首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   10篇
  免费   0篇
  国内免费   1篇
废物处理   2篇
环保管理   4篇
综合类   1篇
污染及防治   3篇
评价与监测   1篇
  2012年   2篇
  2010年   1篇
  2009年   1篇
  2008年   1篇
  2006年   2篇
  2004年   1篇
  2003年   1篇
  1999年   1篇
  1996年   1篇
排序方式: 共有11条查询结果,搜索用时 15 毫秒
1.
The first example of a ruthenium sensitizer (TUS-22) having a natural dye, bisdemethoxycurcumin, as a ligand has been synthesized. The dye-sensitized solar cell based on this novel dye showed 5.8% conversion efficiency under AM 1.5 (100 mW/cm2) irradiation.  相似文献   
2.
Abstract: Hydrologic monitoring in a small forested and mountainous headwater basin in Niigata Prefecture has been undertaken since 2000. An important characteristic of the basin is that the hydrologic regime contains pluvial elements year‐round, including rain‐on‐snow, in addition to spring snowmelt. We evaluated the effect of different snow cover conditions on the hydrologic regime by analyzing observed data in conjunction with model simulations of the snowpack. A degree‐day snow model is presented and applied to the study basin to enable estimation of the basin average snow water equivalent using air temperature at three representative elevations. Analysis of hydrological time series data and master recession curves showed that flow during the snowmelt season was generated by a combination of ground water flow having a recession constant of 0.018/day and diurnal melt water flow having a recession constant of 0.015/hour. Daily flows during the winter/snowmelt season showed greater persistence than daily flows during the warm season. The seasonal water balance indicated that the ratio of runoff to precipitation during the cold season (December to May) was about 90% every year. Seasonal snowpack plays an important role in defining the hydrologic regime, with winter precipitation and snowmelt runoff contributing about 65% of the annual runoff. The timing of the snowmelt season, indicated by the date of occurrence of the first significant snowmelt event, was correlated with the occurrence of low flow events. Model simulations showed that basin average snow water equivalent reached a peak around mid‐February to mid‐March, although further validation of the model is required at high elevation sites.  相似文献   
3.
2-Ethyl-1-hexanol is a possibly causative chemical in sick building symptoms, although 2-ethyl-1-hexanol has received little attention as a hazardous substance in studies on indoor air pollution. Airborne 2-ethyl-1-hexanol concentrations were measured from 2002 to 2004 in 99 rooms of 42 non-domestic buildings in Nagoya, Japan. The diffusive sampling method is effective for the measurement of a low level of 2-ethyl-1-hexanol in indoor air. The geometric mean (geometric standard deviation) of 2-ethyl-1-hexanol concentrations was 16.5 (5.4) microg m(-3) in indoor air and 1.9 (2.2) microg m(-3) in outdoor air. The maximum concentration of 2-ethyl-1-hexanol in indoor air and outdoor air was 2709 microg m(-3) and 12.4 microg m(-3), respectively. Fewer rooms in a small number of new buildings showed high concentrations of 2-ethyl-1-hexanol, while low concentrations were observed in many rooms of these buildings as well as the other new buildings. The room-to-room concentrations of 2-ethyl-1-hexanol in each building exhibited a wide variation. The geometric mean of the 2-ethyl-1-hexanol concentrations was significantly higher for indoor air than for outdoor air (p < 0.01). The correlation of the 2-ethyl-1-hexanol concentrations between indoor and outdoor air was not significant. Mechanical ventilation was effective in the temporary reduction of indoor 2-ethyl-1-hexanol level. These results suggest that the predominant source of 2-ethyl-1-hexanol was indoor areas.  相似文献   
4.
ABSTRACT: It is important to extract and assess low flow recession characteristics for water resources planning in the upper reaches of streams. However, it is very difficult to express synthetically the low flow recession characteristics for a stream flow. In this paper, first a new method of constructing the master recession curve based on the exponential expression is proposed and applied with the restriction that there are no regulation or diversion structures in the upper reaches above the measurement station. Daily precipitation and stream flow were used for the analysis. Second, analysis for a recession constant was conducted and the relationship between the recession constant and low flow and/or geology was qualitatively examined. In conclusion, the application of the proposed method indicated that it is objective and useful for constructing the master recession curve. It became apparent that the recession constant of a master recession curve may be defined as the total index of low flow characteristics. In addition, it was found that baseflow value increases in the order of Paleozoic, Mesozoic, Tertiary, and Quaternary.  相似文献   
5.
Ozawa H  Kawaguchi H  Okuyama Y  Arakawa H 《Ambio》2012,41(Z2):149-150
The first example of a ruthenium sensitizer (TUS-22) having a natural dye, bisdemethoxycurcumin, as a ligand has been synthesized. The dye-sensitized solar cell based on this novel dye showed 5.8% conversion efficiency under AM 1.5 (100 mW/cm(2)) irradiation.  相似文献   
6.
ABSTRACT: A stochastic estimation of low flow in the upper reaches of streams is needed for the planning, development, and management of water resources and/or water use systems. In this paper, the definition and development procedure for the stochastic flow duration curve is presented and applied to five catchments located in eastern Japan and to two catchments in western Thailand. The probability distribution of N‐year daily discharge data is extracted at various percentages of time for which specified discharges are equaled or exceeded in a water year. Such a distribution is usually represented with a straight line on log‐normal probability paper. However, some of the probability plots for the annual minimum daily discharge are best represented with a straight line on Weibull probability paper. The effectiveness of the stochastic flow duration curve defined for the evaluation of flow regime is illustrated through its application. The ten year probability for the discharge exceeded 97 percent of the time may be recognized as an index of low flow. The recession shape of the lower part of the flow duration curve is dependent on the strength of low flow persistence.  相似文献   
7.
It is necessary to remove chlorine efficiently from municipal waste plastics (MWP) that contain polyvinyl chloride (PVC) and other plastics containing chlorine. In this article we consider thermal degradation liquefaction technology. In Japan, the chlorine content of reclamation oil products must be kept below 100 ppm owing to the quality standard for pyrolysis oil. Liquefaction dechlorination technology for MWP is still an important issue to study. The twin-screw extruder that has been developed as dechlorination technology for blast furnaces and coke ovens has a shorter residence time for dechlorination than other dechlorination technologies. In this article, we used a single-screw extruder for the dechlorination process because it also has a short residence time. Experiments on the dechlorination process were carried out by using a single-screw extruder to assess its dechlorination performance. Practical use of the single-screw was demonstrated by the operation of a commercial oil reclamation plant operated by Sapporo Plastic Recycle Co., Ltd. (SPR). Moreover, an investigation of cascade recycling was carried out in 2008 in which material recycle wastes were mixed with MWP and processed by chemical recycling (liquefaction). It was demonstrated that cascade recycling is an efficient recycling combination and contributes to local feedstock recycling. However, it was shown that MR wastes affect the quality of the reclamation oil when they make up more than 40% of the feed mix. If the quantity of MR wastes is kept below 40%, the reclamation oil is able to meet the quality standard. The SPR plant can be operated safely and in a stable manner.  相似文献   
8.
The dehydrochlorination behavior of plasticizer (DOP) and inorganic filler (CaCO3) contained in PVC samples and the properties of the activated carbons produced from those carbon residues have been investigated. In the dehydrochlorination process, both additives contributed not only to a decrease in HCl yield but also to the prolonged evolution of HCl. Part of the Cl species were observed to be stabilized as CaCl2 by reaction with calcium ions when CaCO3 was added. More than 80% of chlorine removal was achieved in all samples at 533 K. The use of potassium as an activation agent led to the production of activated carbon with a specific surface area greater than 1000 m2/g at the low temperature of 1023 K and assisted also in the elimination of residual Cl species by the formation of KCl during activation. Chemical Feedstock Recycling & Other Innovative Recycling Techniques 6  相似文献   
9.
Field survey of a sustainable sanitation system in a residential house   总被引:2,自引:0,他引:2  
Sustainable sanitation is an approach for more ecological and sustainable water resources management. In this paper, we proposed one of the new integrated waste treatment systems: an "sustainable sanitation system" that includes separation of the black water from water system by a non-flushing toilet (bio-toilet), and a gray water treatment based on a biological and ecological concept. Sustainable sanitation system also converts the domestic waste to soil conditioners and fertilizers, for farmland use. As one of the case studies, Environmentally Symbiotic Housing in which people actually live using the bio-toilet for the black water treatment and the household wastewater treatment facility for the gray water was introduced. The availability of this system was investigated by analyzing the sawdust used in the bio-toilet and the quality of the effluent in the household wastewater treatment facility. As the result, the water content of the sawdust did not exceed 60% in any of the sampling points and the BOD and COD of the effluent of the household wastewater treatment facility were below 10 and 20 mg/L respectively, due to the low loading. Compared to the pollution load on the water environment created by the conventional system, it was found that the effluent of the house has a lower load than the tertiary treatment and the volume of the water consumption is 75% of the conventional system.  相似文献   
10.
The storage function model is a nonlinear rainfall-runoff model that has been developed for and applied to flood runoff analysis in Japan. This paper extends the model applicability by developing practical equations for estimating model parameters which are appropriate on a regional basis, i.e., so-called regional equations. Previously, the parameters were computed from historical data for a specific basin or from relationships that do not account for land use and topography. To develop the regionalized equations, model parameters were identified for 91 flood events from 22 watersheds in Japan by applying a mathematical optimization technique. Results from 39 of these events were statistically compared and regional relationships were determined as a function of land use, basin area and rainfall intensity. The utility of the estimated equations were tested by computing runoff hydrographs for lumped basins. The estimated parameters were also applied in a distributed watershed model formulation. Both applications showed acceptable results that validate the use of the regionalized relationships.  相似文献   