首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   167篇
  免费   0篇
  国内免费   15篇
安全科学   13篇
废物处理   7篇
环保管理   9篇
综合类   25篇
基础理论   13篇
污染及防治   103篇
评价与监测   8篇
社会与环境   1篇
灾害及防治   3篇
  2021年   3篇
  2020年   1篇
  2019年   1篇
  2018年   6篇
  2017年   6篇
  2016年   5篇
  2015年   1篇
  2014年   6篇
  2013年   31篇
  2012年   9篇
  2011年   12篇
  2010年   5篇
  2009年   6篇
  2008年   9篇
  2007年   10篇
  2006年   10篇
  2005年   12篇
  2004年   8篇
  2003年   6篇
  2002年   12篇
  2001年   14篇
  2000年   3篇
  1999年   1篇
  1997年   1篇
  1995年   1篇
  1994年   1篇
  1993年   1篇
  1976年   1篇
排序方式: 共有182条查询结果,搜索用时 36 毫秒
101.
Pure nano-Al13 and aggregates at various concentrations were prepared to examine the particle size e ect of coagulation with inorganic polymer flocculant. The property and stability of various species formed were characterized using Infrared, 27Al-NMR, photo correlation spectroscopy (PCS), and Ferron assay. Results showed that concentration and temperature exhibited di erent roles on the stability of Al13. The quantity of Alb species analyzed by ferron assay in the initial aging period corresponded well with that of Al13, which has been confirmed in a dimension range of 1–2 nm by PCS. Al13 solutions at high concentrations (0.5–2.11 mol/L) were observed to undergo further aggregation with aging. The aggregates with a wide particle size distribution would contribute to the disappeared/decreased Al13 basis on the 27Al-NMR spectrum, whereas a part of Al13 would still remain as Alb. At low concentrations, Al13 solution was quite stable at normal temperature, but lost its stability quickly when heating to 90°C.  相似文献   
102.
103.
Correlations between raw water characteristics and pH after enhanced coagulation to maximize dissolved organic matter (DOM) removal using four typical coagulants (FeCl3, Al2(SO4)3, polyaluminum chloride (PACl) and high performance polyaluminum chloride (HPAC)) without pH control were investigated. These correlations were analyzed on the basis of the raw water quality and the chemical and physical fractionations of DOM of thirteen Chinese source waters over three seasons. It was found that the final pH after enhanced coagulation for each of the four coagulants was influenced by the content of removable DOM (i.e. hydrophobic and higher apparent molecular weight (AMW) DOM), the alkalinity and the initial pH of raw water. A set of feed-forward semi-empirical models relating the final pH after enhanced coagulation for each of the four coagulants with the raw water characteristics were developed and optimized based on correlation analysis. The established models were preliminarily validated for prediction purposes, and it was found that the deviation between the predicted data and actual data was low. This result demonstrated the potential for the application of these models in practical operation of drinking water treatment plants.  相似文献   
104.
The Fresno Supersite intends to 1) evaluate non-routine monitoring methods, establishing their comparability with existing methods and their applicability to air quality planning, exposure assessment, and health effects studies; 2) provide a better understanding of aerosol characteristics, behavior, and sources to assist regulatory agencies in developing standards and strategies that protect public health; and 3) support studies that evaluate relationships between aerosol properties, co-factors, and observed health end-points. Supersite observables include in-situ, continuous, short-duration measurements of 1) PM2.5, PM10, and coarse (PM10 minus PM2.5) mass; 2) PM2.5 SO4(-2), NO3-, carbon, light absorption, and light extinction; 3) numbers of particles in discrete size bins ranging from 0.01 to approximately 10 microns; 4) criteria pollutant gases (O3, CO, NOx); 5) reactive gases (NO2, NOy, HNO3, peroxyacetyl nitrate [PAN], NH3); and 6) single particle characterization by time-of-flight mass spectrometry. Field sampling and laboratory analysis are applied for gaseous and particulate organic compounds (light hydrocarbons, heavy hydrocarbons, carbonyls, polycyclic aromatic hydrocarbons [PAH], and other semi-volatiles), and PM2.5 mass, elements, ions, and carbon. Observables common to other Supersites are 1) daily PM2.5 24-hr average mass with Federal Reference Method (FRM) samplers; 2) continuous hourly and 5-min average PM2.5 and PM10 mass with beta attenuation monitors (BAM) and tapered element oscillating microbalances (TEOM); 3) PM2.5 chemical speciation with a U.S. Environmental Protection Agency (EPA) speciation monitor and protocol; 4) coarse particle mass by dichotomous sampler and difference between PM10 and PM2.5 BAM and TEOM measurements; 5) coarse particle chemical composition; and 6) high sensitivity and time resolution scalar and vector wind speed, wind direction, temperature, relative humidity, barometric pressure, and solar radiation. The Fresno Supersite is coordinated with health and toxicological studies that will use these data in establishing relationships with asthma, other respiratory disease, and cardiovascular changes in human and animal subjects.  相似文献   
105.
During the last 10 years, high atmospheric concentrations of airborne particles recorded in the Mexico City metropolitan area have caused concern because of their potential harmful effects on human health. Four monitoring campaigns have been carried out in the Mexico City metropolitan area during 2000-2002 at three sites: (1) Xalostoc, located in an industrial region; (2) La Merced, located in a commercial area; and (3) Pedregal, located in a residential area. Results of gravimetric and chemical analyses of 330 samples of particulate matter (PM) with an aerodynamic diameter less than 2.5 microm (PM2.5) and PM with an aerodynamic diameter less than 10 microm (PM10) indicate that (1) PM2.5/PM10 average ratios were 0.42, 0.46, and 0.52 for Xalostoc, La Merced, and Pedregal, respectively; (2) the highest PM2.5 and PM10 concentrations were found at the industrial site; (3) PM2.5 and PM10 concentrations were lower at nighttime; (4) PM2.5 and PM10 spatial averages concentrations were 35 and 76 microg/m3, respectively; and (5) when the PM2.5 standard was exceeded, nitrate, sulfate, ammonium, organic carbon, and elemental carbon concentrations were high. Twenty-four hour averaged PM2.5 concentrations in Mexico City and Sao Paulo were similar to those recorded in the 1980s in Los Angeles. PM10 concentrations were comparable in Sao Paulo and Mexico City but 3-fold lower than those found in Santiago.  相似文献   
106.
Particle light scattering and PM2.5 (particles with aerodynamic diameters less than 2.5 m) concentration data from air quality studies conducted over the past ten years wereexamined. Fine particle scattering efficiencies were determinedfrom statistical relationships among measured light scattering and fine and coarse mass concentrations. The resulting fine particle scattering efficiencies ranged from 1.7 m2 g-1at Meadview in the Grand Canyon to over 5 m2 g-1 in Mexico City. Most of the derived fine scattering efficiencieswere centered around 2 m2 g-1, which is considerablylower than most values reported from previous studies.  相似文献   
107.
The Southern California Air Quality Study (SCAQS) was conducted during the summer and fall of 1987 to assess the causes of elevated ozone and suspended particulate matter concentrations in California's South Coast Air Basin (SoCAB). Extensive gaseous (i.e. nitric acid, ammonia, sulfur dioxide) and particle (i.e. PM2.5 and PM10 mass, elements, ions, carbon) measurements were acquired for 11 days during the summer at nine locations, and six days during the fall at six locations. Outliers were identified so that they could be excluded from further statistical analyses. Carbon and elemental measurements were found to be negatively biased by 20% owing to inhomogenous aerosol deposits on the SCAQS filters and analysis methods which were applied to a portion of the filters. These biases seem relatively consistent, however, and should not affect conclusions drawn from data analysis efforts if they are appropriately considered. Significant fractions (30–60%) of ammonium nitrate volatilized during the summer when temperatures were higher. Less than 10% typically volatilized during the fall when temperatures were lower. Anion/cation balances support the accuracy and precision estimates of the nitrate, sulfate, and ammonium measurements. Coarse particle sulfate was generally low, while coarse particle nitrate was most pronounced at the coastal sites.This paper documents SCAQS filter-based aerosol measurement methods, and evaluates the accuracy, precision, and validity of the data set. Various comparisons were made for: (1) PM2.5/PM10 ratios for mass and major chemical species; (2) sum of chemical species versus measured mass; (3) sulfate versus sulfur ratios; (4) PM2.5 particulate nitrate versus nitric acid-denuded nitrate; and (5) anion/cation balances. The measurement and evaluation techniques presented in this paper serve as a guideline for other data analysis and modeling studies.  相似文献   
108.
This study examined the associations between dissolved organic matter(DOM) characteristics and potential nitrification occurrence in the presence of chloramine along a drinking water distribution system. High-performance size exclusion chromatography(HPSEC) coupled with a multiple wavelength detector(200–280 nm) was employed to characterise DOM by molecular weight distribution, bacterial activity was analysed using flow cytometry, and a package of simple analytical tools, such as dissolved organic carbon, absorbance at 254 nm, nitrate,nitrite, ammonia and total disinfectant residual were also applied and their applicability to indicate water quality changes in distribution systems were also evaluated. Results showed that multi-wavelength HPSEC analysis was useful to provide information about DOM character while changes in molecule weight profiles at wavelengths less than 230 nm were also able to be related to other water quality parameters. Correct selection of the UV wavelengths can be an important factor for providing appropriate indicators associated with different DOM compositions. DOM molecular weight in the range of 0.2–0.5 k Da measured at210 nm correlated positively with oxidised nitrogen concentration(r = 0.99), and the concentrations of active bacterial cells in the distribution system(r = 0.85). Our study also showed that the changes of DOM character and bacterial cells were significant in those sampling points that had decreases in total disinfectant residual. HPSEC-UV measured at210 nm and flow cytometry can detect the changes of low molecular weight of DOM and bacterial levels, respectively, when nitrification occurred within the chloraminated distribution system.  相似文献   
109.
三个机场候机厅的火灾安全分区评述   总被引:1,自引:1,他引:0  
S.W.Im  W.K.Chow 《火灾科学》2001,10(3):184-192
通过参观机场对公众开放的区域,对三个机场侯机厅的火灾安全分区进行了评述,这三个机场是,香港的旧启德机场,澳大利亚的悉尼机场和墨尔本机场,指出了一般的被动建筑设计和积极的火灾防护系统,按照估计的火灾载葆密度对零售区域商店的形状和商品进行了记录,利用消防工程计算程序FIRECALC对三种水喷头的启动时间进行了预测。  相似文献   
110.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号