首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   27篇
  免费   0篇
废物处理   3篇
环保管理   3篇
综合类   4篇
基础理论   1篇
污染及防治   16篇
  2018年   1篇
  2017年   1篇
  2013年   2篇
  2012年   2篇
  2008年   3篇
  2006年   4篇
  2005年   1篇
  2003年   1篇
  1998年   1篇
  1989年   1篇
  1984年   4篇
  1982年   1篇
  1981年   2篇
  1965年   2篇
  1963年   1篇
排序方式: 共有27条查询结果,搜索用时 46 毫秒
1.
Odor and gas release from anaerobic lagoons for treating swine waste affect air quality in neighboring communities but rates of release are not well documented. A buoyant convective flux chamber (BCFC) was used to determine the effect of lagoon loading rate on measured odor and gas releases from two primary lagoons at a simulated wind speed of 1.0 m s(-1). Concentrations of ammonia (NH3), hydrogen sulfide (H2S), carbon dioxide (CO2), sulfur dioxide (SO2), and nitric oxide (NO) in 50-L air samples were measured. A panel of human subjects, whose sensitivity was verified with a certified reference odorant, evaluated odor concentration, intensity, and hedonic tone. Geometric mean odor concentrations of BCFC inlet and outlet samples and of downwind berm samples were 168 +/- 44 (mean +/- 95% confidence interval), 262 +/- 60, and 114 +/- 38 OU(E) m(-3) (OU(E), European odor unit, equivalent to 123 microg n-butanol), respectively. The overall geometric mean odor release was 2.3 +/- 1.5 OU(E) s(-1) m(-2) (1.5 +/- 0.9 OU s(-1) m(-2)). The live mass specific geometric mean odor release was 13.5 OU(E) s(-1) AU(-1) (animal unit = 500 kg live body mass). Overall mean NH3, H2S, CO2 and SO2 releases were 101 +/- 24, 5.7 +/- 2.0, 852 +/- 307, and 0.5 +/- 0.4 microg s(-1) m(-2), respectively. Nitric oxide was not detected. Odor concentrations were directly proportional to H2S and CO2 concentrations and odor intensity, and inversely proportional to hedonic tone and SO2 concentration (P < 0.05). Releases of NH3, H2S, and CO2 were directly proportional (P < 0.05) to volatile solids loading rate (VSLR).  相似文献   
2.
N Adams  AJ Dobbs 《Chemosphere》1984,13(8):965-971
Two different test methods for assessing the toxicity of aminotriazole to Selenastrum capricornutum are compared. Growth medium composition is demonstrated to have a significant effect on the toxicity of aminotriazole.  相似文献   
3.
Comprehensive field studies were initiated in 2002 to measure emissions of ammonia (NH3), hydrogen sulfide (H2S), carbon dioxide (CO2), methane (CH4), nonmethane hydrocarbons (NMHC), particulate matter <10 microm in diameter, and total suspended particulate from swine and poultry production buildings in the United States. This paper focuses on the quasicontinuous gas concentration measurement at multiple locations among paired barns in seven states. Documented principles, used in air pollution monitoring at industrial sources, were applied in developing quality assurance (QA) project plans for these studies. Air was sampled from multiple locations with each gas analyzed with one high quality commercial gas analyzer that was located in an environmentally controlled on-farm instrument shelter. A nominal 4 L/min gas sampling system was designed and constructed with Teflon wetted surfaces, bypass pumping, and sample line flow and pressure sensors. Three-way solenoids were used to automatically switch between multiple gas sampling lines with > or =10 min sampling intervals. Inside and outside gas sampling probes were between 10 and 115 m away from the analyzers. Analyzers used chemiluminescence, fluorescence, photoacoustic infrared, and photoionization detectors for NH3, H2S, CO2, CH4, and NMHC, respectively. Data were collected using personal computer-based data acquisition hardware and software. This paper discusses the methodology of gas concentration measurements and the unique challenges that livestock barns pose for achieving desired accuracy and precision, data representativeness, comparability and completeness, and instrument calibration and maintenance.  相似文献   
4.
5.
In response to recent changes in National Pollutant Discharge Elimination System (NPDES) permit regulations, rapid (7-day) static renewal toxicity tests have been developed to detect chronic (sublethal and lethal) effect concentrations of municipal and industrial effluents on freshwater and marine/estuarine organisms. This paper evaluates results from short-term (7-day) chronic effluent tests measuring effects on the growth and survival of the larvae of estuarine sheepshead minnow (Cyprinodon variegatus). Growth was the more sensitive endpoint in 52% of the effluent tests; survival was most sensitive in 7% of the tests. Growth and survival were equally sensitive endpoints in 26% of the tests, while there was no effect on either endpoint at the highest test concentration in 15% of the tests. Four short-term chronic tests were conducted concurrently with early life stage (ELS) tests using a common effluent. Effect concentrations were generally (two of three) within one dilution (a factor of three). Comparison of short-term chronic and ELS tests were also conducted with reference single chemicals and the results were slightly better than the effluent comparisons. A series of ten intralaboratory tests and seven interlaboratory tests were conducted to assess the variability among tests results. Toxicity in these tests varied by no more than one test concentration interval. We concluded that this sheepshead minnow test is suitable to estimate chronic values for complex effluents discharged to marine/estuarine environments within the NPDES permit regulations.  相似文献   
6.
The tapered element oscillating microbalance (TEOM) is one type of continuous ambient particulate matter (PM) monitor. Adsorption and desorption of moisture and semivolatile species may cause positive or negative artifacts in TEOM PM mass measurement. The objective of this field study was to investigate possible uncertainties associated with TEOM measurements in the poultry operation environment. For comparisons of TEOM with filter-based gravimetric method, four instruments (TEOM-PM10, low-volume PM10 sampler TEOM-PM2.5, and PM2.5 speciation sampler) were collocated and tested inside a poultry house for PM2.5 and PM10 (PM with aerodynamic equivalent diameter < or =2.5 and < or =10 microm, respectively) measurements. Fifteen sets of 24-hr PM10 concentrations and 13 sets of 24-hr PM2.5 measurements were obtained. Results indicate that compared with filter-based gravimetric method, TEOM gave significantly lower values of both PM10 and PM2.5 mass concentrations. For PM10, the average ratio of TEOM to the gravimetric method was 0.936. For PM2.5, the average ratio of TEOM to the gravimetric method was 0.738. Particulate matter in the poultry houses possibly contains semivolatile compounds and moisture due to high levels of relative humidity (RH) and gas pollutants. The internal heating mechanism of the TEOM may cause losses in mass through volatilization. To investigate the effects of TEOM settings on concentration measurements, the heaters of two identical TEOMs were set at 50 degrees C, 30 degrees C, or no heating at all. They were collocated and tested for total suspended particle (TSP), PM10, and PM25 measurements in layer house for 6 weeks. For all TSR PM10, and PM2.5 measurements, the internal TEOM temperature setting had a significant effect (P < 0.05). Significantly higher PM mass concentrations were measured at lower temperature settings. The effects of environmental (i.e., temperature, RH, NH3 and CO2 concentrations) and instrumental (i.e., filter loading and noise) parameters on PM measurements were also assessed using regression analysis.  相似文献   
7.
8.
Methane and carbon dioxide emission from two pig finishing barns   总被引:3,自引:0,他引:3  
Agricultural activities are an important source of greenhouse gases. However, comprehensive, long-term, and high-quality measurement data of these gases are lacking. This article presents a field study of CH(4) and CO(2) emission from two 1100-head mechanically ventilated pig (Sus scrofa) finishing barns (B1 and B2) with shallow manure flushing systems and propane space heaters from August 2002 to July 2003 in northern Missouri. Barn 2 was treated with soybean oil sprinkling, misting essential oils, and misting essential oils with water to reduce air pollutant emissions. Only days with CDFB (complete-data-full-barn), defined as >80% of valid data during a day with >80% pigs in the barns, were used. The CH(4) average daily mean (ADM) emission rates were 36.2 +/- 2.0 g/d AU (ADM +/- 95% confidence interval; animal unit = 500 kg live mass) from B1 (CDFB days = 134) and 28.8 +/- 1.8 g/d AU from B2 (CDFB days = 131). The CO(2) ADM emission rates were 17.5 +/- 0.8 kg/d AU from B1 (CDFB days = 146) and 14.2 +/- 0.6 kg/d AU from B2 (CDFB days = 137). The treated barn reduced CH(4) emission by 20% (P < 0.01) and CO(2) emission by 19% (P < 0.01). The CH(4) and CO(2) released from the flushing lagoon effluent were equivalent to 9.8 and 4.1% of the CDFB CH(4) and CO(2) emissions, respectively. The emission data were compared with the literature, and the characteristics of CH(4) and CO(2) concentrations and emissions were discussed.  相似文献   
9.
Abstract

Comprehensive field studies were initiated in 2002 to measure emissions of ammonia (NH3), hydrogen sulfide (H2S), carbon dioxide (CO2), methane (CH4), nonmethane hydrocarbons (NMHC), particulate matter <10 µm in diameter, and total suspended particulate from swine and poultry production buildings in the United States.

This paper focuses on the quasicontinuous gas concentration measurement at multiple locations among paired barns in seven states. Documented principles, used in air pollution monitoring at industrial sources, were applied in developing quality assurance (QA) project plans for these studies. Air was sampled from multiple locations with each gas analyzed with one high quality commercial gas analyzer that was located in an environmentally controlled on-farm instrument shelter. A nominal 4 L/min gas sampling system was designed and constructed with Teflon wetted surfaces, bypass pumping, and sample line flow and pressure sensors. Three-way solenoids were used to automatically switch between multiple gas sampling lines with ≥10 min sampling intervals. Inside and outside gas sampling probes were between 10 and 115 m away from the analyzers. Analyzers used chemiluminescence, fluorescence, photoacoustic infrared, and photoionization detectors for NH3, H2S, CO2, CH4, and NMHC, respectively. Data were collected using personal computer-based data acquisition hardware and software. This paper discusses the methodology of gas concentration measurements and the unique challenges that livestock barns pose for achieving desired accuracy and precision, data representativeness, comparability and completeness, and instrument calibration and maintenance.  相似文献   
10.
It is a common practice in the midwestern United States to raise swine in buildings with under-floor slurry storage systems designed to store manure for up to one year. These so-called "deep-pit" systems are a concentrated source for the emissions of ammonia (NH3), hydrogen sulfide (H2S), and odors. As part of a larger six-state research effort (U.S. Department of Agriculture-Initiative for Future Agriculture and Food Systems Project, "Aerial Pollutant Emissions from Confined Animal Buildings"), realtime NH3 and H2S with incremental odor emission data were collected for two annual slurry removal events. For this study, two 1000-head deep-pit swine finishing facilities in central Iowa were monitored with one-year storage of slurry maintained in a 2.4 m-deep concrete pit (or holding tank) below the animal-occupied zone. Results show that the H2S emission, measured during four independent slurry removal events over two years, increased by an average of 61.9 times relative to the before-removal H2S emission levels. This increase persisted during the agitation process of the slurry that on average occurred over an 8-hr time period. At the conclusion of slurry agitation, the H2S emission decreased by an average of 10.4 times the before-removal emission level. NH3 emission during agitation increased by an average of 4.6 times the before-removal emission level and increased by an average of 1.5 times the before-removal emission level after slurry removal was completed. Odor emission increased by a factor of 3.4 times the before-removal odor emission level and decreased after the slurry-removal event by a factor of 5.6 times the before-removal emission level. The results indicate that maintaining an adequate barn ventilation rate regardless of animal comfort demand is essential to keeping gas levels inside the barn below hazardous levels.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号