首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   66篇
  免费   1篇
  国内免费   5篇
安全科学   1篇
废物处理   6篇
环保管理   8篇
综合类   10篇
基础理论   15篇
污染及防治   22篇
评价与监测   8篇
社会与环境   2篇
  2022年   2篇
  2021年   2篇
  2019年   2篇
  2018年   1篇
  2017年   3篇
  2016年   1篇
  2015年   4篇
  2014年   4篇
  2013年   1篇
  2012年   5篇
  2011年   5篇
  2010年   1篇
  2009年   6篇
  2008年   7篇
  2007年   7篇
  2006年   2篇
  2005年   7篇
  2004年   4篇
  2003年   4篇
  2002年   1篇
  2001年   1篇
  1997年   1篇
  1991年   1篇
排序方式: 共有72条查询结果,搜索用时 672 毫秒
1.
Ambient air monitoring of PCDD/Fs and co-PCBs in Gyeonggi-do, Korea   总被引:3,自引:0,他引:3  
Kim DG  Min YK  Jeong JY  Kim GH  Kim JY  Son CS  Lee DH 《Chemosphere》2007,67(9):1722-1727
We started the monitoring for PCDD/Fs in ambient air and soil in August 2001, and co-PCBs in January 2002. Decreasing of PCDD/Fs and co-PCBs levels in ambient air were observed. The higher PCDD/Fs levels were found in winter and lower in autumn. We found that the industrial incinerators influenced the PCDD/Fs levels in ambient air. In the 2,3,7,8-substituted PCDD/Fs concentration profiles, the three major congeners occupied 67% of the total mass. In case of co-PCBs, PCB#118, #105 and #77 were observed as the main congeners. Five cluster groups discriminated by ratio of four components, O(8)CDD, 1,2,3,4,6,7,8-H(7)CDD, 1,2,3,4,6,7,8-H(7)CDF and O(8)CDF, were obtained from HCA (hierarchical cluster analysis).  相似文献   
2.
Repeated application may increase rates of pesticide dissipation in soil and reduce persistence. The potential for this to occur was investigated for the fungicide, tebuconazole (alpha-[2-(4-chlorophenyl)ethyl]-alpha-(1,1-dimethylethyl)-1H-1,2,4-triazole-1-ethanol), when used for peanut (Arachis hypogaea L.) production. Soil samples were collected from peanut plots after each of four tebuconazole applications at 2-wk intervals. Soil moisture was adjusted to field capacity as necessary and samples were incubated in the laboratory for 63 d at 30 degrees C. Untreated plot samples spiked with the compound served as controls. Results indicated accelerated dissipation in field-treated samples with the time to fifty percent dissipation (DT50) decreasing from 43 to 5 d after three tebuconazole applications. Corresponding increases in rates of accumulation and decay of degradates were also indicated. Best-fit equations (r2 = 0.84-0.98) to dissipation kinetic data combined with estimates of canopy interception rates were used to predict tebuconazole and degradates concentration in soil after each successive application. Predicted concentrations compared with values measured in surface soil samples were from twofold less to twofold greater. Use of kinetic data will likely enhance assessments of treatment efficacy and human and ecological risks from normal agronomic use of tebuconazole on peanut. However, the study indicated that varying soil conditions (in particular, soil temperature and water content) may have an equal or greater impact on field dissipation rate than development of accelerated dissipation. Results emphasize that extension of laboratory-derived kinetic data to field settings should be done with caution.  相似文献   
3.
Fast and simple systems using ultraviolet (UV) absorbance were examined for on-line monitoring of monoaromatic hydrocarbons from petroleum-contaminated soils in this research. Since soil particles hinder the UV light transmittance, the absorbance measurement of vaporized monoaromatic hydrocarbons in soil gas extracted from petroleum-contaminated soils was proposed. In the fixed system that exhibited higher sensitivity than the portable one, the absorbance intensity of benzene, toluene, ethylbenzene, and xylene increased in proportion to the concentration of the contaminants. The portable system, however, was suitable for screening purpose, while it exhibited faster response. There was no interference from water, which helps the applicability of the proposed systems to the actual fields.  相似文献   
4.
An electrochemical COD (chemical oxygen demand) sensor using an electrode-surface grinding unit was investigated. The electrolyzing (oxidizing) action of copper on an organic species was used as the basis of the COD measuring sensor. Using a simple three-electrode cell and a surface grinding unit, the organic species is activated by the catalytic action of copper and oxidized at a working electrode, poised at a positive potential. When synthetic wastewater was fed into the system, the measured Coulombic yields were found to be dependent on the COD of the synthetic wastewater. A linear correlation between the Coulombic yields and the COD of the synthetic wastewater was established (10-1000 mg L(-1)) when the electrode-surface grinding procedure was activated briefly at 8 h intervals. When various kinds of wastewater samples obtained from various sewage treatment plants were measured, linear correlations (r(2)> or = 0.92) between the measured EOD (electrochemical oxygen demand) value and COD of the samples were observed. At a practical wastewater treatment plant, the measurement system was successfully operated with high accuracy and good stability over 3 months. These experimental results show that the application of the measurement system would be a rapid and practical method for the determination of COD in water industries.  相似文献   
5.
The characteristics of ammonia removal by two types of biofilter (a standard biofilter with vertical gas flow and a modified biofilter with horizontal gas flow) were investigated. A mixture of organic materials such as compost, bark, and peat was used as the biofilter media based on the small-scale column test for media selection. Complete removal capacity, defined as the maximum inlet load of ammonia that was completely removed, was obtained. The modified biofilter showed complete removal up to 1.0 g N/kg dry material/day. However, the removal capacity of the standard biofilter started to deviate from complete removal around 0.4 g N/kg dry material/day, indicating that the modified biofilter system has higher removal efficiency than the standard upflow one. In kinetic analysis of the biological removal of ammonia in each biofilter system, the maximum removal rate, Vm, was 0.93 g N/kg dry material/day and the saturation constant, Ks, was 32.55 ppm in the standard biofilter. On the other hand, the values of Vm and Ks were 1.66 g N/kg dry material/day and 74.25 ppm, respectively, in the modified biofilter system.  相似文献   
6.
7.
Jeong GH  Kim HJ  Joo YJ  Kim YB  So HY 《Chemosphere》2001,44(6):1403-1411
The objective of this study is to investigate the distribution characteristics of polychlorinated biphenyl (PCB) congeners in sediments of the lower Nakdong River of Korea. The sediments were collected using a grab sampler in May 1999. PCBs were extracted in the Soxhlet extractor and cleaned by using adsorption chromatographic techniques and concentrated sulfuric acid. A HP6890 gas chromatograph equipped with an electron capture detector was used for quantification. The results of congener specific analysis showed that the total concentration is ranged over 1.1-141 ng/g dry weight. The levels of PCB congeners are significantly correlated with the total organic carbons (TOC) in the sediments. The major fractions of PCBs in these sediments are congeners containing 4, 5 or 6 chlorine atoms per biphenyl molecule.  相似文献   
8.
In this study, chlorine decay experiments were conducted for the raw water from Nakdong River that is treated by Chilseo Water Treatment Plant (CWTP) situated in Haman, Korea as well as the e uents from sand and granular activated carbon (GAC) filters of CWTP and fitted using a chlorine decay model. The model estimated the fast and slow reacting nitrogenous as well as organic/inorganic compounds that were present in the water. It was found that the chlorine demand due to fast and slow reacting (FRA and SRA) organic/inorganic substances was not reduced significantly by sand as well as GAC filters. However, the treated e uents from those filters contained FRA and SRA that are less reactive and had small reaction rate constants. For the e uents from microfiltration, ultrafiltration, and nanofiltration the chlorine demand because FRA and SRA were further reduced but the reaction rate constants were larger compared to those of sand and GAC filter e uents. This has implications in the formation of disinfection by products (DBPs). If DBPs are assumed to form due to the interactions between chlorine and SRA, then it is possible that the DBP formation potential in the e uents from membrane filtrations could be higher than that in the e uents from granular media filters.  相似文献   
9.
Low-level liquid borate wastes have been immobilized with paraffin wax using a concentrate waste drying system (CWDS) in Korean nuclear power plants. The possibility for improving chemical durability of paraffin waste form was suggested in this study. A small amount of low density polyethylene (LDPE) was added to increase the leaching resistance of the existing paraffin waste form. The influence of LDPE on the leaching behavior of waste form was investigated by performing leaching test according to ANSI/ANS-16.1 procedure during 325 days. It was observed that the leaching of nuclides immobilized within paraffin waste form made a marked reduction although little content of LDPE was added to waste form. The acceptance criteria of paraffin waste form associated with leachability index (LI) and compressive strength after the leaching test were fully satisfied with the help of LDPE.  相似文献   
10.
The size distribution and chemical components of a fine fraction (<2.5 μm) of road dust collected at urban sites in Korea (Gwangju) and Mongolia (Ulaanbaatar) where distinct urban characteristics exist were measured. A clear bimodal size distribution was observed for the resuspended fine road dust at the urban sites in Korea. The first mode peaked at 100–110 nm, and the second peak was observed at 435–570 nm. Ultrafine mode (~30 nm) was found for the fine road dust at the Mongolia site, which was significantly affected by residential coal/biomass burning. The contribution of the water-soluble ions to the fine road dust was higher at the sites in Mongolia (15.8–16.8%) than at those in Korea (1.2–4.8%). Sulfate and chloride were the most dominant ionic species for the fine road dust in Mongolia. As (arsenic) was also much higher for the Mongolian road dust than the others. The sulfate, chloride, and As mainly come from coal burning activity, suggesting that coal and biomass combustion in Mongolia during the heating season should affect the size and chemical components of the fine road dust. Cu (copper) and Zn (zinc), carbonaceous particles (organic carbon [OC] and elemental carbon [EC]) increased at sites in Korea, suggesting that the fine road dust at these sites was significantly affected by the high volume of traffic (engine emission and brake/tire wear). Our results suggest that chemical profiles for road dust specific to certain sites should be applied to more accurately apportion road dust source contributing to the ambient particulate matter.

Implications: Size and chemical characteristics of fine road dust at sites having distinct urban characteristics were examined. Residential coal and biomass burning and traffic affected physiochemical properties of the fine road dust. Different road dust profiles at different sites should be needed to determine the ambient PM2.5 sources more accurately.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号