首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   52篇
  免费   0篇
废物处理   2篇
综合类   28篇
基础理论   2篇
污染及防治   16篇
评价与监测   4篇
  2022年   1篇
  2021年   1篇
  2018年   1篇
  2017年   2篇
  2016年   1篇
  2014年   3篇
  2012年   5篇
  2011年   3篇
  2010年   2篇
  2009年   1篇
  2008年   3篇
  2007年   3篇
  2006年   1篇
  2005年   1篇
  2003年   2篇
  2002年   1篇
  2001年   2篇
  2000年   1篇
  1995年   6篇
  1994年   1篇
  1993年   1篇
  1992年   4篇
  1991年   1篇
  1990年   1篇
  1989年   3篇
  1985年   1篇
排序方式: 共有52条查询结果,搜索用时 500 毫秒
1.
The aim of this study was to analyse the relationship between the distribution of hay-fever patients in the city of Córdoba, south-western Iberian Peninsula, and the specific atmospheric biological content originating from local sources. Four different districts were established in the metropolitan area of the city, according to vegetational and urbanistic characteristics. Air samples were taken in each area using portable Hirst-type samplers (Lanzoni VPPS 1000) and the spectrum of biological content was defined. Patients attending the Allergy Unit at Córdoba Teaching Hospital in 2000 with allergic rhinitis and/or asthma, and displaying a positive reaction to aeroallergen extracts, were distributed within the areas as a function of their district of residence. Aerobiological results revealed differences in pollen content between areas, in terms of both quantity and number of pollen types recorded. These differences were largely due to proximity to rural areas, prevalence of pollen from typically urban species and the possible effect of urban architecture as a barrier to the dispersal/ concentration of particles and other pollutants. Patients were not uniformly distributed within the city. The majority lived in districts in which pollen from rural species was mixed with pollen from ornamentals. Patients living in typically urban districts displayed a higher prevalence of allergy to pollen from ornamentals. It is concluded that a high degree of exposure to the same environment may influence the development of sensitisation to the particular pollen load associated with that area.  相似文献   
2.
A prenatally detected case of a rare mosaic tetrasomy 12p/trisomy 12p is reported, presenting as the well-known accessory isochromosome 12p and a supernumerary single 12p marker in 17/24 and 6/24 clones of cultured amniotic fluid cells, respectively. The chromosomal nature of both marker chromosomes was investigated in cultured amniotic fluid cells by fluorescent in situ hybridization with various probes: the 12-centromeric probes pa12H8 and D12Z3, a whole chromosome 12 paint, and the chromosome 12p-specific paint M28. DNA analysis revealed a maternal origin of the extra 12p material. After counselling, the parents requested termination of pregnancy. Inspection and autopsy of the fetus revealed many of the dysmorphisms and internal structural abnormalities of the Pallister–Killian syndrome.  相似文献   
3.
Concanavalin A (Con A) subtyping of alpha-fetoprotein (AFP) revealed higher concentrations of AFP non-reactive with Con A in sera of 12 pregnant women with second-trimester oligohydramnios and raised total serum AFP levels than in sera of 42 pregnant women with raised total serum AFP levels and a normal amniotic fluid volume. This suggests that in oligohydramnios the origin of excess AFP in the maternal compartment is amniotic fluid. It is proposed that oligohydramnios and the associated raised maternal serum AFP levels are caused by damage of the fetal membranes prior to 16 weeks of gestation resulting in leakage of amniotic fluid to the decidual tissue and resorption in the maternal circulation.  相似文献   
4.
The distribution of polycyclic aromatic hydrocarbons was determined in surface sediments collected at 36 stations along the Spanish Northern continental shelf in March and September 2003, and February 2005. Concentrations of PAHs (Σ13 parent components) were in the range of 22-47528 μg/kg dw, the highest values corresponding to coastal urban-industrial hotspots and decreasing offshore. Sediment quality guidelines (SQGs) showed that concentrations of total PAHs were below the threshold effect level (TEC) in 27 stations (81%) and above in 7, two of which (Gijon and Bilbao) were above the probable effect concentration (PEC). The detailed study of diagnostic ratios suggested a rather uniform mixture of petrogenic and pyrolytic PAH sources along the continental shelf, with a slight decrease of the latter moving westwards and offshore. In order to assess the incidence of sediment sampling on the variability of the results, selected stations were also monitored in February and September 2004 and September 2005. The average field variance of the values obtained for each station was 31% that decreased to 23% when the values were normalized to TOC.  相似文献   
5.
The recovery and utilization of recovered paper have increased over past decades all over the world due to economic, environmental, and social issues. However, it is well known that an extended recovered paper collection is detrimental to its quality, either by the exploitation of lower quality sources such as households, or the spreading of commingled systems instead of selective collection systems. The influence of these two factors was assessed by analyzing the quality of different recovered paper grades used as raw material in a mill located in Madrid (Spain) producing newsprint and light weight coated paper from recovered paper. Part 1 of the paper deals with the impact of increased collection rates on the quality of recovered paper and Part 2 with the use of commingled collection systems. Results of Part 1 show that increased collection rates have a large impact on the quality of the recovered paper. The quality, measured as total unusable material and moisture contents, had deteriorated very rapidly in only 4 years (2005–2008) as a consequence of increased collection rates. Collection rates increased in Spain from 58.5% to 68.6% during this period, resulting in more than 50% increase of total unusable material and 25% of moisture content. The downgrading of the quality of recovered paper is one of the major threats for extending the current limits of paper recycling. Therefore, future challenge is to increase its availability but maintaining its quality.  相似文献   
6.
The follow-up of a cohort of adults from 29 European centers of the former European Community Respiratory Health Survey (ECRHS) I (1989-1992) will examine the long-term effects of exposure to ambient air pollution on the incidence, course, and prognosis of respiratory diseases, in particular asthma and decline in lung function. The purpose of this article is to describe the methodology and the European-wide quality control program for the collection of particles with 50% cut-off size of 2.5 microm aerodynamic diameter (PM2.5) in the ECRHS II and to present the PM2.5 results from the winter period 2000-2001. Because PM2.5 is not routinely monitored in Europe, we measured PM2.5 mass concentrations in 21 participating centers to estimate background exposure in these cities. A standardized protocol was developed using identical equipment in each center (U.S. Environmental Protection Agency Well Impactor Ninety-Six [WINS] and PQ167 from BGI, Inc.). Filters were weighed in a single central laboratory. Sampling was conducted for 7 days per month for a year. Winter mean PM2.5 mass concentrations (November 2000-February 2001) varied substantially, with Iceland reporting the lowest value (5 microg/m3) and northern Italy the highest (69 microg/m3). A standardized procedure appropriate for PM2.5 exposure assessment in a multicenter study was developed. We expect ECRHS II to have sufficient variation in exposure to assess long-term effects of air pollution in this cohort. Any bias caused by variation in the characteristics of the chosen monitoring location (e.g., proximity to traffic sources) will be addressed in later analyses. Given the homogenous spatial distribution of PM2.5, however, concentrations measured near traffic are not expected to differ substantially from those measured at urban background sites.  相似文献   
7.
8.
Six cases of macrocystic and one case of microcystic congenital adenomatoid lung malformation were diagnosed by ultrasound between 20 and 31 weeks of gestation. Combined polyhydramnios and fetal hydrops was present in three cases, polyhydramnios alone in one case, and isolated fetal hydrops also in one case. In the remaining two cases, both polyhydramnios and fetal hydrops were absent. Fetal outcome was poor, i.e., two terminations of pregnancy, three early neonatal deaths, and two survivors.  相似文献   
9.
Harmful algae can cause damage to co-existing organisms, tourism and farmers. Accurate predictions of algal future composition and abundance as well as when and where algal blooms may occur could help early warning and mitigating. The Generic Ecological Model is an instrument that can be applied to any water system (fresh, transitional or coastal) to calculate the primary production, chlorophyll-a concentration and phytoplankton species composition. It consists of physical, chemical and ecological model components which are coupled together to build one generic and flexible modelling tool. In this paper the model has been analyzed to assess sensitivity of the simulated chlorophyll-a concentration to a subset of ecologically significant input factors. Only a small number of approaches could be considered as suitable for several reasons including the model complexity, engagement of numerous interacting parameters and relatively long time of a single simulation. Thus, sensitivity analysis has been carried out with the use of the Morris method and later enriched by the computation of the correlation ratios of the selected parameters on the model response at more than a few locations in the modelled area. The obtained results are in agreement with expert knowledge of the ecological processes in the North Sea and correspond well with local characteristics.  相似文献   
10.
A new type of directional passive air sampler (DPAS) is described for collecting particulate matter (PM) in ambient air. The prototype sampler has a non-rotating circular sampling tray that is divided into covered angular channels, whose ends are open to winds from sectors covering the surrounding 360°. Wind-blown PM from different directions enters relevant wind-facing channels, and is retained there in collecting pools containing various sampling media. Information on source direction and type can be obtained by examining the distribution of PM between channels. Wind tunnel tests show that external wind velocities are at least halved over an extended area of the collecting pools, encouraging PM to settle from the air stream. Internal and external wind velocities are well-correlated over an external velocity range of 2.0-10.0 m s?1, which suggests it may be possible to relate collected amounts of PM simply to ambient concentrations and wind velocities. Measurements of internal wind velocities in different channels show that velocities decrease from the upwind channel round to the downwind channel, so that the sampler effectively resolves wind directions. Computational fluid dynamics (CFD) analyses were performed on a computer-generated model of the sampler for a range of external wind velocities; the results of these analyses were consistent with those from the wind tunnel. Further wind tunnel tests were undertaken using different artificial particulates in order to assess the collection performance of the sampler in practice. These tests confirmed that the sampler can resolve the directions of sources, by collecting particulates preferentially in source-facing channels.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号