microg/m(3). The average percentage that exceeded the PM(10) standard was 83.3% on line 1, 37.9% on line 2 and 63.1% on line 4, respectively. PM(2.5) concentration ranged from 77.7 microg/m(3) to 158.2 microg/m(3), which were found to be much higher than the ambient air PM(2.5) standard promulgated by United States Environmental Protection Agency (US-EPA) (24 h arithmetic mean: 65 microg/m(3)). The reason for interior PM(10) and PM(2.5) being higher than those on platforms is due to subway trains in Korea not having mechanical ventilation systems to supply fresh air inside the train. This assumption was supported by the CO(2) concentration results monitored in tube of subway that ranged from 1153 ppm to 3377 ppm. The percentage of PM(2.5) in PM(10) was 86.2% on platforms, 81.7% inside trains, 80.2% underground and 90.2% at ground track. These results indicated that fine particles (PM(2.5)) accounted for most of PM(10) and polluted subway air. GLM statistical analysis indicated that two factors related to monitoring locations (underground and ground or inside trains and on platforms) significantly influence PM(10) (p<0.001, R(2)=0.230) and PM(2.5) concentrations (p<0.001, R(2)=0.172). Correlation analysis indicated that PM(10), PM(2.5), CO(2) and CO were significantly correlated at p<0.01 although correlation coefficients were different. The highest coefficient was 0.884 for the relationship between PM(10) and PM(2.5).  相似文献   

11.
To predict the radon concentration in a house environment and to understand the role of all factors affecting its behavior, it is necessary to recognize time variation in both air exchange rate and radon entry rate into a house. This paper describes a new approach to the separation of their effects, which effectively allows continuous estimation of both radon entry rate and air exchange rate from simultaneous tracer gas (carbon monoxide) and radon gas measurement data. It is based on a state-space statistical model which permits quick and efficient calculations. Underlying computations are based on (extended) Kalman filtering, whose practical software implementation is easy. Key property is the model's flexibility, so that it can be easily adjusted to handle various artificial regimens of both radon gas and CO gas level manipulation. After introducing the statistical model formally, its performance will be demonstrated on real data from measurements conducted in our experimental, naturally ventilated and unoccupied room. To verify our method, radon entry rate calculated via proposed statistical model was compared with its known reference value. The results from several days of measurement indicated fairly good agreement (up to 5% between reference value radon entry rate and its value calculated continuously via proposed method, in average). Measured radon concentration moved around the level approximately 600 Bq m(-3), whereas the range of air exchange rate was 0.3-0.8 (h(-1)).  相似文献   

12.
Air pollution has been associated with daily mortality in numerous studies over the past decade. However most of these studies were conducted in the United States and Europe with relatively few done in Asia. In the current study, the association between ambient air pollution and daily mortality in Taipei, Taiwan's largest city which has a subtropical climate was undertaken, for the period 1994-1998 using a case-crossover analysis. This design is an alternative to Poisson time series regression for studying the short-term adverse health effects of air pollution. The air pollutants examined included particulate matter (PM(10)), sulfur dioxide (SO(2)), ozone (O(3)), nitrogen dioxide (NO(2)), and carbon monoxide (CO). The largest observed effect, which was without statistical significance, was seen for NO(2) and CO levels on deaths due to respiratory diseases (ORs=1.013 and 1.014, respectively). The well established link between air pollution levels and daily mortality may not be as strong in cities in subtropical areas, although other factors such as differences in pollutant mix or the underlying health of the population may explain the lack of a strong association in this study. Further studies of this type in cities with varying climates and cultures are needed.  相似文献   

13.
Since the last decade the WHO Collaborating Centre for Air Quality Management and Air Pollution Control, Berlin, Germany, operates a quality assurance and control (QA/QC) programme on air quality monitoring in the WHO European Region. As main activity Intercomparison workshops have been established for air monitoring network laboratories on a regular basis to harmonise air quality measurements, analysis and calibration techniques. 36 air hygiene laboratories of public health and environmental institutions of 24 countries participated in twelve Intercomparisons between 1994 and 2004. The majority was carried out for NO, NO(2), SO(2) and O(3). The results were predominantly satisfactory for automatic methods. The results of manual methods were mainly in a good, and for several concentration levels partly very good accordance with the data obtained by the monitors.  相似文献   

14.
Recent studies have pointed to evidence that fine particles in the air could be significant contributors to respiratory and cardiovascular diseases and mortality. Epidemiologists looking at the health effects of particulate pollution need more information from various receptor locations to improve the understanding of this problem. Detailed information on temporal, spatial and size distributions of particulate pollution in urban areas is also important for air quality modellers as well as being an aid to decision and policy makers of local authorities. This paper presents a detailed analysis of temporal and seasonal variation of PM(10) and PM(2.5) levels at one urban roadside, one urban background and one rural monitoring location. Levels of PM(10), PM(2.5) and coarse fraction of particulates are compared. In addition, particulate levels are compared with NO(2) and CO concentrations. The study concludes that PM(10) and PM(2.5) are closely related at urban locations. Diurnal variation in PM(2.5)/PM(10) ratio shows the influence of vehicular emission and movement on size distribution. This ratio is higher in winter than in summer, indicating a build-up or longer residence time of finer particulates or washout due to wet weather in winter. In the second part of this study, a disease burden analysis is carried out based on the dose-response relationships recommended by the UK Committee on the Medical Effects of Air Pollution. The disease burden analysis indicates that if Marylebone Road (MR) levels of PM(10) were prevalent all over London, it will result in around 2.5% increase in death rates due to all causes. Whereas, if Bloomsbury (BB) levels were prevalent in London, which is more likely to occur as this is more representative of the urban background environment to which people in London are likely to be exposed, the corresponding increase would be around 1.7%. Considering this, in London, at Bloomsbury levels, 973 deaths and 1515 respiratory hospital admissions (RHA) are attributable to PM(10) while 2140 RHA are attributable to NO(2). After deducting the disease burden due to background levels at Rochester (RC), PM(10) emission caused by anthropogenic activities in London equates to 273 additional deaths and 410 additional RHA, while NO(2) account for additional 1205 incidences of RHA.  相似文献   

15.
In its evaluation of federal ambient air quality criteria for carbon monoxide (CO), the U.S. Environmental Protection Agency is seeking to identify the mechanisms of CO exposure and the populations at risk. The suitability of existing fixed-site monitoring networks to characterize population exposure is also being studied. This paper describes field measurements in two major metropolitan areas of CO exposure in the passenger sections of 1164 buses, taxis, and police cars. The objectives of the program were to identify high-CO vehicles and to elucidate the mechanisms for high passenger exposures. Vehicle fleets were initially screened with passive dosimeters and pump-driven personal samplers. Selected vehicles were then instrumented with portable electrochemical-cell continuous analyzers coupled to recorders. Principal CO sources and intrusion pathways were pinpointed by use of an inert tracer gas (SF6) detection system. Intrusion tests were made at idle and with the vehicles in motion. Fixed-station monitoring values were found to underpredict, in a nonuniform manner, out-of-vehicle CO exposures determined by the field measurements. In 58% of the 120 personal sampler readings for rides greater than eight hours, the EPA eight-hour ambient air quality standard for carbon monoxide (9 ppm) was exceeded.  相似文献   

16.
Given that Hong Kong is one of the most densely populated cities in the world, the exposure of the Hong Kong people is one of the interesting research areas. In this study, an indirect approach was used to estimate the exposure to nitrogen dioxide (NO2), respiratory dust (PM10) and carbon monoxide (CO) pollutants experienced by different age groups of people in Hong Kong. The average concentrations of the 20 major microenvironments obtained from our measurement survey data, together with the people activity pattern data obtained from 7-day recall questionnaires, were used to predict frequency distributions to exposure assessment. Our results showed that Hong Kong people spent more than 86% of their time indoors. Homes were shown to be the one of the major exposure sites to NO2, CO and PM10 for all age groups. Our results also indicate that the 24-h NO2 exposure for individuals, irrespective of age, spending more than 2 h in commuting daily, was observed to be exceeding the 24-h NO2 exposure standards. This study was one of the pioneering studies with valuable contribution for modeling the estimates of exposures to NO2, PM10 and CO of different age groups in Hong Kong.  相似文献   

17.
以武汉市2000~2013年数据为基础,构建了城市化综合水平和空气环境综合指数的评价指标体系,利用结构熵权法和响应度模型对城市化进程中的空气环境响应时序特征和整体响应强度进行了比较分析。结果表明:(1)2000年后武汉市城市化呈现快速增长态势,进入了一个快速增长时期;空气环境综合指数及其分量呈现不同的变化特征,综合指数呈波动中递增趋势;(2)空气环境综合指数及其分量对城市化有着不同的响应特征,其中,空气质量指数与综合指数由正响应转向负响应,2010年为拐点,表明近年来,武汉市空气环境压力变大,空气质量有恶化的趋势;(3)相同城市化进程中,空气环境质量的正向响应相对于空气负荷压力的减小具有不一致性和滞后性,2013年后的武汉市空气质量需要持久努力改善。城市空气环境质量改善是一个漫长的过程,需要在减小空气污染排放的压力同时,调整产业结构、节能减排,并要积极预防城市化扩张过程中的建设施工、道路、裸露地面等扬尘污染。  相似文献   

18.
为探索新的空气质量预报方法,提高预报准确率,采用统计和对比方法,分析了长沙市空气质量现状,介绍了天气形势相似及动态逐步回归两种空气质量统计预报方法,并对其一年多的运行结果进行了检验和对比。结果表明,长沙市空气污染主要由PM\-\{10\}和SO\-2浓度超标引起, 且具有明显的空间分布特征;5年来长沙城市空气质量明显好转;两种预报方法对各污染物都有一定的预报能力,预报的误差绝对值多集中在30以内,而级别误差基本上在1级以内。两种方法对NO\-2的预报准确率均在98%左右,预报效果优良。绝对误差对比发现,两种预报方法对SO\-2的预报明显优于PM\-\{10\}预报;级别准确率对比时,两种预报方法对3种污染物的预报准确率相近。两种预报方法对3个污染因子的预报准确率呈现出NO\-2优于SO\-2优于PM\-\{10\}的趋势。  相似文献   

19.
The amount of NO2 and NO produced by the machine smoking of cigarettes was determined for 15 commercial Canadian brands. Average yield of NO was 1.44 μmoles or about 13% of the average reported for American cigarettes. Levels of NO2 were less than 12% of NO and were probably due to the oxidation of NO. In order to assess the contribution of tobacco smoke to levels of NO in ambient air, 5 brands of cigarettes were smoked in 27 cubic meter controlled environment room. Ventilation conditions were either 2.5 or 5.0 air changes per hour (ACH) and each experiment was replicated 3 times for a total of 30 experiments. Ventilation rates of 0.3 and 1.5 ACH were also selected in a second series of experiments in which only one brand of cigarette was smoked. Least squares estimates for the effective ventilation rates were obtained in the usual manner after linearizing the decay portion of the NO time curve. In each of the experiments, the regression explained at least 95% of the variation in the levels of NO with time. Loss of NO due to factors other than ventilation appeared to be constant within experimental error and averaged 2.22 ACH. Equilibrium values for NO were grossly underestimated when results from currently accepted proecedures for smoke analysis were used in modeling the growth and decay of NO. Goodness-of-fit was improved when equilibrium values were estimated based on observed levels in ambient air. This approach may be more suitable for evaluating the potential contribution of cigarette smoke to levels of indoor air pollutants.  相似文献   

20.
Most houses in the Netherlands are equipped with gas-fired heaters and cooking appliances,since large amounts of natural gas are available within the country since the mid-1960's. Carbon monoxide poisoning due to coal fires has virtually ceased to exist when coal-fired heaters were replaced by gas heaters. However, such poisonings still occur, although to a lesser extent, due to the use of instantaneous water heaters (geisers) that are gas fired. An investigation was carried out to establish the CO production potential of geisers under normal conditions of use. The study involved 254 houses; the results indicated that 17% of the geisers produced a CO level of more than 50 μL/L in the kitchens where they were located, after 15 min of operation. Presence of a flue, burner type, and maintenance system proved to be the main controlling factors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号