首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   90篇
  免费   2篇
  国内免费   1篇
安全科学   3篇
废物处理   7篇
环保管理   8篇
综合类   13篇
基础理论   11篇
污染及防治   33篇
评价与监测   11篇
社会与环境   5篇
灾害及防治   2篇
  2023年   3篇
  2022年   2篇
  2021年   12篇
  2020年   2篇
  2019年   5篇
  2018年   5篇
  2017年   4篇
  2016年   6篇
  2015年   2篇
  2014年   6篇
  2013年   4篇
  2012年   5篇
  2011年   4篇
  2010年   5篇
  2009年   1篇
  2008年   5篇
  2007年   9篇
  2006年   4篇
  2005年   2篇
  2004年   3篇
  2003年   2篇
  1996年   1篇
  1974年   1篇
排序方式: 共有93条查询结果,搜索用时 82 毫秒
1.
Rainfall interception represents the amount of water trapped in natural cover that is not drained directly to the ground. Intercepted rainfall may evaporate after a rain event, making it one of the main drivers of water balance and hydrologic regionalization. This process can be affected by factors such as climate, altitude, vegetation type, and topography. Here is a simple method of calculating rainfall interception in temperate forests using in Santa Maria Yavesia, Oaxaca, and Mexico as an illustrative study area. We used two rain gauges to measure net precipitation (Np) under the canopy at each study site and one gauge outside the canopy to obtain gross precipitation (Gp). Throughfall (Th) was indirectly measured using hemispherical photographs. Rainfall interception was obtained through a combination Th and Gp and Np. The mean rainfall interception was 50.6% in the Abies forests, 23%–40% in the coniferous‐mixed forests, and 27.4% in the broad‐leaved forests. We classified rainfall events by intensity to determine the effect of canopy structure and precipitation and found that 75% of the events were weak events, 24% were moderate events, and 1% were strong events. In addition, we found that rainfall interception was lower when the intensity of precipitation was higher. Our method can be replicated in different ecosystems worldwide as a tool for assessing the influence of rainfall interception in terms of ecological services.  相似文献   
2.
City bus drivers spend hours driving under time pressure, in congested traffic and in a monotonous sitting position. This leads to unhealthy working conditions, especially in terms of physical and psychological stress. The aim of this study is to investigate whether an active steering system can alleviate the musculoskeletal stress involved in manoeuvring a bus. Twenty bus drivers drove a city bus equipped with the Volvo dynamic steering (VDS) support system in real traffic. Steering effort was evaluated with electromyography and with a questionnaire. Compared to baseline, VDS significantly reduced the required muscle activity by on average 15–25% while turning, and up to 68% in the part of the manoeuvre requiring maximum effort. The bus drivers believed that VDS will help reduce neck and shoulder problems, and they expressed a desire to have VDS installed in their own bus.  相似文献   
3.
Corals and coral-associated species are highly vulnerable to the emerging effects of global climate change. The widespread degradation of coral reefs, which will be accelerated by climate change, jeopardizes the goods and services that tropical nations derive from reef ecosystems. However, climate change impacts to reef social–ecological systems can also be bi-directional. For example, some climate impacts, such as storms and sea level rise, can directly impact societies, with repercussions for how they interact with the environment. This study identifies the multiple impact pathways within coral reef social–ecological systems arising from four key climatic drivers: increased sea surface temperature, severe tropical storms, sea level rise and ocean acidification. We develop a novel framework for investigating climate change impacts in social–ecological systems, which helps to highlight the diverse impacts that must be considered in order to develop a more complete understanding of the impacts of climate change, as well as developing appropriate management actions to mitigate climate change impacts on coral reef and people.  相似文献   
4.
Differential white blood cell counting was performed on blood from the fish species Oreochromis niloticus and was used as an in situ indicator of the species’ exposure to contamination. Ten young fish were collected in an area influenced by the discharge of effluents and from a fish farm (control group). The fish were anesthetized and caudal puncture was used to collect the blood. Differential white blood cell counting was performed, as well as the counting of total leukocytes and thrombocytes (in 2000 cells). Physicochemical parameters of the water from both sites were analyzed. The water from the polluted area was found to have high conductivity and low levels of dissolved oxygen, factors that indicate poor environmental quality. Fish collected from the polluted site presented higher percentages of eosinophils and monocytes and fewer thrombocytes because of exposure to pollution and hypoxic conditions. The differential white blood cell count represents a suitable biomarker of environmental health and provides a tool for biomonitoring water quality.  相似文献   
5.
Quantitative assessments have long been used to evaluate the condition of the natural environment, providing information for standard setting, adaptive management, and monitoring. Similar approaches have been developed to measure environmental governance, however, the end result (e.g., numeric indicators) belies the subjective and normative judgments that are involved in evaluating governance. We demonstrate a framework that makes this information transparent, through an application of the Freshwater Health Index in three different river basins in Latin America. Water Governance is measured on a 0–100 scale, using data derived from perception-based surveys administered to stakeholders. Results suggest that water governance is a primary area of concern in all three places, with low overall scores (Guandu-26, Alto Mayo-38, Bogotá-43). We conclude that this approach to measuring governance at the river basin scale provides valuable information to support monitoring and decision making, and we offer suggestions on how it can be improved.Electronic supplementary materialThe online version of this article (10.1007/s13280-020-01407-8) contains supplementary material, which is available to authorized users.  相似文献   
6.
The aim of the present study was to comparatively evaluate genomic damage (micronucleus) and cellular death (pyknosis, karyolysis, and karyorrhexis) in exfoliated oral mucosa cells from crack cocaine users by micronucleus test. A total of 30 crack cocaine users and 30 health controls (non-exposed individuals) were included in this setting. Individuals had epithelial cells from cheek mechanically exfoliated, placed in fixative, and dropped in clean slides, which were checked for the above nuclear phenotypes. The results pointed out significant statistical differences (p?<?0.05) of micronucleated oral mucosa cells from crack cocaine users. Exposure to crack cocaine caused an increase of other nuclear alterations closely related to cytotoxicity such as karyolysis in oral cells as well. In summary, these data indicate that crack cocaine is able to induce chromosomal breakage and cellular death in oral mucosa cells of users.  相似文献   
7.
C7-C11 perfluorinated carboxylates (PFACs) and perfluorooctansulfonate (PFOS) were analysed in selected stretches of the River Po and its major tributaries. Analyses were performed by solid-phase extraction (SPE) with Oasis HLB cartridges and methanol elution followed by LC-MS-MS detection using 13C-labelled internal standards. High concentration levels ( approximately 1.3 microg l(-1)) of perfluorooctanoate (PFOA) were detected in the Tánaro River close to the city Alessandria. After this tributary, levels between 60 and 337 ng l(-1) were measured in the Po River on several occasions. The PFOA concentration close to the river mouth in Ferrara was between 60 and 174 ng l(-1). Using the river discharge flow data in m3 s(-1) at this point (average approximately 920 m3 s(-1) for the year 2006), a mass load of approximately 0.3 kg PFOA per hour or approximately 2.6 tons per year discharged in the Adriatic Sea has been calculated. PFOS concentration levels in the Po River at Ferrara were approximately 10 ng l(-1).  相似文献   
8.
Every year, the number of discarded electro-electronic products is increasing. For this reason recycling is needed, to avoid wasting non-renewable natural resources. The objective of this work is to study the recycling of materials from parallel wire cable through unit operations of mineral processing. Parallel wire cables are basically composed of polymer and copper. The following unit operations were tested: grinding, size classification, dense medium separation, electrostatic separation, scrubbing, panning, and elutriation. It was observed that the operations used obtained copper and PVC concentrates with a low degree of cross contamination. It was concluded that total liberation of the materials was accomplished after grinding to less than 3 mm, using a cage mill. Separation using panning and elutriation presented the best results in terms of recovery and cross contamination.  相似文献   
9.
10.
In the Recôncavo of Bahia (located between 12°33′ and 13°10′S and 38°00′and 39°00′W), there are significant discharges of SO2 and NOx due to local, industrial and urban activities. The incoming air masses from the Atlantic Ocean are enriched with seaspray, which neutralizes part of the rain acidity. The extent of seaspray neutralization of rain acidity was quantified in four sites of the region, each with different loads of seaspray. Rain samples were obtained daily at the same time, integrating the precipitation of the previous 24 h, using wet-only collectors and analyzed for pH by potentiometry and for sodium by flame photometry. The amount of rain acidity in Recôncavo neutralized by seaspray ranged from <1% up to 88% and depended on the site. On average, neutralization ranged from 5% to 18%.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号