首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   33篇
  免费   0篇
废物处理   4篇
环保管理   1篇
综合类   4篇
基础理论   2篇
污染及防治   9篇
评价与监测   8篇
社会与环境   5篇
  2023年   3篇
  2022年   2篇
  2021年   2篇
  2018年   1篇
  2016年   1篇
  2015年   1篇
  2014年   1篇
  2013年   4篇
  2012年   1篇
  2011年   4篇
  2010年   1篇
  2009年   1篇
  2008年   2篇
  2006年   1篇
  2005年   3篇
  2002年   2篇
  1996年   1篇
  1993年   1篇
  1955年   1篇
排序方式: 共有33条查询结果,搜索用时 15 毫秒
31.
A simple and robust analytical method was developed to simultaneously detect and quantify 17β-estradiol (E2), estrone (E1), 17β-estradiol-3-sulphate (E2-3S), and estrone-3-sulphate (E1-3S) in aqueous solutions (calcium chloride and artificial urine solutions) and agricultural soils using high performance liquid chromatography and UV detection. The standards for all four compounds were linear in the range of 0.01 to 1.0 μg mL(-1) (n = 6) and 1.0 to 20 μg mL(-1) (n = 6), respectively, with correlation coefficients > 0.999. The on-column limits of detection at an injection volume of 50 μL and S/N (signal: noise) ratio of 3 were: 9.0 ng mL(-1), 10 ng mL(-1), 5.0 ng mL(-1), and 7.0 ng mL(-1) for E2-3S, E1-3S, E2 and E1, respectively. The limit of detection and quantification in artificial urine solution and CaCl(2) solution was 1.0 ng mL(-1) for all four compounds. Method detection limits for the compounds in the 3 soils ranged from 2 to 2.4 ng g(-1) (E2-3S and E1-3S), and 1.0 to 2.9 ng g(-1) (E2 and E1), respectively.  相似文献   
32.
A simple and robust analytical method was developed to simultaneously detect and quantify 17β-estradiol (E2), estrone (E1), 17β-estradiol-3-sulphate (E2-3S), and estrone-3-sulphate (E1-3S) in aqueous solutions (calcium chloride and artificial urine solutions) and agricultural soils using high performance liquid chromatography and UV detection. The standards for all four compounds were linear in the range of 0.01 to 1.0 μg mL?1 (n = 6) and 1.0 to 20 μg mL?1 (n = 6), respectively, with correlation coefficients > 0.999. The on-column limits of detection at an injection volume of 50 μL and S/N (signal: noise) ratio of 3 were: 9.0 ng mL?1, 10 ng mL?1, 5.0 ng mL?1, and 7.0 ng mL?1 for E2-3S, E1-3S, E2 and E1, respectively. The limit of detection and quantification in artificial urine solution and CaCl2 solution was 1.0 ng mL?1 for all four compounds. Method detection limits for the compounds in the 3 soils ranged from 2 to 2.4 ng g?1 (E2-3S and E1-3S), and 1.0 to 2.9 ng g?1 (E2 and E1), respectively.  相似文献   
33.
Journal of Material Cycles and Waste Management - For environmental protection, safe disposal of toxic pollutants such as heavy metal is very important since they are regarded as hazardous waste....  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号