排序方式: 共有65条查询结果,搜索用时 203 毫秒
61.
Assessment of heavy metal bioavailability in contaminated sediments and soils using green fluorescent protein-based bacterial biosensors 总被引:2,自引:0,他引:2
A green fluorescent protein (GFP)-based bacterial biosensor Escherichia coli DH5alpha (pVLCD1) was developed based on the expression of gfp under the control of the cad promoter and the cadC gene of Staphylococcus aureus plasmid pI258. DH5alpha (pVLCD1) mainly responded to Cd(II), Pb(II), and Sb(III), the lowest detectable concentrations being 0.1 nmol L(-1), 10 nmol L(-1), and 0.1 nmol L(-1), respectively, with 2h exposure. The biosensor was field-tested to measure the relative bioavailability of the heavy metals in contaminated sediments and soil samples. The results showed that the majority of heavy metals remained adsorbed to soil particles: Cd(II)/Pb(II) was only partially available to the biosensor in soil-water extracts. Our results demonstrate that the GFP-based bacterial biosensor is useful and applicable in determining the bioavailability of heavy metals with high sensitivity in contaminated sediment and soil samples and suggests a potential for its inexpensive application in environmentally relevant sample tests. 相似文献
62.
Technologies such as thermal, oxidative, reductive, and microbial methods for the remediation of polychlorinated biphenyls (PCBs) have previously been reviewed. Based on energy consumption, formation of PCDD/F, and remediation efficiency, reductive methods have emerged as being advantageous for remediation of PCBs. However, many new developments in this field have not been systematically reviewed. Therefore, reductive technologies published in the last decade related to remediation of PCBs will be reviewed here. Three categories, including catalytic hydrodechlorination with H2, Fe-based reductive dechlorination, and other reductive dechlorination methods (e.g., hydrogen-transfer dechlorination, base-catalyzed dechlorination, and sodium dispersion) are specifically reviewed. In addition, the advantages of each remediation technology are discussed. In this review, 108 articles are referenced. 相似文献
63.
Meei‐Fang Shue Ting‐Chien Chen Luzvisminda M. Bellotindos 《Journal of environmental science and health. Part. B》2013,48(6):432-438
This study investigated the concentrations of Tributyltin (TBT) in water, sediment, and fish muscle samples taken from Kaohsiung Harbor and Kaoping River estuary, Taiwan. TBT concentrations in water and sediment samples ranged from less than 18.5 to 34.1 ng Sn L?1 and from 2.44 to 29.7 ng Sn g?1 weight per weight (w/w), respectively. Concentrations in the TBT‐contaminated fish muscle samples ranged from 10.8 to 79.6 ng Sn g?1 w/w. The TBT concentrations in fish muscle were higher than those in water and sediment samples. The fish muscle/water TBT bioconcentration factor (BCF) ranged from 590 to 3363 L kg?1. Additionally, the water samples were assessed for androgenic activity with an MCF7‐AR1 human breast cancer cell line. The androgenic activity ranged from 0.94 to 3.1 ng‐dihydrotestosterone per litre water (ng‐DHT L?1). Higher concentrations of TBT in water and sediment samples occurred in the dry season, but the androgenic activity had higher values in the rainy season. 相似文献
64.
T.W. Chien W.C. Hsu T.K. Tseng C.H. Hsu K.Y. Chen 《Journal of the Air & Waste Management Association (1995)》2013,63(8):1022-1028
Abstract The continuous emission monitoring system (CEMS) can monitor flue gas emissions continuously and instantaneously. However, it has the disadvantages of enormous cost, easily producing errors in sampling periods of bad weather, lagging response in variable ambient environments, and missing data in daily zero and span tests and maintenance. The concept of a predictive emission monitoring system (PEMS) is to use the operating parameters of combustion equipment through thermodynamic or statistical methods to construct a mathematic model that can predict emissions by a computer program. The goal of this study is to set up a PEMS in a gas-fired combined cycle power generation unit at the Hsinta station of Taiwan Power Co. The emissions to be monitored include nitrogen oxides (NOx) and oxygen (O2) in flue gas. The major variables of the predictive model were determined based on the combustion theory. The data of these variables then were analyzed to establish a regression model. From the regression results, the influences of these variables are discussed and the predicted values are compared with the CEMS data for accuracy. In addition, according to the cost information, the capital and operation and maintenance costs for a PEMS can be much lower than those for a CEMS. 相似文献
65.
The US Food and Drug Administration (USFDA) and Environmental Protection Agency (USEPA) are advising women and young children to avoid eating fish that contain high levels of mercury (Hg). However in Taiwan, the annual Black Fin Tuna Festival encourages the public to consume fish. The aim of this study was to assess fish intake in relation to the health risks of mercury exposure and calculate the acceptable and safe intake of fish in children and women of childbearing age. From the Monte Carlo simulation, based on USEPA's reference dose (0.1 microgkg(-1)d(-1)), we found that 21.6%-24.3% and 45.6%-57.4% of the daily mercury dose estimates exceeded the reference dose for typical and high-seafood consumers. The acceptable ingestion rates are <50 g d(-1) (children) and 90.8 +/- 15.7 g d(-1) (women of childbearing). Sensitivity analysis suggests that Hg concentration in fish may be a key parameter to aid governments as they offer guidance for risk management. 相似文献