首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   105篇
  免费   0篇
  国内免费   1篇
安全科学   10篇
废物处理   2篇
环保管理   5篇
综合类   6篇
基础理论   9篇
污染及防治   49篇
评价与监测   15篇
社会与环境   9篇
灾害及防治   1篇
  2023年   2篇
  2022年   2篇
  2021年   3篇
  2019年   3篇
  2018年   6篇
  2017年   7篇
  2016年   6篇
  2015年   4篇
  2014年   6篇
  2013年   18篇
  2012年   4篇
  2011年   8篇
  2010年   1篇
  2009年   2篇
  2008年   5篇
  2007年   2篇
  2006年   3篇
  2005年   3篇
  2004年   3篇
  2003年   6篇
  2002年   4篇
  2001年   2篇
  2000年   2篇
  1999年   1篇
  1992年   1篇
  1964年   1篇
  1931年   1篇
排序方式: 共有106条查询结果,搜索用时 19 毫秒
1.
This work aims to assess the spatial distribution and concentration of sulfur in the topsoil layer and to determine the relationships between sulfur concentration, soil pH, soil electrical conductivity, and plant cover at the reforested site of the former sulfur mine (Southern Poland). Soil samples were collected from 0 to 20 cm (topsoil) from a total of 86 sampling points in a regular square grid with sides of 150 m. Plant cover was assayed in circular plots with an area of 100 m2, divided into a woody plant layer and herbaceous plant layer. Soil properties such as particle size distribution, pH in KCl and H2O, soil electrical conductivity (EC), soil organic carbon (SOC), total nitrogen (NT), and total sulfur (ST) were determined. The degree of soil contamination with sulfur was assessed based on the guidelines of the Institute of Soil Science and Plant Cultivation (IUNG), Poland. The results indicate that remediation and application of lime were not fully effective in spatial variation, because 33 points with sulfur contamination above 500 mg kg?1 were observed. These spots occurred irregularly in the topsoil horizons. This high sulfur concentration in the soil did not result in severe acidification (below 4.5) in all cases, most likely due to neutralization from the application of high doses of flotation lime. High vegetative cover occurred at some points with high soil sulfur concentrations, with two points having S concentration above 40,000 mg kg?1 and tree cover about 60%. Numerous points with high soil EC above 1500 μS cm?1 as well as limited vegetation and high soil sulfur concentrations, however, indicate that the reclamation to forest is still not completely successful.  相似文献   
2.
Environmental Science and Pollution Research - Phthalate esters (PAEs) are endocrine disrupters and can disrupt the functioning of different hormones, causing adverse effects on human health. Due...  相似文献   
3.
The aim of the study was to compare radon concentrations in neighbouring hospital buildings which were constructed in different years during the period 1963-2000 and are located in areas with similar radon potential. The value of arithmetic mean (AM) radon concentration in soil gas amounted to 14,464 Bq m(-3). In a hospital built 40 years ago, the AM radon concentration in the cellar was 38.4+/-36.7 Bq m(-3) and on higher levels it was 17.1+/-10.3 Bq m(-3). In a hospital built 16 years ago, these values equaled 45.5+/-47.2 Bq m(-3) and 20.4+/-12.5 Bq m(-3), respectively. In the newest hospital, built three years ago, radon concentration (AM) in a cellar was 32.3+/-27.4 Bq m(-3) and the respective value on higher levels amounted to 20.4+/-12.6 Bq m(-3). When comparing radon concentrations in the cellars, no statistically significant differences were found. Similarly, no statistically significant differences were observed between radon concentrations measured on higher levels in investigated hospital buildings.  相似文献   
4.
In the course of researches into radon occurrence in the groundwaters of the Polish part of the Sudety Mountains, conducted in various research centres in Poland, almost 1000 radon concentration determinations have been collected. These results have given the basis for an attempt to characterise the groundwaters of this region with respect to radon content. Radon concentrations oscillated within the range of 0.2-1645 Bq/dm3, with the arithmetic mean at 240.0 Bq/dm3 and the geometric mean at 106.7 Bq/dm3. The largest number of radon concentrations found in the Sudetic groundwaters ranged between ca. 3-6 and 1000 Bq/dm3. The values over 1000 Bq/dm3 can be considered anomalously high. They constitute 3.9% of all the results and occur around six localities within different geological units of the Sudety Mountains. These are shallow circulation, low mineralised groundwaters, which outflow from gneisses and granites. In the face of the fact that from 12.8% to 72.7% (depending on the adopted norm of maximum radon concentration for drinking waters) of the examined waters cannot be drunk directly without removing at least part of the radon, and in the face of the possibility of recognizing as many as 63.5% of the waters as potentially medicinal, extensive research of radon geochemistry in the Sudety Mountains area should be urgently undertaken.  相似文献   
5.
Because they are used in a number of commercial preparations phenoxyacetic acids and their salts can occur in wastewater. During their degradation genotoxic substances may be created. The results of investigations of biodegradability and genotoxicity of some phenoxyherbicides are presented. Commercial formulations of 2,4-D (Aminopielik 720) and MCPA (Chwastox Extra) were the substrates studied. Biodegradation tests were conducted according to OECD guidelines for testing of chemicals--confirmatory test (OECD Method 303 A). Genotoxicity tests were conducted with Bacillus subtilis strains according to the method of [Chemical Mutagens, vol. 6, Plenum Press. New York, 1980, p. 149]. Genotoxicity of biodegradation products was also studied. Both commercial formulations were biodegradable. Aminopielik 720 was potentially genotoxic but only at great concentrations while Chwastox Extra was not genotoxic. Biodegradation products of neither compound were genotoxic.  相似文献   
6.
The aim of this work was to make a comparison of indoor radon concentrations in dwellings and in soil air in the area of two geological formations in the Suwa?ki region (Poland). The mean arithmetic airborne concentration was found to be the highest (301 Bq m (-3)) in the basements of buildings in the gravel and sand areas, whereas in the boulder clay areas it reached 587 Bq m (-3). Out of 54 measurements of radon concentrations performed at the ground floor, in eight cases concentrations were found to exceed 200 Bq m (-3) - permissible radon level in new-built houses in Poland and in three cases these values were even higher than 400 Bq m (-3). The highest radon levels were noted in houses with earthen basement floors and with direct entrance from the basement to rooms or kitchens. The mean arithmetic radon concentration in the soil air in the sandy and gravel formations was 39.7 kBq m (-3) and in clay formation it was 26.5 kBq m (-3). Higher radon levels were also found in the water obtained from household wells reaching 8367 Bq m (-3) as compared with tap water (2690 Bqm (-3)). The mean indoor concentration for the whole area under study was found to be 169.4 Bq m (-3), which is higher than the mean value for Poland (49.1 Bq m (-3)) by a factor of 3.5.  相似文献   
7.
The self-organising map approach was used to assess the efficiency of chlorinated solvent removal from petrochemical wastewater in a refinery wastewater treatment plant. Chlorinated solvents and inorganic anions (11 variables) were determined in 72 wastewater samples, collected from three different purification streams. The classification of variables identified technical solvents, brine from oil desalting and runoff sulphates as pollution sources in the refinery, affecting the quality of wastewater treatment plant influent. The classification of samples revealed the formation of five clusters: the first three clusters contained samples collected from the drainage water, process water and oiled rainwater treatment streams. The fourth cluster consisted mainly of samples collected after biological treatment, and the fifth one of samples collected after an unusual event. SOM analysis showed that the biological treatment step significantly reduced concentrations of chlorinated solvents in wastewater.  相似文献   
8.
In this study, graphene oxide (GO) has been applied as a matrix for enzyme immobilization. The protein adsorption capacity of GO is much higher than of other large surface area carbonaceous materials. Its structure and physicochemical properties are reported beneficial also for enzymatic activity modifications. The experimental proof was done here that GO-based biocatalytic systems with immobilized catalase are modifiable in terms of catalyzed reaction kinetic constants. It was found that activity and stability of catalase, considered here as model enzyme, closely depend on enzyme/GO ratio. The changes in kinetic parameters can be related to secondary structure alterations. The correlation between enzyme/GO ratio and kinetic and structure parameters is reported for the first time and enables the conscious control of biocatalytic processes and their extended applications. The biological activity of obtained biocatalytic systems was confirmed in vitro by the use of functional test. The addition of immobilized catalase improved the cells’ viability after they were exposed to hydrogen peroxide and tert-butyl-hydroperoxide used as source of reactive oxygen species.  相似文献   
9.
A simple method for species-selective analysis of organotin compounds (OTCs) (butyl and phenyl) in sediments was developed. The sample preparation procedure was specifically optimised for sulphur-rich sediments to eliminate interferences from elemental sulphur and organosulphur compounds. Tin species were extracted from sediment samples using pressurised liquid extraction technique (PLE), ethylated - with simultaneous extraction to isooctane - in aqueous phase with sodium tetraethylborate (NaBEt(4)) and separated/detected by gas chromatography with flame photometric detection (GC-FPD). PLE operational variables (extraction temperature and pressure, solvent composition and number of static extraction steps) and extract handling routine were fine-tuned to minimise the amount of extracted interferents while keeping OTCs recovery at an acceptable level. Best results were obtained after extraction of sediment samples with methanol/water (75% v/v methanol) solution of acetic acid/sodium acetate with tropolone addition (0.6 g l(-1)). Derivatisation of low temperature, high-pressure (50 degrees C, 13.8 MPa) extracts gives isooctane extracts which are clean enough to be directly analysed by GC-FPD without any further cleanup. Interferences from elemental sulphur were completely eliminated while concentrations of other interferents were reduced to the level not impairing quantitation of OTCs under the study. No negative effects in terms of chromatographic column deterioration were observed after repeated injections of such extracts. Two certified reference materials, BCR646 and PACS-2, were analysed to assess performance of the method. Recoveries of all OTCs under the study, except MBT, were in the range of 91-114%. MBT extraction efficiency was low (34-47%) therefore the method is unsuitable for precise determinations of this compound.  相似文献   
10.
This paper demonstrates the ability of Polish agriculture to adapt to predicted climate change according to GISS and GFDL scenarios. Both climate-change scenarios will significantly affect farming conditions in Poland through water deficit, shifts in planting and harvesting seasons, changes in crop yields and crop structure. Neither scenario seems to endanger the self-sufficiency of Poland as long as preventative measures are taken. Moreover, the realization of GISS creates the possibility of a surplus in production. It must be emphasized that regardless of the scenario, the adaptation of agriculture to an expected climate change cannot be handled by the farming community itself.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号