首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   7篇
  免费   0篇
污染及防治   6篇
评价与监测   1篇
  2013年   2篇
  2012年   1篇
  2006年   1篇
  2004年   1篇
  2000年   1篇
  1993年   1篇
排序方式: 共有7条查询结果,搜索用时 166 毫秒
1
1.
The collapse of the World Trade Center (WTC) on September 11, 2001, generated large amounts of dust and smoke that settled in the surrounding indoor and outdoor environments in southern Manhattan. Sixteen dust samples were collected from undisturbed locations inside two uncleaned buildings that were adjacent to Ground Zero. These samples were analyzed for morphology, metals, and organic compounds, and the results were compared with the previously reported outdoor WTC dust/smoke results. We also analyzed seven additional dust samples provided by residents in the local neighborhoods. The morphologic analyses showed that the indoor WTC dust/smoke samples were similar to the outdoor WTC dust/smoke samples in composition and characteristics but with more than 50% mass in the <53-microm size fraction. This was in contrast to the outdoor samples that contained >50% of mass above >53 microm. Elemental analyses also showed the similarities, but at lower concentrations. Organic compounds present in the outdoor samples were also detected in the indoor samples. Conversely, the resident-provided convenience dust samples were different from either the WTC indoor or outdoor samples in composition and pH, indicating that they were not WTC-affected locations. In summary, the indoor dust/smoke was similar in concentration to the outdoor dust/smoke but had a greater percentage of mass <53 microm in diameter.  相似文献   
2.
ABSTRACT

The use of both oxygenated fuels in carbon monoxide (CO) nonattainment areas and reformulated gasoline in ozone nonattainment areas has been mandated by the 1990 Clean Air Act Amendments. Methanol has been proposed as an alternative fuel for CO nonattainment areas. Its use will potentially increase indoor methanol inhalation exposure resulting from the evaporation of metha-nol vapor from methanol-fueled vehicles parked in residential garages. Indoor air concentrations of metha-nol, benzene, and toluene were measured in a residential home with an attached garage. The effects of vehicle emission control devices (charcoal canister hose connection); home heating, ventilation, and air conditioning (HVAC) fans; ambient air, garage, and fuel tank temperatures; and wind speed were examined.

The disconnection of the charcoal canister hose, which simulates a spent evaporative emission control device, resulted in elevated benzene, toluene, and metha-nol concentrations in the garage and attached home. Higher fuel tank temperatures resulted in higher benzene and toluene concentrations in the garage, but not methanol. The concentrations for all compounds in the garage and concentrations of benzene and toluene in the adjacent room were lower when the HVAC fan was on than when it was off, while the concentrations of all three compounds in the rest of the house were higher, although these differences were not statistically significant. Thus, the portion of the population that parks cars in garages attached to homes will experience increased methanol exposures if methanol is used as an automotive fuel.  相似文献   
3.
Investigations using chlorophyll fluorescence induction kinetics provide the parameters Rfd, L, and Ap to characterize different specifications of the photosynthetic system (PS). The application of ozone, with concentrations between 100 microg m(-3) and 2000 microg m(-3) to spruce in closed chambers yields a reduction of Rfd between 6% and 23% for the current year's needles, which indicates a reduced potential photosynthetic capacity. Further measurements on the current year's needles of spruce of the damage classes S0/S1, S2 and S3 show also a reduction of Rfd of between 7% and 14% in 2 successive years. In addition, the parameter L increases for damaged trees by between 11% and 49%, indicating a change of the chlorophyll content and of the internal energy distribution between PSI and PSII. As no effect of L can be observed with ozone fumigation, it is concluded that the change of some specifications of the PS can be simulated well by ozone fumigation (e.g. Rfd) while other specifications cannot (e.g. L).  相似文献   
4.
This paper presents the analysis of ambient air concentrations of 10 carbonyl compounds (aldehydes and ketones) measured in the yards of 87 residences in the city of Elizabeth, NJ, throughout 1999-2001. Most of these residences were measured twice in different seasons; the sampling duration was 48 hr each time. The authors observed higher concentrations for most of the measured carbonyl compounds on warmer days, reflecting larger contributions of photochemical reactions on warmer days. The estimated contributions of photochemical production varied substantially across the measured carbonyl compounds and could be as high as 60%. Photochemical activity, however, resulted in a net loss for formaldehyde. The authors used stepwise multiple linear regression models to evaluate the impact of traffic sources and meteorological conditions on carbonyl concentrations using the data collected on colder days (with lower photochemical activities). They found that the concentrations of formaldehyde, acetaldehyde, acrolein, propionaldehyde, crotonaldehyde, benzaldehyde, glyoxal, and methylglyoxal significantly decreased with increasing distance between a measured residence and one or more major roadways. They also found significant negative associations between concentrations for most of the measured carbonyl compounds and each of the following meteorological parameters: mixing height, wind speed, and precipitation.  相似文献   
5.
A new, passive particle deposition air sampler, called the Einstein-Lioy Deposition Sampler (ELDS), has been developed to fill a gap in passive sampling for near-field particle emissions. The sampler can be configured in several ways: with a protective hood for outdoor sampling, without a protective hood, and as a dust plate. In addition, there is an XRF-ready option that allows for direct sampling onto a filter-mounted XRF cartridge which can be used in conjunction with all configurations. A wind tunnel was designed and constructed to test the performance of different sampler configurations using a test dust with a known particle size distribution. The sampler configurations were also tested versus each other to evaluate whether or not the protective hood would affect the collected particle size distribution. A field study was conducted to test the sampler under actual environmental conditions and to evaluate its ability to collect samples for chemical analysis. Individual experiments for each configuration demonstrated precision of the sampler. The field experiment demonstrated the ability of the sampler to both collect mass and allow for the measurement of an environmental contaminant i.e. Cr(6+). The ELDS was demonstrated to be statistically not different for Hooded and Non-Hooded models, compared to each other and the test dust; thus, it can be used indoors and outdoors in a variety of configurations to suit the user's needs.  相似文献   
6.
The use of both oxygenated fuels in carbon monoxide (CO) nonattainment areas and reformulated gasoline in ozone nonattainment areas has been mandated by the 1990 Clean Air Act Amendments. Methanol has been proposed as an alternative fuel for CO nonattainment areas. Its use will potentially increase indoor methanol inhalation exposure resulting from the evaporation of methanol vapor from methanol-fueled vehicles parked in residential garages. Indoor air concentrations of methanol, benzene, and toluene were measured in a residential home with an attached garage. The effects of vehicle emission control devices (charcoal canister hose connection); home heating, ventilation, and air conditioning (HVAC) fans; ambient air, garage, and fuel tank temperatures; and wind speed were examined. The disconnection of the charcoal canister hose, which simulates a spent evaporative emission control device, resulted in elevated benzene, toluene, and methanol concentrations in the garage and attached home. Higher fuel tank temperatures resulted in higher benzene and toluene concentrations in the garage, but not methanol. The concentrations for all compounds in the garage and concentrations of benzene and toluene in the adjacent room were lower when the HVAC fan was on than when it was off, while the concentrations of all three compounds in the rest of the house were higher, although these differences were not statistically significant. Thus, the portion of the population that parks cars in garages attached to homes will experience increased methanol exposures if methanol is used as an automotive fuel.  相似文献   
7.
Abstract

This paper presents the analysis of ambient air concentrations of 10 carbonyl compounds (aldehydes and ketones) measured in the yards of 87 residences in the city of Elizabeth, NJ, throughout 1999–2001. Most of these residences were measured twice in different seasons; the sampling duration was 48 hr each time. The authors observed higher concentrations for most of the measured carbonyl compounds on warmer days, reflecting larger contributions of photochemical reactions on warmer days. The estimated contributions of photochemical production varied substantially across the measured carbonyl compounds and could be as high as 60%. Photochemical activity, however, resulted in a net loss for formaldehyde. The authors used stepwise multiple linear regression models to evaluate the impact of traffic sources and meteorological conditions on carbonyl concentrations using the data collected on colder days (with lower photochemical activities). They found that the concentrations of formal-dehyde, acetaldehyde, acrolein, propionaldehyde, crotonaldehyde, benzaldehyde, glyoxal, and methylglyoxal significantly decreased with increasing distance between a measured residence and one or more major roadways. They also found significant negative associations between concentrations for most of the measured carbonyl compounds and each of the following meteorological parameters: mixing height, wind speed, and precipitation.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号