首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   102篇
  免费   0篇
  国内免费   2篇
安全科学   9篇
废物处理   6篇
环保管理   1篇
综合类   18篇
基础理论   17篇
污染及防治   35篇
评价与监测   12篇
社会与环境   5篇
灾害及防治   1篇
  2022年   2篇
  2021年   3篇
  2019年   1篇
  2018年   3篇
  2017年   1篇
  2016年   3篇
  2015年   5篇
  2014年   8篇
  2013年   8篇
  2012年   9篇
  2011年   7篇
  2010年   5篇
  2009年   4篇
  2008年   7篇
  2007年   12篇
  2006年   4篇
  2005年   6篇
  2004年   4篇
  2003年   3篇
  2001年   2篇
  2000年   1篇
  1999年   1篇
  1995年   2篇
  1986年   1篇
  1983年   2篇
排序方式: 共有104条查询结果,搜索用时 15 毫秒
1.
Poly(butylene succinate) (PBS) was melt blended with glycerol based polyesters (PGS) synthesized from pure and technical glycerol aiming to improve the impact strength of PBS. It was found that after addition of 30 wt% PGS to PBS its impact strength was significantly increased by 344% (from 31.9 to 110 J/m) and its elongation at break was maintained at 220%. Infrared spectra of the blends showed the presence of hydroxyl groups from the PGS phase suggesting that hydrogen bonding between the phases could be responsible for a good stress transfer and an efficient toughening in the PBS/PGS blends. Scanning electron microscopy imaging showed a good dispersion of PGS phase into PBS with a PGS particle size of 10 μm and less and no agglomeration. Addition of PGS to PBS was shown to be an effective strategy for improvement of PBS impact resistance without serious detrimental effects on its thermal and rheological properties.  相似文献   
2.
With its potential for low (if any) disinfection byproduct formation and easy retrofit for chlorine contactors, peracetic acid (PAA) or use of PAA in combination with other disinfectant technologies may be an attractive alternative to chlorine-based disinfection. Examples of systems that might benefit from use of PAA are water reuse schemes or plants discharging to sensitive receiving water bodies. Though PAA is in use in numerous wastewater treatment plants in Europe, its chemical kinetics, microbial inactivation rates, and mode of action against microorganisms are not thoroughly understood. This paper presents results from experimental studies of PAA demand, PAA decay, and microbial inactivation, with a complementary modeling analysis. Model results are used to evaluate techniques for measurement of PAA concentration and to develop hypotheses regarding the mode of action of PAA in bacterial inactivation. Kinetic and microbial inactivation rate data were collected for typical wastewaters and may be useful for engineers in evaluating whether to convert from chlorine to PAA disinfection.  相似文献   
3.
The present study focuses on the definition and assessment of overpressure threshold values for the damage to equipment caused by blast waves originated by primary accidental scenarios. A revision of literature data and of the available damage probability models was carried out. Threshold values were proposed for different categories of process equipment, taking into account either damage levels or release intensities following the loss of containment. Specific threshold values for domino effect were also proposed.  相似文献   
4.
Environmental Geochemistry and Health - The results of a large geochemical study on various environmental media (soil, stream sediment, groundwater, surface water, lettuce and human hair) of the...  相似文献   
5.
The first survey of persistent organic pollutant (POP) concentrations in air across several Indian agricultural regions was conducted in 2006-2007. Passive samplers comprising polyurethane foam (PUF) disks were deployed on a quarterly basis at seven stations in agricultural regions, one urban site and one background site. The project was conducted as a sub-project of the Global Atmospheric Passive Sampling (GAPS) Network. In addition to revealing new information on air concentrations of several organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs), the study has demonstrated the feasibility of conducting regional-scale monitoring for POPs in India using PUF disk samplers. The following analytes were detected with relatively high concentrations in air (mean for 2006 and 2007, pg/m3): α- and γ-hexachlorocyclohexane (HCH) (292 and 812, respectively); endosulfan I and II (2770 and 902, respectively); p,p′-DDE and p,p′-DDT (247 and 931, respectively); and for the sum of 48 PCBs, 12,100 (including a site with extremely high air concentrations in 2007) and 972 (when excluding data for this site).  相似文献   
6.
A study of the impact of two flood control reservoirs and pollution influx was conducted on two streams within the Sandy Creek Watershed, Mercer County, Pennsylvania, USA. Fecal coliforms were significantly reduced in the outflows without affecting water chemistry, thereby improving the overall water quality. The size and composition of the aquatic communities as well as stream metabolism varied seasonably among the different sampling stations. Pollution influx primarily from communities and agricultural drainage had a greater impact on the stream ecosystem than did impounding of the streams. Natural wetlands and riparian vegetation were important factors in reducing the pollution load in these streams. The reestablishment and maintenance of riparian vegetation should therefore be an integral part of the land-use plan for watersheds in order to improve water quality and wildlife habitats. In the future, the maintenance of riparian vegetation should be given prime consideration in the development of watershed projects.  相似文献   
7.
The electrochemical oxidation is a promising process for organic pollutants which are recalcitrant to biological degradation. The anodic oxidation of 1,5-naphthalenedisulfonic acid, hereafter NDS, was evaluated at a Pt anode using in situ generated Ag(II) cation or peroxydisulfate [S2O(8)(2-)] anion as mediators. Kinetics of the direct chemical oxidation of NDS in the presence of Na2S2O8, and the identification of some oxidation intermediates are also reported. An analysis of the results shows that Ag(II) is characterized by a high-reaction rates, while [S2O(8)(2-)] performs the oxidation of NDS in a complete way.  相似文献   
8.
An investigation was conducted to estimate the effectiveness of air bags as a function of velocity. The study consisted of three parts: a theoretical idealization, an analysis of National Automotive Sampling System/Crashworthiness Data System (NASS/CDS), and a reanalysis of previously published Fatality Analysis Reporting System (FARS) data. The theoretical analysis looked at idealized risk curves as a function of velocity; assuming that the air bag offers a benefit for both belted and unbelted occupants. Analysis of the NASS/CDS data looked at the effectiveness of air bags as a function of velocity for Maximum Abbreviated Injury Scale (MAIS) 3+ injuries. The reanalysis of the previously published FARS data looked at the effectiveness of the air bag as a function of velocity for fatalities. The theoretical analysis indicates that the air bag effectiveness should be greatest at the low velocities. The field data analysis of both NASS/CDS and FARS were consistent with the theoretical analysis, indicating that air bags are most effective at the lower velocities, below 40 kph (25 mph), for both belted and unbelted occupants. Although it was not possible to estimate a different effect for belted and unbelted for fatalities using FARS, it was possible for MAIS 3+ using NASS/CDS. For unbelted occupants the effectiveness goes to zero or becomes negative above 40 kph (25 mph) for MAIS 3+, and for belted occupants the effectiveness stays positive but with significantly lower magnitude for speeds above 40 kph (25 mph).  相似文献   
9.
A European standard for the determination of Cr(vi) in solid material has been elaborated in the framework of an international co-operation and finally validated in the course of an interlaboratory comparison. The procedure is based on the alkaline digestion prescribed by EPA method 3060A followed by ion chromatography and determines an operationally defined content of Cr(vi), including water-soluble and insoluble chromates. A preliminary robustness study was carried out in order to compare different extraction methodologies and to study the equivalency of different analytical methods for the determination of Cr(vi) in alkaline extracts of soil and waste materials. During an interlaboratory validation trial with 19 European laboratories a set of 4 samples (2 soil and 2 waste samples) was analysed to determine performance characteristics for different combinations of digestion and detection methods. With the procedures prescribed by the new European standard (EN 15192) acceptable results were obtained for both soil samples and one of the waste samples (sludge). However, for the second waste sample (fly ash) a large deviation in analytical results was observed. This indicates that particularly for waste materials a possible occurrence of strong matrix effects has to be considered and supplementary quality control data are needed in order to assess the validity of analytical results. The accuracy of the determination of Cr(vi) in solid matrices remains a challenging field in terms of maximum extraction efficiency and minimum species interconversion.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号