1
1.
Abstract

Apportionment of primary and secondary pollutants during the summer 2001 Pittsburgh Air Quality Study (PAQS) is reported. Several sites were included in PAQS, with the main site (the supersite) adjacent to the Carnegie Mellon University campus in Schenley Park. One of the additional sampling sites was located at the National Energy Technology Laboratory, located ~18 km southeast of downtown Pittsburgh. Fine particulate matter (PM2.5) mass, gas-phase volatile organic material (VOM), particulate semivolatile and nonvolatile organic material (NVOM), and ammonium sulfate were apportioned at the two sites into their primary and secondary contributions using the U.S. Environmental Protection Agency UNMIX 2.3 multivariate receptor modeling and analysis software. A portion of each of these species was identified as originating from gasoline and diesel primary mobile sources. Some of the organic material was formed from local secondary transformation processes, whereas the great majority of the secondary sulfate was associated with regional transformation contributions. The results indicated that the diurnal patterns of secondary gas-phase VOM and particulate semivolatile and NVOM were not correlated with secondary ammonium sulfate contributions but were associated with separate formation pathways. These findings are consistent with the bulk of the secondary ammonium sulfate in the Pittsburgh area being the result of contributions from distant transport and, thus, decoupled from local activity involving organic pollutants in the metropolitan area.  相似文献   
2.
The real-time ambient mass sampler (RAMS) is a continuous monitor based on particle concentrator, denuder, drier, and tapered element oscillating microbalance (TEOM) monitor technology. It is designed to measure PM2.5 mass, including the semi-volatile species NH4NO3 and semi-volatile organic material, but not to measure PM2.5 water content. The performance of the RAMS in an urban environment with high humidity was evaluated during the July 1999 NARSTO-Northeast Oxidant and Particles Study (NEOPS) intensive study at the Baxter water treatment plant in Philadelphia, PA. The results obtained with the RAMS were compared to mass measurements made with a TEOM monitor and to constructed mass obtained with a Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS) sampler designed to determine the chemical composition of fine particles, including the semi-volatile species. An average of 28% of the fine particulate material present during the study was semi-volatile organic material lost from a filter during particle collection, and 1% was NH4NO3 that was also lost from the particles during sampling. The remaining mass was dominantly nonvolatile (NH4)2SO4 (31%) and organic material (37%), with minor amounts of soot, crustal material, and nonvolatile NH4NO3. Comparison of the RAMS and PC-BOSS results indicated that the RAMS correctly monitored for fine particulate mass, including the semivolatile material. In contrast, the heated filter of the TEOM monitor did not measure the semi-volatile material. The comparison of the RAMS and PC-BOSS data had a precision of +/-4.1 microg/m3 (+/-9.6%). The precision of the RAMS data was limited by the uncertainty in the blank correction for the reversible adsorption of water by the charcoal-impregnated cellulose sorbent filter of the RAMS monitor. The precision of the measurement of fine particulate components by the PC-BOSS was +/-6-8%.  相似文献   
3.
Abstract

The real-time ambient mass sampler (RAMS) is a continuous monitor based on particle concentrator, denuder, drier, and tapered element oscillating microbalance (TEOM) monitor technology. It is designed to measure PM2.5 mass, including the semi-volatile species NH4NO3 and semi-volatile organic material, but not to measure PM2.5 water content. The performance of the RAMS in an urban environment with high humidity was evaluated during the July 1999 NARSTO-Northeast Oxidant and Particles Study (NEOPS) intensive study at the Baxter water treatment plant in Philadelphia, PA. The results obtained with the RAMS were compared to mass measurements made with a TEOM monitor and to constructed mass obtained with a Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS) sampler designed to determine the chemical composition of fine particles, including the semi-volatile species. An average of 28% of the fine particulate material present during the study was semi-volatile organic material lost from a filter during particle collection, and 1% was NH4NO3 that was also lost from the particles during sampling. The remaining mass was dominantly nonvolatile (NH4)2SO4 (31%) and organic material (37%), with minor amounts of soot, crustal material, and nonvolatile NH4NO3. Comparison of the RAMS and PC-BOSS results indicated that the RAMS correctly monitored for fine particulate mass, including the semi-volatile material. In contrast, the heated filter of the TEOM monitor did not measure the semi-volatile material. The comparison of the RAMS and PC-BOSS data had a precision of ±4.1 μg/m3 (±9.6%). The precision of the RAMS data was limited by the uncertainty in the blank correction for the reversible adsorption of water by the charcoal-impregnated cellulose sorbent filter of the RAMS monitor. The precision of the measurement of fine par-ticulate components by the PC-BOSS was ±6-8%.  相似文献   
4.
Occupational exposure to benzene was measured in two gasoline marketing terminals and five major refineries in Singapore. A total of 280 workers were monitored over two years. This assessment was carried out with two primary objectives: (1) To find out the extent of occupational exposure to benzene in the petroleum industry in Singapore, (2) To identify suitable biomarkers for monitoring of low levels of benzene exposure. The exposure was measured in five different categories of petroleum and petrochemical workers, i.e., truck drivers, despatch assistant, process operators, oil movements operators and laboratory technicians. The results revealed wide variations in exposure, from 0.01 to 13.6 ppm for personal time weighted average (TWA) exposure over the whole workshift. The exposure of truck drivers appeared to be the highest, with geometric mean (GM) of 1.98 ppm (ranged from 0.25 to 13.6 ppm). The average benzene exposure for process operators was relative low with a GM of 0.04 ppm. Lowest benzene exposure was found in the laboratory technicians, with a GM of 0.02 ppm. As cigarette smoking is known to affect metabolism of benzene, data analyses on the relationships with environmental exposure were conducted only on the 190 nonsmokers. The results showed that urinary trans, trans-muconic acid (ttMA), unmetabolized benzene in urine (UBZ) and benzene in blood (BBZ) were better biomarkers for low level benzene exposure as compared to urinary phenolic metabolites in urine, such as hydroquinone, phenol and catechol.  相似文献   
5.
Gaseous and particulate pollutant concentrations associated with five samples per day collected during a July 2001 summer intensive study at the Pittsburgh Carnegie Mellon University (CMU) Supersite were used to apportion fine particulate matter (PM2.5) into primary and secondary contributions using PMF2. Input to the PMF2 analysis included the concentrations of PM2.5 nonvolatile and semivolatile organic material, elemental carbon (EC), ammonium sulfate, trace element components, gas-phase organic material, and NO(x), NO2, and O3 concentrations. A total of 10 factors were identified. These factors are associated with emissions from various sources and facilities including crustal material, gasoline combustion, diesel combustion, and three nearby sources high in trace metals. In addition, four secondary sources were identified, three of which were associated with secondary products of local emissions and were dominated by organic material and one of which was dominated by secondary ammonium sulfate transported to the CMU site from the west and southwest. The three largest contributors to PM2.5 were secondary transported material (dominated by ammonium sulfate) from the west and southwest (49%), secondary material formed during midday photochemical processes (24%), and gasoline combustion emissions (11%). The other seven sources accounted for the remaining 16% of the PM2.5. Results obtained at the CMU site were comparable to results previously reported at the National Energy Technology Laboratory (NETL), located approximately 18 km south of downtown Pittsburgh. The major contributor at both sites was material transported from the west and southwest. Some difference in nearby sources could be attributed to meteorology as evaluated by HYSPLIT model back-trajectory calculations. These findings are consistent with the majority of the secondary ammonium sulfate in the Pittsburgh area being the result of contributions from distant transport, and thus decoupled from local activity involving organic pollutants in the metropolitan area. In contrast, the major local secondary sources were dominated by organic material.  相似文献   
6.
Apportionment of primary and secondary pollutants during the summer 2001 Pittsburgh Air Quality Study (PAQS) is reported. Several sites were included in PAQS, with the main site (the supersite) adjacent to the Carnegie Mellon University campus in Schenley Park. One of the additional sampling sites was located at the National Energy Technology Laboratory, located approximately 18 km southeast of downtown Pittsburgh. Fine particulate matter (PM2.5) mass, gas-phase volatile organic material (VOM), particulate semivolatile and nonvolatile organic material (NVOM), and ammonium sulfate were apportioned at the two sites into their primary and secondary contributions using the U.S. Environmental Protection Agency UNMIX 2.3 multivariate receptor modeling and analysis software. A portion of each of these species was identified as originating from gasoline and diesel primary mobile sources. Some of the organic material was formed from local secondary transformation processes, whereas the great majority of the secondary sulfate was associated with regional transformation contributions. The results indicated that the diurnal patterns of secondary gas-phase VOM and particulate semivolatile and NVOM were not correlated with secondary ammonium sulfate contributions but were associated with separate formation pathways. These findings are consistent with the bulk of the secondary ammonium sulfate in the Pittsburgh area being the result of contributions from distant transport and, thus, decoupled from local activity involving organic pollutants in the metropolitan area.  相似文献   
7.
From October 1999 through September 2000, particulate matter (PM) with aerodynamic diameter > or =2.5 microm (PM2.5) mass and composition were measured at the National Energy Technology Laboratory Pittsburgh site, with a particle concentrator Brigham Young University-organic sampling system and a tapered element oscillating microbalance (TEOM) monitor. PM2.5 measurements had also been obtained with TEOM monitors located in the Pittsburgh, PA, area, and at sites in Ohio, including Steubenville, Columbus, and Athens. The PM data from all these sites were analyzed on high PM days; PM2.5 TEOM particulate mass at all sites was generally associated with transitions from locally high barometric pressure to lower pressure. Elevated concentrations occurred with transport of PM from outside the local region in advance of frontal passages as the local pressure decreased. During high-pressure periods, concentrations at the study sites were generally low throughout the study region. Further details related to this transport were obtained from surface weather maps and estimated back-trajectories using the hybrid single-particle Lagrangian integrated trajectory model associated with these time periods. These analyses indicated that transport of pollutants to the Pittsburgh site was generally from the west to the southwest. These results suggest that the Ohio River Valley and possible regions beyond act as a significant source of PM and its precursors in the Pittsburgh area and at the other regional sites included in this study.  相似文献   
8.
Eight typical drinking water supplies in China were selected in this study. Both source and tap water were used to investigate the occurrence of chlorinated disinfection byproducts (DBPs), and seasonal variation in the concentrations of trihalomethanes (THMs) of seven water sources was compared. The results showed that the pollution level for source water in China, as shown by DBP formation potential, was low. The most encountered DBPs were chloroform, dichloroacetic acid, trichloroacetic acid, and chlorodibromoacetic acid. The concentration of every THMs and haloacetic acid (HAA) compound was under the limit of standards for drinking water quality. The highest total THMs concentrations were detected in spring.  相似文献   
9.
Aerosol concentrations of carbonaceous material, sulfate, and nitrate for samples obtained using a newly designed PC-BOSS are reported. The results indicated that PM2.5 composition in Atlanta was dominated by sulfate and organic material, with low concentrations of particulate nitrate. Observed average particulate component concentrations for the 26-day study period were: sulfate, 12.2 μg/m3 (17.0 μg/m3 as ammonium sulfate); non-volatile organic material, 11.4 μg OM/m3 (assumes organic material, OM, is 61% C); semi-volatile organic compounds (SVOC) lost from particles during sampling, 5.3 μg OM/m3; filter retained nitrate, 0.1 μg/m3 (0.2 μg/m3 as ammonium nitrate); nitrate lost from particles, 0.3 μg/m3 (0.4 μg/m3 as ammonium nitrate); and soot (elemental carbon), 1.5 μg/m3. The PC-BOSS particle concentrator efficiency was obtained by comparison of the PC-BOSS sulfate data with sulfate data obtained from the Federal Reference Method (FRM) sampler. A modification of the PC-BOSS design to allow independent determination of this parameter is recommended.  相似文献   