首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   0篇
环保管理   1篇
污染及防治   2篇
评价与监测   1篇
  2017年   1篇
  2008年   1篇
  2007年   1篇
  1997年   1篇
排序方式: 共有4条查询结果,搜索用时 250 毫秒
1
1.
Occupational exposure to benzene was measured in two gasoline marketing terminals and five major refineries in Singapore. A total of 280 workers were monitored over two years. This assessment was carried out with two primary objectives: (1) To find out the extent of occupational exposure to benzene in the petroleum industry in Singapore, (2) To identify suitable biomarkers for monitoring of low levels of benzene exposure. The exposure was measured in five different categories of petroleum and petrochemical workers, i.e., truck drivers, despatch assistant, process operators, oil movements operators and laboratory technicians. The results revealed wide variations in exposure, from 0.01 to 13.6 ppm for personal time weighted average (TWA) exposure over the whole workshift. The exposure of truck drivers appeared to be the highest, with geometric mean (GM) of 1.98 ppm (ranged from 0.25 to 13.6 ppm). The average benzene exposure for process operators was relative low with a GM of 0.04 ppm. Lowest benzene exposure was found in the laboratory technicians, with a GM of 0.02 ppm. As cigarette smoking is known to affect metabolism of benzene, data analyses on the relationships with environmental exposure were conducted only on the 190 nonsmokers. The results showed that urinary trans, trans-muconic acid (ttMA), unmetabolized benzene in urine (UBZ) and benzene in blood (BBZ) were better biomarkers for low level benzene exposure as compared to urinary phenolic metabolites in urine, such as hydroquinone, phenol and catechol.  相似文献   
2.
A simple, rapid and sensitive GC–MS method for the determination of dithiocarbamate fungicide propineb [polymeric zinc propylenebis (dithiocarbamate)] and an improved HPLC procedure for the simultaneous determination of its main metabolite, propylenethiourea, and ethylenethiourea, the main metabolite of all ethylenedithiocarbamates, in airborne samples are described. The method for the analysis of propineb involves the evolution of carbon disulfide (CS2), under acidic conditions in the presence of stannous chloride, extraction of the generated CS2 into a layer of isooctane which is then analyzed for CS2 content by GC–MS in SIM mode. Under the optimum conditions, the retention time of CS2 was 1.89 min and the total time of chromatographic analysis was 5 min. Recoveries from spiking glass microfibre filters (GF/A) and silica gel filters were 86 ± 7 (n = 9) and 89 ± 4 (n = 9), respectively. The limit of detection is 0.7 ng per filter, which is equivalent to about 0.8–1.0 ng m−3 in air. In parallel, an HPLC method with ultraviolet detection is presented for the simultaneous analysis of the metabolites. Separation of the two metabolites was attained in less than 5 min. Recoveries from spiking GF/A and silica gel filters for ethylenethiourea were 100 ± 1 (n = 3) and 98 ± 2 (n = 3), respectively, while for propylenethiourea were 102 ± 1 (n = 3) and 98 ± 1 (n = 3), respectively. The detection limits are about 36–43 and 40–49 ng m−3 in air for ethylenethiourea and propylenethiourea, respectively. All the analytes spiked in the filters are proven to be stable for more than one month, at −4 °C.  相似文献   
3.
In Japan, the Renewable Portfolio Standard (RPS) and the Feed-in-Tariff (FIT) have been used for the exploitation of renewable energy sources (RES). Although these are significant to enhance the use of RES, the RES penetration is not reaching the expected percentage. The identification of their strengths/weaknesses will allow their improvement for achieving the target. This paper concerned the evaluation of RPS and FIT using a multi-criteria evaluation method. First, official data/information were used to assess their performance using the method. Second, national experts were asked about their performance to verify the outcomes. We found FIT was more effective than RPS.  相似文献   
4.
An analytical method was developed and tested for the simultaneous determination of chlorothalonil and its main metabolite 4-hydroxychlorothalonil, in airborne samples. High performance liquid chromatography equipped with Ultra-violet detector was used to separate and quantify the analytes. Glass microfibre filters for the collection of the analytes' particles were tested. Solid sorbents, such as Tenax, Florisil, XAD-2 and silica gel, were studied to find out the most suitable material for the collection of the analytes in the gas phase. The results have shown that only chlorothalonil was trapped in the vapor phase with highest results obtained when silica gel was the sorbent of choice. Linearity was demonstrated in a wide concentration range 0.01-10.00 mg L(-1). Recoveries from spiked glass microfibre filters and silica gel cartridges for chlorothalonil and 4-hydroxychlorothalonil were almost quantitative. The quantification limits were calculated to be 8.4 and 19.6 ng m(-3) in air for chlorothalonil and 4-hydroxychlorothalonil, respectively. The two analytes spiked on the GF/A filters and silica gel cartridges were proven to be stable for more than 15 days, at 4degrees C and ambient temperature. The applicability of the present method was demonstrated by the analysis of the chlorothalonil and its metabolite in greenhouse air.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号