首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   33篇
  免费   0篇
  国内免费   2篇
安全科学   1篇
废物处理   3篇
环保管理   4篇
综合类   10篇
基础理论   4篇
污染及防治   8篇
评价与监测   4篇
社会与环境   1篇
  2023年   1篇
  2022年   1篇
  2021年   4篇
  2018年   3篇
  2017年   3篇
  2016年   1篇
  2015年   2篇
  2014年   1篇
  2012年   2篇
  2011年   2篇
  2010年   1篇
  2009年   1篇
  2008年   2篇
  2006年   2篇
  2005年   1篇
  2004年   1篇
  2003年   3篇
  2002年   4篇
排序方式: 共有35条查询结果,搜索用时 15 毫秒
11.
A passive sampler has been developed and is demonstrated in situ for urban runoff. The passive sampler is compared to conventional composite (time-dependent and flow-weighted) bottle sampling during and between storm events. The sampling was carried out at established stormwater stations; before and after a stormwater detention pond. In situ deployment of the passive sampler provides the metal concentrations, corresponding to the electrochemically available fraction of total metal, for time-dependent samples collected in parallel. The sampler provides improved accuracy compared to bottle sampling because contamination during sample transport and handling is minimised. Laboratory handling is reduced by direct analysis of the accumulated metals on the receiving membrane by laser ablation inductively coupled plasma mass spectrometry. Passive sampling also solves the problem of metal speciation change during transport to the laboratory, which is a potential problem for bottle samples. The low cost and convenience of the passive sampler and subsequent analysis should allow significantly more extensive spatial and temporal monitoring of metals in the aquatic environment than has previously been possible.  相似文献   
12.
ABSTRACT: A modeling framework was developed for managing copper runoff in urban watersheds that incorporates water quality characterization, watershed land use areas, hydrologic data, a statistical simulator, a biotic ligand binding model to characterize acute toxicity, and a statistical method for setting a watershed specific copper loading. The modeling framework is driven by export coefficients derived from water quality parameters and hydrologic inputs measured in an urban watershed's storm water system. This framework was applied to a watershed containing a copper roof built in 1992. A series of simulations was run to predict the change in receiving stream water chemistry caused by roof aging and to determine the maximum copper loading (at the 99 percent confidence level) a watershed could accept without causing acute toxicity in the receiving stream. Forecasting the amount of copper flux responsible for exceeding the assimilation capacity of a watershed can be directly related to maximum copper loadings responsible for causing toxicity in the receiving streams. The framework developed in this study can be used to evaluate copper utilization in urban watersheds.  相似文献   
13.
14.
Dioxin analysis in food and feed can be characterized as an analytical application where very high accuracy is required at very low levels of contamination. Gas chromatography (GC) in combination with 13C-label isotope dilution (ID) high resolution mass spectrometry (HRMS) is the reference congener-specific technique characterized by pronounced selectivity, precision and trueness at parts-per-trillion (ppt) and sub-parts-per-trillion (sub-ppt) levels. The quality of the analytical data produced routinely by a laboratory should be adequate for its intended purpose, i.e., one will seek a compromise between the cost and time needed and the consequences of incorrect decisions due to erroneous results. The requirements for reproducibility are usually dependent on the analyte concentrations and have been expressed in various empirical functions. While Horwitz or modified functions are widely useful for many purposes, it would be difficult to expect these functions to cover every analytical problem. This study reports on precision characteristics achieved by the GC-ID-HRMS reference method for polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (DL-PCBs) in food and feed in two interlaboratory method-performance studies among expert laboratories with long-standing experience in this field. Striking linear functions in log scale between reproducibility standard deviation and congener's level over a concentration range of 10(-8)-10(-14)g per g fresh weight are observed. The data fit very well to a Horwitz-type function of the form sR=0.153c0.904, where sR and c are dimensionless mass ratios expressed in pg g(-1) on fresh weight, regardless of the nature of the toxic congeners, food and feed matrices, or sample preparation methods. We demonstrate that the proposed function is suitable for use as a fitness-for-purpose criterion for proficiency assessment in interlaboratory comparisons on dioxins and related compounds in food.  相似文献   
15.
16.
产业联盟透视 关于中外产业联盟问题的10个答问   总被引:1,自引:0,他引:1  
国内外产业联盟的形成和发展,原因在于经济全球化、高新技术特别是信息技术的快速发展。联盟按照自愿、平等、互利原则建立,这种组织形式有利于成员间的资源整合,有利于新技术的研发、统一标准、开拓全球市场,使联盟成员在市场竞争中获得更多的优势。联盟的发展需要有明确的定位,坚持战略性、市场化、互利性原则。目前安防行业成立的产业联盟,本质上是企业联盟。在企业家探索、实践产业联盟之际,我们对产业联盟的来龙去脉、对联盟的定位和功能进行了梳理,目的是抛砖引玉,希望大家对产业联盟、企业联盟有一个相对全面、直观的解读。  相似文献   
17.
Deinking paper sludge (DPS)/high density polyethylene (HDPE) composites with and without coupling agent (3 % of maleated polyethylene (MAPE)) were manufactured by twin-screw extrusion followed by injection molding with high percentages of DPS (0, 20, 30 and 40 %). The effects of DPS content and MAPE on the mechanical, thermal, and morphological properties of the DPS/HDPE composites were investigated. Increasing DPS content in composites increased the tensile and flexural modulus (E; MOE), tensile and flexural strength (Rm; MOR), while decreased elongation at break and Un-notched impact resistance due to a poor adhesion between the DPS and HDPE. The addition of DPS also improved the thermal stability and increased the composites crystallinity. High content of DPS (40 %) and 3 % MAPE achieved good interfacial adhesion between fibres of DPS and HDPE. Therefore, an increase is observed for Rm, MOR, ductility, and impact toughness.  相似文献   
18.
Alkylphenols and alkylphenol ethoxylates are ubiquitous wastewater contaminants. In this study the oxidation of nonylphenol ethoxylates (NPEO) and octylphenol ethoxylates (OPEO) by oxidant systems generating hydroxide radicals was evaluated. The reaction of each oxidant with a technical mixture of NPEO (Tergitol™) and OPEO (Triton X-100™) in ultrapure laboratory water and four aqueous environmental matrices was carried out in order to develop an understanding of reaction kinetics. The oxidation of APEOs was evaluated by hydroxyl radical generated by (1) hydrogen peroxide in the presence of ultraviolet light, (2) Fenton’s reagent, and (3) a photo-Fenton’s process. The second order kinetic rate constant for both NPEO and OPEO with hydroxyl radical was calculated to be 1.1 × 1010 M−1 s−1. The efficacy of the AOPs within an aqueous environmental matrix was dependent on the rate of formation of hydroxyl radical and the scavenging capacity of the matrix. A model based on the hydroxyl radical formation, scavenging capacity and the kinetic rate constant of target APEO was developed from the existing literature and applied to predict the concentration of APEOs in solution during advanced oxidation in different aqueous environmental matrices.  相似文献   
19.
Nervous system active pharmaceutical ingredients (APIs), including anti-depressants and opioids, are important clinically administered pharmaceuticals within healthcare facilities. This study provides source characterization data describing the composition and magnitude of nervous system APIs present in healthcare facility wastewaters. Concentrations and mass loadings of ten nervous system APIs and three nervous system API metabolites are reported for wastewaters from a hospital, nursing, assisted living, and independent living facility within a single municipality. Concentrations of nervous system APIs ranged from non-detectable levels for alprazolam in all four facility wastewaters to a high of 290 ng/L amitriptyline in nursing facility wastewater. The summed mean concentration of all thirteen analytes ranged from 402 ng/L in independent living facility wastewater to 624 ng/L in assisted living facility wastewater. Wastewater flow rates from each facility were combined with concentration data to estimate the daily mass loading of nervous system APIs leaving each facility through wastewater discharge to the municipal sewer system. The total mass loading of all thirteen analytes for the hospital, nursing, assisted living, and independent living facility was 228, 44, 29.5, and 28.1 mg/day, respectively. The total mass loading of nervous system APIs contributed to the municipality's wastewater from all four facilities was 330 mg/day.  相似文献   
20.
ABSTRACT: Abundant use of copper based products has resulted in increased violation of copper water quality criteria in runoff from urban storm water systems. The objectives of this work were to understand the mobility and toxicity of copper in an urban watershed and to apportion the amount of copper entering the freshwater receiving stream from different urban land covers using a mass balance approach. Sixteen rainfall events collected from the University of Connecticut study watershed between August 1998 and September 2000 were analyzed to assess copper flux in an urban storm water system. Mean flow weighted dissolved copper concentrations observed in the study for copper based architectural material runoff, pervious area runoff, impervious area runoff, and in the receiving stream were 1210 ± 840, 9 ± 3, 8 ± 2, and 14 ± 7 μg/L, respectively. Mean dissolved copper concentrations in the receiving stream exceeded Connecticut's water quality criteria. Despite exceeding the dissolved concentration based criteria, cupric ion concentrations at the system outlet remained below 0.05 μg/L for all storms analyzed, and no acute toxicity (using Daphnia pulex as the test organism) was measured in samples collected from the stream.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号