首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   8篇
  免费   0篇
污染及防治   7篇
社会与环境   1篇
  2021年   3篇
  2014年   2篇
  2008年   1篇
  2004年   1篇
  1995年   1篇
排序方式: 共有8条查询结果,搜索用时 78 毫秒
1
1.
Environmental Science and Pollution Research - Commuters are exposed to high air pollution levels daily, especially in areas with dense traffic. This study examines the commuter’s exposure to...  相似文献   
2.
Environmental Science and Pollution Research - A yearlong study of odor-active VOCs was carried out in the northwestern district of the city of Thessaloniki, Greece, which is in close vicinity to a...  相似文献   
3.
Manoli E  Kouras A  Samara C 《Chemosphere》2004,56(9):867-878
Polycyclic aromatic hydrocarbons (PAHs) adsorbed to ambient PM(10) were determined at three sites in Thessaloniki, northern Greece, during the period June 1997-July 1998. Ambient PAH profiles exhibited significant seasonal and spatial variations. Source PAH profiles were obtained for a number of urban, industrial and geological sources including cement, fertilizer and asphalt production, quarry operations, metal electroplating, metal welding and tempering, steel manufacture, lead and bronze smelters, metal scrap incineration, oil burning, non-catalyst equipped passenger cars, diesel fueled taxies and buses, paved road dust and soil dust. Principal component analysis (PCA) and diagnostic ratios were employed to compare ambient and source PAH profiles in an attempt to recognize compositional patterns. Similarities between the ambient PAH profiles and the profiles of certain sources, such as vehicular emissions, oil burning and metal industries, were identified.  相似文献   
4.
Polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs), including hexaclorocyclohexanes (HCHs) and DDTs, as well as trace elements were determined in soil and vegetation samples collected from the surrounding area of the landfill "Tagarades", the biggest in northern Greece, following a large scale fire involving approximately 50,000 tons of municipal waste. High concentrations of total PAHs, PCBs and heavy metals were found inside the landfill (1475 microg kg(-1) dw, 399 microg kg(-1) dw and 29.8 mg kg(-1) dw, respectively), whereas concentrations in the surrounding soils were by far lower ranging between 11.2-28.1 microg kg(-1) dw for PAHs, 4.02-11.2 microg kg(-1) dw for PCBs and 575-1207 mg kg(-1) dw for heavy metals. The distribution of HCHs and DDTs were quite different since certain soils exhibited equal or higher concentrations than the landfill. In vegetation, the concentrations of PAHs, PCBs, HCHs and DDTs ranged from 14.1-34.7, 3.64-25.9, 1.41-32.1 and 0.61-4.03 microg kg(-1) dw, respectively, while those of heavy metals from 81 to 159 mg kg(-1) dw. The results of the study indicated soil and vegetation pollution levels in the surroundings of the landfill comparable to those reported for other Greek locations. The impact from the landfill fire was not evident partially due to the presence of recent and past inputs from other activities (agriculture, vehicular transport, earlier landfill fires).  相似文献   
5.
Environmental Science and Pollution Research - PM2.5 (i.e., particles with aerodynamic diameters less than 2.5 μm) and the associated water-soluble, dissolved, and labile fractions of...  相似文献   
6.
Organic carbon (OC) and elemental carbon (EC) concentrations, associated to PM10 and PM2.5 particle fractions, were concurrently determined during the warm and the cold months of the year (July–September 2011 and February–April 2012, respectively) at two urban sites in the city of Thessaloniki, northern Greece, an urban-traffic site (UT) and an urban-background site (UB). Concentrations at the UT site (11.3?±?5.0 and 8.44?±?4.08 14 μg m?3 for OC10 and OC2.5 vs. 6.56?±?2.14 and 5.29?±?1.54 μg m?3 for EC10 and EC2.5) were among the highest values reported for urban sites in European cities. Significantly lower concentrations were found at the UB site for both carbonaceous species, particularly for EC (6.62?±?4.59 and 5.72?±?4.36 μg m?3 for OC10 and OC2.5 vs. 0.93?±?0.61 and 0.69?±?0.39 μg m?3 for EC10 and EC2.5). Despite that, a negative UT-UB increment was frequently evidenced for OC2.5 and PM2.5 in the cold months possibly indicative of emissions from residential wood burning at the urban-background site. At both sites, cconcentrations of OC fractions were significantly higher in the cold months; on the contrary, EC fractions at the UT site were prominent in the warm season suggesting some influence from maritime emissions in the nearby harbor area. Secondary organic carbon, being estimated using the EC tracer method and seasonally minimum OC/EC ratios, was found to be an appreciable component of particle mass particularly in the cold season. The calculated secondary contributions to OC ranged between 35 and 59 % in the PM10 fraction, with relatively higher values in the PM2.5 fraction (39–61 %). The source origin of carbonaceous species was investigated by means of air parcel back trajectories, satellite fire maps, and concentration roses. A local origin was mainly concluded for OC and EC with limited possibility for long range transport of biomass (agricultural waste) burning aerosol.  相似文献   
7.
Concentrations and chemical composition of the coarse particle fraction (PMc) were investigated at two urban sites in the city of Thessaloniki, Greece, through concurrent sampling of PM10 and PM2.5 during the warm and the cold months of the year. PMc levels at the urban-traffic site (UT) were among the highest found in literature worldwide exhibiting higher values in the cold period. PMc levels at the urban-background site (UB) were significantly lower exhibiting a reverse seasonal trend. Concentration levels of minerals and most trace metals were also higher at the UT site suggesting a stronger impact from traffic-related sources (road dust resuspension, brake and tire abrasion, road wear). According to the chemical mass closure obtained, minerals (oxides of Si, Al, Ca, Mg, Fe, Ti, and K) dominated the PMc profile, regardless of the site and the period, with organic matter and secondary inorganic aerosols (mainly nitrate) also contributing considerably to the PMc mass, particularly in the warm period. The influence of wind speed to dilution and/or resuspension of coarse particles was investigated. The source of origin of coarse particles was also investigated using surface wind data and atmospheric back-trajectory modeling. Finally, the contribution of resuspension to PMc levels was estimated for air quality management perspectives.  相似文献   
8.
The simultaneous action of powdered activated carbon and several coagulant agents on the removal of the fungicide dodine from spiked distilled water, was studied. As coagulants, ferric chloride (FeCl3) and basic polyaluminium chlorosulfate ([Al(OH)xCly(SO4)z]n) were examined, using polyacrylamide, in certain cases, as coagulant aid (polyelectrolyte). The efficiency of dodine removal was investigated with respect to the added amount of powdered activated carbon (PAC), the pH value, as well as the type and dose of coagulant and polyelectrolyte. The experiments were performed applying the standard jar-test procedure. The initial concentration of dodine was 250 μg/L. At this concentration and pH range 5–8 it was found that a dose of 100 mg/L PAC was necessary to achieve more than 98% removal of dodine, whereas lower removal (91–93%) was obtained applying half the dose of PAC under the same conditions. However, when 10–100 mg/L FeCl3 were simultaneously added with PAC, the removal efficiency increased to >98%, even with the half PAC dose.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号