城市垃圾预处理改善焚烧特性的探讨 总被引:3,自引:0,他引:3
针对目前我国城市垃圾的高水分、低热值的特性,提出了2种改善城市垃圾焚烧特性的有效措施:生物质垃圾源分类和生物干燥.在我国建立生物质垃圾源分类体系,将生物质垃圾源头分类后,剩余垃圾的热值可以提高约50%~120%,已适合直接入炉焚烧,同时分离出来的生物质垃圾也更易于好氧堆肥或厌氧消化.另外一项技术措施是在焚烧前利用生物干燥技术,降低城市垃圾的水分含量,提高入炉垃圾的热值,这种方法主要是利用生物反应热来干燥城市生活垃圾,只需要在垃圾投入焚烧炉前增加一个预处理步骤,不必改变目前的垃圾收运体系,而且进行生物干燥后的垃圾更易于分选其中的可回收物质. 相似文献
2.
开发了一种新型连续进料全混合式厨余垃圾生物干化工艺,通过中试试验探究了该工艺运行效能及其对物料温度、含水率和热值的影响规律.结果表明,该工艺可显著缩短升温时间,维持物料>50℃的高温区段20h/d;在最佳运行条件(通风速率0.171m3/(kg·h),最低控制温度45℃,干化周期7d)下,厨余垃圾含水率可降至(34.86±1.71)%,水分单位去除量达(716±23) kg水/t垃圾,运行能耗仅为77.91kW·h/t垃圾,低位热值高达(6681±119) kJ/kg,满足垃圾焚烧进炉要求,可有效实现厨余垃圾快速衍生燃料化. 相似文献
3.
Biodrying of municipal solid waste with high water content by combined
hydrolytic-aerobic technology 总被引:1,自引:1,他引:0
The high water content of municipal solid waste(MSW)will reduce the effciency of mechanical sorting,consequently unfavorable for beneficial utilization.In this study,a combined hydrolytic-aerobic biodrying technology was introduced to remove water from MSW.The total water removals were proved to depend on the ventilation frequency and the temporal span in the hydrolytic stage. The ventilation frequency of 6 times/d was preferable in the hydrolytic stage.The hydrolytic span should not be prolonged more than ... 相似文献
4.
F. J. Colomer-Mendoz L. Herrera-Prats F. Robles-Martnez A. Gallardo-Izquierdo A. B. Pia-Guzmn 《环境科学学报(英文版)》2013,25(5):865-872
Biodrying consists of reducing moisture by using the heat from aerobic bio-degradation.The parameters that control the process are:aeration,temperature during the process,initial moisture of biowaste,and temperature and relative humidity of the input air.Lawn mowing and garden waste from the gardens of the University Jaume I,Castellón(Spain)were used as a substrate.Biodrying was performed in 10 reactors with known air volumes from 0.88 to 6.42 L/(min·kg dry weight).To promote aeration,5 of the reactors had 15% of a bulking agent added.The experiment lasted 20 days.After the experiments it was found that the bulking agent led to greater weight loss.However,the increased airflow rate was not linearly proportional to the weight loss. 相似文献
5.
6.
7.
调理剂和通风方式对污泥生物干化效果的影响 总被引:6,自引:2,他引:4
采用了自主设计的污泥生物干化实验室模拟系统,研究了调理剂、物料配比和通风方式等实验条件对脱水污泥生物干化的影响效果。研究结果表明,与锯末相比,秸秆有利于反应物料温度的上升,含水率下降程度更大;利用秸秆调节污泥初始含水率在60%和65%的实验条件下时,物料的平均含水率分别下降了7%和6%,当初始含水率65%时,生物堆体的温度和含水率没有明显的变化;与连续通风相比较,间歇通风的实验条件有利于生物堆体的温度的升高和干化效果;在该实验中,最佳的生物干化条件是以秸秆为调理剂,初始含水率调至65%以下,以间歇方式进行通风。 相似文献
8.
通风强度对市政污泥生物干化中试效果的影响 总被引:1,自引:1,他引:0
将污泥与树皮按照一定比例混合,利用自主研制的滚筒式污泥生物干化中试系统进行实验,通过对温度、含水率、O2和CO2浓度、挥发性固体(VS)、p H等参数的检测,研究了通风强度对市政污泥生物干化效果的影响.结果表明,通风强度对污泥生物干化有较大影响,通风强度(以VS计)为120 L·(h·kg)-1时,最高温度达到66℃,55℃以上高温可以维持40 h以上,111 h后污泥最终含水率可以降低至56%;生物干化过程中p H始终保持在6.5~8.5之间,不会影响微生物生命活动;滚筒式污泥生物干化反应器能够使反应器内基质均一性良好,对利用滚筒式反应器实现污泥连续流处理提供参考. 相似文献