首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   78篇
  免费   2篇
  国内免费   1篇
安全科学   5篇
废物处理   4篇
环保管理   14篇
综合类   18篇
基础理论   3篇
污染及防治   32篇
评价与监测   4篇
灾害及防治   1篇
  2022年   1篇
  2021年   1篇
  2020年   2篇
  2019年   4篇
  2018年   2篇
  2016年   2篇
  2015年   1篇
  2014年   4篇
  2013年   5篇
  2012年   4篇
  2011年   7篇
  2010年   4篇
  2009年   6篇
  2008年   4篇
  2007年   9篇
  2006年   5篇
  2005年   5篇
  2004年   5篇
  2003年   4篇
  2002年   5篇
  2001年   1篇
排序方式: 共有81条查询结果,搜索用时 19 毫秒
31.
32.
In this research, a risk assessment was undertaken in order to develop the remediation and management strategy of a contaminated gunnery site, where a nearby flood controlling reservoir is under construction. Six chemicals, including explosives and heavy metals, posing potential risk to environmental and human health, were targeted in this study. A site-specific conceptual site model was constructed, based on effective, reasonable exposure pathways, to avoid any overestimation of the risk. Also, conservative default values were adapted to prevent underestimation of the risk when site-specific values were not available. The risks posed by the six contaminants were calculated using the API’s Decision Support System for Exposure and Risk Assessment, with several assumptions. In the crater-formed-area (Ac), the non-carcinogenic risks (i.e., HI values) of tri-nitro-toluene (TNT) and Cd were slightly larger than 1, but for RDX (Royal Demolition Explosives) was over 50. The total non-carcinogenic risk of the whole gunnery range was calculated to be 62.5, which was a significantly high value. The carcinogenicity of Cd was estimated to be about 10−3, while that for Pb was about 5 × 10−4, which greatly exceeded the generally acceptable carcinogenic risk level of 10−4–10−6. It was concluded from the risk assessment that there is an immediate need for remediation of both carcinogens and non-carcinogens before construction of the reservoir. However, for a more accurate risk assessment, further specific estimations of the changes in environmental conditions due to the construction of the reservoir will be required; and more over, the effects of the pollutants to the ecosystem will also need to be evaluated.  相似文献   
33.
The present study investigated the occurrence of 29 selected micropollutants such as endocrine disrupting compounds (EDCs) and pharmaceuticals and personal care products (PPCPs) in surface waters and wastewaters in Seoul (South Korea) during both dry and wet weather conditions. The study area was selected based on the lack of available information regarding the suspected contamination of rivers/creeks by EDCs and PPCPs in the Seoul region and the presence of a wastewater treatment plant (WWTP), which serves approximately 4.1 million inhabitants and has a design capacity of 1,297?×?103 m3/day. Many target compounds (83 %) were detected in samples collected from wastewater treatment influent/effluent, creek water, and combined sewer overflow (CSO). The total EDC/PPCP concentrations were as follows: WWTP influent (69,903 ng/L)?>?WWTP effluent (50,175 ng/L) >3 creek samples (16,035–44,446 ng/L) during dry weather, and WWTP influent (53,795 ng/L)?>?WWTP bypass (38,653 ng/L) >5 creek samples (15,260–29,113 ng/L) >2 CSO samples (11,109–11,498 ng/L) during wet weather. EDCs and PPCPs were found to be present at high daily loads (65.1 and 69.8 kg/day during dry and wet weather, respectively) in the WWTP effluent. Compound removal by the WWTP varied significantly by compound: caffeine, diclofenac, ibuprofen, naproxen, and propylparaben (>90 %), and acesulfame, DEET, iohexol, iopromide, and iopamidol (<5 %). These findings and literature information support the hypothesis that the efficiency of removal of EDCs and PPCPs is strongly dependent on both removal mechanism (e.g., biodegradation, adsorption to sludge, and oxidation by chlorine) and compound physicochemical properties (e.g., pK a and hydrophobicity).  相似文献   
34.
A novel on-board hydrogen generation concept using Al coil with NaOH was investigated. The reaction rate was successfully controlled by introducing a pumping system for the NaOH solution. The time for the flow to develop fully was mainly dependent on the solution temperature, and the fastest start time recorded was 60 sec at a solution temperature of 70°C. The maximum H2 generation rate was 200 L min–1 with a prototype design of the on-board hydrogen generation system 1/8 times the size of a full-size reactor. The H2 generation process coupled with the solution pumping system was simulated with three-dimensional fluid dynamic software, and the calculated H2 flow and temperature rise of the system were validated with experimental data.  相似文献   
35.
A monitoring method of biofouling in reverse osmosis (RO) system was proposed based on the fluorescent signal of resorufin, which is reduced by nicotinamide adenine dinucleotide released from viable cells during aerobic respiration. The fluorescent signal of resorufin reduced by planktonic cells and microorganisms of biofilm showed linearity, indicating its feasibility to monitor biofouling in a RO system. For the application of the method to the lab-scale RO system, the injection concentration of resazurin and the injection flow rate were optimized. Biofilm on RO membranes continuously operated in a lab-scale RO system was estimated by resorufin fluorescence under optimized detection condition. As a result, resorufin fluorescence on RO membrane showed a significant increase in which the permeability of RO system decreased by 30.48%. Moreover, it represented the development of biofilm as much as conventional biofilm parameters such as adenosine triphosphate, extracellular polymeric substances, and biofilm thickness. The proposed method could be used as a sensitive and low-cost technology to monitor biofouling without autopsy of membranes.  相似文献   
36.
Seo Y  Jo SH  Ryu CK  Yi CK 《Chemosphere》2007,69(5):712-718
CO(2) capture from flue gas using a sodium-based solid sorbent was investigated in a bubbling fluidized-bed reactor. Carbonation and regeneration temperature on CO(2) removal was determined. The extent of the chemical reactivity after carbonation or regeneration was characterized via (13)C NMR. In addition, the physical properties of the sorbent such as pore size, pore volume, and surface area after carbonation or regeneration were measured by gas adsorption method (BET). With water vapor pretreatment, near complete CO(2) removal was initially achieved and maintained for about 1-2min at 50 degrees C with 2s gas residence time, while without proper water vapor pretreatment CO(2) removal abruptly decreased from the beginning. Carbonation was effective at the lower temperature over the 50-70 degrees C temperature range, while regeneration more effective at the higher temperature over the 135-300 degrees C temperature range. To maintain the initial 90% CO(2) removal, it would be necessary to keep the regeneration temperature higher than about 135 degrees C. The results obtained in this study can be used as basic data for designing and operating a large scale CO(2) capture process with two fluidized-bed reactors.  相似文献   
37.
We report one case of a familial complex chromosomal rearrangement (CCR) involving four different chromosomes 5, 10, 16 and 18. The CCR was detected prenatally at 20 weeks' gestation because of advanced maternal age and history of recurrent miscarriages. Cytogenetic analysis of cultured amniotic fluid cells with GTG banding showed a 46,XX,t(5;16;10;18)(q13;q22;q11.2;q21) karyotype. Parental cytogenetic study revealed that the mother has the same CCR. RBG banding, high-resolution banding and fluorescence in situ hybridization (FISH) were used to characterize further and confirm the conventional banding data. No physical abnormalities were shown in the targeted fetal ultrasonography examination. The parents decided to continue the pregnancy. The child is now 2 years old and has neither congenital anomalies nor evidence of delayed psychomotor development. The fetal targeted ultrasound and FISH analysis helped us reassure fetal status. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   
38.
39.
40.
This paper evaluates the mitigation effect of Tokai earthquake measures on housing damage using a counterfactual approach. It focuses on those measures that stimulate ex‐ante investment in disaster prevention in the supposedly affected area, including earthquake‐proof retrofitting and improved housing construction; the effect of the measures on housing losses is estimated monetarily. The study compares factual disaster damage computed using a real distribution of houses with counterfactual damage to a hypothetical housing distribution that would occur if the measures were not implemented. The key findings are: (i) the disaster mitigation effects of Tokai earthquake measures on housing amount to approximately JPY 18 billion (USD 0.18 billion) for Yamanashi Prefecture and JPY 0.26 trillion (USD 2.6 billion) for Shizuoka Prefecture, which would be at the centre of the event; (ii) a before–after comparison biases estimates of the mitigation effect; and (iii) statistically, the measures do not mitigate the housing damage predicted for an earthquake in Tokai.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号