首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   8篇
  免费   0篇
安全科学   1篇
综合类   2篇
污染及防治   4篇
社会与环境   1篇
  2021年   1篇
  2020年   2篇
  2019年   1篇
  2013年   2篇
  2005年   2篇
排序方式: 共有8条查询结果,搜索用时 31 毫秒
1
1.
Environmental Science and Pollution Research - A composite polymer, hydroxyapatite/poly(acrylamide-acrylic acid), was synthesized by gamma-induced polymerization. The factors affecting the sorption...  相似文献   
2.
PM2.5 (particulate matter with an aerodynamic diameter <2.5 μm) samples were collected in the indoor environments of 15 urban homes and their adjacent outdoor environments in Alexandria, Egypt, during the spring time. Indoor and outdoor carbon dioxide (CO2) levels were also measured concurrently. The results showed that indoor and outdoor PM2.5 concentrations in the 15 sites, with daily averages of 45.5 ± 11.1 and 47.3 ± 12.9 µg/m3, respectively, were significantly higher than the ambient 24-hr PM2.5 standard of 35 µg/m3 recommended by the U.S. Environmental Protection Agency (EPA). The indoor PM2.5 and CO2 levels were correlated with the corresponding outdoor levels, demonstrating that outdoor convection and infiltration could lead to direct transportation indoors. Ventilation rates were also measured in the selected residences and ranged from 1.6 to 4.5 hr?1 with median value of 3.3 hr?1. The indoor/outdoor (I/O) ratios of the monitored homes varied from 0.73 to 1.65 with average value of 0.99 ± 0.26 for PM2.5, whereas those for CO2 ranged from 1.13 to 1.66 with average value of 1.41 ± 0.15. Indoor sources and personal activities, including smoking and cooking, were found to significantly influence indoor levels.

Implications: Few studies on indoor air quality were carried out in Egypt, and the scarce data resulted from such studies do not allow accurate assessment of the current situation to take necessary preventive actions. The current research investigates indoor levels of PM2.5 and CO2 in a number of homes located in the city of Alexandria as well as the potential contribution from both indoor and outdoor sources. The study draws attention of policymakers to the importance of the establishment of national indoor air quality standards to protect human health and control air pollution in different indoor environments.  相似文献   
3.
4.
Indoor particulate matter samples were collected in 17 homes in an urban area in Alexandria during the summer season. During air measurement in all selected homes, parallel outdoor air samples were taken in the balconies of the domestic residences. It was found that the mean indoor PM2.5 and PM10 (particulate matter with an aerodynamic diameter ≤2.5 and ≤10 μm, respectively) concentrations were 53.5 ± 15.2 and 77.2 ± 15.1 µg/m3, respectively. The corresponding mean outdoor levels were 66.2 ± 16.5 and 123.8 ± 32.1 µg/m3, respectively. PM2.5 concentrations accounted, on average, for 68.8 ± 12.8% of the total PM10 concentrations indoors, whereas PM2.5 contributed to 53.7 ± 4.9% of the total outdoor PM10 concentrations. The median indoor/outdoor mass concentration (I/O) ratios were 0.81 (range: 0.43–1.45) and 0.65 (range: 0.4–1.07) for PM2.5 and PM10, respectively. Only four homes were found with I/O ratios above 1, indicating significant contribution from indoor sources. Poor correlation was seen between the indoor PM10 and PM2.5 levels and the corresponding outdoor concentrations. PM10 levels were significantly correlated with PM2.5 loadings indoors and outdoors and this might be related to PM10 and PM2.5 originating from similar particulate matter emission sources. Smoking, cooking using gas stoves, and cleaning were the major indoor sources contributed to elevated indoor levels of PM10 and PM2.5.

Implications: The current study presents results of the first PM2.5 and PM10 study in homes located in the city of Alexandria, Egypt. Scarce data are available on indoor air quality in Egypt. Poor correlation was seen between the indoor and outdoor particulate matter concentrations. Indoor sources such as smoking, cooking, and cleaning were found to be the major contributors to elevated indoor levels of PM10 and PM2.5.  相似文献   
5.
ABSTRACT

The present study investigated indoor and outdoor concentrations of two particulate matter size fractions (PM10 and PM2.5) and CO2 in 20 urban homes ventilated naturally and located in one congested residential and commercial area in the city of Alexandria, Egypt. The results indicate that the daily mean PM2.5 concentrations measured in the ambient air, living rooms, and kitchens of all sampling sites exceeded the WHO guideline by 100%, 65%, and 95%, respectively. The daily mean outdoor and indoor PM10 levels in all sampling sites were found to exceed the WHO guideline by 100% and 80%, respectively. The indoor PM10 and PM2.5 concentrations were significantly correlated with their corresponding outdoor levels, as natural ventilation through opening doors and windows allowed direct transfer of outdoor airborne particles into the indoor air. Most of the kitchens investigated had higher indoor concentrations of PM2.5 and CO2 than in living rooms. The elevated levels of PM2.5 and CO2 in domestic kitchens were probably related to inadequate ventilation. The current study attempted to understand the sources and the various indoor and outdoor factors that affect indoor PM10, PM2.5 and CO2 concentrations. Several domestic activities, such as smoking, cooking, and cleaning, were found to constitute important sources of indoor air pollution. The indoor pollution caused by PM2.5 was also found to be more serious in the domestic kitchens than in the living rooms and the results suggest that exposure to PM2.5 is high and highlights the need for more effective control measures.

Implications: Indoor air pollution is a complex problem that involves many determinant factors. Understanding the relationships and the influence of various indoor and outdoor factors on indoor air quality is very important to prioritize control measures and mitigation action plans. There is currently a lack of research studies in Egypt to investigate determinant factors controlling indoor air quality for urban homes. The present study characterizes the indoor and outdoor concentrations of PM10, PM2.5, and CO2 in residential buildings in Alexandria city. The study also determines the indoor and outdoor factors which influence the indoor PM and CO2 concentrations as well as it evaluates the potential indoor sources in the selected homes. This research will help in the development of future indoor air quality standards for Egypt.  相似文献   
6.
7.
Identification of novel effective mosquitocidal compounds is essential to combat increasing resistance rates, concern for the environment and food safety, the unacceptability of many organophosphates and organochlorines and the high cost of synthetic pyrethroids. An increasing number of researchers are reconsidering botanicals containing active phytochemicals in their efforts to address some of these problems. To be highly competitive and effective, the ideal phytochemical should possess a combination of toxic effects and residual capacity. Acute toxicity is required at doses comparable to some commercial synthetic insecticides while chronic or sub-chronic toxicity is required to produce growth inhibition, developmental toxicity and generational effects. In this article, we review the current state of knowledge on larvicidal plant species, extraction processes, growth and reproduction inhibiting phytochemicals, botanical ovicides, synergistic, additive and antagonistic joint action effects of mixtures, residual capacity, effects on non-target organisms, resistance, screening methodologies, and discuss promising advances made in phytochemical research.  相似文献   
8.
OBJECTIVE: The main purpose of this study is to estimate and quantify the contribution of the infrastructure to highway crashes and to develop an infrastructure coefficient, that represents the overall characteristics of the highway and could be used as an independent variable in a crash-prediction model. METHODS: The infrastructure is defined in this study as the highway and its geometric features, including alignment, road-side elements, sight-distances, presence of guardrails, access-points, roadway consistency, and additional variables that measure the overall quality of the highway alignment and elements. The analysis and developments are conducted for two-lane rural highways. The approach taken is to identify the high crash-rate roads, those with crash rates above 0.25 crashes per million vehicle-km, by Smallest Space Analysis. This type of analysis allows the aggregation of higher crash-rate roads versus lower-crash-rate roads only by their infrastructure coefficients, without consideration of their crash records. RESULTS: Crash rates that are attached by Smallest Space Analysis to the group of roads that had less desirable infrastructure features show a high correlation between the same roads and high crash rates vs. identified better infrastructures and low crash rates. Further analysis shows that low crash-rate infrastructure, as defined in this study for two-lane rural highways, can reduce the crash rate by 44% versus high crash-rate infrastructure, at the 99% confidence level, which is almost a certainty. A model for the prediction of crash rates based on a proposed infrastructure coefficient is calibrated and presented. CONCLUSIONS: It is suggested that this model be used in evaluating alternatives for new highways or in improving the alignment and road features of existing highways.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号