首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   71篇
  免费   0篇
环保管理   4篇
综合类   7篇
基础理论   4篇
污染及防治   50篇
评价与监测   5篇
社会与环境   1篇
  2023年   1篇
  2022年   1篇
  2021年   1篇
  2020年   2篇
  2019年   1篇
  2018年   4篇
  2017年   1篇
  2016年   1篇
  2014年   2篇
  2013年   21篇
  2012年   1篇
  2010年   2篇
  2009年   4篇
  2008年   5篇
  2007年   4篇
  2006年   2篇
  2005年   2篇
  2004年   1篇
  2003年   1篇
  2002年   2篇
  2001年   4篇
  2000年   6篇
  1999年   1篇
  1974年   1篇
排序方式: 共有71条查询结果,搜索用时 672 毫秒
1.
Air quality in Cyprus is influenced by both local and transported pollution, including desert dust storms. We examined PM10 concentration data collected in Nicosia (urban representative) from April 1, 1993, through December 11, 2008, and in Ayia Marina (rural background representative) from January 1, 1999, through December 31, 2008. Measurements were conducted using a Tapered Element Oscillating Micro-balance (TEOM). PM10 concentrations, meteorological records, and satellite data were used to identify dust storm days. We investigated long-term trends using a Generalized Additive Model (GAM) after controlling for day of week, month, temperature, wind speed, and relative humidity. In Nicosia, annual PM10 concentrations ranged from 50.4 to 63.8 μg/m3 and exceeded the EU annual standard limit enacted in 2005 of 40 μg/m3 every year. A large, statistically significant impact of urban sources (defined as the difference between urban and background levels) was seen in Nicosia over the period 2000–2008, and was highest during traffic hours, weekdays, cold months, and low wind conditions. Our estimate of the mean (standard error) contribution of urban sources to the daily ambient PM10 was 24.0 (0.4) μg/m3. The study of yearly trends showed that PM10 levels in Nicosia decreased from 59.4 μg/m3 in 1993 to 49.0 μg/m3 in 2008, probably in part as a result of traffic emission control policies in Cyprus. In Ayia Marina, annual concentrations ranged from 27.3 to 35.6 μg/m3, and no obvious time trends were observed. The levels measured at the Cyprus background site are comparable to background concentrations reported in other Eastern Mediterranean countries. Average daily PM10 concentrations during desert dust storms were around 100 μg/m3 since 2000 and much higher in earlier years. Despite the large impact of dust storms and their increasing frequency over time, dust storms were responsible for a small fraction of the exceedances of the daily PM10 limit.
ImplicationsThis paper examines PM10 concentrations in Nicosia, Cyprus, from 1993 to 2008. The decrease in PM10 levels in Nicosia suggests that the implementation of traffic emission control policies in Cyprus has been effective. However, particle levels still exceeded the European Union annual standard, and dust storms were responsible for a small fraction of the daily PM10 limit exceedances. Other natural particles that are not assessed in this study, such as resuspended soil and sea salt, may be responsible in part for the high particle levels.  相似文献   
2.
Recent toxicological results highlight the importance of separating exposure to indoor- and outdoor-generated particles, due to their different physicochemical and toxicological properties. In this framework, a number of studies have attempted to estimate the relative contribution of particles of indoor and outdoor origins to indoor concentrations, using either statistical analysis of indoor and outdoor concentration time-series or mass balance equations. The aim of this work is to review and compare the methodologies developed in order to determine the ambient particle infiltration factor (F INF) (i.e., the fraction of ambient particles that enter indoors and remains suspended). The different approaches are grouped into four categories according to their methodological principles: (1) steady-state assumption using the steady-state form of the mass balance equation; (2) dynamic solution of the mass balance equation using complex statistical techniques; (3) experimental studies using conditions that simplify model calculations (e.g., decreasing the number of unknowns); and (4) infiltration surrogates using a particulate matter (PM) constituent with no indoor sources to act as surrogate of indoor PM of outdoor origin. Examination of the various methodologies and results reveals that estimating infiltration parameters is still challenging. The main difficulty lies in the separate calculation of penetration efficiency (P) and deposition rate (k). The values for these two parameters that are reported in the literature vary significantly. Deposition rate presents the widest range of values, both between studies and size fractions. Penetration efficiency seems to be more accurately calculated through the application of dynamic models. Overall, estimates of the infiltration factor generated using dynamic models and infiltration surrogates show good agreement. This is a strong argument in favor of the latter methodology, which is simple and easy to apply when chemical speciation data are available.

Implications: ?Taking into account that increased health risks may be related with ambient particles, a reliable estimation of the main parameters governing ambient particle infiltration indoors may assist towards the development of appropriate regulation and control measures, targeted to specific sources/factors contributing to increased exposures. The overall study of the methodological approaches estimating particle infiltration indoors suggests that dynamic models provide a more complete and realistic picture of ambient particle infiltration indoors, whereas the use of specific PM constituents to act as surrogates of indoor particles of outdoor origin seems also a promising new methodology.  相似文献   
3.
ABSTRACT

Methods that measure PM25 mass, total particulate NO3 -, and elemental carbon (EC) were evaluated in seven U.S. cities from 1997 to 1999. Sampling was performed in Bakersfield, CA; Boston, MA; Chicago, IL; Dallas, TX; Philadelphia, PA; Phoenix, AZ; and Riverside, CA. Evaluating and validating methods that measure the components of fine mass are important to the effort of establishing a speciation-monitoring network. The Harvard Impactor (HI), which measures fine particle mass, showed excellent agreement (r2 = 0.99) with the PM25 Federal Reference Method (FRM) for 81 24-hr samples in Riverside and Bakersfield. The HI also showed good precision (4.8%) for 243 24-hr collocated samples over eight studies.

The Aethalometer was employed in six of the sampling locations to measure black carbon (BC). These values were compared to EC as measured from a quartz filter using thermal analysis. For the six cities combined, the two methods were highly correlated (r2 = 0.94; 187 24-hr samples); however, the BC values were approximately 24% less than the EC measurements consistently across all six cites. This compares well to results observed for EC/BC measurements observed in other semi-urban areas. Par-ticulate NO3 - was measured using the Harvard-EPA Annular Denuder System (HEADS). This was compared to the NO3 - measured from the HI Teflon (DuPont) filter to assess NO3 - artifacts. Significant NO3 - losses (approximately 50% of total NO3 -) were found in Riverside, Philadelphia, and Boston, while minimal artifacts were observed in the other sites. Two types of HEADS configurations were employed in five cities. One system used a Na2CO3-coated glass fiber filter, and the other type used a nylon filter to collect volatilized NO3 - from the Teflon filter. The HEADS with the Na2CO3-coated filter consistently underestimated the total particulate NO3 - by approximately 20% compared to the nylon HEADS.  相似文献   
4.
Abstract

Acidic sulfate concentrations were measured in metropolitan Philadelphia during the summers of 1992 and 1993, as part of a continuing effort to characterize particle concentrations in urban environments. Sampling was performed simultaneously at eight sites located within and around metropolitan Philadelphia. Sites were selected based on their population density and on their distance and direction from the city center. Air pollution sampling was conducted every other day during the summer of 1992 and every day during the summer of 1993. All samples were collected for 24-h periods beginning at 9 a.m. (EDT). All acidic sulfate and ammonia samples were collected using modified Harvard-EPA Annular Denuder Systems (HEADS).

In this paper, we examine the spatial variation in acidic sulfate and ammonia concentrations within the metropolitan Philadelphia area. We also identify factors that may influence their variation and develop models to predict their concentrations. Outdoor sulfate (SO4 2?) concentrations were uniform within metropolitan Philadelphia; however, aerosol strong acidity (H+) concentrations varied spatially. This variation generally was independent of wind direction, but was related to local factors, such as the NH3 concentration, population density, and distance from the center of the city. Physico-chemical models, which were developed using data collected during the summer of 1992, were excellent predictors of 24-h and mean summertime H+ concentrations measured during the summer of 1993. Models accounted for 78% of the variation in 24-h H+ levels. Results suggest that a single stationary ambient (SAM) monitor would be sufficient to estimate SO4 2? exposures for populations living in Philadelphia. For H+, however, multiple monitoring sites or models should be used to determine the outdoor H+ exposures of populations living in urban environments, although a single SAM site may provide an excellent index of H+ variation over time.  相似文献   
5.
Existing and projected water shortages and related factors have helped focus attention on the need for water reuse. With recent technological advances in wastewater treatment, it is now possible to produce reclaimed water of any quality. Thus, the use of reclaimed water will depend on the reuse opportunities and the cost of the required infrastructure. Historically, centralized wastewater treatment facilities have served the needs of organized societies since the mid 1800s. However, as there are limited options for expansion of most existing centralized facilities, the use of satellite and decentralized wastewater management systems offers significant advantages including being close both to the source of wastewater generation and to potential water reuse applications. The comparative advantages of satellite and decentralized wastewater management systems for a number of water reuse applications are presented and discussed in this paper. Selected case studies are presented to demonstrate the utility of satellite and decentralized wastewater management. Specific issues associated with the application of such systems in existing and in new developments are examined and discussed.  相似文献   
6.
7.
Food and Environmental Virology - Water and wastewater virological quality is a significant public health issue. Viral agents include emerging and re-emerging pathogens characterized by extremely...  相似文献   
8.
9.
10.
Particulate matter (PM) emitted from three light-duty vehicles was studied in terms of its physicochemical and ecotoxicological character using Microtox® bioassay tests. A diesel vehicle equipped with an oxidation catalyst emitted PM which consisted of carbon species at over 97%. PM from a diesel vehicle with a particle filter (DPF) consisted of almost equal amounts of carbon species and ions, while a gasoline vehicle emitted PM consisting of ~90% carbon and ~10% ions. Both the DPF and the gasoline vehicles produced a distinct nucleation mode at 120 km/h. The PM emitted from the DPF and the gasoline vehicles was less ecotoxic than that of conventional diesel, but not in direct proportion to the emission levels of the different vehicles. These results indicate that PM emission reductions are not equally translated into ecotoxicity reductions, implying some deficiencies on the actual environmental impact of emission control technologies and regulations.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏