首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   3篇
  免费   0篇
污染及防治   3篇
  2013年   1篇
  2002年   1篇
  2001年   1篇
排序方式: 共有3条查询结果,搜索用时 31 毫秒
1
1.
Laser-induced breakdown spectroscopy (LIBS) has been evaluated as a multimetal continuous emissions monitor (CEM) at the U.S. Environmental Protection Agency (EPA) rotary kiln incinerator simulator (RKIS) facility in Raleigh, NC. Two detection systems with a bifurcated optical fiber bundle were used for simultaneously monitoring the concentrations of Be, Cd, Cr, and Hg in the test. Two calibration techniques were evaluated in the laboratory for the field measurements. On-line calibration of relative metal concentration was also performed in the simulated incinerator gas stream. Toxic metal concentrations measured with LIBS have been compared with the EPA reference method (RM) results.  相似文献   
2.
The analytical figure of merit of the potential of laser-induced breakdown spectroscopy (LIBS) has been evaluated for detection of trace element in liquid. LIBS data of Mg, Cr, Mn, and Re were studied. Various optical geometries, which produce the laser spark in and at the liquid sample, were tested. The calibration curves for Mg, Cr, Mn, and Re were obtained at the optimized experimental conditions with bulk liquid and in liquid jet. It was found that measurements using a liquid jet provide better detection limits than bulk liquid measurements. The limits of detection (LOD) of Mg, Cr, Mn, and Re in the present liquid jet measurement are found to be 0.1, 0.4, 0.7, and 8 ppm, respectively. The LOD of Mg using Mg 279.55 nm was compared with the values found in other liquid work.  相似文献   
3.
Abstract

The analytical figure of merit of the potential of laser-induced breakdown spectroscopy (LIBS) has been evaluated for detection of trace element in liquid. LIBS data of Mg, Cr, Mn, and Re were studied. Various optical geometries, which produce the laser spark in and at the liquid sample, were tested. The calibration curves for Mg, Cr, Mn, and Re were obtained at the optimized experimental conditions with bulk liquid and in liquid jet. It was found that measurements using a liquid jet provide better detection limits than bulk liquid measurements. The limits of detection (LOD) of Mg, Cr, Mn, and Re in the present liquid jet measurement are found to be 0.1, 0.4, 0.7, and 8 ppm, respectively. The LOD of Mg using Mg 279.55 nm was compared with the values found in other liquid work.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号