全文获取类型
收费全文 | 237篇 |
免费 | 3篇 |
国内免费 | 10篇 |
专业分类
安全科学 | 11篇 |
废物处理 | 24篇 |
环保管理 | 25篇 |
综合类 | 34篇 |
基础理论 | 34篇 |
污染及防治 | 99篇 |
评价与监测 | 17篇 |
社会与环境 | 6篇 |
出版年
2023年 | 1篇 |
2022年 | 1篇 |
2021年 | 4篇 |
2020年 | 2篇 |
2019年 | 4篇 |
2018年 | 8篇 |
2017年 | 9篇 |
2016年 | 10篇 |
2015年 | 9篇 |
2014年 | 8篇 |
2013年 | 24篇 |
2012年 | 7篇 |
2011年 | 25篇 |
2010年 | 19篇 |
2009年 | 21篇 |
2008年 | 17篇 |
2007年 | 19篇 |
2006年 | 11篇 |
2005年 | 9篇 |
2004年 | 13篇 |
2003年 | 4篇 |
2002年 | 11篇 |
2001年 | 7篇 |
2000年 | 1篇 |
1999年 | 1篇 |
1996年 | 1篇 |
1991年 | 1篇 |
1989年 | 1篇 |
1981年 | 1篇 |
1977年 | 1篇 |
排序方式: 共有250条查询结果,搜索用时 671 毫秒
41.
Kinetics and mechanism of TNT degradation in TiO2 photocatalysis 总被引:9,自引:0,他引:9
The photocatalytic degradation of TNT in a circular photocatalytic reactor, using a UV lamp as a light source and TiO(2) as a photocatalyst, was investigated. The effects of various parameters such as the initial TNT concentration, and the initial pH on the TNT degradation rate of TiO(2) photocatalysis were examined. In the presence of both UV light illumination and TiO(2) catalyst, TNT was more effectively degraded than with either UV or TiO(2) alone. The reaction rate was found to obey pseudo first-order kinetics represented by the Langmuir-Hinshelwood model. In the mineralization study, TNT (30 mg/l) photocatalytic degradation resulted in an approximately 80% TOC decrease after 150 min, and 10% of acetate and 57% of formate were produced as the organic intermediates, and were further degraded. NO(-)(3) NO(-)(2), and NH(+)(4) were detected as the nitrogen byproducts from photocatalysis and photolysis, and more than 50% of the total nitrogen was converted mainly to NO(-)(3)in the photocatalysis. However, NO(-)(3) did not adsorbed on the TiO(2) surface. TNT showed higher photocatalytic degradation efficiency at neutral and basic pH. 相似文献
42.
Cho ST Tsai SH Ravindran A Selvam A Yang SS 《Environmental geochemistry and health》2008,30(3):255-272
To investigate the seasonal variations of microbial ecology in grassland of Tatachia forest, soil properties, microbial populations,
microbial biomass, and 16S rDNA clone library analysis were determined. The soil had temperatures 6.6–18.4°C, pH 3.6–5.1,
total organic carbon 1.11–10.68%, total nitrogen 0.18–0.78%, and C/N ratios 3.46–20.55. Each gram of dry soil contained bacteria,
actinomycetes, fungi, cellulolytic, phosphate-solubilizing microbes, and nitrogen-fixing microbes 4.54 × 104 to 3.79 × 107, 3.43 × 102 to 2.17 × 105, 5.74 × 103 to 3.76 × 106, 1.97 × 103 to 1.34 × 106, 8.49 × 102 to 5.59 × 105, and 3.86 × 102 to 3.75 × 105 CFU, respectively. Each gram of soil contained 117–2,482 μg of microbial biomass carbon, 23–216 μg of microbial biomass nitrogen
and 9–29 μg of DNA. The microbial populations, microbial biomass, and DNA decreased stepwise with the depth of soil, and they
had low values in winter seasons. The microbial populations, microbial biomass carbon, microbial biomass nitrogen, and DNA
at the BW2 horizon were 8.42–17.84, 19.26–64.40, 16.84–61.11, and 31.03–46.26% of those at the O horizon, respectively. When
analyzing 16S rDNA library, members of Proteobacteria, Acidobacteria, Actinobacteria, Bacteroidetes, Chloroflexi, Firmicutes,
candidate division TM1, candidate division TM7, Gammatimonadetes, and Verrucomicrobia were identified. Members of Proteobacteria
(44.4%) and Acidobacteria (33.3%) dominated the clone libraries. Within the phylum Proteobacteria, α-, β-, and γ-Proteobacteria
were most numerous, followed by δ-Proteobacteria. 相似文献
43.
Cheol Min Lee Soo Jong Hong Yoon Shin Kim Gee Yong Park Sun Ju Nam Goung Kyung Hwan Kim 《Environmental science and pollution research international》2014,21(2):1146-1152
This research has been conducted continuously since 2009 as part of a cohort of studies examining relationships between asthma and genetic factors, dietary habits, and environmental factors. Based on data from environmental research on house dust mites and endotoxins, which are widely known as pollutants in bedding that cause asthma in pregnant women and children, this work was conducted to obtain basic data that can be used in future cohort studies that analyze links between distribution of biological hazards and physical features of residential environments. The detection rates of house dust mite allergens, Der p1 and Der f1, were 52.7 and 86.5 %, respectively, indicating that Der f1 is a dominant species in domestic indoor environments. According to comparisons between concentrations of house dust mites and endotoxins in bedding of pregnant women and children, Der p1 and endotoxins showed significantly lower concentrations in bedding of pregnant women compared with those in bedding of children, whereas Der f1 showed no significant difference in concentration according to bedding. 相似文献
44.
Chia Hao Hsu Chorng Ming Cho 《Journal of the Air & Waste Management Association (1995)》2013,63(2):246-252
Abstract The removal system for the absorption of CO2 with amines and NH3 is an advanced air pollution control device to reduce greenhouse gas emissions. Absorption of CO2 by amines and NH3 solutions was performed in this study to derive the reaction kinetics. The absorption of CO2 as encountered in flue gases into aqueous solutions of monoethanolamine (MEA), diethanolamine (DEA), and NH3 was carried out using a stirred vessel with a plane gas-liquid interface at 50 °C. Various operating parameters were tested to determine the effect of these variables on the absorption kinetics of the reactants in both gas and liquid phases and the effect of competitions between various reactants on the mass-transfer rate. The observed absorption rate increases with increasing gas-liquid concentration, solvent concentration, temperature, and gas flow rate, but changes with the O2 concentration and pH value. The absorption efficiency of MEA is better than that of NH3 and DEA, but the absorption capacity of NH3 is the best. The active energies of the MEA and NH3 with CO2 are 33.19 and 40.09 kJ/mol, respectively. 相似文献
45.
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (DL-PCBs) were measured in ambient air samples collected from different parts of South Korea in 2008, and the measured levels were used for assessing the spatial and temporal distribution of atmospheric PCDDFs and DL-PCBs in South Korea. The average concentrations of atmospheric PCDD/Fs and DL-PCBs among the 37 sites were 28 fg I-TEQ m−3 (ND ∼ 617) and 1 fg WHO-TEQ m−3 (ND ∼ 0.016). Elevated atmospheric levels of PCDD/Fs and DL-PCBs observed at residential/industrial sites and in the north-west of Korea, indicated a potential contribution and impacts of anthropogenic sources of PCDD/Fs and DL-PCBs. These levels were similar or lower than those previously reported in other ambient air surveys. Average concentrations of PCDD/Fs showed small seasonal variations (ANOVA analysis, p = 0.144). The highest concentrations of PCDD/Fs were observed during winter, followed by spring, autumn and summer. Atmospheric PCDD/Fs and DL-PCBs in South Korea rapidly decreased during the last 10 years (1998-2008), demonstrating the efficiency of stricter regulations and the application of best available technologies/best environmental practices at emission sources. Comparison of the congener profiles and principal component analysis showed that current atmospheric PCDD/Fs are mostly influenced by industrial sources and PCBs from old commercial PCB uses. Nationwide POPs monitoring will continue and allows an effective evaluation of the implementation of the Stockholm Convention on POPs. 相似文献
46.
The effect of polarity on the oxidation of Hg0 was examined in the presence of O2 via a pulsed corona discharge (PCD). The experimental result showed no difference in the energy yield of Hg0 oxidation at both positive and negative PCDs (∼8 μg Hg W h−1 at following conditions: total flow rate = 2 L min−1 (Hg0 = 50 μg N m−3, O2 = 10%, and N2 balance), temperature = 150 °C, and specific energy density = 5-15 W h N m−3). This suggests that the positive PCD process used to control gaseous air pollutants may play an essential key role in Hg0 oxidation because it consumes enough energy (∼15 W h N m−3) but an electrical precipitator could not because it consumes less energy (∼0.3 W h N m−3) to oxidize Hg0. 相似文献
47.
Sung-Won Yoo Young Keun Cho Sang-Hwa Jung Kwang-Myung Lee Seung-Jun Kwon 《Journal of Material Cycles and Waste Management》2017,19(2):694-711
In South Korea, nine million tons of fly ash (FA) are annually produced and approximately 70 % is reutilized for industrial demand. For the prompt reuse and insufficient reclamation site, quality control of FA which is main productive construction material from coal ash is very important. Assessed Pozzolanic-activity Index (API) test which needs only 2 days for evaluation of pozzolanic reaction is currently considered as an alternative of activity index measurement. This paper aims for an applicability of API test for prompt quality control and investigation of domestic FA properties. For the work, FAs from two different power plant types are prepared, and quality tests are carried out based on Korean Standards (KS) methods and API method. Lots of test results are compared with those from API and K-value test for FA with age of 7 days–1 year. From the test results for FA aged 1 year, API results are evaluated to be closely related with those from activity index and K-value, and the correlations are improved with increasing ages regardless of plant types. The applicability of API test is verified and the reduced period of FA quality evaluation can accelerate prompt use and the related process of FA. 相似文献
48.
This study reports on the effect of microwave radiation for inactivation of Ascaris lumbricoides eggs in 25 g of soil compared to ultraviolet irradiation and ozone expose. Microwave radiation at 700 W with 14% water content (w/w) achieved approximately 2.5 log inactivation of eggs in soil within 60 s. On the other hand, UV irradiation at 3 mW cm−2 with and without shaking soil for 3600 s achieved approximately 0.32 and 0.01 log inactivation of eggs, respectively. In ozone treatment, 0.13 log inactivation of eggs was achieved with 5.8 ± 0.7 mg L−1 of dissolved ozone dose for 30 min in a continuous diffusion reactor. In addition, the inactivation of eggs by three disinfection techniques was conducted in water in order to compare the inactivation efficiency of eggs in soil. The inactivation efficiency of microwave radiation was found to be no significant difference between in soil and water. However, the inactivation efficiency of UV irradiation was significantly increased in water while in ozone expose there was no significant difference between in soil and water. Microwave treatment thus proved to be the most efficient method in controlling A. lumbricoides eggs in soil. 相似文献
49.
This paper presents a design method by which the overflow risk related to a detention for managing nonpoint pollutant sources in urban areas can be evaluated. The overall overflow risk of a nonpoint pollutant sources control detention can be estimated by inherent overflow risk and operational overflow risk. For the purpose of calculating overflow risk, the 3-parameter mixed exponential distribution is applied to describe the probability distribution of rainfall event depth. As a rainfall-runoff calculation procedure required for deriving a rainfall capture curve, the U.S. Natural Resources Conservation Service runoff curve number method is applied to consider the nonlinearity of the rainfall-runoff relation. Finally, the detention overflow risk is assessed with respect to the detention design capacity and drainage time. The proposed overflow risk assessment is expected to provide a baseline to determine quantitative parameters in designing a nonpoint sources control detention. 相似文献
50.