排序方式: 共有42条查询结果,搜索用时 109 毫秒
1.
Kaur Sandeep Kumar Ajay Pandit Kritika Kaur Satwinderjeet 《Environmental science and pollution research international》2021,28(6):6619-6634
Environmental Science and Pollution Research - The present study investigated the antimutagenic, antioxidant, and antiproliferative properties of extracts of Cassia fistula prepared by sequentially... 相似文献
2.
3.
4.
Irradiation with ultrasound (US) and use of an enzyme (E) as pretreatment techniques were carried out to treat a complex effluent (distillery wastewater). These two techniques have been used alone as well as in combination and the efficacy of these techniques was tested by subjecting the effluent to subsequent aerobic biological oxidation (AO). When used alone, US exposure for 30 min and 2 h yielded the best COD reduction during the aerobic oxidation step (US+AO). For the enzyme when used alone, a pH value of 4.8 (corresponding to the optimum pH of the enzyme), a dose of 50 U and a pretreatment time of 24 h yielded better COD removal efficiency as compared to untreated effluent (aerobic oxidation alone). When used in combination, ultrasound followed by enzymatic pretreatment (US+E+AO) yielded the best COD removal efficiencies during aerobic oxidation as compared to the other combinations tested for the treatment of the distillery wastewater. A 4-fold increase in the initial oxidation rate was observed over the untreated batch for the integrated technique (US+E+AO). On the basis of the variation in the values of the biokinetic parameters it can be concluded that the type of pretreatment scheme affects the subsequent rate of the aerobic oxidation significantly. 相似文献
5.
Combination of ozonation with conventional aerobic oxidation for distillery wastewater treatment 总被引:1,自引:0,他引:1
Laboratory-scale experiments were conducted in order to investigate the effect of ozone as pre-aerobic treatment and post-aerobic treatment for the treatment of the distillery wastewater. The degradation of the pollutants present in distillery spent wash was carried out by ozonation, aerobic biological degradation processes alone and by using the combinations of these two processes to investigate the synergism between the two modes of wastewater treatment and with the aim of reducing the overall treatment costs. Pollutant removal efficiency was followed by means of global parameters directly related to the concentration of organic compounds in those effluents: chemical oxygen demand (COD) and the color removal efficiency in terms of absorbance of the sample at 254 nm. Ozone was found to be effective in bringing down the COD (up to 27%) during the pretreatment step itself. In the combined process, pretreatment of the effluent led to enhanced rates of subsequent biological oxidation step, almost 2.5 times increase in the initial oxidation rate has been observed. Post-aerobic treatment with ozone led to further removal of COD along with the complete discoloration of the effluent. The integrated process (ozone-aerobic oxidation-ozone) achieved approximately 79% COD reduction along with discoloration of the effluent sample as compared to 34.9% COD reduction for non-ozonated sample, over a similar treatment period. 相似文献
6.
Rao PS Ansari MF Gavane AG Pandit VI Nema P Devotta S 《Environmental monitoring and assessment》2007,128(1-3):323-328
Petroleum refineries are largest chemical industries that are responsible for the emission of several pollutants into the
atmosphere. Benzene is among the most important air pollutants that are emitted by petroleum refineries, since they are involved
in almost every refinery process. Volatile organic compounds (VOCs) are a major group of air pollutants, which play a critical
role in atmospheric chemistry. These contribute to toxic oxidants, which are harmful to ecosystem, human health and atmosphere.
The variability of pollutants is an important factor in determining human exposure to these chemicals. The ambient air concentrations
of benzene were measured in several sites around the Digboi petroleum refinery, near the city of Gowahati in northeast India,
during winter and summer 2004. The seasonal and spatial variations of the ambient air concentrations of this benzene were
investigated and analyzed. An estimation of the contribution of the refinery to the measured atmospheric levels of benzene
was also performed. The ambient air mixing ratios of benzene in a large area outside the refinery was generally low, in ppbv
range, much lower than the ambient air quality standards. This article presents the temporal and spatial variation of air
pollution in and around petroleum refinery and showed that no health risk due to benzene is present in the areas adjacent
to the refinery. 相似文献
7.
Rai Mahendra Ingle Avinash P. Gupta Indarchand Pandit Raksha Paralikar Priti Gade Aniket Chaud Marco V. dos Santos Carolina Alves 《Environmental Chemistry Letters》2019,17(1):277-290
Environmental Chemistry Letters - Food spoilage is a major global concern due to the lack of proper packaging technology. Nanotechnology is expected to improve food packaging. Indeed, novel... 相似文献
8.
9.
Joseph Khoury Maria Pang Connie Young Anita Pandit Steve Carr Dwayne Fischer James Stahl 《Water environment research》2008,80(1):53-59
Dechlorinating agents and pH adjustment are often used to preserve wastewater samples for cyanide analysis. The effects of four approved preservation protocols on the results of the total cyanide analysis of effluents from four water reclamation plants were examined. The results differed widely, and a clear pattern emerged. Immediate analysis without pH adjustment generally gave total cyanide concentrations below the reporting limit of 5 microg/L, irrespective of the dechlorinating agents used. When the pH was adjusted to > or =12, a slight increase in the measured total cyanide concentration was observed when thiosulfate was used to dechlorinate the samples, and a significant increase (>10 microg/L) was observed when arsenite was used as the dechlorinating agent. These results provide evidence that approved preservation protocols may give rise to cyanide formation in chlorinated wastewater effluent matrices. 相似文献
10.
Pandit DN Ghosh TK 《Journal of environmental biology / Academy of Environmental Biology, India》2007,28(1):141-143
The present work reports oxygen uptake in relation to group size in the juveniles (body weight: 0.70 to 1.30 g) of a climbing perch, Anabas testudineus (Bloch). The experiments were conducted at 21.5 +/- 1.0 degrees C using a cylindrical glass respirometer having continuous water flow system. With an increase in the number of fish at an interval of 5 from 5 to 40 in each fourth subsequent experiment, the weight specific aquatic oxygen uptake of a fish decreased from 0.192 +/- 0.030 to 0.800 +/- 0.006 ml O2 x g(-1)x(h(-1). When compared with a controlled fish, there was a reduction of 27.80% in the oxygen uptake in a group of 5 but 58.39% in a group of 40. A negative and significant correlation (r = 0.8411, p < 0.01) was calculated between oxygen uptake and group size of fishes. The investigation showed that probably due to shoaling behaviour, the aquatic oxygen uptake in the juveniles of A. testudineus always remained high in controlled fish or a fish in isolation than when they were in a group. 相似文献