首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   12篇
  免费   0篇
  国内免费   1篇
环保管理   1篇
综合类   1篇
基础理论   5篇
污染及防治   6篇
  2022年   1篇
  2018年   1篇
  2017年   1篇
  2015年   2篇
  2014年   1篇
  2013年   2篇
  2008年   1篇
  2007年   1篇
  2006年   1篇
  2005年   2篇
排序方式: 共有13条查询结果,搜索用时 328 毫秒
1.
Toxic metals removal from wastewater sewage sludge can be achieved through microbial processes involving Acidithiobacillus ferrooxidans. The oxidation of ferrous ions by A. ferrooxidans, cultured in sewage sludge filtrate, was studied in both batch and continuous flow stirred tank reactors. Sewage sludge filtrate containing natural nutrients (phosphorus and nitrogen) was recovered as effluent following the dehydration of a primary and secondary sludge mixture. Batch and continuous flow stirred tank reactor tests demonstrated that A. ferrooxidans were able to grow and completely oxidize ferrous iron in a culture medium containing more than 80% (v v(-1)) sewage sludge filtrate with 10 g Fe(II) L(-1) added. Toxic levels were reached when total organic carbon in the sewage sludge filtrate exceeded 250 mg L(-1). The ferric iron solution produced in the sludge filtrate by A. ferrooxidans was used to solubilize heavy metals in primary and secondary sludge. The solubilization of Cu, Cr, and Zn yielded 71, 49, and 80%, respectively. This is comparable with the yield percentages obtained using a FeCl(3) solution. The cost of treating wastewater sewage sludge by bioproducing a ferric ion solution from sewage sludge is three times less expensive than the conventional method requiring a commercial ferric chloride solution.  相似文献   
2.
Polycyclic aromatic hydrocarbons (PAHs) have been widely studied due to their presence in all the environmental media and toxicity to life. These molecules are strongly adsorbed on the particulate matters of soils, sludges or sediments because of their strong hydrophobicity which makes them less bioavailability, thus limiting their bioremediation. Different sludge treatment processes were tested to evaluate their performances for PAH removal from sludge prealably doped with 11 PAHs (5.5mg each PAH kg(-1) of dry matter (DM)): two biological processes (mesophilic aerobic digestion (MAD) and simultaneous sewage sludge digestion and metal leaching (METIX-BS)) were tested to evaluate PAH biodegradation in sewage sludge. In parallel, two chemical processes (quite similar Fenton processes: chemical metal leaching (METIX-AC) and chemical stabilization (STABIOX)) and one electrochemical process (electrochemical stabilization (ELECSTAB)) were tested to measure PAH removal by these oxidative processes. Moreover, PAH solubilisation from sludge by addition of a nonionic surfactant Tween 80 (Tw80) was also tested. The best yields of PAH removal were obtained by MAD and METIX-BS with more than 95% 3-ring PAH removal after a 21-day treatment period. Tw80 addition during MAD treatment increased 4-ring PAHs removal rate. In addition, more than 45% of 3-ring PAHs were removed from sludge by METIX-AC and during ELECSTAB process were quiet good with approximately 62% of 3-ring PAHs removal. However, little weaker removal of 3-ring PAHs (<35%) by STABIOX. None of the tested processes were efficient for the elimination of high molecular weight (> or = 5-ring) PAHs from sludge.  相似文献   
3.
Bioleaching processes have been demonstrated to be effective technologies in removing heavy metals from wastewater sludge, but long hydraulic retention times are typically required to operate these bioprocesses. A hybrid process (coupling biological and chemical processes) has been explored in laboratory pilot-scale experiments for heavy metals (cadmium [Cd], copper [Cu], chromium [Cr], and zinc [Zn]) removal from three types of sludge (primary sludge, secondary activated sludge, and a mixture of primary and secondary sludge). The hybrid process consisted of producing a concentrate ferric ion solution followed by chemical treatment of sludges. Ferric iron solution was produced biologically via oxidation of ferrous iron by A. ferrooxidans in a continuous-flow stirred tank (5.2 L) reactor (CSTR). Wastewater sludge filtrate (WSF) containing nutrients (phosphorus and nitrogen) has been used as culture media to support the growth and activity of indigenous iron-oxidizing bacteria. Results showed that total organic carbon (TOC) concentrations of the culture media in excess of 235 mg/L were found to be inhibitory to bacterial growth. The oxidation rate increased as ferrous iron concentrations ranged from 10 to 40 g Fe2+/L. The percentage of ferrous iron (Fe2+) oxidized to ferric iron (Fe3+) increased as the hydraulic retention time (HRT) increased from 12 to 48 h. Successful and complete Fe2+ oxidation was recorded at a HRT of 48 h using 10 g Fe2+/L. Subsequently, ferric ion solution produced by A. ferrooxidans in sludge filtrate was used to solubilize heavy metals contained in wastewater sludge. The best solubilization was obtained with a mixture of primary and secondary sludge, demonstrating a removal efficiency of 63, 71, 49, and 80% for Cd, Cu, Cr, and Zn, respectively.  相似文献   
4.
The objective of this research was to investigate the performance of the ferrous sulfate bioleaching (FSBL) process in a pilot plant for decontamination and stabilization of wastewater sludge. Batch and continuous experiments, conducted with two 4-m3 bioreactors using indigenous iron-oxidizing bacteria (20% v/v of inoculum) with addition of 4.0 g ferrous sulfate heptahydrate per liter of sludge initially acidified to pH 4.0, were sufficient for effective heavy metal (cadmium, copper, manganese, zinc, and lead) removal yields. The average metal removal yields during the FSBL process were as follows: cadmium (69 to 75%), copper (68 to 70%), manganese (72 to 73%), zinc (65 to 66%), and lead (16%). The FSBL process was also found to be effective in removing both fecal and total coliforms (abatement > 5 to 6 log units). The nutrients content (nitrogen, phosphorus, and magnesium) were also preserved in decontaminated sludge.  相似文献   
5.
Tetracycline antibiotics in the environment: a review   总被引:4,自引:0,他引:4  
Tetracycline antibiotics are one of the primarily antibiotics groups used for veterinary purposes, for human therapy and for agricultural purposes. Amongst the different antibiotics used, more attention is paid to tetracycline’s as it exhibits serious environmental problems including ecological risks and human health damages. Due to their extensive usage, most of the actual evidence suggests that tetracycline antibiotics are omnipresent compounds found in different ecological compartments. After medication, more than 70 % of tetracycline antibiotics are excreted and released in active form into the environment via urine and feces from humans and animals. Their highly hydrophilic character and low volatility have resulted in significant persistence in the aquatic environment. Very few studies describe the fate and toxicity of tetracycline antibiotics in the environment. Here, we review several important issues with regard to: (1) the toxicity of these compounds on aquatic and terrestrial organisms; (2) their estrogenic effects; (3) their behavior in different ecological systems and; (4) the by-products generated during water treatment. These antibiotics residues promote the development of antibiotic resistant microorganisms, which can induce adverse effect to human health by increasing the risk of certain infections. Based on recent research results, the occurrence of tetracycline antibiotics in the environment inhibits the growth of some terrestrial and aquatic species. Besides, the residual concentrations of such drugs could affect steroidogenic pathway and consequently may cause endocrine disruption of aquatic species. Most of the wastewater treatment plants are not capable of removing effectively the tetracycline antibiotics. Therefore, there is a need to develop alternative processes to remove them from waters. Advanced oxidation processes have been proposed as alternative methods to ensure higher degradation and mineralization of tetracycline antibiotics are present in waters.  相似文献   
6.
Swimming pool users are a source of various contaminants and microorganisms. Conventional chlorine-based reagents treatment is commonly used to disinfect water. However, this disinfection treatment has serious serious health issues such as formation of carcinogenic by-products, i.e., trihalomethanes. In order to prevent this problem, an electrochemical disinfection process was carried out using synthetic and real swimming pool waters. The performance of the electrochemical system was evaluated by studying the effect of current intensity (0.5–3.0 A), treatment time, type of anode (Nb/BDD and Ti/Pt) and the initial concentration of pathogens Escherichia coli and P. aeruginosa. Results show that real swimming pool water, initially containing 106 CFU/100 mL of pathogens, was disinfected at current intensities of 1.5 and 3.0 A using, respectively, Nb/BDD and Ti/Pt as anode materials (CFU: colony-forming units, BDD: boron-doped diamond). This work is also one of the few showing the up-scaling of electrochemical disinfection of real swimming pool water at large volumes of 100 L.  相似文献   
7.
Highly hydrophobic Di 2-ethyl hexyl phthalate (DEHP) is one of the most prevalent plasticizers in wastewaters. Since its half-life in biological treatment is around 25 days, it can be used as an efficiency indicator of wastewater treatment plant for the removal of hydrophobic emerging contaminants. In this study, the performance of submerged membrane bioreactor was monitored to understand the effect of DEHP on the growth of aerobic microorganisms. The data showed that the chemical oxygen demand (COD) and ammonia concentration were detected below 10 and 1.0 mg/L, respectively for operating conditions of hydraulic retention time (HRT) = 4 and 6 hr, sludge retention time (SRT) = 140 day and sludge concentration between 11.5 and 15.8 g volatile solid (VS)/L. The removal efficiency of DEHP under these conditions was higher and ranged between 91% and 98%. Results also showed that the removal efficiency of DEHP in biological treatment depended on the concentration of sludge, as adsorption is the main mechanism of its removal. For the submerged membrane bioreactor, the pore size is the pivotal factor for DEHP removal, since it determines the amount of soluble microbial products coming out of the process. Highly assimilated microorganisms increase the biodegradation rate, as 74% of inlet DEHP was biodegraded; however, the concentration of DEHP inside sludge was beyond the discharge limit. Understanding the fate of DEHP in membrane bioreactor, which is one of the most promising and futuristic treatment process could provide replacement for conventional processes to satisfy the future stricter regulations on emerging contaminants.  相似文献   
8.
Biological treatment of landfill leachate is challenging due to the presence of complex compounds. Here, we treated an old landfill leachate using a membrane bioreactor under the following conditions: 24 h for hydraulic retention, 65 days of sludge retention and an average organic load rate of 1.71 ± 0.16 g/L/day. We observed a high removal of ammonia, phosphorous and some metals. However, removal of organic carbon was incomplete. Despite a major removal of suspended solids, hydrophobic and volatile hydrophilic compounds, high concentration of fulvic acid and hydrophilic contaminants was found in the effluent. Overally, we demonstrate that the presence of humic substances in the effluent is associated with the detection of arsenic, copper and chromium and di(2-ethylhexyl) phthalate.  相似文献   
9.
10.
The performance of the electrochemical oxidation process for efficient treatment of domestic wastewater loaded with organic matter was studied. The process was firstly evaluated in terms of its capability of producing an oxidant agent (H2O2) using amorphous carbon (or carbon felt) as cathode, whereas Ti/BDD electrode was used as anode. Relatively high concentrations of H2O2 (0.064 mM) was produced after 90 min of electrolysis time, at 4.0 A of current intensity and using amorphous carbon at the cathode. Factorial design and central composite design methodologies were successively used to define the optimal operating conditions to reach maximum removal of chemical oxygen demand (COD) and color. Current intensity and electrolysis time were found to influence the removal of COD and color. The contribution of current intensity on the removal of COD and color was around 59.1 and 58.8 %, respectively, whereas the contribution of treatment time on the removal of COD and color was around 23.2 and 22.9 %, respectively. The electrochemical treatment applied under 3.0 A of current intensity, during 120 min of electrolysis time and using Ti/BDD as anode, was found to be the optimal operating condition in terms of cost/effectiveness. Under these optimal conditions, the average removal rates of COD and color were 78.9?±?2 and 85.5?±?2 %, whereas 70 % of total organic carbon removal was achieved.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号