首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   31篇
  免费   1篇
  国内免费   1篇
安全科学   1篇
废物处理   2篇
环保管理   12篇
综合类   5篇
基础理论   8篇
污染及防治   2篇
评价与监测   1篇
社会与环境   1篇
灾害及防治   1篇
  2022年   1篇
  2019年   1篇
  2017年   1篇
  2013年   4篇
  2012年   1篇
  2011年   2篇
  2010年   1篇
  2009年   4篇
  2007年   1篇
  2006年   4篇
  2005年   3篇
  2002年   1篇
  2000年   1篇
  1998年   1篇
  1995年   2篇
  1994年   1篇
  1993年   1篇
  1991年   1篇
  1985年   1篇
  1981年   1篇
排序方式: 共有33条查询结果,搜索用时 31 毫秒
1.
Water governance has emerged as perhaps the most important topic of the international water community in the 21st century, and achieving “good” water governance is now a focus of both policy discourse and innumerable development projects. Somewhat surprisingly in light of this attention, there is widespread confusion about the meaning of the term “water governance”. This paper reviews the history of the term's use and misuse to reveal how the concept is frequently inflated to include issues that go well beyond governance. Further, it highlights how calls to improve water governance often espouse predetermined goals that should instead be the very function of water governance to define. To help overcome this confusion, the paper suggests a more refined definition of water governance and related qualities of good water governance that are consistent with broader notions of the concepts. In light of the substantial resources allocated in its name, this paper's findings show there is significant potential to strengthen efforts at improving water governance.  相似文献   
2.
3.
基于RuO2-IrO2/Ti形稳电极和Fe0牺牲电极实现电氧化-电絮凝(EO-EC)一体化处理含Tl (I)废水,并与单一的电絮凝(EC)进行比较,探讨了EO-EC处理含Tl废水的机理.结果表明,相较于单一EC,EO-EC (1:1)组合技术适应于宽pH (4-10)以及电流密度范围(5-20mA/cm2)下含Tl废水高效处理,且不易发生钝化;活性氯以及氧化还原电位在Tl (I)间接氧化Tl (III)过程中扮演重要角色,沉淀分析表明生成的Tl (OH)3(s)与絮体Fe (OH)3(am)共沉淀,纤铁矿位点可吸附残留Tl (I).EO-EC一体化技术可满足实际含Tl废水达标处理(<2µg/L)且具有经济可行性.  相似文献   
4.
城市垃圾问题及处理对策   总被引:4,自引:0,他引:4  
中国的城市垃圾问题已经成为比较严重的环境问题之一,目前的垃圾处理存在很多问题.以全过程控制思想为基础,在可持续发展和"三化"原则的指导下,运用环境管理的经济、法律、行政等方法,提出解决城市垃圾问题的城市垃圾管理对策和技术对策,提出了城市生活垃圾多元化综合处理的设想,以求建立适合中国国情的城市垃圾管理体系和垃圾产业化体系.  相似文献   
5.
The ability of many insects to learn has been documented. However, a limited number of studies examining associative learning in medically important arthropods has been published. Investigations into the associative learning capabilities of Culex quinquefasciatus Say were conducted by adapting methods commonly used in experiments involving Hymenoptera. Male and female mosquitoes were able to learn a conditioned stimulus that consisted of an odor not normally encountered in nature (synthetic strawberry or vanilla extracts) in association with an unconditioned stimulus consisting of either a sugar (males and females) or blood (females) meal. Such information could lead to a better understanding of the ability of mosquitoes to locate and select host and food resources in nature.  相似文献   
6.
Polycyclic aromatic hydrocarbons (PAHs) have earned considerable attention due to their widespread environmental distribution and toxicity. In the environment, PAHs decompose by a variety of biotic and abiotic pathways. In both polar and nonpolar environments, phenanthrene (Phe, a common, three-ring PAH) is converted by sunlight to more polar products such as 9,10-phenanthrenequinone (PheQ) and subsequent oxidation products such as the corresponding open-ring dicarboxylic acid product. Biodegradation of phenanthrene also usually leads to oxidative metabolites, and eventually ends in mineralization. Our experimental objective was to investigate the photodegradation of phenanthrene and determine the effect of reaction products such as PheQ on microbial biodegradation of two- and three-ring PAHs. Abiotic experiments were performed to examine the photolytic breakdown of Phe; Phe was converted to PheQ, which catalyzed its own formation. In biodegradation experiments PheQ (0.04-4 mg/L) caused marked inhibition of naphthalene (Nap) biodegradation by a Burkholderia species; Phe did not. Only 20% of the naphthalene was degraded in the presence of PheQ compared with 75% in the control culture with no PheQ added. No PAH-degrading cultures were able to use PheQ as sole carbon source; however, the Phe-degrading enrichment culture dominated by a Sphingomonas species was able to degrade PheQ cometabolically in the presence of Phe. These results may explain why photooxidized phenanthrene-containing mixtures can resist biodegradation.  相似文献   
7.
Results from controlled in situ experimentation conducted on the leeward reef tract of Curaçao, Netherlands Antilles, indicate that the coral Montastraea annularis exhibits a complex, yet consistent, cellular response to increasing sea surface temperature (SST) and decreasing irradiance. This was determined by simultaneously quantifying and tracking the tissue density of zooxanthellae and mucocytes using a novel technique that integrates the lectin histochemical stain wheat germ agglutinin (WGA) with high-resolution (200 nm) optical epifluorescence microscopy. Coral colonies growing at 6-m water depth (WD) and an irradiance of 100.2 ± 6.5 μmol m?2 s?1 were treated with a shading experiment for 11 days that reduced irradiance to 34.9 ± 6.6, 72.0 ± 7.0 and 90.1 ± 4.2 μmol m?2 s?1, respectively. While a significant decrease in the density of both zooxanthellae and mucocytes were observed at all shade levels, the largest reduction occurred between the natural non-shaded control (44,298 ± 3,242 zooxanthellae cm?2; 4,853 ± 346 mucocytes cm?2) and the highest shading level (13,982 ± 1,961 zooxanthallae cm?2; 2,544 ± 372.9 mucocytes cm?2). Colonies were also sampled during a seasonal increase in SST of 1.5°C, where the density of zooxanthellae was significantly lower (from 54,710 ± 1,755 to 34,322 ± 2,894 cells cm?2) and the density of mucocytes was significantly higher (from 6,100 ± 304 to 29,658 ± 3,937 cells cm?2). These observations of coral cellular response to environmental change provide evidence to support new hypotheses for coral survival and the complex role played by mucus in feeding, microbial associations and resilience to increasing SST.  相似文献   
8.
Summary Thermal preferences of well-fed and food-limited fire ant colonies (Solenopsis invicta) were studied in relation to colony growth and metabolic costs. The growth curve for well-fed colonies was strongly skewed toward warmer temperatures with maximal growth occurring near 32° C (Fig. 2A). The growth curve for food-limited colonies was skewed toward cooler temperatures with maximal colony size occurring around 25° C (Fig. 2B). Food-limited colonies apparently grew larger at cooler temperatures because metabolic costs of workers were reduced. A series of binary choice tests confirmed three predictions concerning fire ant thermal preferences (Figs. 3–4). First, well-fed colonies preferred brood temperatures very near the optimum for colony growth (31° C versus 32° C). Colonies were also able to select appropriate suboptimal growth temperatures when the optimal range was unavailable. Secondly, as predicted, a large percentage of colony workers ( 30% in well-fed colonies) consistently chose cooler temperatures than those selected for the brood. This strategy probably increases longevity of workers not directly associated with brood care. Thirdly, food-limited colonies preferred cooler temperatures than well-fed colonies. Metabolic costs of food-limited colonies were reduced by approximately 7% because of (1) slightly cooler brood temperatures (30° C versus 31° C) and because (2) an additional 20–30% of the workers selected cooler temperatures. The addition of excess food reversed food-limited thermal preferences within 12 h for the brood (Fig. 5) and several days for the workers. Contrary to expectations, thermal preferences for brood in food-limited colonies did not match the food-limited growth curve, perhaps because fire ant colonies can choose to rear brood at warm temperatures while maintaining accumulated colony biomass at cooler temperatures. Correspondence to: S.D. Porter  相似文献   
9.
10.
This study presents new data‐driven, annual estimates of the division of precipitation into the recharge, quick‐flow runoff, and evapotranspiration (ET) water budget components for 2000‐2013 for the contiguous United States (CONUS). The algorithms used to produce these maps ensure water budget consistency over this broad spatial scale, with contributions from precipitation influx attributed to each component at 800 m resolution. The quick‐flow runoff estimates for the contribution to the rapidly varying portion of the hydrograph are produced using data from 1,434 gaged watersheds, and depend on precipitation, soil saturated hydraulic conductivity, and surficial geology type. Evapotranspiration estimates are produced from a regression using water balance data from 679 gaged watersheds and depend on land cover, temperature, and precipitation. The quick‐flow and ET estimates are combined to calculate recharge as the remainder of precipitation. The ET and recharge estimates are checked against independent field data, and the results show good agreement. Comparisons of recharge estimates with groundwater extraction data show that in 15% of the country, groundwater is being extracted at rates higher than the local recharge. These maps of the internally consistent water budget components of recharge, quick‐flow runoff, and ET, being derived from and tested against data, are expected to provide reliable first‐order estimates of these quantities across the CONUS, even where field measurements are sparse.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号