首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   118篇
  免费   1篇
  国内免费   8篇
安全科学   10篇
废物处理   10篇
环保管理   11篇
综合类   19篇
基础理论   25篇
污染及防治   39篇
评价与监测   11篇
社会与环境   2篇
  2022年   3篇
  2021年   5篇
  2019年   4篇
  2018年   10篇
  2017年   7篇
  2016年   6篇
  2014年   4篇
  2013年   19篇
  2012年   6篇
  2011年   10篇
  2010年   6篇
  2009年   11篇
  2008年   11篇
  2007年   6篇
  2006年   3篇
  2005年   4篇
  2004年   4篇
  2003年   1篇
  2002年   2篇
  2001年   4篇
  2000年   1篇
排序方式: 共有127条查询结果,搜索用时 953 毫秒
101.
Kwon SB  Park J  Jang J  Cho Y  Park DS  Kim C  Bae GN  Jang A 《Chemosphere》2012,87(11):1260-1264
Increasing concerns about the spread of airborne pathogens such as severe acute respiratory syndrome (SARS) and novel swine-origin influenza A (H1N1) have attracted public attention to bioaerosols and protection against them. The airborne pathogens are likely to be expelled from coughing or speaking, so the physical data of the exhaled particles plays a key role in analyzing the pathway of airborne viruses. The objective of this study was to analyze the initial velocity and the angle of the exhaled airflow from coughing and speaking of 17 males and 9 females using Particle Image Velocimetry (PIV) and acrylic indoor chamber. The results showed that the average initial coughing velocity was 15.3 m/s for the males and 10.6 m/s for the females, while the average initial speaking velocity was 4.07 m/s and 2.31 m/s respectively. The angle of the exhaled air from coughing was around 38° for the males and 32° for the females, while that of the exhaled air from speaking was around 49° and 78° respectively. Also, the linear relation between the tested subject’s height and their coughing and speaking velocity was shown in this study.  相似文献   
102.
A plastic fraction consisting mainly of polyurethane/styrofoam waste is generated after separating valuable spare parts and metals from used electrical home appliances. In Korea, such waste is currently incinerated in cement kilns or is landfilled. However, owing to its high volatile matter content, conversion into gaseous or liquid pyrolysis products is a preferable alternative. A pyrolysis process of polyurethane and styrofoam waste from electrical home appliances was evaluated by characterizing the products generated at 500°–800°C. The para meters determined were the yields of gas, oil, and char; the characteristics of the remaining char; and the con centration of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzo-furans in the product gas. As expected, the char yield decreased at higher temperatures, whereas gas and oil yields showed increasing tendency. The oil products could be used as storable fuels with a calorific value of 6000–8000 kcal/kg. Fine pores were observed in the char. The adsorption and decolorizing ability of the char were almost the same as those of activated carbon, so that pyrolysis char has potential for use as a sorbent. Further feasibility studies will be needed before utilizing pyrolysis technology to recover either fuels or usable products from polyurethane/styrofoam waste.  相似文献   
103.
104.
TiO2-supported manganese oxide catalysts formed using different calcination temperatures were prepared by using the wet-impregnation method and were investigated for their activity in the low-temperature selective catalytic reduction (SCR) of NO by NH3 with respect to the Mn valence and lattice oxygen behavior. The surface and bulk properties of these catalysts were examined using Brunauer-Emmett-Teller (BET) surface area, X-ray diffraction (XRD), temperature-programmed reduction (TPR), and temperature-programmed desorption (TPD). Catalysts prepared using lower calcination temperatures, which contained Mn4+, displayed high SCR activity at low temperatures and possessed several acid sites and active oxygen. The TPD analysis determined that the Brönsted and Lewis acid sites in the Mn/TiO2 catalysts were important for the low-temperature SCR at 80~160 and 200~350 °C, respectively. In addition, the available lattice oxygen was important for attaining high NO to NO2 oxidation at low temperatures.

Implications: Recently, various Mn catalysts have been evaluated as SCR catalysts. However, there have been no studies on the relationship of adsorption and desorption properties and behavior of lattice oxygen according to the valence state for manganese oxides (MnOx). Therefore, in this study, the catalysts were prepared by the wet-impregnation method at different calcination temperatures in order to show the difference of manganese oxidation state. These catalysts were then characterized using various physicochemical techniques, including BET, XRD, TPR, and TPD, to understand the structure, oxidation state, redox properties, and adsorption and desorption properties of the Mn/TiO2 catalysts.  相似文献   
105.
Modeling uptake kinetics of cadmium by field-grown lettuce   总被引:1,自引:0,他引:1  
Cadmium uptake by field grown Romaine lettuce treated with P-fertilizers of different Cd levels was investigated over an entire growing season. Results indicated that the rate of Cd uptake at a given time of the season can be satisfactorily described by the Michaelis-Menten kinetics, that is, plant uptake increases as the Cd concentration in soil solution increases, and it gradually approaches a saturation level. However, the rate constant of the Michaelis-Menten kinetics changes over the growing season. Under a given soil Cd level, the cadmium content in plant tissue decreases exponentially with time. To account for the dynamic nature of Cd uptake, a kinetic model integrating the time factor was developed to simulate Cd plant uptake over the growing season: C Plant=C Solution.PUF max.exp[-b.t], where C Plant and C Solution refer to the Cd content in plant tissue and soil solution, respectively, PUF max and b are kinetic constants.  相似文献   
106.
107.
Cho YC  Kwon OS  Sokol RC  Bethoney CM  Rhee GY 《Chemosphere》2001,43(8):1119-1126
Evidence of reductive dechlorination of polychlorinated biphenyls (PCBs) in sediments was investigated in Hudson River sediments dredged and encapsulated in 1978 at Moreau, NY. The effect of different moisture contents in dredged sediments on dechlorination and dechlorinating microorganisms was also determined using PCB-spiked sediments in which the moisture level was adjusted by simulating a dewatering process. The congener pattern of PCBs indicated that the dechlorination in the dredged sediments was far less advanced than that in the river sediments collected from the general area of the dredged site (Ft. Edward site). Dechlorination in encapsulated sediments at the Moreau site appeared to have stopped soon after dredging. When microorganisms eluted from the encapsulated sediments were inoculated in clean sediments spiked with Aroclor 1242, an extensive dechlorination was observed, indicating that the encapsulated sediments still harbored dechlorinating microorganisms. However, the same inoculum failed to further dechlorinate residual congeners in the dredged sediments. On the other hand, an inoculum obtained in 1990 from the dredged site in the Hudson River dechlorinated the residual congeners further. In simulated dredged sediments, the maximum level of dechlorination was lower at reduced moisture contents. The population size of dechlorinating microorganisms, as determined by the most probable number (MPN) technique, was also smaller at the lower moisture levels. There was a significant correlation between the maximum extent of dechlorination and the specific death rate of dechlorinating populations. These results indicate that the underlying mechanism of the moisture-dependent maximum dechlorination is the moisture-dependence of the death rate of dechlorinating microorganisms.  相似文献   
108.
Kwon JS  Yun ST  Kim SO  Mayer B  Hutcheon I 《Chemosphere》2005,60(10):1416-1426
We conducted kinetic and equilibrium sorption experiments on removal of Zn(II) from aqueous solutions by scoria (a vesicular pyroclastic rock with basaltic composition) from Jeju Island, Korea, in order to examine its potential use as an efficient sorbent. The batch-type kinetic sorption tests under variable conditions indicated that the percentage of Zn(II) removal by scoria increases with decreasing initial Zn(II) concentration, particle size, and sorbate/sorbent ratio. However, the sorption capacity decreases with the decrease of the initial Zn(II) concentration and sorbate/sorbent ratio. Equilibrium sorption tests show that Jeju scoria has a larger capacity and affinity for Zn(II) sorption than commercial powdered activated carbon (PAC); at initial Zn(II) concentrations of more than 10mM, the sorption capacity of Jeju scoria is about 1.5 times higher than that of PAC. The acquired sorption data are better fitted to the Langmuir isotherm than the Freundlich isotherm. Careful examination of ionic concentrations in sorption batches suggests that the sorption behavior is mainly controlled by cation exchange and typically displays characteristics of 'cation sorption'. The Zn(II) removal capacity decreases when solution pH decreases because of the competition with hydrogen ions for sorption sites, while the Zn(II) removal capacity increases under higher pH conditions, likely due to hydroxide precipitation. At an initial Zn(II) concentration of 5.0mM, the removal increases from 70% to 96% with the increase of initial pH from 3.0 to 7.0. We recommend Jeju scoria as an economic and efficient sorbent for Zn(II) in contaminated water.  相似文献   
109.
Lee JK  Führ F  Kwon JW  Ahn KC 《Chemosphere》2002,49(2):173-181
In order to elucidate the long-term fate of the sulfonylurea herbicide cinosulfuron, the 14C-labelled chemical was applied to a clay loam soil, encased in two lysimeters, 22 days after rice (Oryza sativa L.) transplanting, and rice plants were grown for four consecutive years. Throughout the experimental period, leaching through soil profiles, absorption and translocation by rice plants, and distribution of 14C by downward movement in the soil layers were clarified. The total volume of leachates collected through the lysimeter soil over the four years amounted to 168 and 146 L in lysimeters I and II, respectively. The leachates contained 2.43% and 2.99% of the originally applied 14C-radioactivity, corresponding to an average concentration of 0.29 and 0.41 microg/L as the cinosulfuron equivalent in lysimeters I and II, respectively. The total 14C-radioactivity translocated to rice plants in the third and fourth year was 0.69% and 0.60% (lysimeter I), and 1.02% and 0.84% (lysimeter II) of the 14C applied, respectively. Larger amounts of cinosulfuron equivalents (0.54-0.75%) remained in the straw in the fourth year than in any other parts. The 14C-radioactivities distributed down to a depth of 70 cm after four years were 56.71-57.52% of the 14C applied, indicating the continuous downward movement and degradation of cinosulfuron in soil. The non-extractable residues were more than 88% of the soil radioactivity and some 45-48% of them was incorporated into the humin fraction. The 14C-radioactivity partitioned into the aqueous phase was nearly 30% of the extractable 14C, suggesting strongly that cinosulfuron was degraded into some polar products during the experimental period. It was found out in a supplemental investigation that flooding and constant higher temperature enhanced mineralization of [14C]cinosulfuron to 14CO2 in soil, indicating the possibility of chemical hydrolysis and microbial degradation of the compound in the flooded lysimeter soil.  相似文献   
110.
Kim SC  Jeon SH  Jung IR  Kim KH  Kwon MH  Kim JH  Yi JH  Kim SJ  You JC  Jung DH 《Chemosphere》2001,43(4-7):773-776
Removal efficiencies of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDDs/PCDFs) by air pollution control devices (APCDs) in the commercial-scale municipal solid waste (MSW) incinerators with a capacity of above 200 ton/day were evaluated. The removal efficiencies of PCDDs/PCDFs were up to 95% when the activated carbon (AC) was injected in front of electrostatic precipitator (EP). Spray dryer absorber/bag filter (SDA/BF) had high removal efficiency (99%)) of PCDDs/PCDFs when a mixture of lime and AC was sprayed into the SDA. When the AC was not added in scrubbing solution, the whole congeners of PCDDs/PCDFs were enriched in the wet scrubber (WS) with negative removal efficiencies of -25% to -5731%. Discharge of PCDDs/PCDFs was decreased with increasing the proportions of AC added in scrubbing solution. Selective catalytic reduction (SCR) system had the removal efficiencies of up to 93% during the test operation.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号