首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   0篇
废物处理   1篇
污染及防治   1篇
评价与监测   2篇
  2023年   1篇
  2000年   2篇
  1992年   1篇
排序方式: 共有4条查询结果,搜索用时 15 毫秒
1
1.
Variations in precipitation chemistry between and within rain events have been examined in order to identify possible relationships with synoptic, mesoscale and micrometeorological processes. A microprocessor-based acid rain monitor was used to provide high resolution meteorological and rain chemistry data from which two case study events have been selected to illustrate event and sub-event rainfall chemistry characteristics. Event rainfall chemistry is strongly influenced by the history of the prevailing air mass and the synoptic situation. From back trajectories calculated at the 950 mbar level it is clear that air mass history can change markedly within a few hours. These observations emphasise the value of high resolution rainfall chemistry measurements. Pollutant concentrations in rainwater have been shown to fluctuate markedly within the course of individual events as a result of both advective and scavenging processes. Advective effects may result from: (a) air mass discontinuities at frontal zones; and/or (b) variable rainfall interception of the air mass prior to arrival at the site. A simple mathematical model has been developed to describe the scavenging mechanisms and it shows good agreement with field observations. Theoretical considerations suggest that in-cloud processes give rise to most of the observed decline in concentrations.  相似文献   
2.
Five different instruments for the determination of the mass concentration of PM10 in air were compared side-by-side for up to 33 days in an undisturbed indoor environment: a tripod mounted BGI Inc. PQ100 gravimetric sampler with a US EPA certified Graseby Andersen PM10 inlet; an Airmetrics Minivol static gravimetric sampler; a Casella cyclone gravimetric personal sampler; an Institute of Occupational Medicine gravimetric PM10 personal sampler; and two TSI Inc. Dustrak real-time optical scattering personal samplers. For 24 h sampling of ambient PM10 concentrations around 10 microg m(-3), the estimated measurement uncertainty for the two gravimetric personal samplers was larger (approximately +/- 20%) compared with estimated measurement uncertainty for the PQ100/Graseby Andersen sampler (< +/- 5%). Measurement uncertainty for the Dustraks was lower (approximately +/- 15% on average) but calibration of the optical response against a reference PM10 method is essential since the Dustraks systematically over-read PM10 determined gravimetrically by a factor approximately 2.2. However, once calibrated, the Dustrak devices demonstrated excellent functionality in terms of ease of portability and real-time data acquisition. Estimated measurement uncertainty for PM10 concentrations determined with the Minivol were +/- 5%. The Minivol data correlated well with PQ100/Graseby Andersen data (r= 0.97, n = 18) but were, on average, 23% greater. The reason for the systematic discrepancy could not be traced. Intercomparison experiments such as these are essential for assessing measurement error and revealing systematic bias. Application of two Dustraks demonstrated the spatial and temporal variability of exposure to PM10 in different walking and transport microenvironments in the city of Edinburgh, UK. For example, very large exposures to PM10 were identified for the lower deck of a double-decker tour bus compared with the open upper deck of the same vehicle. The variability observed emphasises the need to determine truly personal exposure profiles of PM10 for quantifying exposure response relationships for epidemiological studies.  相似文献   
3.

To create a truly circular economy requires a shift from the traditional view of waste disposal to one of resource management. This is particularly important in developing countries, where municipal waste generation is increasing, and efficient recovery of economic value from waste is rarely achieved. Conducted in the University of Lagos (UoL), Nigeria, this study investigated the efficiency of a recycling scheme with the goal of making recommendations to improve the process. UoL’s recycling policy centers around source segregation of waste into color-coded bins. Waste audit was carried out using the output method and interviews were conducted with staff from the waste management team to understand practices on campus. Substantial contamination of colored bins with non-target material was observed. Organics (30%), mixed plastics (28%) and paper (24%) were the most abundant materials, hence have the greatest potential for recovery, and income generation, if segregation rates could be improved. Despite its recycling policy and infrastructure, 99% of UoL waste was going to landfill. Poor policy implementation results in low recovery rates. Targeted waste reduction and increased material recovery would enhance efficiency. Improved awareness of recycling benefits, in addition to policy enforcement, could serve as tools to increase stakeholder participation in recycling.

  相似文献   
4.
By extending the method of Stedman (1998), daily dataof atmospheric concentrations of gravimetricPM10, black smoke (BS) and sulphate aerosol (SA)from national networks were analysed to determine thetrends in time of the contribution of different sources of particulate matter to total PM10 measured in central Edinburgh. Since BS is an indicator of combustion-related primary sources of particulate matter, the quantity obtained by subtraction of daily BS from daily PM10 is indicative of the contribution to total PM10 from other primary sources and from secondary aerosol. This PM10-BS statistic was regressed on SA, since SA is an indicator of variation in secondary aerosol source. For Edinburgh, SA is a considerably better indicator of PM10-BS during summer than winter (reflecting the much greater photochemical generation of secondary aerosol in summer) and there is evidence that the contribution of other secondary aerosol (presumably nitrate aerosol) has increased relative to SA between 1992 and 1997. The concentration of non-combustion primary particulate material (marine aerosol, suspended dust) to PM10 in Edinburgh has not changed over this period but is about twice that calculated as the U.K. national average. The increasing input to PM10 from secondary aerosol sources at regional rather than urban scale has important implications for ensuring local air quality compliance. The method should have general applicability to other locations.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号