1.
There is concern about the hazard of acute residential CO exposures from portable gasoline-powered generators, which can result in death or serious adverse health effects in exposed individuals. To address this hazard, the U.S. Consumer Product Safety Commission has developed low CO emission prototype generators by adapting off-the-shelf emission control technologies onto commercially available generators. A series of tests was conducted to characterize the indoor CO concentrations resulting from portable generators operating in the attached garage of a research house under seven different test house/garage configurations. The tested generators include both unmodified and modified low CO emission prototypes. It was found that CO concentrations varied widely, with peak house CO concentrations ranging from under 10 ppm to over 10,000 ppm. The highest concentrations in the house resulted from operation of the unmodified generator in the garage with the garage bay door closed and the house access door open. The lowest concentrations resulted from operation of a modified low CO emission prototype in the garage with the garage bay door open and the house access door closed. These tests documented reductions of up to 98% in CO concentrations due to emissions from two low CO emission portable generators compared to a stock generator.

Implications: Improper portable generator use has caused 800 U.S. deaths in the past 14 years. Generators operated in attached garages can cause CO to quickly reach deadly levels. Two low-emission prototypes generators were tested and had CO emissions reduced by up to 98%. Low-emission generators can reduce the risk of consumer poisonings and deaths.  相似文献   

2.
Multiple-species reserves aim at supporting viable populations of selected species. Population viability analysis (PVA) is a group of methods for predicting such measures as extinction risk based on species-specific data. These methods include models that simulate the dynamics of a population or a metapopulation. A PVA model for the California gnatcatcher in Orange County was developed with landscape (GIS) data on the habitat characteristics and requirements and demographic data on population dynamics of the species. The potential applications of this model include sensitivity analysis that provides guidance for planning fieldwork, designing reserves, evaluating management options, and assessing human impact. The method can be extended to multiple species by combining habitat suitability maps for selected species with weights based on the threat faced by each species, and the contribution of habitat patches to the persistence of each species. These applications and extensions, together with the ability of the model to combine habitat and demographic data, make PVA a powerful tool for the design, conservation, and management of multiple species reserves.  相似文献   
3.
On the basis of currently available data, approximately 97% of generator-related carbon monoxide (CO) fatalities are caused by operating currently marketed, carbureted spark-ignited gasoline-powered generators (not equipped with emission controls) in enclosed spaces. To better understand and to reduce the occurrence of these fatalities, research is needed to quantify CO generation rates, develop and test CO emission control devices, and evaluate CO transport and exposure when operating a generator in an enclosed space. As a first step in these efforts, this paper presents measured CO generation rates from a generator without any emission control devices operating in an enclosed space under real weather conditions. This study expands on previously published information from the U.S. Consumer Product Safety Commission. Thirteen separate tests were conducted under different weather conditions at half and full generator load settings. It was found that the CO level in the shed reached a maximum value of 29,300 +/- 580 mg/m3, whereas the oxygen (O2) was depleted to a minimum level of 16.2 +/- 0.02% by volume. For the test conditions of real weather and generator operation, the CO generation and the O2 consumption could be expressed as time-averaged generation/consumption rates. It was also found that the CO generation and O2 consumption rates can be correlated to the O2 levels in the space and the actual load output from the generator. These correlations are shown to agree well with the measurements.  相似文献   
4.
Anthropogenic climate change is a key threat to global biodiversity. To inform strategic actions aimed at conserving biodiversity as climate changes, conservation planners need early warning of the risks faced by different species. The IUCN Red List criteria for threatened species are widely acknowledged as useful risk assessment tools for informing conservation under constraints imposed by limited data. However, doubts have been expressed about the ability of the criteria to detect risks imposed by potentially slow‐acting threats such as climate change, particularly because criteria addressing rates of population decline are assessed over time scales as short as 10 years. We used spatially explicit stochastic population models and dynamic species distribution models projected to future climates to determine how long before extinction a species would become eligible for listing as threatened based on the IUCN Red List criteria. We focused on a short‐lived frog species (Assa darlingtoni) chosen specifically to represent potential weaknesses in the criteria to allow detailed consideration of the analytical issues and to develop an approach for wider application. The criteria were more sensitive to climate change than previously anticipated; lead times between initial listing in a threatened category and predicted extinction varied from 40 to 80 years, depending on data availability. We attributed this sensitivity primarily to the ensemble properties of the criteria that assess contrasting symptoms of extinction risk. Nevertheless, we recommend the robustness of the criteria warrants further investigation across species with contrasting life histories and patterns of decline. The adequacy of these lead times for early warning depends on practicalities of environmental policy and management, bureaucratic or political inertia, and the anticipated species response times to management actions. Detección del Riesgo de Extinción a partir del Cambio Climático por medio del Criterio de la Lista Roja de la UICNKeith et al.  相似文献   
5.
A room-size, residential air-to-air heat exchanger was tested for effectiveness of heat recovery. The experiments were conducted in a small (16.6 m3), wood frame building, the Test Chamber, on the roof of a laboratory building. The Test Chamber is a controlled and instrumented structure for which we have the ability to predict within 1% the heat loss rate over a 6-h nighttime period. With the heat exchanger installed and operating in the Test Chamber, the heat recovery efficiency was determined by comparing the actual heat loss to that expected due to the mechanically induced ventilation. The heat exchanger recovered almost 50% of the heat contained in the outgoing air flow. Additional experiments quantified effects of fan power consumption and heat conduction through the case of the device. By considering these effects, we determined that the heat exchanger itself works at an efficiency less than the manufacturer's claim. Conducting the experiments in a real building has provided insights and evaluations not possible in an indoor laboratory.  相似文献   
6.
Most species face multiple anthropogenic disruptions. Few studies have quantified the cumulative influence of multiple threats on species of conservation concern, and far fewer have quantified the potential relative value of multiple conservation interventions in light of these threats. We linked spatial distribution and population viability models to explore conservation interventions under projected climate change, urbanization, and changes in fire regime on a long‐lived obligate seeding plant species sensitive to high fire frequencies, a dominant plant functional type in many fire‐prone ecosystems, including the biodiversity hotspots of Mediterranean‐type ecosystems. First, we investigated the relative risk of population decline for plant populations in landscapes with and without land protection under an existing habitat conservation plan. Second, we modeled the effectiveness of relocating both seedlings and seeds from a large patch with predicted declines in habitat area to 2 unoccupied recipient patches with increasing habitat area under 2 projected climate change scenarios. Finally, we modeled 8 fire return intervals (FRIs) approximating the outcomes of different management strategies that effectively control fire frequency. Invariably, long‐lived obligate seeding populations remained viable only when FRIs were maintained at or above a minimum level. Land conservation and seedling relocation efforts lessened the impact of climate change and land‐use change on obligate seeding populations to differing degrees depending on the climate change scenario, but neither of these efforts was as generally effective as frequent translocation of seeds. While none of the modeled strategies fully compensated for the effects of land‐use and climate change, an integrative approach managing multiple threats may diminish population declines for species in complex landscapes. Conservation plans designed to mitigate the impacts of a single threat are likely to fail if additional threats are ignored. Manejo de Incendios, Reubicación Administrada y Opciones de Conservación de Suelo para Plantas de Vida Larga con Sembrado Obligado bajo los Cambios Globales en el Clima, la Urbanización y el Régimen de Incendios  相似文献   
7.
While emission rates of volatile organic compounds (VOCs) have been obtained for building materials, furnishings and processes in chambers, field measurements are more difficult. Procedures to estimate emission rates using transient analysis of VOC concentrations are described and applied in a two-story classroom/office building. The analysis employs semi-real-time VOC concentrations determined with a portable GC/FID and simultaneous air change rate measurements using tracer gas decay. The results of the analysis yield consistent values of emission rates for building materials ranging from 0.20 to 0.40 mg m−2 h−1 when normalized by floor area. Occupancy-related emissions were more difficult to estimate and covered a wider range from roughly 0.1 to 1.5 mg m−2 h−1. The test data were also analyzed in an attempt to determine sink parameters, but these efforts were not particularly successful. Furthermore, in these tests, the inclusion of sink effects did not significantly impact the estimated emission rates. While this paper offers a transient analysis approach that may lead to improved field estimates of VOC emission rates, it is not presented as a definitive methodology. Nevertheless, transient analysis has potential for use in other buildings, but simultaneous air change rate measurements are critical in its application in estimating VOC emission rates in the field.  相似文献   
8.
9.
Abstract: The International Union for Conservation of Nature (IUCN) Red List of Threatened Species was increasingly used during the 1980s to assess the conservation status of species for policy and planning purposes. This use stimulated the development of a new set of quantitative criteria for listing species in the categories of threat: critically endangered, endangered, and vulnerable. These criteria, which were intended to be applicable to all species except microorganisms, were part of a broader system for classifying threatened species and were fully implemented by IUCN in 2000. The system and the criteria have been widely used by conservation practitioners and scientists and now underpin one indicator being used to assess the Convention on Biological Diversity 2010 biodiversity target. We describe the process and the technical background to the IUCN Red List system. The criteria refer to fundamental biological processes underlying population decline and extinction. But given major differences between species, the threatening processes affecting them, and the paucity of knowledge relating to most species, the IUCN system had to be both broad and flexible to be applicable to the majority of described species. The system was designed to measure the symptoms of extinction risk, and uses 5 independent criteria relating to aspects of population loss and decline of range size. A species is assigned to a threat category if it meets the quantitative threshold for at least one criterion. The criteria and the accompanying rules and guidelines used by IUCN are intended to increase the consistency, transparency, and validity of its categorization system, but it necessitates some compromises that affect the applicability of the system and the species lists that result. In particular, choices were made over the assessment of uncertainty, poorly known species, depleted species, population decline, restricted ranges, and rarity; all of these affect the way red lists should be viewed and used. Processes related to priority setting and the development of national red lists need to take account of some assumptions in the formulation of the criteria.  相似文献   
10.
The performance of gaseous air cleaners for commercial and residential buildings has typically been evaluated using test protocols developed for a controlled laboratory chamber or a test duct. It is currently unknown how laboratory measurements relate to the actual performance of an air cleaner installed in a real building. However, to date, there are no air cleaner field test protocols available, thereby limiting the existing field data. The National Institute of Standards and Technology (NIST) has conducted a series of experiments to support test procedure development for evaluating the installed performance of gaseous air cleaning equipment, as well as metrics for characterizing field performance. To date, over 100 experiments have been completed, of which 23 portable air cleaner experiments and 6 in-duct air cleaner experiments are described in this paper. Tests were conducted in a finished three-bedroom/two-bathroom manufactured house equipped with several gas chromatographs to semi-continuously measure air change rates and volatile organic compound concentrations. Experimental variables included air cleaner location, isolation of zones by closing doors, and contaminant source location. For each experiment, air cleaner removal of decane was directly measured using the air cleaner inlet and outlet concentrations, as well as with mass balance analyses using measured room concentrations. With a verified mass balance model, a field performance metric was developed to compare installed whole-building performance to the performance predicted by a laboratory result. The results provide insight into the protocols and metrics that might prove useful for characterizing the field performance of air cleaners as well as the impact of air cleaner removal on zonal concentration levels in a variety of situations.  相似文献   