首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
安全科学   2篇
环保管理   1篇
综合类   1篇
污染及防治   1篇
评价与监测   1篇
  2019年   1篇
  2017年   1篇
  2013年   1篇
  2009年   1篇
  2008年   1篇
  1990年   1篇
排序方式: 共有6条查询结果,搜索用时 0 毫秒
1
1.
Aim. Firefighters must meet minimum physical demands. The Norwegian Labour Inspection Authority (NLIA) has approved a standardised treadmill walking test and 3 simple strength tests for smoke divers. The results of the Trondheim test were compared with those of the NLIA tests taking into account possible effects of age, experience level and gender. Methods. Four groups of participants took part in the tests: 19 young experienced firefighters, 24 senior male firefighters and inexperienced applicants, 12 male and 8 female. Results. Oxygen uptake (VO2) at exhaustion rose linearly by the duration of the treadmill test. Time spent on the Trondheim test was closely related to performance time and peak VO2 on the treadmill test. Senior experienced firefighters did not perform better than equally fit young applicants. However, female applicants performed poorer on the Trondheim test than on the treadmill test. Performance on the Trondheim test was not closely related to muscle strength beyond a minimum. Conclusion. Firefighters completing the Trondheim test in under 19 min fit the requirements of the NLIA treadmill test. The Trondheim test can be used as an alternative to the NLIA tests for testing aerobic fitness but not for muscular strength. Women’s result of the Trondheim test were poorer than the results of the NLIA treadmill test, probably because of their lower body mass.  相似文献   
2.
We have analysed the sensitivity, specificity, and reliability of biochemical diagnosis based on microvillar membrane enzyme assay and using discriminant analysis in amniotic fluid samples obtained from 54 pregnancies at high risk for cystic fibrosis and 125 normal pregnancies. Our results show that amniotic fluid trehalase, alkaline phosphatase, alkaline phosphatase isoenzymes and gamma-glutamyltransferase enzyme activities measured during 16–20 gestational weeks, in spite of their non-specificity for cystic fibrosis, have a very good predictive value for fetal cystic fibrosis or exclude the possibility of the disease. Overall enzyme activity analysis provided over 90 per cent reliability of the method.  相似文献   
3.
In the environmental conflict that surrounds the sighting of hazardous waste facilities there is usually a volatile mix of disparities in power, expertise and information access as well as differing views on risk, which are all played out amidst commercial arrangements and environmental justice concerns. In recent times, the volatility of this mix has been further compounded by the growing climate of public concern and distrust surrounding scientific developments and technology. While there is no 'quick fix' to the complex conflict that this entails, community information systems (CISs) based on participatory models can help address the outstanding issues of capacity, information access, power inequities and environmental justice. CISs are an effective response to the five crucial elements of a toxic dispute, that is, the dialogue, capacity building, information access, evaluation of hazards and risk, and expertise. This paper will review the role of community accessible information systems in the dispute in Botany over the management and destruction of Orica Australia's stockpile of the persistent organic pollutant, hexachlorobenzene (HCB). It will focus on the role of CIS in responding to the challenges for expert information delivery, and in addressing the disparity of informational power within the toxic dispute.  相似文献   
4.
BACKGROUND, AIM AND SCOPE: Once they have been generated, polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) and other persistent organic pollutants (POPs) can persist in soils and sediments and in waste repositories for periods extending from decades to centuries. In 1994, the US EPA concluded that contaminated sites and other reservoirs are likely to become the major source of contemporary pollution problems with these substances. With this in mind, this article is the first in a new series in ESPR under the title 'Case Studies on Dioxin and POP Contaminated Sites--Contemporary and Future Relevance and Challenges', which will address this important issue. The series will document various experiences from sites contaminated with PCDD/F and other POPs. This article provides an overview of the content of the articles comprising the series. In addition, it provides a review of the subject in its own right and identifies the key issues arising from dioxin/POP-contaminated sites. Additionally, it highlights the important conclusions that can be drawn from these examples. The key aim of this article and of the series as a whole is to provide a comprehensive overview of the types of PCDD/F contaminated sites that exist as a result of historical activities. It details the various processes whereby these sites became contaminated and attempts to evaluate their contemporary relevance as sources of PCDD/Fs and other POPs. It also details the various strategies used to assess these historical legacies of contamination and the concepts developed, or which are under development, to effect their remediation. MAIN FEATURES: Special sessions on 'Contaminated sites--Cases, remediation, risk and policy' were held at the DIOXIN conferences in 2006 and 2007, and this theme will be continued at DIOXIN 2008 to be held in Birmingham. Selected cases from the approximately 70 contributions made to these sessions, together with some additional invited case studies are outlined together with the key issues they raise. By evaluating these cases and adding details of experiences published in the current literature, an overview will be given of the different features and challenges of dioxin and POP-contaminated sites. RESULTS: This article provides a systematic categorisation of types of PCDD/F and POP-contaminated sites. These are categorised according to the chemical or manufacturing process, which generated the PCDD/Fs or POPs and also includes the use and disposal aspects of the product life cycle in question. The highest historical PCDD/F and dioxin-like polychlorinated biphenyl (PCB) contamination burdens have arisen as a result of the production of chlorine and of chlorinated organic chemicals. In particular, the production of chlorinated pesticides, PCBs and the related contaminated waste streams are identified being responsible for historical releases of toxic equivalents (TEQs) at a scale of many tonnes. Along with such releases, major PCDD/F contaminated sites have been created through the application or improper disposal of contaminated pesticides, PCBs and other organochlorine chemicals, as well through the recycling of wastes and their attempted destruction. In some extreme examples, PCDD/F contaminated sites have also resulted from thermal processes such as waste incinerators, secondary metal industries or from the recycling or deposition of specific waste (e.g. electronic waste or car shredder wastes), which often contain chlorinated or brominated organic chemicals. The examples of PCDD/F and dioxin-like PCB contamination of fish in European rivers or the impact of contaminated sites upon fishing grounds and upon other food resources demonstrate the relevance of these historical problems to current and future human generations. Many of the recent food contamination problems that have emerged in Europe and elsewhere demonstrate how PCDD/F and dioxin like PCBs from historical sources can directly contaminate human and animal feedstuffs and indeed highlight their considerable contemporary relevance in this respect. Accordingly, some key experiences and lessons learnt regarding the production, use, disposal and remediation of POPs from the contaminated sites are summarised. DISCUSSION: An important criterion for evaluating the significance and risks of PCDD/Fs and other POPs at contaminated sites is their present or future potential for mobility. This, in turn, determines to a large degree their propensity for off-site transport and environmental accessibility. The detailed evaluation of contaminated site cases reveals different site-specific factors, which influence the varied pathways through which poor water-soluble POPs can be mobilised. Co-contaminants with greater water solubility are also typically present at such sites. Hence, pumping of groundwater (pump and treat) is often required in addition to attempting to physically secure a site. At an increasing number of contaminated sites, securing measures are failing after relatively short time spans compared to the time horizon, which applies to persistent organic pollutant contamination. Due to the immense costs and challenges associated with remediation of contaminated sites 'monitored natural attenuation' is increasingly gaining purchase as a conceptual remediation approach. However, these concepts may well prove limited in their practical application to contaminated sites containing persistent organic pollutants and other key pollutants like heavy metals. CONCLUSIONS: It is inevitable, therefore, that dioxin/POP-contaminated sites will remain of contemporary and future relevance. They will continue to represent an environmental issue for future generations to address. The securing and/or remediation of dioxin/POP-contaminated sites is very costly, generally in the order of tens or hundreds of millions of dollars. Secured landfills and secured production sites need to be considered as constructions not made for 'eternity' but built for a finite time scale. Accordingly, they will need to be controlled, supervised and potentially repaired/renewed. Furthermore, the leachates and groundwater impacted by these sites will require ongoing monitoring and potential further remediation. These activities result in high maintenance costs, which are accrued for decades or centuries and should, therefore, be compared to the fully sustainable option of complete remediation. The contaminated site case studies highlight that, while extensive policies and established funds for remediation exist in most of the industrialised western countries, even these relatively well-regulated and wealthy countries face significant challenges in the implementation of a remediation strategy. This highlights the fact that ultimately only the prevention of contaminated sites represents a sustainable solution for the future and that the Polluter Pays Principle needs to be applied in a comprehensive way to current problems and those which may emerge in the future. RECOMMENDATIONS AND PERSPECTIVES: With the continuing shift of industrial activities in developing and transition economies, which often have poor regulation (and weak self-regulation of industries), additional global challenges regarding POPs and other contaminated sites may be expected. In this respect, a comprehensive application of the "polluter pays principle" in these countries will also be a key to facilitate the clean-up of contaminated areas and the prevention of future contaminated sites. The threats and challenges of contaminated sites and the high costs of securing/remediating the problems highlight the need for a comprehensive approach based upon integrated pollution prevention and control. If applied to all polluting (and potentially polluting) industrial sectors around the globe, such an approach will prove to be both the cheapest and most sustainable way to underpin the development of industries in developing and transition economies.  相似文献   
5.
Purpose. To study whether perceptual identification should be included as a measure to evaluate physiological stress. Methods. Physiological variables oxygen uptake (VO2), ventilation, heart rate, blood lactate concentration, rectal temperature (Trec) and mean skin temperature, and perceptual variables rate of perceived exertion, thermal sensation and time to exhaustion, were measured at submaximal and maximal intensities during graded exercise on a treadmill to exhaustion in 12 firefighters wearing protective clothing and extra mass at 40 and 10 °C. Physiological strain index (PhSI) and perceptual strain index (PeSI) were calculated. Results. Apart from Trec, all physiological and perceptual variables were higher at submaximal intensities of 40 °C. Time to exhaustion was 16% shorter and the corresponding VO2 was reduced by 7% in the heat. A high correlation (r?=?89) between PhSI and PeSI was found at both temperatures. PeSI scores were equal to PhSI at both ambient temperatures, except at the two highest intensities in the heat, where PeSI was higher. Conclusions. These findings support use of perceptual identification to evaluate physiological stress. However, at very high intensities under hot conditions the perceptual strain was estimated higher than the physiological strain. More precise indexes are needed to include perceptual measures in safety standard.  相似文献   
6.
Landsat time series data make it possible to continuously map and examine urban land cover changes and effects on urban environments. The objectives of this study are (1) to map and analyse an impervious surface and its changes within a census district and (2) to monitor the effects of increasing impervious surface ratios on population and environment. We used satellite images from 1987, 2003 and 2011 to map the impervious surface ratio in the census district of Szeged, Hungary through normalized spectral mixture analysis. Significant increases were detected from 1987 to 2011 in industrial areas (5.7–9.1%) and inner residential areas (2.5–4.8%), whereas decreases were observed in the city centre and housing estates due to vegetation growth. Urban heat island (UHI) values were derived from the impervious surface fraction map to analyse the impact of urban land cover changes. In 2011, the average value in the industrial area was 1.76 °C, whereas that in the inner residential area was 1.35–1.69 °C. In the city centre zones and housing estates, values ranging from 1.4 to 1.5 °C and from 1.29 to 1.5 °C, respectively, were observed. Our study reveals that long-term land cover changes can be derived at the district level from Landsat images and that their effects can be identified and analysed, providing important information for city planners and policy makers.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号